Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Till Drill
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of till-drill Tenders

List of latest till-drill Tenders in Indian Tenders. Click on any till-drill Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for till-drill Tenders.

Advance Search
  • All-Tenders (6)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
1 Security Services
image image
Central Government/Public Sector
TRN :49054084 |  10 Jun, 2025
Tender Value : 28.00 Crore
 Abohar - Punjab
Tender for tender for provision of deficient married accommodation at fazilka mil stn (job no: - mwp/swc-02/2024-25); 1 lump sum price worked out by the tenderer for“building /structure works as listed in schedule ‘a’ section - i 2 sch a section- ii, internal electrification works and flame proof fittings 3 material and labour for concealed point wiring for one light point/fan point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 20mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm (1:3)including fixing ofswitch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of boq as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). 4 -do- all as per srl no. 3 above but one three pin switch socket outlet 5 amps on the same borad 5 -do- all as per srl no. 3 above but one call bell controlled by one bell switch 6 -do- all as per srl no. 3 above but wiring with 2.5 sqmm multistranded cable and earth wire with copper conductor of size 2,5 sqmm for 5 amps point (on independent board) 7 material and labour for concealed point wiring for one socket outlet 15/20 amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 25mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm(1:3), including fixing ofswitch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of boq as supply only but cost of moudlar cover plate with frame and labour for fixing the same shall deemed to be included in the unit rate). 8 supply only modular switch 6amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 9 supply only modular switch 16amps,piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 10 supply only modularsocket outlet 2 in 1, 6amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 11 supply only modularsocket outlet 5 in 1, 16amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 12 supply and fixing ceiling rose, polycarbonate, isolated body, surface bakelite 2 to 3 terminal, 240 volts, 5/6 amp, isi marked complete all as specified and as directed by engineer-in-charge. 13 supply and fixingelectric calling bell ding dong type, ac 230 volts single pole including making elctric connection complete all as specified and as directed by engr-in-charge. 14 supply only modular bell push switch, piano flush type, 6amps, single pole, one way (1 module) fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) complete all as specified and as directed by engineer-in-charge. 15 supply and hanging /fixing ceiling fan 1200 mm sweep ac supply (input voltage range ; 120 to280v), bldc type, 5 star rated, bee and isi marked super enamelled, copper winding of b class insulation, single phase, maximum 30w (± 10%), temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 no blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified and as directed by engr-in-charge.note :- (i) serial number as issued by engr-in-charge of celing fan and ge office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account 16 supply and fixing exhaust fan (heavy duty) steel body, ac single phase 230v, 50hz, 900rpm, size 300mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core pvc insulated pvc sheathed copper conductor flexible cable 24/0.2mm drawn in flexible pvc conduit and hanging on wall with 4 nos steel fastners 12mm dia 200mm long and making good the disturbed surface complete all as specified and as directed by engineer-in-charge.note :- (i) serial number as issued by engr-in-charge of fan and ge office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) cost for making suitable cutting/opening in wall for fixing of exhaust fan including making good disturbed surface and masonary work shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. 17 supply and fixed for spn 8 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 18 supply and fixed for spn 6 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 19 supply and fixed for spn 4 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 20 supply and fixed for tpn distribution board 4 way vertical type double door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper bus bar suitable rating with neutral bar and earth bar and cable tie for cable management, ip-54 protection and provision and including mccb 4 pole 160 amp, 16 ka as incomer and mcbs as outgoing, dust and vermin proof complete all as specified and as directed by engineer-in-charge. 21 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, c curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 22 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 40 amps complete all as specified and as directed by engineer-in-charge. 23 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 24 supply and fixing blanking plate of plastic suitable for any type of db complete all as specified and as directed by engineer-in-charge. 25 material and labour for submain wiring comprising single core, 2 runs of 4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 20mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 26 material and labour for submain wiring comprising single core, 2 runs of 6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 27 material and labour for submain wiring comprising single core, 2 runs of 10.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 28 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing wire of size 4 mm dia by means of gi bolts/nuts/washers and protected by 15 mm bore gi light grade pipe upto test point or upto main switch board, ht/lt equipments, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 29 supply and fixing led tube light fitting polycarbonate housing 1 x 18/20watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g) aluminium housing & integrated electronic driver(h)led driver of the same make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection minimum 2.5 kv. (l) cct : minimum 6500k(m) cri : more than 80 (n) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 30 supply and fixing led tube light fitting polycarbonate housing 1 x 10watt, appx 2 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g)led driver of the same make as of the luminaire.(h) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(j) surge protection minimum 2.5 kv. (k) cct : minimum 6500k(l) cri : more than 80 (m) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 31 supply and fixing led lamp 1x9 watt including pvc holder with complete suitable for fixation on wall/roof with body robust corrosion resistant, superior flnish and without any cracks of through holes complete all as specified and directed by engineer-in-charge 32 supply and fixing energy efficient led security light fitting of 35w pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street/roadway luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of gi tubing medium grade 32mm dia, 1.2 metre long bent to shape at 32 degree angle at half metre from bottom, including two nos clamps made out of ms flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to ms clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts (c) temp operating range : minus 10°c to plus 50°c (d) power factor : minimum 0.95(e) thd : max10%.(f) ip rating : ip66. (g) ik rating:minimum ik07 (h) built in potted led driver of the make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection 10 kv (inbuilt + extended) (l) cct : 5700 k. (m) cri: more than 80 (n) lens - high efficiency wide angle lens. (o) bis approved fixtures and driver (p) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 33 rigid non metallic pvc conduit 20mm dia (external) for sub main/telephone wiring inclusive of all fittings such as tees, bends, elbow, reducers, junction boxes bell mouth tube ends and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc complete all as specified and as directed by engineer-in-charge. 34 material and labour for mild steel boxflush mounted of size 100mm x100mmx100mm having holes for 20 mm conduit entry including 02 pin tv socket outlet flush type marked with symbol of tv and 03 mm thick plastic laminated sheeet cover and making good disturbed surfaces of walls by using cm (1:3)complete all as specified and as directed by engineer-in-charge 35 supply, installing, commissioning and testing of electric water heater (geyser) storage type abs body of capacity 25 litres, bee approved 5 star rating, 230 v , single phase, ac supply, inner tank made out of heavy duty stainless steel sheet (designed with single weld line, factory tested with hydraulic pressure as per latest is code) with glass lined coating complete with all accessories such as safety valve, thermostate, nrv, connection piece pvc connection 600mm long heavy duty suitable for hot and cold water, three core pvc insulated pvc sheathed copper conductor flexible cable, 04 nos suitable size mild steel l-hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by engr-in-charge. 36 supply and fixing for led light fitting 1x9w/1x10wbulkhead luminaires including led light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 37 supply and fixing earth continuity conductor or main earthing lead 32x6mm galvanised iron strip including nuts bolts and washer fixed to wall with saddles and fixing screws or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including making good disturbed surface complete all as specified and as directed.note :- (i) conduit/pipe as required, same shall be measured & paid separately under respective item of this sch/boq. 38 subtotal 39 lump sum price worked out by the tenderer for“internal water supply works as listed in schedule ‘a’ section - iii (part-i) 40 sch a sec - iii (part-ii), internal water supply works 41 supply and fixing two way bib cock/angle stop valve with flange, cast copper alloy chromium plated, screwed down high pressure with on/off handle screwed ends suitable for 15 mm bore pipe iron pipe or for brass ferrule/unions and fixed complete all as specified and as directed. 42 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 16 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 43 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 20 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 44 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 25 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 45 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 40 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 46 supply and fixing single lever concealed diverter incl bath spout & shower complete all as specified and as directed by engineer-in-charge. 47 supply and fixing for brass chromium plated aquaguard/ro inlet valve or diverted valve with nozzle compatible for all type of water purifier fixing to steel pipe of socket of 15mm bore complete all as specified and as directed by engineer-in-charge. 48 supply and fixing for 40mm bore cpvc long handle vavle complete all as specified and as directed by engineer-in-charge. 49 supply and fixing health faucet fancy type, cp including 1.25 meter long 8mm dia flexible tube and including wall hook and fixing material complete all as specified and as directed by engineer-in-charge. 50 subtotal 51 lump sum price worked out by the tenderer for“road, pcc tiles andhume pipe culvert works) as listed in schedule ‘a’ section -iv (part-i) 52 sch a sec - iv (part-ii), road, pcc tiles andhume pipe culvert works 53 material and labour for premix bituminous concrete 40mm consolidated thicknesswith min 5.4 % binder content (bitumen of grade vg-30)by weight of total mix using sensor paver electronic sensing device for automatic leveling and profile control withi the specified toleranceand internal heating arrangement for the screed all as specified in table 500-17 of morth specification for road and bridge works 2013, rolled and compacted to required camber and gradient with tandem vibratory roller 8 to 12 tonne power roller to a uniform smooth surface complete all as specified and as directed by engineer-in-charge. 54 material and labour for thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads @ 8% by weight including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed by engineer-in-charge 55 supply and laying/fixing 80mm thick factory made chamfered edge cement concrete paver block of m-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 56 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 57 material and labour for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. 58 subtotal 59 lump sum price worked out by the tenderer for“(area drainageworks) as listed in schedule ‘a’ section -v 60 lump sum price worked out by the tenderer for“sewage disposal works as listed in schedule ‘a’ section - vi (part-i) 61 sch a sec - vi (part-ii), sewage disposal works 62 supply and laying dwcpe (sn8) drain pipes 180 (od)/163(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch 63 supply and laying dwcpe (sn8) drain pipes 200 (od)/175(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch. 64 subtotal 65 lump sum price worked out by the tenderer for“security fencing and gate works as listed in schedule ‘a’ section - vii 66 lump sum price worked out by the tenderer for “external water supply works as listed in schedule ‘a’ section-viii (part-i) 67 sch a sec - viii (part-ii),external water supply works 68 supplying, laying, jointing and testing ductileiron pipe (isi marked) class k-7, bore 150mm, confirming to is : 8329-2k, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (push-on joint) complete all as specified and as directed by engineer-in-charge.note : (i)earth work, di specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) test certificate for pipes from manufacturer shall be produced. no payment shall be entertained without test certificate. 69 supply and fixing cast iron sluice valve 150 mm dia with flanged ends class pn 1.6(heavy duty isi marked) confirming to is:14846-2000, drilled type, complete with stainless steel spindle, ci gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by engineer-in-charge. 70 material and labour for construction of brick masonary valve pit chamber size 90 x90 x90 cm (internal dimension) using sub class b bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, pcc (1:3:6) type c-2 using 40 mm graded stone aggregate in foundation, coping on top in pcc (1:2:4) type b-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, ms sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer and embeded portion of ms work duly applying black bitumenous paint before embeded complete all as specified and as directed by engineer-in-charge. 71 subtotal 72 lump sum price worked out by the tenderer for“external electrification and lightning protection works as listed in schedule ‘a’ section - ix (part-i) 73 sch a sec - ix (part-ii), external electrification and lightning protection works 74 supply and fixing lightning arresters ht 11000 v non linear expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, confirming to is 3070 (part-i) 1985 complete all as specified and as directed by engineer-in-charge. 75 supply, installing, commissioning & testing energy efficient transformer suitable for 315 kva (level-2) step down floor mounted outdoor type 11/0.433kv, 3 phase, 50 hz ac, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on hv side and star connected on lv side in accordance with vector symbol dyn-11 (vector group 4) with neutral brought out on lv side with for earthing and having tapping on hv side for constant output so as to alter/vary secondary voltage (tapping range + 5 %to - 10% in equal step of 2.5 % ) changed by means of manually operated off load taps changing gear. the voltage regulation shall be as per is including first fill of transformer oil as per is-335 and including all fittings/accessories. the limit of temperature rise after continuous full load run as specified in is-1180 (part-i) 2014 and bee certified shall be suitably adjusted to suit the maximum ambient temperature of 55 degree centigrade as prevalent complete all as specified and as directed and shall be comprised with the following fittings and accessories :- 76 (a) oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge. (b) silica gel breather with connecting pipe, first fill of dehydrating agent. (c) explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (d) air release valve plug (e) one cable box on lv side (secondary) consisting of 04 nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joints complete all as specified (f) explosive vent (g) 01 no 100 mm dial type thermometer vapor pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc. (h) thermometer pocket on tank cover (j) 04 nos plain solid ci detachable rollers (k) two nos earthing terminals marking plate. (l) rating plate and terminal marking plate(m) extra bushing for neutral outside the cable box brought out on lv side. (n) first filling of oil conforming to is and tested upto 60 kv dielectric strength (o) lifting lugs (p) oil drain valve with plug (q) one cable box on hv side (primary) consisting of 01 cable gland suitable for reception of taking in ht cable including gland joints complete all as specified (r) hand hole of sufficient size to assess interior of tank (s) dehydrating breather with first filling of dehydrating agent (t) two earthing terminal on tank body to facilitate fixing of 32x6mm gi strip. (u) rating plate with terminal marking plate (v) inspection cover. 77 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 78 (a) copper bus bar of 800 amp capacity, 4 strip mounted on porcelain insulators. (b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 500 amp (incomming).(c) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 25 ka, 125 amp - 07 (for 07 blocks).(d)mcb tpn 32 amps -01 nos (for street lights).(e) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(f) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (g) ryb led indicating lamp set of three -01. 79 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 80 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 32 amp - 16 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 81 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 82 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 16 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 20 amp - 07 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-100amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 83 supply and fixing cable junction box of size 280mm x 200mm x100mm or any other higher size (suitable for pole mounting) complete with fixing accessories. junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. the polycarbonate junction box shall be environment frinedly, recyclable, uv resistant, halogen and silicon free, anti acid and anti corrosive. the junction box knock out on four side wall and following specifications and all as directed by engr-in-charge :-(a) the junction box shall be rated for degree ofip 65 (ingress protection) in accordance with iec 60529.(b) the gasket material shall be polyurethane or silicon and gasket shall be internally embedded.(c) junction box must meet the provision laid down in iec 60998-1, iec-60695-22, iec 60670-2 to 5 and grey color according to ral-9011/ 7035.(d) the manufacturer of junction box shall submit a copy of iec certificate and glow wire test for 960 degree.(e)junction box shall be fire retardant and self extiguishing in accordance with iec60695-2 to 11, din vde 0304 part-3, ul94 v-2 flammability standard. (f) the impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with en 50298-98 for ik08.(g) junction box shall have 4 pole tinned copper bus bar of size 25mmx3mm complete with one number 20amp mcb sp 10ka (h) manufacturer should submit routine test certificate for junction box. (j) suitable size of mild steel clamps and screws/nut bolt shall be used for fixing of junction box.. 84 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing strip 32x6mm by means of gi bolts/nuts/washers and protected by 40 mm bore gi light grade pipe upto 7.5 mtr length, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing strip upto 7.5 mtr from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 85 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 86 s&f for gi steel light grade 32 mm dia bent to shape of offset angle upto 45 degree for fixing of security light fitting gi pipe 1.5 mtrs including ms clamp and nut bolts complete all as specified and as directed by engr-in-charge. 87 subtotal 88 sch a sec - x, fire fighting eqpt works 89 supply and fixing fire hydrant landing valve type a (double head outlet) gunmetal of 65 mm dia with 63 mm dia female outlet complete and 65 mm inlet with rubber blank cap and chain as per is 5290-1983, suitable for brigade hose of 63 mm with couplings conforming to is 903 (for internal hydrant at ground floor to 3rd floor and roof) complete all as specified and as directed. 90 supply, installing, commissioning and testing of fire hose cabinet to be mounted externally near the hydrant post fabricated from 16 swg mssteel of appox size 800 mm x 600 mm x 450 mm with a canopy, door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accommodate one hydrant valve, one branch nozzle and 30 mtrs hose reel, weather proof, finished with and including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer ( sample to be approved prior to entire supply) complete all as specified and as directed. 91 supply, installing, commissioning and testingof wall mounting swinging type first aid firehose reel with drum, hanging bracket, 30 mtr long and20mm dia high pressure hose reel as per is 444 with gunmetal shut off nozzle having 5mm dia orifice. the hose reel shall be conforming to is 884-1985. drum shall be fixed on adjoining wall through anchor fasteners/cement concrete book or ms stand as per site requirement complete all as specified and as directed. 92 supply, installing, commissioning and testing of 63mm dia gun metal, short type, instantaneous pattern branch pipe to suit fire hose delivery coupling of 63 mm size complete with gm nozzle of 20 mm nominal size conforming to is 8090 complete all as specified and as directed. 93 supply, installing, commissioning and testing of gun metal body butterfly valves of size 63mm dia, is:210, pn-16, confirming to is:13095 complete all as specified and as directed. 94 supply, installing, commissioning and testing of booster pump 30 m head, 450lpm discharge, 440 v, 3 phase, 50hz confirming to is- 12469 :1988 with ci casing bronze impeller and stainless steel shaft mounted on heavy duty bearings complete all as specified and as directed. 95 supply, installing, commissioning and testing 65mm nominal bore, wall thickness 6mm, ms heavy duty (c class) flanged pipe, isi marked (is : 1239) with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer complete all as specified and as directed. 96 supply and fixing trolley mounted water stored pressure type fire extinguishers, 9 ltr capacity conforming to is:13386 with extinguishing agent :water+afff and propelling nitrogen gas, wall bracket handle fitted with high pressure flexible discharge hose with discharge throw of 2-5 mtrs.,with isi certification markcomplete all as specified and as directed. 97 supply and fixing carbon-di-oxide 3 kgs capacity fire extinguisher (light weight squeeze grip type) fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn, and cylinder bearing no., confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 98 supply and fixing dry chemical powder fire extinguisher ( abc powder ) 9 kgs capacity stored pressure type, ce mark valve with nrv & safety release provision with epdm rubber hose, the extinguisher is internally coated with epoxy polyester and externally coated with pure polyester powder and confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 99 supply and fixing mechanical foam extinguisher of 9 ltr capacity and confirming to is:15683:2006 complete all as specified and as directed. 100 supply and fixing fire buckets (dry sand)of 7 kg capacity including hanging arrangements complete all as specified and as directed. 101 supply and fixing emergency exit sign board with double side adhesive tape vinyl sticker with forex board (green and white colour) 30 cm x 10 cm complete all as specified and directed. 102 subtotal 103 lump sum price worked out by the tenderer for“lift works as listed in schedule ‘a’ section - xi (part-i) 104 sch a sec - xi (part-ii), (lift works) 105 supply, installing, commissioning and testing 13 passenger lift, having 1.0 m/s car speed, gearless motor suitable for 3- ph, 415 v, 50 hz electric power supply, conforming to is-14665, suitable to serve g + 3 upper floors with ac variable voltage & variable frequency drive (vvvf drive), complete with all standard accessories, simplex full collective operation, centre opening doors with door drive, sliding stainless steel doors, automatic rescue device (ard) system, 2d infrared sensor in full height of door & built in press and speak 3 way intercom. complete all as specified and as directed and shall conform to the following specifications: 106 type of lift : passenger lift 107 capacity of lift : 884 kg, 13 person 108 rise : up to g+3 bldg 109 stop and opening - 04 stops with all opening on the same side 110 controller type : microprocessor based 111 drive : ac vvvf drive 112 power supply : 400/415 volts (3 phase ac) 113 operation : full collective operation 114 car group : simplex type 115 machine : gearless motor located above shaft in machine room 116 traction media : steel rope 117 car finish : rear mid panel, rear corner panel, side mid panels, side corner panels, front panels all are made of stainless steel ss304 with honey comb finish 118 false ceiling finish : stainless steel with hairline finish and with provision for led lights specified here-in-after. 119 ventilation : pvc heavy duty cross flow fans 120 hand rails : stainless steel finish round handrails on rear car panels 121 flooring :20mm thick granite to be provided in the recess car cabin floor and fixing with suitable adhesive over aluminium chequered plate in one piece minimum 3mm thick. 122 car door and landing door finish : stainless steel ss-304, mirror finish outside 123 fire rated doors : fire rating - 60 minutes 124 pit depth: 1600 125 overhead : 4500 126 hoistway dimensions(w x d – mm) : 2500 mm w x 1900 mm d 127 car size (w x d x h - mm) : as per is-14665 (part 3 sec-i) : 2000, height 2200 mm 128 car & hoistway door type : central opening (co) doors 129 door opening (w x h - mm) : 900 mm w x 2000 mm h 130 door operator : vf 131 cop : cop (car operating panel) and lop (landing operating panel) in stainless steel hairline finish with display. 132 car position indicator : dot matrix type 133 hall fixtures : dot matrix type 134 hall fixture face plate : stainless steel hairline finish-ss-304 135 hall button arrangement: hall and call buttons with illumination and braille 136 car and counter weight guide as per oem recommendation 137 terminal buffers metal spring/oil buffer as per oem recommendation 138 standard features :anti-nuisance car call protection, independent service, overload device, nudging, emergency car light unit, infrared curtain door protection, door time protection, emergency alarm button, extra door time of lobby & parking door open/close button, manual rescue operation, auto fan cut off, over speed governor for car 139 also included : emergency firemen’s service, automatic rescue operation, intercom. 140 car enclosure: manufactured with stainless steel frame not less than 1.5mm with honey combfinish (ss-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with led sleek light fittings (as per manufacturer’s instructions, minimum 04 nos) operated on commercial supply and one led light fitting operated on battery with inverter as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection 141 floor announcement system in car cabin 142 signals: (a) combined luminous hall buttons with led hall position indicators at all floors (b) led car position indicator panel of stainless steel (c) car operating panel of stainless steel with luminous buttons in car (d) car direction indicator in car & landing (e) battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (the system shall be separate from ard batteries.) (f) overload warning feature in car cabin (display / announcing type both) (g) one firemans switch to be installed at ground floor near landing door. (h) all signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (j) infrared door sensor safety edge of door for entire height. 143 safety device: (a) automatic rescue device (ard) / automatic landing device operating with maintenance-free batteries having suitable capacity. the batteries must have auto charging facilities. (b) the ard actuation time shall be less than one second after failure of power supply and when ard is operative the car shall stop at the nearest floor and then doors shall open. 144 operation: simplex, full collective automatic operation 145 machine room: located above the hoist way, details as per building drawings 146 hoist way: construction details as per building drawings 147 civil work: necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. 148 one number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. the telephone instrument shall be connected in the telephone db installed in the machine room 149 looking mirror of size 1200x900mm, 5.5mm thick to be provided on rear panel wall (opposite to main door) of car cabin above hand rail 150 provision of suitable size of copper conductor xlpe insulated cable from lift panel installed at ground floor to machine room will deemed to be included the rate quoted by the contractor 151 subtotal 152 lump sum price worked out by the tenderer for“excavation, earthwork and site development works as listed in schedule ‘a’ section - xii 153 schedule a section -xiii (furniture works) 154 almirah small steel as per drawing no. fd-1032 sheet no. 1/1 155 book shelf open (large) steel as per drawing no. fd-69(m) sheet no. 1/1 156 bed hard as per drawing no. fd/e6/map/08(r) sheet no. 1/1 157 chair verandah as per drawing no. fd/e6/map/11 sheet no. 1/1 158 charpoy folding ip with hard top as per drawing no. fd-388(r) sheet no 1/1 159 peg table as per drawing no. fd/map/11 sheet no. 1/1 160 rack shoe steel as per drawing no. fd/e6/map/02(r) sheet no. 1/1 161 table bed side as per drawing no. fd/e6/map/15(r) sheet no. 1/1 162 table centre as per drawing no. fd/map/08 sheet no. 1/1 163 dressing table including stool as per drawing no. fd/map-ii/07 sheet nos 1/2 & 2/2 164 chair dining jcos/ors as per drawing no. fd/map-ii/05 sheet no. 1/1 165 chair easy per drawing no. fd-229 sheet no. 1/1 166 chair writing as per drawing no. fd-280 sheet no. 1/1 167 charpoy with hard top as per drawing no. fd/map-ii/01 sheet no. 1/1 168 mirror dressing(gents) as per drawing no. fd/e6/map/16 sheet no. 1/1 169 table dining 4 persons as per drawing no. fd/map-ii/03 sheet no. 1/1 170 table with drawer (900 mm x 600 mm x 760 mm) as per drawing no. fd-283 sheet no. 1/1 171 chair school with hand board as per drawing no. fd/e6/map/05 sheet no. 1/1 172 note:-quantities of materials given on standard drawings are for guidance only. the contractor shall work out the quantities of materials required for each item of boq and quote his rate accordingly no claim shall be entertained on account of inaccuracy in the quantities of these materials and workman ship which shall be as specified in particular specifications and as approved. the drawing nos mentioned in boq item no 184 to 264 shall form part of tender document which will not be attached with tender document. the tenderers are deemed to be in possession and conversant fully with the drawing shown in standard furniture designs including amendments published by ahq, engineer-in -chief, new delhi. for reference and guidance the tenderer may study and see these drawings in the any office ofgarrison engineer in mes before quoting their rates. no claim shall be entertained regarding misinterpretation of the drawings at a later stage. 173 subtotal 174 lump sum price worked out by the tenderer for“arboriculture works as listed in schedule ‘a’ section - xiv (part-i) 175 schedule a section -xiv (part-ii) (arboriculture works) 176 material and labour for grassing with selection no.1 grass including enough watering and maintance of the lawn till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed including supplying and spreading of neem oil cakes, manure or sludge and chemical required for preparation of the ground for plantation of grass complete all as specified and as directed. 177 supply and planting of hedge and shrubbery (anarmi, ficus and the like) as directed by engineer-in-charge minimum 3 feet above gl including creation of beds by excavating 60 cm deep and 60 cm wide trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio 8:1 (8 part of stacked volume of earth after reduction of 20 % with 1 part of stacked volume of sludge or manure ater reduction by 8%) flooding with water filling with earth if necessary, watering and finally fine dressing leveling etc including stacking and disposal of material declared unserviceable and surplus earth by spreading and leveling as directed within a lead 50 m and lift upto 1.50 m complete all as specified and as directed. 178 supply and laying/fixing 60mm thick factory made chamfered edge cement concrete paver block of m-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 179 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 180 supply and laying factory made kerb stone of size 30x15x45cm of m-25 grade cement concrete laid in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement:3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed by engineer-in-charge 181 supplying following plants in poly bags 0.25 m to 0.30m dia with height 1.20 m to 1.80 m including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 2:1(2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludgeor manure after reduction by 8%) flooding with water and removal of surplus soil, with & including antitermite treatment using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 182 neem tree. 183 canerydate palm 184 gulmohar 185 fruit bearing trees 186 plumeria 187 supplying plants flower like ticoma, rose,motia, chandni, lxora, marigold rose, vinca (any colour) as directed of height not less than 0.60m above gl including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 3:1(one part of manure & 3 part of soil) manure 200 gm per plant ,flooding with water and removal of surplus soil n.exc 1.50 km and depositing where directed with & including using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 188 supply and fixing precast rcc 1:1.5:3 type a1 lawn bench and backsupport of size 1.50 x 0.60m of maximum three person seating capacity supporting precast rcc type a1 for back and base with including assemble the precast member with suitable nutt & bolt and placing and anchoring with hold fast 350mm - 16mm dia ms bar on concrete base (size 1.20x0.60m for each support) with 100mm thick pcc 1:2:4 type b1 over 150mm thick sub base pcc 1:4:8 type d2 complete all as specified and as directed by engineer-in charge 189 subtotal 190 schedule a section -xv ( maintance) 191 material and labour for the plants/hedge/grass by weeding, hosing, saucer making once in every month for plants/hedge, once in every 15 days for carpet grass/country grass/doob grass, bermuda grass, pruning dired ranches once in every week, depositing the material at place of dead plants of same species and height turning with dods whenever required by replacing the dead patches of grass of any type with same grass as required without any extra cost to the department all as specified and as directed. (plants of various species -678 nos (approx), hedge and shruery - 520 rm (approx) and grass - 4000 sqm( approx) 192 subtotal
  • View Tender
  • Document
  • Bid Support
2 Security Services
image image
Central Government/Public Sector
TRN :49055122 |  29 May, 2025
Tender Value : 40.00 Lacs
 Palam - Delhi
Tender for comprehensive maintenance and certain misc b/r works in tech area at af stn palam under ge (af) palam, delhi cantt - 10; 1.00 taking down cement plaster on brick, stone or concrete surfaces of walls etc incl racking out joints hacking for key scrubbing down with water etc and removing the debris from site to out site mod land complete all as specified and directed by engr-in-charge . 2.00 m&l for 10mm thick rendering of ready mix mortar of approved make on brick work or concrete surfaces on internal walls, finished the surface even and smooth without using extra cement as on wall as whole or in patch etc complete all as specified and as directed. make- birla (hil) or its equilent. 3.00 m&l for 15mm thick rendering of ready mix mortar of approved make on brick work or concrete surfaces on external walls, finished the surface even and fair without using extra cement by using dr. fixit (wpc) @ 3% of wt of cement content complete all as specified and as directed. note:- water proofing compound shall be measured and paid seprately. 4.00 m&l for 5mm thick cement plater of ready mix mortar of approved make as on ceiling & plastering to be finished even & smooth without using extra cement complete all as specified and as directed. make- birla (hil) or its equilent. 5.00 supply only integral water proofing compound complete all as specified and as directed. 6.00 m&l for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkalic resistent primer complete all as specified and as directed 7.00 m&l for applying two coats of 100% premium acrylic emulsion paint having voc less than 50 gm/ltr and uv resistance as per is 15489-2004, alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.9 litre /10 sqm over new surfaces complete all as specified and as directed. 8.00 m&l for preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of alkalic resistent primer complete all as specified and as directed. 9.00 m&l for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster (1:4) (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and as directed. note:- payment for providing grooves shall be measured and paid separately. 10.00 m&l for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications complete all as specified and as directed. 11.00 demolition of cement concrete (un reinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) and removing the debris from site to out site mod land complete all as specified and as directed. 12.00 m & l for 75mm thick cement concrete (1:3:6) type c2 (using 40mm graded stone aggregate) as in plinth protection, finished even and smooth without using extra cement, including making joints 12 mm wide to the full depth of pcc at every 3 metres and at every change of direction and filling the same with & including bitumen 85/25 and sand in the proportion of (1:3 ) by weight complete all as specified and as directed. 13.00 m&l for 75mm thick pcc (1:3:6) type c2 (using 40mm graded stone aggregate) as in path and paving, finished even and smooth without using extra cement complete all as specified and as directed. 14.00 m&l for 25 mm thick pcc (1:2:4) type b1 (using 20mm graded stone aggregate) as in floor, finished even and smooth with using extra cement complete all as specified and as directed. 15.00 m&l for plain cement concrete (1:3:6) type c1 (using 20 mm graded stone aggregate) as in surface channel/drain complete all as specified and as directed. 16.00 extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and as directed. 17.00 supply and fixing in repairs, sfrc drain cover any size, 75mm thick laid over existing drain complete all as specified and as directed by engr-in-charge. notes: - (i) make of sfrc manhole/drain cover and frame : (a) m/s ps concrete.(b) m/s kk manhole.(c) or equivalent as approved by ge. (ii) contractor will provide manufacturer test certificate of sfrc cover . 18.00 dismantling wall and ceiling boards ( fibre, pulp, insulation etc.) or insulation boards / slabs / blankets, any thickness, including fillets complete all as specified and as directed. 19.00 m & l for provding false ceiling of 12mm thick fine fissure board sharped finished mineral fiber accountic false ceiling tiles with back of the duly sanded and finshed with a coat of protective paint and front duly finished false system of size (600x600) mm having noise reduction co-efficient of 0.55 light reflection of 80% thermal conductivity k=0.057 w/wwc and humidity resistance of 95% fixed to true look pvc die kl -24 suspension system (hot dipped aglvanised steel section) of exposed t section consisting of perimeter wall angle of size (24x24) mm of thickness 0.45 of mm c/c universal main runner of t shape with double rotary siticing of size (38x25) mm of lenght 1200mm made from 0.33gs steel of lenght 3.60 mtr to be spced at 600x 600mm size) c/c cro runner t shape wtih double rotary siticing of size (30x24)mm of length 1200mm made 0.25 thick gs sheet spaced @ 600mm c/c (600mm 600mm) size complete all as specified and directed by engineer -in- charge. 20.00 taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 sqm each including cutting holes in walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified and as directed. 21.00 taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size exceeding 1.50 sqm but n. exc 4.0sqm each including cutting holes in walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified and as directed. 22.00 taking down shutters of any description of size n. exc 1 sqm each complete all as specified and as directed. 23.00 taking down shutters of any description of size exc 1 sqm and n exc 2 sqm each complete all as specified and as directed. 24.00 taking down shutters of any description exc 1 sqm and n exc 2 sqm each and re-fixing in the same opening after necessary repairing viz shifting of hinges/tower bolt / handle position etc complete all as specified and as directed. note:- cost of screws/nails and minor items shall be deemed to be included in the unit quoted rates. 25.00 s&f anodised aluminium powder coated frame for door, windows, ventilators, partition wall with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed 26.00 s&f anodised aluminium powder coated door shutter, aluminium section wt 0.55 kg/m including neccesary joining cleats, glazing clips, rubber neoprene packing, aluminium handle 2 nos in each door, hinges, anodised aluminium snap beading screw etc. complete all as specified and as directed. 27.00 s&f anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised, handle 2 nos in each window, aluminium fittings such as peg stays150mm long (1 no.), hinges type b-21100mm long (2 no.), suitable handle (1no.) complete all as specified and as directed. 28.00 s&f aluminium anodised with powder coating (minimum thickness of powder coating 50 micron) grill of design and parttern as approved by ge including aluminium beading complete all as specified and as directed. 29.00 s&f 5.50mm thick tinted, sheet glass of selected quality fixed to aluminium frame work complete all as specified and as directed. 30.00 m&l for 12mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination & fixed with screws to timber/aluminium frame complete all as specified and as directed 31.00 s & f door closer hydraulically regulated designation no 3 universal type suitable for door shutter of 851 to 1000 mm in width of aluminum body (die cast) weight between 61 to 80 kg complete all as specified and as directed. 32.00 m&l double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminum alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other party made of mild steel heavy duty complete all as specified and as directed. 33.00 s & f mild steel mortic lock vertical type size 100mm 4 levers complete all as specified and as directed. 34.00 s&f aluminium tower bolt of extruded section, 150mm length of bolt and fixed with screws complete all as specified and as directed. 35.00 s&f aluminium door stopper double legged with rubber shoe 75mm long fixed to door shutters complete all as specified and as directed. 36.00 m & l 2nd class hard wood plain, solid, straight chowkhats, and frame wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed. 37.00 s&f for 30mm thick factory made flush shutter, solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and as directed. 38.00 s&f for factory made single extruded wpc (wood polymer composit) solid door/window and other frames/chowkhat of size 50x100 mm comprising of virgin pvc polymer of k value 58-60 (suspension grade) calcium carbonte and natural fibers (wood powder/rice husk/wheat husk) and non toxic aditives(maximum toxicity index of 12 for 100 gms) fabricated with full body threaded star headed ss screws having minimum frame density of 750 kg/cum screw withdrawl strength of 2200 n(face) & 1100n(edge) minimum compressive strength of 58 n/sqmm modules of ealsticity 900 n/sqmm and resistance to spread of flame of class a category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with ms hold fast/ lugs/ss dash fasteners of required dia and length complete as per direction of enger-in-charge. make- m/s rajshree plastiwood ltd or its equivalent as per list of make. 39.00 s&f for factory made single extruded wpc (wood polymer composit) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of k value 58-60 (suspension grade) calcium carbonte and natural fibers (wood powder/rice husk/wheat husk) and non toxic aditives(maximum toxicity index of 12 for 100 gms) fabricated with full body threaded star headed ss screws having minimum frame density of 650 kg/cum screw withdrawl strength of 1800 n(face) & 900n(edge) minimum compressive strength of 50 n/sqmm modules of ealsticity 850 n/sqmm and resistance to spread of flame of class a category with property of being termite/borer proof, water/moisture proof and fire retardant. wpc to be laminated with pvc foil of minimum 14 microns thick of approved design pasted with hotmelt adhesiv on both faces of shutter and fixing with stailess steel butt hinges of required size with necessary full body threaded star headed counter sunk ss screws all as direction of enger-in-charge. make:- m/s rajshree plastiwood ltd or its equivalent as per list of makes. 40.00 dismantling of floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles and rubbish off the premises complete all as specified and as directed. 41.00 m&l for vitrified ceramic tiles 8-10 mm thick, 1st quilaty (square/rectuangular) polished, double charge shade, area of each tiles exceeding 0.36 sqm but not exc. 0.42 sqm, as in floors etc. set and jointed with neat cement slurry and pointed in white or coloured cement to match with and including over15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. 42.00 description all as per srl item no. 39.00 bove but as in skirting over 10mm thick plastering with cm (1:4) complete all as specified and as directed. 43.00 m &l for ceramic coloured/ printed non-skid tiles of size 7 to 8 mm thick( square / rectangular) area of each tile exceeding 0.06 sqm but n exc 0.16 sqm laid as in floors, set and jointed with neat cement slurry with and including over 15 mm thick screed bedding layers of cement sand mortar (1:4) and pointed with coloured cement to match with surfaces of tiles complete all as specified and as directed. 44.00 m&l for glazed ceramic coloured tiles (colour & shade as approved) of size (450x350)mm x 7mm thick as in vertical surfaces as in skirting and dado, set and jointed in neat cement slurry with amd including over 15mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified and as directed. 45.00 s&f in repair wash hand basin, vitreous china, flat back (550x400)mm size, white including pvc waste coupling 32mm size, pvc waste pipe 32mm bore, pair of brackets of mild steel (35 x 35 x 6)mm size including one mixer cast copper alloy 15mm bore, one brass stop valve 15mm bore and one pvc connection15mm size with ptmt nuts of length 450mm long complete all as specified and as directed by engineer-in-charge. 46.00 supply & fixing in repair vitreous china ewc super constellation including flushing cistern of size (83x37x66)cm with s trap complete all as specified and as directed. 47.00 supply & fixing in repair vitreous china urinal pot white including partition, waste pipe, screw with wall fixing complete all as specified and as directed. 48.00 s&f in repairs two way wall mixer with popup waste system, hot and cold facilites and 450 mm long braidaed hoses chromium plated complete all as specified and as directed . 49.00 s&f in repair health faucet with double lock 1 meter brass plated stainless steel flexible hose and wall hook complete all as specified and as directed. 50.00 s & f in repair copper alloy cp toilet paper holder complete all as specified and as directed. 51.00 m&l for replacement of 100mm ci floor/nahani trap with grating including jointing and breaking/ dismantling any type of floor and making good cement concrete type b-1 (1:2:4) and testing after repairs and taking down existing trap etc complete all as specified and as directed. 52.00 s&f in repair, brass chromium plated tubular towel rail, 20mm dia, d type, 60cm long between flanges complete all as specified and as directed. 53.00 taking up or down 15mm steel tubing and connections in walls, ceilins, floors, etc including cleaning for refixing or removal to store complete all as specified and as directed. 54.00 m&l for gi tubing, 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors etc complete all as specified and as directed. 55.00 m&l for cutting chases, pinning in making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc, and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good cutting not exc 10 cm girth as in wall complete all as specified and as directed. 56.00 s&f in repair 15mm bore cast copper alloy, cp angle cock, screwed down, high pressure, with crutch or butterfly handles, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. 57.00 s&f in repair pvc connections 15mm size with ptmt nuts of length 450mm and fixed complete all as specified and as directed. 58.00 s&f in repairs pvc connections 15mm size with ptmt nuts of length 600 mm and fixed complete all as specified and as directed. 59.00 s&f in repair cast copper alloy cp soap dish complete all as specified and directed. 60.00 s&f in repair bib taps with wall flange 15mm bore, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. 61.00 s&f in repair pillar cock, foam flow cast copper alloy, chromium plated, fancy type, 15 mm dia, capastan heads, screwed down high pressure complete all as specified and as directed. make:- cat no 8304 of make prayyag or equivalent as per list of makes. 62.00 s&f in repair plastic water closet seat cover, white/black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. 63.00 s&f in repair pvc valveless, syphonic action type, flushing cistern low level, 10 litre capacity , white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed. 64.00 s&f in repair 610 mm long pvc waste pipe flexible type 25 mm dia suitable for couplings 32 mm / 40 mm dia complete all as specified and as directed. 65.00 s&f in repair (600 x450) mm fancy type or bevelled edge mirror of selected quality glass, mounted on 6mm thick ac building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. 66.00 s&f in repairs 15 mm bore bib taps standard of ptmt any colour high pressure screwed for iron pipe and fixed complete all as specified and as directed. (minimum weight 90 gms). 67.00 s&f in repairs 15 mm two in one angle valve cast copper alloy, chromium plated with wall flange and fancy type with high pressure screwed down and with cp flange of same make complete all as specified and as directed . 68.00 m&l for 18-20mm thick granite (of jet black ) work (table rubbed and polished ) in steps, jambs, pillars, window cills, cooking plateforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. note:- the cost of half round moulding shall be deemed to be included in unit rate. 69.00 dismantalling water tanks and removal from site of capacity exc 250 ltr and not exc 500 ltr complete all as specified and as directed. 70.00 m &l for 500 litres capacity rotational moulded polyethene water storage tank (cylindrical vertical with closed top), white, three layers, hoisted and fixed in position complete all as specified and as directed. 71.00 supply and fixed ball brass valve high pressure with polythene float and fly nut complete to bore of pipe 20mm complete all as specified and as directed. 72.00 demolition of brick work or stone buillder built in cement mortar of any description complete all as specified and as directed. 73.00 m&l for brick work with sub class b works, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete complete all specified and as directed. 74.00 dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. 75.00 s&f mild steel work such as angle iron post, flat iron in fencing including cutting as making doubble swan neck i.e. y shaped including welding with proper overlapping & welding ms plate with angle iron bottom as directed, drilling holes notching for wire etc embedded in concrete fixed vertically conforming to fe 290 grade e-165 complete all as specified and as directed. note:- embedded portion of angle iron post shall be treated with tar of coat of tar black paint and cost of the same shall be deemed to be included in unit rate. 76.00 m&l for preparation of newly steel surfaces of any description over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer of any height complete all as specified and as directed. 77.00 s&f for concertina coil with punched tape of 600 mm dia (when stretched), centre core wire of minimum 2.5 mm dia of mild steel wire conforming to is 280-2006 with galvanised coating of steel concertina coil as per requirements laid down for medium coated wire in is : 4826 hot dipped galvainsed coating of round steel wires. conretina coil shall be fixed in diamond shape with the help of dovetail two handle and spikes shall be fixed at both end of coil,minimum straight length of the wire 150 rm for 10 rm of work ,minimum weight 13.5 kg for 10 rm of work including dismantling of existing concertina coil complete all as specifed and directed by engr-in-charge. (note:- the actual weight of concertina coil brought by the contractor at site shall be ascertained by boo as ordered by ge). 78.00 s&f for concertina coil with punched tape of 900 mm dia (when stretched), centre core wire of minimum 2.5 mm dia of mild steel wire conforming to is 280-2006 with galvanised coating of steel concertina coil as per requirements laid down for medium coated wire in is : 4826 hot dipped galvainsed coating of round steel wires. conretina coil shall be fixed in diamond shape with the help of dovetail two handle and spikes shall be fixed at both end of coil,minimum straight length of the wire 180 rm for 10 rm of work ,minimum weight 16.5 kg for 10 rm of work including dismantling of existing concertina coil complete all as specifed and directed by engr-in-charge. (note:- the actual weight of concertina coil brought by the contractor at site shall be ascertained by boo as ordered by ge). 79.00 dismantling of fencing wire, barbed wire any type and description complete all as specified and as directed. 80.00 supply and fixing galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2 mm dia barbed of 75mm spacing and straining and fixing to any type of standard rail, straining bolt including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc as directed (each line wire to be measured) complete all as specified and as directed. 81.00 m&l for cuting holes in brick walls exc half brick but n.exc one brick, built in cement mortar for fixing holdfasts in jambs of existing opening and making good complete all as specified and as directed. 82.00 m&l pcc (1:3:6) type c1 (using 20 mm graded stone aggregates) as in hold fast block including necessary form work complete all as specified and as directed. 83.00 s&f mild steel work framed such as grill, gratings, etc with ends of bars shouldered and /or riveted, or forged into spikes, framed guard bars barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to fe.290.gde-e-165. complete as specified and as directed. 84.00 dismantling of fencing wire mesh, any type of any description complete as specified and as directed. 85.00 fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete as specified and as directed. 86.00 supply only chain link ms galvanised fencing, 4mm dia gi wire mesh size 100mm x 100mm complete as specified and as directed. 87.00 s&f mild steel screw bolts 12 mm dia (machine made) with hexagonal heads at one end and screwed other end to be fitted with washers (02 nos.) and one hexagonal nut, length of bolt exe 5 cm and n exe 10 cm complete as specified and as directed. 88.00 s&f mild steel fabricated round bars 10mm dia as in horizontal bars for chain link fencing incl necessary hooking at ends all as complete as specified and as directed. 89.00 excavation in post hole (or similar holes) each n.exc 0.50 cum getting out returning, filling in and ramming earth around in layers n. exc 25cm watering and removed surplus soil to a distance n. exc 50m and making good surface in soft/loose soil complete as specified and as directed. 90.00 supply and fixing in repairs, pre cast cement concrete jallies, 35 mm thick, type b0 1:2:4 (using 12.5 mm graded crushed stone aggregate) including wire fabric set and jointed in cement mortar (1:4) complete as specified and as directed. 91.00 s&f in repair aluminium composit panel (acp) sheet with 1x1.5 aluminium tube over the framed/ beam of gates. acp shall meet under mentioned technical requirements:- (i) coating on front : high quality polymer resin.(ii) core : fr core (fire retardant)(iii) thickness : 4mm(0.5 mm+3.0mm+0.5mm) (iv) weight : 7.50kg/sqm(v) width: 1200mm(vi) length: 1200 to 2400mm(vii) structure: aluminium panel are protective film,clear coating pvdf,primer coating,antirust layer,aluminium skin and polyethylene.(viii) temp resistance : between -50c to +80c(note:- the quoted rate is deemded to be included necessaryy scaffolding required and joint sealing) 92.00 s & f in repair 12mm thick toughened glass fixed with double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminum alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other party made of mild steel heavy duty and stainless steel handle purpose made on both side with locking machanism and with necessary stopper etc complete all as specified and as directed. 93.00 demolition and breaking up drain pipe 75/100mm dia ( salt glazed ware, ac or pvc) of any type complete all as specified and as directed. 94.00 s&f 75 mm dia pvc (swr) pipes single socketed in any length with rubber ring joints fixed to walls including suitable clamps after every one meter of interval complete all as specified and as directed. 95.00 s&f 110 mm dia pvc (swr) pipes single socketed in any length with rubber ring joints fixed to walls including suitable clamps after every one meter of interval complete all as specified and as directed. 96.00 s&f in repairs pvc(swr) bends any radius, 75 mm bore complete all as specified and as directed. 97.00 s&f in repairs pvc(swr) bends any radius, 110 mm bore complete all as specified and as directed. 98.00 hacking out old broken glass (any thickness, size, quality or description) from wooden frames or steel, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed. 99.00 s&f sheet glass 4mm thick ordinary quality and glazing with oil putty or rubeer bedding in square n. exc 0.5 sqm in each pane complete all as specified and as directed. 100.00 s&f in repairs of sink with drainage board, made out of stainless steel 1mm thick, kitchen or laboratory with plugs, washes and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever bracket and connecting union to pipe over all size (915x460)mm with bowl size (410x330x160)mm complete all as specified and as directed. 101.00 s&f in repair brass chromium plated shower rose,125 mm size fixed to 15 mm bore iron pipe complete all as specified and as directed. 102.00 s&f in repair water closet vitreous china squatting pan, orissa pattern size (580x440)mm white with integral foot rests (excluding flushing cistern and flush pipe) and including with p or s trap complete including provison of lime concrete bedding fixed in repair complete all as specified and as directed. 103.00 m&l for gunniting work to rcc work in column, flooring, side walls, beam, slab, etc by removing loose concrete cover etc, cleaning of surface with wire brush and applying epoxy paint to rusted reinforcement and s&f welded wire mesh fabric or wire net less than 95 x 95x 3 mm tied to existing reinforcement with nails,adhesive plaster grade for concrete and providing gunniting pressure 2.0/2.5kg/sqm with admixture 1 part of cement and 3.5 part of sand with average thickness 40 mm and making the surface even including 15mm thick plastering in cm 1:4 on brick or concrete surfaces including finishing the surfaces even and smooth, without using extra cement including necessary form work to be carried out,complete all as specified.(note.- wherever reinforcement required shall be measured and paid seperately) 4. structural steel steel authority of india limited (sail) brand: sail / rashtriya ispat nigam limited (rinl) brand: rinl / tata iron & steel company (tisco, or tata steel) brand: tata / m/sjindal steels and power ltd. brand: jindal 5 factory made paneled/ glazed /gauged door shutters m/s mp wood product indore, m/s jain doors pvt ltd sonipat, goyal industiral corporation new delhi, shri krishna industries, panchkula, 6 factory made flush door shutters m/s green ply industries, m/s centuary ply, m/s dura ply. mysore chip board, archid, swastik ply wood, m/s jain doors pvt ltd 7 pvc door frame/shutters sintex, rajshri plastiwood ltd, m/s dura plast extraction pvt ltd, m/s fenesta, ecocell,accucell 8 frp door frame and shutter selected products co., sintex, rajshri plastiwood ltd, accure polytec pvt ltd ,ecocell, fiberways 9 upvc window/doors fenesta, ncl veka, madhu industries, h2o solutions, yashpoly,accucel, okotech, aseco (m/s ashish industries) 10 iron mongery mowjee, m/s kitch architectural product pvt ltd, rs industries. 11 hydraulic door closer everest, universal, godrej 12 particle board(veneered & unveneered laminated)/ block board kitply, nova pan industries, new delhi, m/s green ply industries ltd, archid ply, bhutan board, dura board mysore chip board ltd 13 plywood for general purposes dura ply, archid ply, bhutan board,archid board, century, durian, mysore chip board ltd 14 decorative laminates archid lam, sunmica, merino, lam, mysore chip board,greelam 15 terrazzo tiles ntc, nitco, eurocon, duracrete 16 glazed ceramic/non skid wall/floor tiles kajaira, johnson, agl, qutone , somany, nitco, orient bell ,vitero, sunhearrt ceramik, varmora 17 vitrified tiles (polished, unpolished & glazed, normal/ anti skid) kajaira, johnson, agl, qutone , somany, nitco, orient bell,vitero,sunhearrt ceramik, varmora 18 hdpe storage water tanks sintex, supreme,plasto,polycon 19 sanitary appliances /fittings(chinaware) hindware,parryware,cera,jaquar, kohler, prayag aproyale,somany 20 water closet seats and cover (solid bakelite) thermostat moulded toilet seat cover parryware, jaquar, prayag somani,commander,cera,neycer 21 pvc flushing cisterns hindware, commander, parryware, cera ,jaquar, johnson pedar, neycer 22 stainless steel kitchen sink with or without draining board, plate rack nirali,cera,diamond,jainco,shakti prayag, (silver shine) m/s bluestar sanitary industries 23 ball valves (horzontal plunger type) dripless faucets india, flowjet , ball valves inida. 24 shower roses chromium plated (swivel type) gem,jaquar, jal 25 bath room fancy fittings jaquar,gem,marc, jalangi 26 bib taps and stop taps (cp),pillar tap, fancy fittings jaquar, parko, gem, marc 27 bathroom cabinets jaquar, cera, commander, parryware .... more in document
  • View Tender
  • Document
  • Bid Support
3 Power Plant
image image
corporations/Associations/Others
TRN :49056804 |  23 May, 2025
Tender Value : 18.27 Lacs
 Prayagraj - Uttar Pradesh
Tender for tender for annual civil & electrical m&r work for residential building situated at 20-clive road hydel colony, prayagraj - earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. for all kinds of soil. 2 supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 3 surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. for all kinds of soil. 4 excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 5 providing and laying in position cement concrete of grade 1:1½:3 (1 cement: 1½ coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - all work up to plinth level : 6 providing and laying in position cement concrete of grade1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - all work up to plinth level : 7 providing and laying in position cement concrete of grade 1:5:10 (1 cement : 5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - all work up to plinth level : 8 providing and laying cement concrete 1:1½:3 (1 cement: 1½ coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 9 providing and fixing up to floor five level precast cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources) string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering complete. 10 providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 11 extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. 12 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-iii) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 13 providing and laying in positiongrade 1:1.5:3 (1 cement : 1.5 coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level : 14 providing and laying in positiongrade 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level : 15 reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 16 reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 17 centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete 18 centering and shuttering including strutting, propping etc. and removal of form for walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 19 centering and shuttering including strutting, propping etc. and removal of form forsuspended floors, roofs, landings, balconies and access platform 20 centering and shuttering including strutting, propping etc. and removal of form for shelves (cast in situ) 21 centering and shuttering including strutting, propping etc. and removal of form for lintels, beams, plinth beams, girders, bressumers and cantilevers 22 centering and shuttering including strutting, propping etc. and removal of form for columns, pillars, piers, abutments, posts and struts 23 centering and shuttering including strutting, propping etc. and removal of form for stairs, (excluding landings) except spiral-staircases 24 centering and shuttering including strutting, propping etc. and removal of form for spiral staircases (including landing) 25 centering and shuttering including strutting, propping etc. and removal of form for small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 26 centering and shuttering including strutting, propping etc. and removal of form for small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like 27 centering and shuttering including strutting, propping etc. and removal of form for weather shade, chajjas, corbels etc., including edges 28 centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 29 centering and shuttering including strutting, propping etc. and removal of form for lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 30 mild steel and medium tensile steel bars for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 31 mild steel and medium tensile steel bars for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 32 smooth finishing of the exposed surface of r.c.c. work with 6 mm thick cement mortar 1:3 (1 cement : 3 fine sand). 33 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 34 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in cement mortar 1:6 (1 cement : 6 coarse sand) 35 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in cement mortar 1:6 (1 cement : 6 coarse sand) 36 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand) 37 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. cement mortar 1:4 (1 cement :4 coarse sand) 38 providing and fixing 18 mm thick granite stone slab of colour black, cherry/ruby red gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels (area of slab over 0.50 sqm) 39 providing edge moulding to 18 mm thick granite workcounters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer-in-charge. 40 extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 41 providing and fixing plywood 4 mm thick, one side decorative veneer conforming to is: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : 42 providing and fixing 4mm thick coir veneer board, isi marked is : 14842, plain lining with necessary screws, priming coat on unexposed surface etc., complete. 43 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 44 providing second class teak wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 45 providing and fixing 2nd class teak wood size 50x12 mm moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 46 providing and fixing second class teak wood panelled or panelled and glazed 30 mm thick shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of engineer-in-charge. (note:- butt hingesand necessary screwsshall be paid separately) 47 providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 48 providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with isi, is : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 49 providing and fixing30mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with isi marked m.s. pressed butt hinges bright finished of required size with necessary screws.(kiln seasoned and chemically treated hollock wood) 50 providing and fixing35mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with isi marked m.s. pressed butt hinges bright finished of required size with necessary screws.(kiln seasoned selected planks of sheesham wood) 51 providing and fixing30mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with isi marked m.s. pressed butt hinges bright finished of required size with necessary screws.(kiln seasoned selected planks of sheesham wood) 52 providing and fixing30mm thick panelled or panelled & glazed shutters for cup board using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with isi marked m.s. pressed butt hinges bright finished of required size with necessary screws.(second class teak wood including isi marked anodised aluminium butt hinges with necessary screws) 53 providing and fixing isi marked 35mm thick flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including isi marked stainless steel butt hinges with necessary screws) 54 providing and fixing isi marked 30mm thick flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including isi marked stainless steel butt hinges with necessary screws) 55 providing and fixing isi marked 35mm thick flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including isi marked stainless steel butt hinges with necessary screws) 56 extra for providing and fixing flush doors with on one side only decorative veneering instead of non decorative isi marked flush door shutters conforming to is: 2202 (part i) 57 providing and fixing 12mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with c.p. brass screws andpvc sleeves etc., wherever necessary complete : 58 providing and fixing 20mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with c.p. brass screws andpvc sleeves etc., wherever necessary complete : 59 providing and fixing 25mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with c.p. brass screws andpvc sleeves etc., wherever necessary complete : 60 providing and fixing 20mm dia (heavy type) nickel plated m.s. pipe curtain rods with nickel plated brackets : 61 providing and fixing 25mm dia (heavy type) nickel plated m.s. pipe curtain rods with nickel plated brackets : 62 providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. 63 providing and fixing 125x65x2.12 mm isi marked is:1341 oxidised m.s. pressed butt hinges with necessary screws etc. complete. (copper oxidised as per is 1378) 64 providing and fixing 100x58x1.90 mmisi marked is:1341 oxidised m.s. pressed butt hinges with necessary screws etc. complete. (copper oxidised as per is 1378) 65 providing and fixing 75x47x1.70 mmisi marked is:1341 oxidised m.s. pressed butt hinges with necessary screws etc. complete. (copper oxidised as per is 1378) 66 providing and fixing 50x37x1.50 mmisi marked is:1341 oxidised m.s. pressed butt hinges with necessary screws etc. complete. (copper oxidised as per is 1378) 67 providing and fixing 150 mm isi marked oxidised m.s. single acting spring hinges with necessary screws etc. complete (copper oxidised as per is 1378) 68 providing and fixing 125 mm isi marked oxidised m.s. single acting spring hinges with necessary screws etc. complete (copper oxidised as per is 1378) 69 providing and fixing 100 mm isi marked oxidised m.s. single acting spring hinges with necessary screws etc. complete (copper oxidised as per is 1378) 70 providing and fixing 250x16 mm isi marked oxidised m.s. sliding door bolts with nuts and screws etc. complete (copper oxidised as per is 1378) 71 providing and 250x10 mm fixing isi marked oxidised m.s. tower bolt black finish, (barrel type) with necessary screws etc. complete (copper oxidised as per is 1378) 72 providing and 200x10 mm fixing isi marked oxidised m.s. tower bolt black finish, (barrel type) with necessary screws etc. complete (copper oxidised as per is 1378) 73 providing and 150x10 mm fixing isi marked oxidised m.s. tower bolt black finish, (barrel type) with necessary screws etc. complete (copper oxidised as per is 1378) 74 providing and 100x10 mm fixing isi marked oxidised m.s. tower bolt black finish, (barrel type) with necessary screws etc. complete (copper oxidised as per is 1378) 75 providing and fixing isi marked 85x42 mm oxidised m.s. pull bolt lock conforming to is : 7534 with necessary screws bolts, nut and washers etc. complete (copper oxidised as per is 1378). 76 providing and fixing 125 mm isi marked oxidised m.s. handles conforming to is:4992 with necessary screws etc. complete (copper oxidised as per is 1378) 77 providing and fixing 100 mm isi marked oxidised m.s. handles conforming to is:4992 with necessary screws etc. complete (copper oxidised as per is 1378) 78 providing and fixing 75 mm isi marked oxidised m.s. handles conforming to is:4992 with necessary screws etc. complete (copper oxidised as per is 1378) 79 providing and fixing 150 mm oxidised m.s. hasp and staple (safety type) conforming to is : 363 with necessary screws etc. complete (copper oxidised as per is 1378) 80 providing and fixing 115 mm oxidised m.s. hasp and staple (safety type) conforming to is : 363 with necessary screws etc. complete (copper oxidised as per is 1378) 81 providing and fixing 90 mm oxidised m.s. hasp and staple (safety type) conforming to is : 363 with necessary screws etc. complete (copper oxidised as per is 1378) 82 providing and fixing 300 mm (weighing not less than 330 grams) oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete (copper oxidised as per is 1378) 83 providing and fixing 125mm special quality bright finished brass handles with screws for cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 84 providing and fixing 100mm special quality bright finished brass handles with screws for cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 85 providing and fixing 75mm special quality bright finished brass handles with screws for cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 86 providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 87 providing and fixing triple strip vertical type magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. 88 providing and fixing double strip (horizontal type) magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. 89 providing and fixing factory made upvc door frame made of upvc extruded sections having an overall dimension as below (tolerance ±1mm),with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. the hinge side vertical of the frames reinforced by galvanized m.s. tube of size 19 x 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of engineer- in-charge (extruded section profile size 48x40 mm) 90 providing and fixing factory made upvc door frame made of upvc extruded sections having an overall dimension as below (tolerance ±1mm),with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. the hinge side vertical of the frames reinforced by galvanized m.s. tube of size 19 x 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of engineer- in-charge (extruded section profile size 42x50 mm) 91 providing and fixing 12 mm thick fire retardant plywood conforming to is: 5509 panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. 92 providing and fixing cup board shutters 25 mm thick, with pre-laminated flat pressed three layer particle board or graded wood particle board is: 12823 marked, exterior grade (grade l type ll), having one side decorative lamination and other side balancing lamination, including iind class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the engineer-in-charge 93 providing and fixing aluminum u beading of required size to pre-laminated/flush door shutter, including fixing etc. complete as per direction of engineer-in-charge. 94 providing and fixing casement handle made of zinc alloyed (white powder coated) for upvc casement window with necessary screws etc. complete. 95 providing and fixing zinc alloyed (white powder coated) touch lock for upvc sliding window with necessary screws etc. complete. 96 providing and fixing steel roller for upvc sliding window with necessary screws etc. complete. 97 providing and fixing steel roller for upvc sliding door with necessary screws etc. complete. 98 providing and fixing steel (white power coated) crescent lock for upvc sliding window/ door with necessary screws etc. complete. 99 providing and fixing 18mm thick both sides pre-laminated cement bonded wood particle board as per is : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of engineer-in-charge (note: fittings to be paid separately). 100 providing and fixing 6mm thick both sides pre-laminated cement bonded wood particle board as per is : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. on the backing of racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of engineer-in-charge. 101 providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed bwp grade marine ply as per is 710 of approved brand including 2mm thick pvc edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of engineer-in-charge.(payment of providing and fixing auto closing hinges shall be paid separately) 102 structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 103 providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of t-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 104 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6 mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.(using m.s. angels 40x40x6 mm for diagonal braces) 105 providing and fixing stainless steel ( grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 106 providing and fixing angle iron frames for doors, windows and ventilators of mild steel angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing t-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of engineer-in-charge. 107 brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar with 1:6 (1cement : 6 coarse sand) including filling the joints with same mortar, with common burnt clay non modular bricks: 108 dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with jamuna sand, with common burnt clay non modular bricks. 109 40 mm thick with 20 mm nominal size stone aggregate cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 110 18 mm thick cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 111 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 112 cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. 113 25 mm thick kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 114 deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm. 115 fixing glazed/ ceramic/ vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (water based) conforming to is: 15477, in average 3mm thickness. 116 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 117 providing and fixing 1st quality ceramic glazed floor tiles conforming to is : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 118 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to is : 15622, of approved make, in all colours, shades, except white, ivory, grey, fume red brown, laid on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. 119 providing and laying vitrified floor tiles size 600x600 mm(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. 120 providing 1 mm thick with zinc coating not less than 275 gm/ m² corrugated g.s. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 121 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 122 providing & fixing 0.56 mm, aluminium color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm at all heights, levels and locations colour finish aluminium alloy roofing sheets of alloyis designation31500, temper hx8 conforming to is 737 and dimensions as per is code 2676 with characteristics of good formability and corrosion resistance. the profile sheets shall be fixed to truss members in slope or required pitch or curvature with hex cap headed self drilling/tapping stainless steel screws m6, 50 mm long with 3 mm epdm seal washer etc. all inclusive of labour, scaffolding, t&p and sundries etc. complete as per directions of the engineer-in-charge. (cost of truss/frame work shall be paid separately). 123 providing and fixing precoated/mill finish aluminium ridges plain (500- 600mm) of pre-coated colour or mill finishaluminium roofing accessories in 0.71 mm thickness ,alloy 31500 (is designation) [aluminium alloy (aa) 3004 (iso designation)]for color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping ss screws of size 6 x 50mm with 3mm thick epdm seal and ss plain washer complete : 124 providing 10 mm thick plaster of paris (gypsum anhydrous) flat surfaces ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): 125 12.5 mm thick fully perforated gypsum board tile made from plasterboard having glass fibre conforming to is: 2095 part i, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an nrc (noise reduction coefficient) of 0.79, with 50 mm resin bonded glass wool backing. 126 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) 127 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) 128 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) 129 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) 130 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 131 neat cement punning. 132 distempering with 1st quality acrylic distemper (ready mixed) new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than50 gram/litre of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 133 finishing walls for new work (two or more coats applied @ 3.84 kg/10 sqm) with water proofing cement paint of required shade : 134 finishing walls for new work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) with acrylic smooth exterior paint of required shade : 135 finishing walls for new work (two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. with ready mixed premium acrylic emulsion paint (company depot tinted) having voc less than 50 gm/litre and uv resistance as per is 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. 136 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 137 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 138 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) 139 painting (two or more coats) on 100mm diameter rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. 140 painting (two or more coats) on 150mm diameter rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. 141 painting two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 142 polishing on new wood work with ready mixed wax polish of approved brand and manufacture : 143 lettering with black japan paint of approved brand and manufacture 144 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 145 distempering for old work (one or more coats) with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturerincluding applying additional coats wherever required to achieve even shade and colour 146 applying priming coats with water thinnable cement primer on wall surface having voc content less than 50 grams/litre of approved brand and manufacture. 147 6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of engineer-in-charge. 148 removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 149 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 150 polishing on old wood work with ready made wax polish of approved brand and manufacture : 151 painting (one or more coats) with black japan paint of approved brand and manufacture to give an even shade. 152 finishing walls for old work (two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface with acrylic smooth exterior paint of required shade : 153 repairs to plaster of thickness 12 mm to 20 mm with cement mortar 1:4 (1 cement : 4 fine sand) in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of engineer-in-charge. 154 fixing door chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of engineer-in-charge. 155 fixing chowkhat in existing opening in brick/ rcc wall with dash fasteners/chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including cost of dash fasteners/ chemical fastener. 156 making the opening for door/ window/ clerestory window in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of engineer-in-charge. 157 renewing float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) with putty and nails wherever necessary including racking out the old putty: 158 renewing float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) with putty and nails wherever necessary including racking out the old putty: 159 renewal of old putty of glass panes (length) 160 refixing old glass panes with putty and nails 161 fixing old glass panes with wooden fillets (excluding cost of fillets) 162 renewing bottom rail and/or top runner of collapsible gate including making good all damages and applying priming coat of zinc chromate yellow primer of approved brand and manufacturer. 163 pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. 164 providing and fixing 20 mm diameter. brass curtain rods ofwall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. 165 repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modifiedself curing mortar, including disposal of rubbish, all completeas per the direction of engineer-in-charge. 166 cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of engineer-in-charge. 167 disconnecting damaged overhead/terrace pvc water storage tankof any size from water supply line and removing from the terrace including shifting at ground level as per direction of engineer-in-charge. 168 providing & fixing orissa pattern w.c pan of size 580x440 mm white vitreous china water closet squatting pan (indian type) along withs or p trap including dismantling of old wc seat and s or p trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of engineer-in charge. 169 dismantlingw.c.pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in-charge. 170 dismantling 15 to 40 mm dia g.i. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of engineer-in-charge.(a) internal work- exposed on wall 171 taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the engineer-in-charge. 172 demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of engineer- in-charge. 173 demolishing nominal cementconcrete 1:3:6 or richer mix (i/c equivalent design mix manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 174 demolishing nominal cementconcrete 1:4:8 or leaner mix (i/c equivalent design mix manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 175 demolishing r.c.c. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of engineer - in- charge. 176 demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 177 removing mortar from bricks in from brick work in cement mortar and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): 178 dismantling doors, windows and clerestory windows (steel or wood) shutter of area 3 sq. metres and below including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 179 dismantling doors, windows and clerestory windows (steel or wood) shutter of area beyond 3 sq. metres including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 180 taking out doors, windows and clerestory window shutters (steel or wood) of area 3 sq. metres and belowincluding stacking within 50 metres lead : 181 taking out doors, windows and clerestory window shutters (steel or wood) of area beyond 3 sq. metres including stacking within 50 metres lead : 182 dismantling for thickness of tiles 10 mm to 25 mmwork in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 183 dismantling for thickness of tiles above 25 mm and up to 40 mmwork in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 184 demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : 185 dismantling g.s. sheetroofingincludingridges,hips,valleysandguttersetc., and stacking the material within 50 metres lead of: 186 dismantling asbestos cement sheetroofingincludingridges,hips,valleysandguttersetc., and stacking the material within 50 metres lead of: 187 dismantling tiled roofing with battens, boarding etc. complete includingstackingofserviceablematerialanddisposalofunserviceable material within 50 metres lead. 188 dismantlingbarbedwireorflexiblewireropeinfencingincludingmaking rolls and stacking within 50 metres lead. 189 dismantling40 mm thick precast concrete orstone slabsin walls, partition walls etc. including stacking within 50 metres lead : 190 dismantling40 mm to 75mmthick precast concrete orstone slabsin walls, partition walls etc. including stacking within 50 metres lead : 191 dismantling cement asbestos or other hard board ceiling or partition wallsincludingstackingofserviceablematerialsanddisposalof unserviceable materials within 50 metres lead. 192 dismantling of flushing cistern of all types(c.i./pvc/vitrious china) includingstackingofusefulmaterialsnearthesiteanddisposalofunserviceable materials within 50 metres lead. 193 dismantling old plaster or skirting raking out joints and cleaning the surfaceforplasterincludingdisposalofrubbishtothedumping ground within 50 metres lead. 194 dismantlingaluminium/gypsumpartitions,doors,windows,fixed glazing and false ceiling including disposal of unserviceable material andstackingofserviceablematerialwithin50metersleadas directed by engineer-in-charge. 195 disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping groundorasapprovedbyengineer-in-charge,beyond50minitial lead, for all leads including all lifts involved. 196 cuttingroadandmakinggoodthesameincludingsupplyofextra quantities of materials i.e. aggregate, moorum screening, red bajri and labour (required.bituminous portion) 197 paintingroadsurfacemarking for new work (two or more coats) withadequatenosofcoatstogive uniform finish with ready mixed road marking paint conforming to is : 164, on bituminous surface in white/yellow shade, including cleaning thesurfaceofalldirt,scales,oil,greaseandforeignmaterialetc. complete. 198 paintingroadsurfacemarking for old work (one or more coats) withadequatenosofcoatstogive uniform finish with ready mixed road marking paint conforming to is : 164, on bituminous surface in white/yellow shade, including cleaning thesurfaceofalldirt,scales,oil,greaseandforeignmaterialetc. complete. 199 taking out existing cc interlocking paver blocks from footpath/ central verge,includingremovalofrubbishetc.,disposalofunserviceable materialtothedumpingground,forwhichpaymentshallbemade separately and stackingof serviceable materialwithin 50metre lead as per direction of engineer-in-charge. 200 layingoldcementcocreteinterlockingpaverblocksofanydesign/ shapelaidinrequiredline,level,curvature,colourandpatternover and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer- in-charge. (old cc paver blocks shall be supplied by the department free of cost). 201 providing and laying 80mmthickc.c.paverblockofm-35gradewith approved colour design and pattern.factory made chamfered edge cement concrete paverblocksinfootpath,parks,lawns,drivewaysorlighttraffic parkingetc,ofrequiredstrength,thickness&size/shape,madeby tablevibratorymethodusingpumould,laidinrequiredcolour& patternover50mmthickcompactedbedof sand,compactingand properembedding/layingofinterlockingpaverblocksintothesand beddinglayerthroughvibratorycompactionbyusingplatevibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. completeall as per direction of engineer-in-charge. 202 providing andfixingwhitevitreouschinaorissapatternw.c.panofsize 580x440 mm with integral type foot rests waterclosetsquatting pan(indian typew.c. pan)with100mmsandcastironporstrap,10litrelowlevel whitep.v.c.flushingcistern,includingflushpipe,withmanually controlleddevice(handlelever)conformingtois:7231,withall fittingsandfixturescomplete,includingcuttingandmakinggood the walls and floors wherever required: 203 providing and fixing w.c. pan with isi marked white solid plastic seat and lid white vitreous china pedestal type water closet (european type) with seat and lid, 10 litre low level white vitreous china flushing cistern & c.p. flush bend with fittings & c.i. brackets, 40 mm flush bend, overflow arrangement with specials of standard makeandmosquitoproofcouplingofapprovedmunicipaldesign complete,includingpaintingoffittingsandbrackets,cuttingand making good the walls and floors wherever required : 204 providingandfixing oneurinalbasinwith5litrewhitep.v.c.automaticflushing cistern whitevitreouschinaflatbackorwallcorner typelippedfronturinalbasinof430x260x350mmand 340x410x265 mm sizes respectively with automatic flushing cistern withstandardflushpipeandc.p.brassspreaderswithbrass unions and g.i clamps complete, including painting of fittings and brackets,cuttingandmakinggoodthewallsandfloorswhereverrequired : 205 providingandfixingwhitevitreouschinawashbasinsize550x400mm with a pair of 15 mm c.p. brass pillar taps washbasinwithc.i.brackets,15mmc.p. brasspillartaps,32mmc.p.brasswasteofstandardpattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 206 providing and fixing wash basin with c.i. brackets, 15 mm dia cp brasssingleholebasinmixerofapprovedqualityandmake, including painting of fittings and brackets, cutting and making goodthe walls wherever required:- (a)white vitreous china wash basin size 550x400 mm with a 15 mm cp brass single hole basin mixer 207 providingandfixingwhitevitreouschinapedestalforwashbasin completelyrecessedatthebackforthereceptionofpipesand fittings. 208 providing and fixing 610x510 mm bowl depth 200 mm stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required (kitchen sink without drain board) 209 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer - in - charge. 210 providing and fixing 10 litre capacity - white p.v.c. low level flushing cistern with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete. 211 providing and fixing 10 litre (full flush) capacity-white controlled flush, low level cistern made of vitreous china with all fittings complete. 212 providing and fixing g.i. inlet connection for flush pipe connecting with w.c. pan. 213 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer-in-charge. 214 providing and fixing15 mm nominal dia cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge. 215 providingandfixing 32mm diaflexible pipe p.v.c.wastepipeforsinkorwashbasin including p.v.c. waste fittings complete. 216 providing and fixing 100 mm sand cast iron grating for gully trap. 217 providingandfixinginposition25mmdiametermosquitoproofcoupling of approved municipal design. 218 providing and fixing 600x450 mm beveled edge mirror of superior glass(ofapprovedquality)completewith6mmthickhardboard ground fixed to wooden cleats with c.p. brass screws and washerscomplete. 219 providing andfixing circular shape 450 mm dia mirrorofsuperiorglass(ofapprovedquality)andofrequiredshapeandsizewithplasticmouldedframeof approved make and shade with 6 mm thick hard board backing : 220 providing andfixing 600x120x5 mmglass shelfwith edges round off, supported on anodised aluminium angle frame with c.p. brass bracketsandguardrailcompletefixedwith40mmlongscrews, rawl plugs etc., complete. 221 providing and fixing c.p. brass toilet paper holder : 222 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 223 providing and fixing ptmt towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 224 providing and fixing ptmt 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 225 providing and fixing ptmt 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 226 providing and fixing ptmt shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. 227 providing and fixing ptmt 15 mm urinal spreader size 95x69x100 mm with 1/2 bsp thread and shapes, weighing not less than 60 gms. 228 providing and fixing 15 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. (internal work - exposed on wall) 229 providing and fixing 20 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. (internal work - exposed on wall) 230 providing and fixing 25 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. (internal work - exposed on wall) 231 providing and fixing 15 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.(concealed work) 232 providing and fixing 20 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.(concealed work) 233 providing and fixing 25 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.(concealed work) 234 providing and fixing 15 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 235 providing and fixing 20 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 236 providing and fixing 25mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 237 providing and fixing 32mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 238 providing and fixing 40mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 239 providing and fixing 50mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 240 providing and fixing 15 mm dia nominal bore g.i. pipes complete with g.i. fittings and clamps, i/c cutting and making good the walls etc.(internal work - exposed on wall) 241 providing and fixing 20 mm dia nominal bore g.i. pipes complete with g.i. fittings and clamps, i/c cutting and making good the walls etc.(internal work - exposed on wall) 242 providing and fixing 25 mm dia nominal bore g.i. pipes complete with g.i. fittings and clamps, i/c cutting and making good the walls etc.(internal work - exposed on wall) 243 providing and fixing 15 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 244 providing and fixing 20 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 245 providing and fixing 25 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 246 providing and fixing 32 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 247 providing and fixing 40 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 248 providing and fixing 50 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 249 providing and fixing 25 mm nominal bore gun metal gate valve with c.i. wheel of approved quality (screwed end) : 250 providing and fixing 20 mm nominal bore gun metal gate valve with c.i. wheel of approved quality (screwed end) : 251 providing and fixing 32 mm nominal bore gun metal gate valve with c.i. wheel of approved quality (screwed end) : 252 providing and fixing 15 mm nominal bore ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 253 providing and fixing 20 mm nominal bore ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 254 providing and fixing 15mm norminal bore 45 cm length uplasticised pvc connection pipe with brass unions : 255 providing and fixing 20mm norminal bore 45 cm length uplasticised pvc connection pipe with brass unions : 256 providing and fixing 100 mm diameter c.p. brass shower rose with 15 or 20 mm inlet : 257 providing and fixing 150 mm diameter c.p. brass shower rose with 15 or 20 mm inlet : 258 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 259 providing and fixing 15 mm nominal bore c.p. brass bib cock of approved quality conforming to is:8931 : 260 providing and fixing 15 mm nominal bore c.p. brass long nose bib cock of approved quality conforming to is standards and weighing not less than 810 gms. 261 providing and fixing 15 mm nominal bore c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 262 providing and fixing 15mm nominal bore c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 263 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 264 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 265 providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to is: 1868, minimum anodic coating of grade ac 15) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer-in-charge. (glazing, paneling and dash fastenersto be paid for separately) :(for fixed portion) 266 providing and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer-in-charge. (glazing, paneling and dash fastenersto be paid for separately) :(for fixed portion) 267 providing and fixing glazing with float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (cost of aluminium snap beading shall be paid in basic item): 268 providing and fixing glazing with float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (cost of aluminium snap beading shall be paid in basic item): 269 providing and fixing glazing with float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (cost of aluminium snap beading shall be paid in basic item): 270 providing and fixing with stainless steel cover plate minimum 1.25 mm thicknessdouble action hydraulic floor spring of approved brand and manufacture conforming to is : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece m.s. sheet outer box with slide plate etc. complete as per the direction of engineer-in-charge. 271 providing and fixing with brass cover plate minimum 1.25 mm thicknessdouble action hydraulic floor spring of approved brand and manufacture conforming to is : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece m.s. sheet outer box with slide plate etc. complete as per the direction of engineer-in-charge. 272 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. this layer will be allowed to air cure for 4 hours.(b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) 273 providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of fibre glass cloth when the first layer is still green. overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. this will be allowed to air cure for 4 hours followed by water curing for 48 hours. the entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. (for the purpose of measurement the entire treated surface will be measured.) 274 providing & applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer(dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of engineer-in-charge. 275 providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of rcc structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. after cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. over the primed surface swellable type water stop tape shall be placed. the work shall be carried out all complete as per specification and the direction of the engineer-in-charge. the product performance shall carry guarantee for 10 years against any leakage. 276 providing and fixing with15mmthick fullyperforatedsquare/buttedgelightweightcalcium silicate panels/ tiles in position wall panelling at all heights with integral densified calcium silicatepanels/tilesofsize595x595mm,havingnrc(noisereductioncoefficient)of0.50 (minimum) as per is 8225:1987, light reflectance of 85% (minimum). non combustible as per bs:476 (part-4), fire performance as per bs:476 (part 6 &7), humidity resistanceof 100%,thermalconductivity<0.043w/mk asperastm518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mmthickpressedsection(galvanizing@120gramspersqmincludingbothsides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor andceilingchannel sectionofsize50x32mfixedtothefloorandsoffitat600mm centersusing12mmdia,50mmlongwedgetypeexpandedzincalloy dashfastnerwith 10mm bolt. this same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. glasswool of 50mm thickness is then to be inserted in the slots and finallycalcium silicate non combustible panels/tiles are to bescrew fixed withselftapping panheadnickel coatedmild steelscrewsofsize13x3.2mmon tothisgridleavingan evengroove of1 mm betweenthepanels. the joints betweenthepanelsaretobedulyjointedandfinishedusingrecommendedjointing calcium silicate based compound and fiber joint tape roll 50mm wide(90 metre )roll and twocoatsofprimersuitableforpanellingaspermanufacturersspecificationasper direction of engineer-in-charge all complete. 277 providing and fixing with 16 mm thick beveled tegular mineral fibre false ceiling tile (nrc 0.55 to 0.6 mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance (rh) of 99%,lightreflectance=85%,thermalconductivityk=0.052-0.057w/mk,fire performance as per (bs 476 pt - 6 &7)in true horizontal level suspended on interlocking t- grid of hot dipped all round galvanized iron section of 0.33 mmthick (galvanized @120 gsm)comprisingofmaintrunnersof15x32mmoflength3000mm,crosstofsize 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length600mm toform gridmoduleofsize 600x600mm suspendedfrom ceiling using galvanizedmildsteelitem(galvanised@80gsm)50mmlong8mmouterdiameterm-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l- shapeleveladjusterofsize85x25x2mm,spacedat1200mmcentretocentrealong main‘t’.thesystemshouldrestonperipherywalls/partitionswiththehelpofgi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thicksheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry walls.s. screws. the exposed bottom portion of all t-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. the work shall be carriedoutasperspecifications,drawingsandasperdirectionsoftheengineer-in- charge. 278 providingandfixingharddrawnsteelwirefabricofsize75x25mmmeshorother suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of l shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by engineer-in-charge. 279 fillingofjointsbetweenrccplinthbeam/floorslabandwallpanelofexternalwalls, toilet / bath room / wet areas walls on all floor and parapet wall over roof slab, stair case headroomatthetimeoferectionofgfrgpanelswithgroutrw/equivalentsealant compound after the erection of panelbeforethe infill of concrete in panel cavities and fine finish. this applies for all horizontal and vertical joints between gfrg wall and slab panels. 280 waterproofingtreatmentofverticaljoints(ofexternalsideandinternalside)between doorframe,window&ventilatorframes(onallfoursides)ofouterwalloverthe zycosil/equivalent & zycoprime/equivalent solution already applied (before the installation of door / window / ventilator frames in position) and fine finish with grout rw/equivalent. 281 waterproofingtreatmentofrccsunshadewith zycosil/equivalentwaterproofing solution(1litreofzycosil/equivalent&20litresofwaterstirredfirst&2litresof zycoprime/equivalent addedandstirred (total23litres))till itmeetsthesaturationlevel and testing as per rilem or bywater drops test in which water drops do not absorb but drops remain or rolls. 282 in-filling / sealing of joint between rcc lintel cum sunshade and wall (on external side) in all floors by pushing in grout rw/equivalentin paste form and coving 20 mm x 20 mm after applying a coat of zycosil/equivalent & zycoprime/equivalent solution before cement plastering of top, bottom and sides of rcc sunshade. 283 concreteworkwith40mmgaugebrickballastobtainedfrombreaking brick bats (brick bats supplied by the department free of cost) in proportion of 12:6:1 as in csi no. 5.01 includingcost of all labour, materials, t&p etc required for proper completion of work. 284 brickworkinfoundation&plinthwitholddismantled bricks(suppliedby departmentfreeofcost)andcoarsesand mortarin1:6includingsupply ofallothermaterials,labour,removingmortar&cleaningofold&usedbricks,t&p etc complete. 285 supply and filling brick bat in soak pit including all labour,material and t&petc complete. (for 01 soak pit) 286 supplying & fixing 24 gauge annodized aluminium sheet of approved qualityincludingcutting,wastageandfixingthesameoverthewooden door shutters with nails with all material, labour and t&p 287 providingandfixinginplaceafullheightstoragecabinet450mmdeep made with19 mm thick isi marked plyborad, allinterior surfaces to finishedwithpastingof0.8mmthickmicaandallexteriorsurfacestobe finshed with pasting of 1 mm thick mica of texture and colour as approved byengineerinchargeincludingalllabour,t&p,otheritemslike(butnot limitedto)fevicol,nailsscrews,higes,sliders,doorhandles,multipurpose lockofgodrejorequivalentrateetc.requiredforpropercompletionof works, to be measured interms of front area only. 288 providingandfixingfullheightpartitionwith02nos12mmthickisi marked ply board, all surfaces to finished withf 1 mm thick mica of texture andcolourasapprovedbyengineerinchargeandfixedinpolishedteak woodincludingalllabour,t&p,otheritemslike (butnot limitedto) fevicol, nailsscrews,hinges,sliders,doorhandles,multipurposelockofgodrejor equivalent rate etc. required for proper completion of works, to be measured interms of front area only 289 providingandfixing12mmthickframelesstoughenedglassdoorshutter ofapprovedbrandandmanufacture,includingprovidingandfixingtop& bottom pivot & double acting hydraulic floor spring type fixing arrangement ,doorhandle,lockandstopperetcandmakingnecessaryholesetc.for fixingrequireddoorfittings,allcompleteasperdirectionofengineer-in- charge 290 supply and fixing 6mm thick polycarbonate multiwall sheet ,fixing in position with j or u bolts 10 mm. dia with g.i. limpet & bitumen washers including supply of all materials, labour,wastage. and t&p etc. required for proper completion of the work. 291 providing (12x15) mm section groove in plasterincluding all material, labour andt&p etc. required for proper completion of the work.csi no.11.16 292 2.5 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and t&p etc, required for proper completion of the work. without base cccsi no.12.26 293 4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and t&p etc, required for proper completion of the work. without base cc csi no. 12.28 294 dismantling ofdry b.o.e. floor and proper stacking of dismantled bricks as per direction of e/c. up to 60 m lead. 295 dismantling and re-laying of dry b.o.e. floor including cost of all labour and t&p required forproper completion of work.(labour rates only) 296 cleaning panes of glass with spirit of caustic soda including supply of all materials,labour and t&p etc.required for proper completion of the work. 297 cleaning of septic tank including disposal of waste out side the uppcl area as per direction of the engineer-in-charge including cost of all labour,t&p etc.required for proper completion of the work. 298 cleaning and opening of chocked w.c./ bath / kithchen pipe line including opening and refixing of chamber cover including washing etc. complete.(analysis based on nbo - 11 25.020. 299 s/laying chicken mesh of (20 mm.)hexagonal heavy quality over roofs of joints of roof as per direction of the engineer - in - charge. 300 cleaning of existing pipe line of different dia. ranging from 4 to 2 dia. including digging trenches and refilling, opening of pipes, cleaning of pipes, cutting, threading, if required fixing and including making good the road, wall etc as directed by the engineer i/c. 301 cleaning of existing water pipe line of different dia up to 2 dia including digging trenches and refilling,opening and cleaning of pipes,cutting,threading,if required fixing and including making good the road and wall etc. as directed by the engineer in charge. 302 cleaning of r.c.c. over head tank up to capacity of one lac. liters and chlorinating with bleaching power mixed to water as per direction of engineer - in - charge complete. 303 supply and mixing bleaching powder in over head tank as required or as directed by engineer - in - charge. 304 attending to petty maintenance service like plumbingservice,welder service, mansion service and carpenter servicerequired as below. (job attending by one no. plumber/welder/mason /carpenter with oneno. helper per hour or part of an hour.) 305 cleaning and sweeping of roof of residence as and when requiredincluding uprooting of rank vegetation and disposal of thegarbage upto 50 m. 306 providing and fixing of 150 mm dia pvc pipeof 6 kg/sqcmwith special such as tee, bend, socket, elbow etc including supply of all labour,material,t & p etc complete required for proper completion of work. 307 providing and laying 75 mm dia. swr, pvc ( finolex or equivalent ) pipe including cost of excavation, c.c etc including its jointing and connection, all materials, labour and t&p etc. required for proper completion of the work. 308 providing and laying 90 mm dia. swr, pvc ( finolex or equivalent ) pipe including cost of excavation, c.c etc including its jointing and connection, all materials, labour and t&p etc. required for proper completion of the work. 309 providing and laying 110 mm dia. swr, pvc ( finolex or equivalent ) pipe including cost of excavation, c.c etc including its jointing and connection, all materials, labour and t&p etc. required for proper completion of the work. 310 making arrangement for sweeping, cleaning of road, lanes in back of houses,collecting refuse of bushes & unwanted plants, vegetations etc. & disposal of all rubbish, materials industbins inside the colony area with engaging atleast one number of sweepers including all labour, t&p,etc.required for completion of work as directed by e/i. 311 making arrangement for sweeping, cleaning of ee,ecd(d), georgetown ,prayagraj office rooms, cleaning of dustbin, toilets , dusting of almirahs,tables etc. using phenyle,dusting cloth etc. and disposal of waste outside office premise in municipal dustbinswith engaging sufficient number ofsweepersincluding all labour, t&p,etc.required for completion of work as directed by e/i.(nsi)(consumable items as phenyle,dusting cloth ,brooms etc shall be provided by the department free of cost.) 312 cleaning of main drain or width more than 300mm including disposal of waste refuses studge out side the boards ara including washing and cleaning by clean water completely as per direction of the e/i. including cost of all labour, t&p etc. required for completion of the work. (csino.20.14) 313 cleaning of main drain or width less than 300mm including disposal of waste refuses studge out side the boards ara including washing and cleaning by clean water completely as per direction of the e/i. including cost of all labour, t&p etc. required for completion of the work. (csino.20.15) nsi sl. no.63 314 operation of tube well daily by a suitable experienced operator continously or in different intervals as per program as per program fixed by engineer-in-charge including opening and closing of valves,changing of fuse wire etc. as requrird for proper running of tube well. (nsi) 315 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc as required..group c 316 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet 317 supplying and fixing of 20 mm of medium class pvc conduit along with accessories in surface/recess including junction box, cutting the wall and making good the same in case of recessed conduit as required. 318 supplying and fixing of 25 mm of medium class pvc conduit along with accessories in surface/recess including junction box,cutting the wall and making good the same in case of recessed conduit as required. 319 wiring for circuit/ submain wiring with 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 320 wiring for circuit/ submain wiring with 2 x 4 sq. mm + 1 x 4 sq. mm earth wire of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 321 wiring for circuit/ submain wiring with2 x 6 sq. mm + 1 x 6 sq. mm earth wire of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 322 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required . 323 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 324 supplying and fixing 5 amps to 32 amps rating,single pole, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 325 supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 326 supplying and fixing 40 amps, double pole, 240 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 327 supplying and fixing 4 way (4 + 12), double door, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 328 supplying and fixing of 4 way (4 + 12), double door surface/ recess mounting, vertical type, 415 volts, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs (but without mcbs and incomer ) as required . (note : vertical type mcb tpdb is normally used where 3 phase outlets are required.) 329 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit along with 1 no 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 330 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module (75mmx75mm) 331 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required.3 module (100mmx75mm) 332 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 4 module (125mmx75mm) 333 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 6 module (200mmx75mm) 334 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 8 module (125mmx125mm) 335 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 12 module (200mmx150mm) 336 supplying and drawing following 3 x 2.5 sq. mm sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 337 supplying and drawing following 3 x 4 sq. mm sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required.(dsr e&m 2022 1.17.21) 338 rewinding of burnt ceiling fan with approved copper wire including cost of all materials, labour and t&p etc. complete (burnt wirewill not be taken back.) 339 greasing of ceiling fan after cleaning the bearing and shaft withoil / petrol and its testing. 340 supply and fixing of led tube light batten fitting suitable for up to 1 x 22 watt led tube light on surface complete in all respect.(csi no. 28.41) 341 supply of 9 watt led bulb make philips, syska, bajaj etc or its equivalent as directed by e/i. 342 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min, 350 rpm (tolerance as per is: 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required.(dsr e&m 2022 19.1) 343 supply and fixing of 5 blade exhaust fan ventile air dx 225 mm of havellsor equivalent make including all material, t&p etc required for proper completion of work as approved by engineer in charge.(csi no. 28.38) 344 supply and fixing of 3 blade wall fan ofhavells platina 400 mm or equivalent including all material, t&petc required for proper completion of work as approved by engineer in charge.(csi no. 28.37)
  • View Tender
  • Document
  • Bid Support
4 Industrial Development Agencies
image image
corporations/Associations/Others
TRN :49024378 |  10 May, 2025
Tender Value : 7.20 Lacs
 Kanpur - Uttar Pradesh
Tender for tender for 38-construction of mokshdham at gram chakothi block- chakothi - boring of 25cm dia piles of double under reamed of 50cm dia of bulb and 3.60 meter depth in b.c. soil with hand operated auger machine 2 r.c.c . work in cement coarse sand and 20mm gauge stone gride in proportion 1:2:4 in piles grade beam excluding supply of reinforcement and also including supply of all material labour t&p centeringand shuttering etc. 3 r.c.c . work in cement coarse sand and 20mm gauge stone gride in proportion 1:2:4 in columns excluding supply of reinforcement and also including supply of all material labour t&p centeringand shuttering etc. 4 m-150 brickwork in 1:6 cement and fine sand mortor including cost of material , labour, t&p complete 5 m-150 brickwork in 1:6 cement and fine sand mortor including cost of material , labour, t&p complete in super structure 6 r.c.c . work in cement coarse sand and 20mm gauge stone gride in proportion 1:2:4 in lintel t-beam, slab excluding supply of reinforcement and also including supply of all material labour t&p centeringand shuttering etc. lintel 7 m.s. work in r.c.c. incluing supply of steel its wastage and hooks and authorised overlap 8 earth work in filling by cartage of earth from 1.00km by tractor trolly. 9 12mm thick plaster work in 1:4cement and fine sand mortor 10 coarse sandfilling under floor 11 laying of pcc in 1:6:12 cement ,sand and 40mm stone ballast in base concrete 12 laying of 80mm thick rouble moulded interlocking concrete pavment as per drawing and design clause 1501 13 p/applying white cemnent based putty of avg. thickness 1mm of appd. brand over the plastered wall surface to prepare to surface even and smooth 14 finishing wall tex tured exterior paint of required shad : new work ( two or more coat) @3.28ltr /10sqm over and including priming coat of exterior primer applied @2.20kg /10sqm 15 12 mm thick plaster in 1:2 cement and coarse sand mortor over slab 16 site clearence before and after completion the work 17 imformation board + photography 18 installation of hand pump 19 tranpotation of handpump material and t&p from divi. store to site of work 20 hiring charge of necessary t&p and equipment requried for instalation of handpump cutter , wire rope lamps wooden planks ,loading arrengment for palm and presser for com. days including excavation of pit and water etc. complete 21 p/ of india mark hand pump machine and pipe etc 22 standerd deepwell hand pump machine complete 23 140mm pvc pipe 8kg per sqm 24 p/ o 32mm diameter gi pipe b class all completion 25 to make vertical bore 150mm dia boring by hand boring in following depthsin soil mixed with morum /shingle /kankar the depth of bore shall be according to strata condition this shall be decited by eng. i/c 26 0-30m 27 31-50 28 51-60 29 s/f of end cap 110 mm dia required including all material labour t&p 30 s/f of nylon meshrequired including all material labour t&p 31 preparation of assembly as per eng. i/c and lowering of assembly consisting of110mm dia pvc pipe 6kg/sqcm, 1 kg /sqcm, 10 kg /sqcm and testing ets vertically along with stainer pipe fitted at bottom . 32 0-45m 33 45- above bgl 34 s/filling coarse sand arround stainer ( up to 3 mtr. from the bottom of stainer and filling of bentonite between bore hole and casing pipe including all material labour t&p 35 lowring of 32mm dia gi pipe with ets cutting , threding etc. com. 36 development of drilled bore hole sand till free yield of water is achieved in newly constructed bore hole including all material labour t&p etc. com. and installation of india marka ii hndpump (padestal) its position and its centering 37 disaffection by chlorination work of development work of after handpump installation after devlopment including supply of all chemicals required. 38 const. of pcc plateform in 1:2:4 of size 1.85 mtr. dia as deparmental type design for india marka handpumpe 39 const. of pccdrain in 1:2:4as deparmental type design complete 40 embossing on pedestal as per direction of eng.i/c 41 provision for testing of water sample in district water qlty.lab of newly installed handpumpe
  • View Tender
  • Document
  • Bid Support
5 Housing Urban And Rular Development
image image
Local Bodies
TRN :48606691 |  15 May, 2025
Tender Value : 56.65 Crore
 Prayagraj - Uttar Pradesh
Tender for tender for kareli - nurulla road to askari market road block c and block d housing scheme and nurulla road from mahavir chauraha to karamat ki chowki near sasur khedari river and also till the connecting road - clearing grass and removal of rubbish upto a distance of 30 m outside the periphery of the area as per technical specification clause 201. 3 dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including t&p and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 60 metres as per instructions of e-i-c. (by mechanical means). 4 i) cement concrete 5 ii) reinforced cement concrete/ r.b. 6 dismantling of flexible pavements and disposal of dismantled material up to a lead of 100 m, stacking serviceable and unserviceable materials separately as per technical specification clause 202. bituminous / granular courses (by mechanical means) 7 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 8 removing all type of hume pipes and stacking within a lead of 1000 metres including t&p, earthwork and dismantling of masonry works. 9 (i) up to 600 mm dia 10 removal of telephone / electric poles / street light / lamp post including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately 11 disposal of moorum/building rubbish malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of engineer-in-charge. note- item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. 12 dewatering using 10hp to 70hp diesel engine pump set including hire charges, cost of diesel, engine oil, pump operator, labor charges, conveyance of pump set and fuel to site and back, loading, unloading and any other incidental charges etc., complete. (hire charges for diesel pump set for 10 hp) 13 [b] bill no. 2 - earthworks 14 excavation for road work in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and leading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections and transporting to the embankment location within all lifts and lead upto 1000m 15 removal of unserviceable soil including excavation loading and disposal but excluding replacement by suitable soil which shall be paid separately as per clause 305 16 i) lead upto 1000 m 17 ii) lead upto 8000 m 18 earth work in excavation of foundation of structures as per drawing and technical specification, including setting out construction of shoring and bracing, removal of stumps and other deleterious matter dressing of sides and bottom, backfilling the excavation earth to the extent required and utilizing the remaining earth locally for road work. 19 mechanical means (depth upto 1.5 m) 20 i) excavation 21 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 22 [c] bill no. 3 - development of carriageway 23 stabilization of in-situ (existing pavement crust) or soil or otherwise sub base/ base course up to the required depth by cold in-situ recycling using cement and chemical additives / otherwise: providing pulverizing, spreading, milling and mixing of chemical additives at the appropriate rate as per job mix design in accordance with irc-sp-72-2015 , irc-37-2012 & 2018 and irc sp 89 (part ii) 2018. cementitious additive @ rate of minimum 5 - 7% and ccs/cs additive should be spread on the existing pavement using a mobile truck mounted containerized cement/ additive spreader with micro processor controlled weighing and spreading system. the additive spreader shall have variable working width sufficient to cover whole pavement lane. the in-situ stabilization process shall be carried out by a mobile and self propelled stabilizer / reclaimer of working width of 2.4 m and with minimum engine horse power of 440 kw with a variable working depth up to 50 cm. the resultant stabilized mix then would be profiled to the required grade, level and thickness using motor grader and the mix would be compacted using 20 tonne pad foot roller in combination with smooth wheel roller to achieve desired proctor density as per irc 37-2012 & 2018 and complete in all respect and curing with water as required including all materials, labour and machinery etc. the entire in-situ process would be carried out in single pass with milling and pulverising of damaged asphalt pavement / soil/ aggregates / soil-aggregate mixture to the desired depth and with simultaneous addition of additives and water with machine integrated spray bars fited on the wheeled self-propelled and vibratory pad foot roller to achieve the desired proctor density in all respects. the tandem roller be followed by pneumatic tyre roller. the minimum unconfined compressive strength (ucs) of stabilized sub base/ base should be 4.5 to 7 mpa after 7 / 28 days of curing as per irc-sp- 72-2015 , irc-37-2012 & 2018 . also durability aspects (wet-dry cycles) of stabilized sub base should be satisfied as per irc 37-2012 & 2018 and irc sp 89 (part ii) 2018. the gradation mixes and materials should be as per irc 37-2012 & 2018 and irc sp 89 (part ii) 2018. the train of equipments to be used are binder spreader- water tanker- additive truck- recycler- padfoot roller (20 tonne) + single drum compactor- grader- tandom roller- pneumatic tyreroller (20 tonne) 24 sami layerproviding and laying stress absorbing membrane interlayer (sami)/bitumen impregnated geotextile layer after clearing of the road surface geotextile conforming to physical requirements of claues 703-3, laid over a tack coat of paving grade bitumen 80- 100 penetration, laid at the rate of 1.05 kg per sqm over thoroughly cleaned and repaired surface to provide a water resistance membrane and crack retarding layer paving fabric to be free of wrinkling and folding and to be laid before cooling of tack coat, brooming and rolling of surface with pneumatic roller to maximise paving fabric contact with pavement surface. 25 providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 to 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. (tack coat on bituminous surfaces ) 26 providing and laying 40mmthickbitumencarpete(b.c.) with 100-120 tph hot mix plant producing and average output of 75 tonege par hour using crushed aggregates of specified grading premixed with bitumen binder(vg-30) @ 5.40% of mix as per most specification clause. etc all comp of work. 27 providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from aggregat aggregate natural sources, portland pozzolana/ordinary portland/portland slag cement, admixtures in recommended proportions as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads as per direction of the engineer-in-charge; for the following grades of concrete.note: extra cement up to 10% of the minimum specified cement content in design mix shall. be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 28 m.s. (tor steel or plain) in plain work such as rcc or rb work including binding for proper shape and including supply of steel and its wastage bend, hooks and authorized overlapping shall be measured and including cost of binding wire. excluding gst (sor-504). 29 [d] bill no. 4 - pedestrian infrastructure (footpath) 30 sand filling in foundation trenches as per drawing & technical specification and as per direction of engineer-in-charge. (including beneath all paver blocks, cobble areas for levelling purpose, etc.) 31 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. (pcc below all paving area, kerb channel, road edge kerb, table top, property edge beam) 32 construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at omc, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (by mix in place method) 33 i) for grading-i material 34 plain/reinforced cement concrete in open foundation complete as per drawing and technical specifications, pcc grade m30using batching plant transit mixer & manual placing(80 mm thickness) r & manual placingand giving broom finish. (pcc with broom finish thickness 80 mm) 35 providing and laying 75mm thick m-30 grade batch mix cement concrete and applying stamping finish to the top surface of freshly laid plain/ reinforced cement concrete of specified grade in porticos, sidewalks, driveways, pool decks and open yards as per direction of the engineer-in-charge. the process shall include the following:-the concrete shall be placed and screeded to the finished grade, and floated to a uniform surface by using standard finishing techniques. the approved color hardener @ 2.7 kg/sqm shall be applied evenly to the surface of the fresh concrete by the dry shake method by sprinkling in two or more shakes, floated after each shake and trowelled only after the final floating. the approved release agent @ 0.113 kg/sqm shall be applied evenly to the trowelled surface before stamping or the said release agent can be applied to the flexible polyurethane stamp moulds of approved design and in required sizes to achieve final stamped pattern. these stampings shall be placed on the surface of concrete in three to four pieces at a time and tapped gently with rammers of sufficient size & weight to leave proper stamp marks and the process repeated for the remaining concrete surface till the hole surface to be stamped is completed within the time while concrete is in plastic stage of setting.after stamping, the curing shall be done as per manufactures specifications. after initial curing the imprinted joints shall be grouted using cement slurry mixed with color hardener as per theequirement. the surface shall be sealed by applying acrylic based sealer not less than 0.167 litre/sqm.on finished surface.the construction joints shall be provided by groove cutting of size 4mm x 20mm in panel size 3m x 3 m or lesser as per the site conditions and filling the same with 10 mm baker rod and providing and laying (pu) polyurethane based joint sealer of approved make as per manufacturer’s specifications and finished by applying polyurethane resin based top protective clear coat of minimum 80 micron applied with rollers on properly cured and dry clean surface. (cost of concrete for flooring is not included in this item which shall be paid separately.) 36 80 mm thick c.c. paver block of m-35 grade with approved color design and pattern. 37 supply and fixing of tactile indicators made from ss-304 grade stainless steel. warning tactile indicator shall be installed on the walking surface in a raised grid pattern of dots or stud. minimum 36 studs to be placed in 300x300 mm area. dimensions - 35mm outer dia x25mm inner dia, stem dia 8mmx12mm, weight - 28grm.all the indicator will be installed into correctly drilled holes and place any suitable adhesive, all the indicators shall be aligned property, all complete as per direction of engineer-in-charge. 38 supply & fixing of tactile indicators made from ss-304 grade stainless steel. directorial tactile indicator shall be installed on walking surface, consisting of a series of raised bar/strip. min 4 bars/strip to be placed in direction perpendicular to distance of travel in 300x300 mm area. dimensions-280mm l x 35mm w x 4.5mm, stem dia 8mmx12mm, weight - 250grm all the indicator will be installed into correctly drilled holes and place any suitable adhesive, all the indicators shall be aligned property., all complete as per direction of engineer-in-charge. 39 providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to is : 15622 of approved make in all colors and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of engineer-in-charge 40 chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (dsr-11.20) 41 providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of engineer-in-charge. (saucer drain along the road edge, curved kerbs at property entry/exit, curved kerbs at side roads) 42 providing and laying at or near ground level factory made kerb stone of m-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment). (precast c.c. kerb stone shall be approved by engineer-in-charge). 43 cc grade m20 using batching plant transit mixer & manual placing all complete as per direction of e-i-c. 44 [e] bill no. 5 -parking 45 construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at omc, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (by mix in place method) 46 i) for grading-i material 47 supplying and filling in plinth with sand under floors/in trenches, including watering, ramming, consolidating and dressing all complete with material (from source to site), labor and t&p etc. required for proper completion of the work. (including royalty). 48 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days and giving broom finish. (pcc) 49 providing and laying factory made chamfered edge cement concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using pu mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of engineer-in-charge.80 mm thick c.c. paver block of m-35 grade with approved color design and pattern. 50 [f] bill no. 6 -cycle track 51 nil 52 [g] bill no. 7 - traffic signs, markings and other road appurtenances 53 providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow ms tube posts/horizontal members/bracings covered with 1.63mm thick ms sheet. the sheet shall be fixed with 30x5mm ms flat by suitable welding/riveting. the panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. ms channel islc 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long ms angle 40x40x6mm bracing. suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. the work shall be executed as per drawing/direction of engineer-in-charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the engineer-in-charge. the barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. the barricading shall not be removed without prior approval of engineer[1]in-charge.(note :- one time payment shall be made for providing barricading from start of work till completion of work i/c shifting. the barricading provided shall remain to be the property of the contractor on completion of the work). 54 reflective raised pavement markers (cat eye/ road stud) supply and fixing of raised pavement marker with made of plastic body of rpm/ road stud shall be moulded from asa (acrylic styrene acrylonitrile) or hips (high-impact polystyrene) or acrylonitrile butadiene styrene (abs) or any other suitable material approved by the engineer. the marker shall support a load of 13,635 kg tested in accordance with astm d4260. the reflective panels shall consist, of number of lenses containing single or dual prismatic cubes capable of providing total internal reflection of the light entering the lens face. lenses shall be moulded of methyl methacrylate conforming to astm d788 of equivalent. the slop or retro-reflecting surface shall preferably ba 5+/.5 degree lo base and the area of each retro -reflecting surface shall not be less than 13.00 $q.cm. the marker height shall not be less than 10 mm and shall not exceed 20 mm & width shall not exceed 130 mm the base of the marker shall be flat within 1.3 mm all road studs shall be legibly marked with the name trade or other means of identification of the manufacture. epoxy installations, excess adhesive around the edge of the marker, excess adhesive on the pavement and adhesive on the exposed surfaces of the markers shall be immediately removed. the contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel , to the engineer . in addition , a two year warranty for satisfactory infield performance of the finished road marker shall also be given by the contractor who carries out the work of fixing of reflective road markers. in case the markers are, displaced , damaged . get worn out or lose their reflectivity compared to stipulated standards , the contractor would be required to replace all such markers within 15 days of the intimation from the engineer , at his own cost. the rate shall include all materials, labor, t&p, transportation, installation and incidentals all complete as per direction of the engineer-in-charge, 55 rpm with shank 56 solar power road marker the solar studs shall be made of aluminum alloy and polycarbonate material which shall be absolutely weather resistant and strong enough to support to load of 13,635 kg tested in accordance with astm d4280. its color may be white, red, yellow, green or blue or combination as directed by the engineer. its water resistance shall meet the requirements of ip 65 in accordance with is: 12063:1987 category 2 for the protection against water ingress. the dimensions of solar studs shall not be less than 100 mm * 100 mm * 10 mm. it shall have super bright leds so as the provide long visibility from a distance of more than 800 m. its flashing rate shall not be less than 1 hz. its should be able to give the prescribed performance in the temperature range of -40 degree c to +55 degree c. its life shall be not less than 3 years. the rate shall include all material, labor, equipments, fabrication, transportation erection, installation and incidentals all complete as per direction of the engineer-in-charge 57 r.cc work (1:1.5:3) (m-20) with cement course sand &20mm the stone grit including all complete cement concrete with cement sand &20mm gauge stone grit with the proportion of (1:1.5:3)including all complete the work (morth ra-12.8 c, case-ii) 58 m.s. or iron work plain or tor for rcc work including cutting, bending, rivetting or welding etc. where necessary. excluding gst (s.i.no-504) 59 painting two coats on new concrete surfaces - painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces 60 m.s. or iron work of heavy sizes section such as trusses, built up gates, record racks, roof work, gates etc. including rivetting or welding where necessary. excluding gst (s.i.no-503) 61 painting of m.s. grill with enamul paint etc all complete work. (s.i. 15.15 new item no.) 62 providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, t&p, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of engineer-in-charge and accordance with applicable specifications. 63 providing and fixing of retro- reflectorized cautionary, mandatory and informatory sign as per irc :67 made of high intensity grade sheeting type-ivvide clause 801.3, 2mm thick aluminum sheeting, 1.5 mm thick supported on mild steel angle iron post 75mm* 75mm *6mm firmly fixed to the ground by means of properly designed foundation with m15 grade cement concrete 45cm* 45cm*60 cm, 60 cm below ground level as per the approved drawing. the retroreflective sheeting shall be tested for a certificate of having the sheeting coefficient of retro reflection, daytime, color and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoors weathering and its having passed these tests shall be obtained from international/ government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should be also obtained from indian condition within 3 years of launching ofproduct by the manufacturing abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirement from a reputed laboratory in india can be accepted provisionally. in such a situation , the employer/client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of 3 years outdoor weathering of the sheeting as per irc 67:2012 . legends, letters, numerals, and borders etc. should be as per mort&h specification 801.3.7. proof of the same in form of government reports shall be uploaded while quoting tender. 64 90 cm equilateral triangle with diffinitation plate size (20cm x 60 cm) 65 60 cm equilateral triangle with diffinitation plate size (20cm x 60 cm) 66 60 cm circular with diffinitation plate size (20cm x 60 cm) 67 80mm x 60mm rectangularwith diffinitation plate size (20cm x 60 cm) 68 60 mm x 45 mm rectangularwith diffinitationplate size (20cm x 60 cm) 69 60cm x 60cm square with diffinitation plate size (20cm x 60 cm) 70 90 cm high octagon 71 direction and place identification signs up to 0.90 sqm size board providing and erecting direction and place identification retro-reflectorized sign as per irc-67 made of high intensity grade sheeting the retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime color and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from international/government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally. in such a situation, the employer/ client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per irc 67:2012. legends, letters, numerals and borders etc. should be as per mort&h specification no-801.3.7. sheet fixed over aluminum sheeting 2 mm thick with area not exceeding 0.9 sqm. supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with m-15 grade cement concrete 45x45x60cm., below ground level as per approved drawing, complete. 72 direction and place identification signs with size more than 0.90 sqm size boardproviding and erecting direction and place identification retro-reflectorized sign as per irc-67 made of high intensity grade sheeting the retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime color and luminance, shrinkage, flexibility. liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from international/government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally. in such a situation, the employer/client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per irc 67:2012. legends, letters, numerals and borders etc. should be as per mort&h specification no-801.3.7. sheet fixed over aluminum sheeting 2 mm thick with area exceeding 0.9 sqm. supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with m-15 grade cement concrete 45x45x60 cm below ground level as per approved drawing, complete. 73 providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans & as per irc :67 74 brick masonry work in cement mortar 1:4 (1cement: 4 coarse sand) in foundation complete with cement concrete bricks procured from c&d waste recycling plant baswar excluding pointing and plastering, as per drawing and technical specifications. 75 struck pointing with cement mortar consisting of 1 part cement and 2 parts of fine sand of 1.25 finerness modulus.sor 2022 si no574 76 12 mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement :3 sand)and as per direction of engineer in charge. 77 finishing walls with ready mixed premium acrylic emulsion paint (company depot tinted) having volatile organic compound (voc)less than 50 gm/liter and uv resistance as per is 15489:2004, alkali, & fungal resistance, dirt resistance exterior paint of required shade with silicon additive(for painting wall, street furniture) new work (two or more coats applied @1.43 liter/10sqm over and including priming coat of exterior primer applied @ 0.90 liter/10 sqm) 78 supplying and fixing of cast iron antique style bench having weight of sides not less than 72 kg (36 kg each) fitted with fibre rectangle strip (should not be less than 50 mm x 25 mm and 1.6mm thick. length of bench should not be less than 6 ft (end to end of castiron support). 79 [h] bill no. 8 - utility and street light cabling 80 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.(pcc below pipe of storm water, sewer, water, inspection chamber for storm water, telecom chamber, power chamber and sewer) 81 providing and laying non pressure np-3 class (medium duty) r.c.c. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete (storm water, sewer) 82 600 mm dia rcc pipes 83 providing of 7- way 40mm multi ducts with solid permanently solidly lubricated silicone in inner layer for ict fiber cables conforming to astm f 2160, astm d 2444 and /or equivalent indian standard. external sheathshall be in orange colorand shall be free from visual defects like blisters, shrink holes,flaking, scratches, groove lines & surface roughness. the color of the 7 nos. plb hdpe ducts shall be green, blue, yellow, brown, violet, grey , red for differentiation. outer sheet thicknessshall be 1.2mm +/-0.2mm. the inner surface of the multi channel ducts shall be spirally ribbed & shall be of a configuration for faster installation of cables. wall thickness(mm) of each of the ducts excluding rib height shall be 2.9mm +/- 0.3mm. iso requirements- iso 9001, 14001, 18001, complete as per specifications and directions of engineer-in-charge. (7 way multi utility duct for ofc) 84 supply of hdpe pipe of size 110mm for distribution system conformingn to latest/ relevant i.s. 4984/1995 specifications with all jointing materials and specials conforming to latest /relevant i.s. specifications including f.o.r. destination and all taxes and insurance etc. with loading, unloading and carting up to site of work, also including specials for these pipes and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete (including testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches) all complete as per instructions of engineer-in-charge.110mm dia hdpe pipe pn-6 class pe-100 85 supply of hdpe pipe of size 63mm for distribution system conformingn to latest/ relevant i.s. 4984/1995 specifications with all jointing materials and specials conforming to latest /relevant i.s. specifications including f.o.r. destination and all taxes and insurance etc. with loading, unloading and carting up to site of work, also including specials for these pipes and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete (including testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches) all complete as per instructions of engineer-in-charge.63mm dia hdpe pipe pn-6 class pe-100 86 rcc grade m20 using batching plant transit mixer & manual placing ( side wall, bottom slab for all inspection chamber i.e. storm water, telecom, power, sewer, water) 87 supply and installation on site - recessed double seal ofwith a clear opening of750*750 mm di manhole cover and frame(material- ductile iron grade 500/7) of class b125 having minimum load capacity 125 kn load as per en124-2, the top cover( should have 2 no. of keyholes ) as per the design approved by engineer in chargedesign approved by engineer in charge. 88 supply and installation on site - recessed double seal ofwith a clear opening of750*750 mm di manhole cover and frame(material- ductile iron grade 500/7) of class d400 having minimum load capacity 400 kn load as per en124-2, the top cover( should have 2 no. of keyholes ) as per the design approved by engineer in chargedesign approved by engineer in charge. (storm water) 89 supply and fixing gully grates red 048 grh – 300* 750mm d.i. gully grate & frame in d400 load class , as per bs en 124 black bitumen paint, all complete as per direction of engineer-in-charge. 90 constructing rcc rectangular type manholewith a floating coat of neat cement, foundation concrete 1:6:12mix (1 cement : 6 coarse sand : 12 graded brick bats 40 mm nominal size), and making necessary channel in cement concrete of m-25 grade finished with a floating coat of neat cement, all complete as per standard design and instruction of e-i-c. 91 restoration of water pipeline in case of damage 92 [i] bill no. 9 - horticulture / landscaping works 93 trenching in ordinary soil up to required depth including removal and stacking of serviceable materials and then disposing of as directed and spreading earth & neatly levelling, breaking clods etc. and making the trenched area with designed mounds, paths and sitting spaces etc. to proper levels by filling with earth or earth mixed with manure and properly watering complete work in required topography as per drawing & specifications. 94 supplying and stacking of good earth at site including royalty but including carriage1km (earth measusred in stacks will be reduced by 20% for payment). 95 supplying and stacking at site dump manure from approved source,including carriage up to 1 km (manure measured in stacks will be reduced by8% for payment) 96 mixing earth and manure in specified proportion or as directed. 97 rough dressing the trenched ground including breaking the clods. 98 fine dressing the ground 99 spreading ofmixed good earth and manure in specified proportions as above and in required thickness. 100 uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation. 101 providing & laying selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge 102 preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of officer-in-charge. 103 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete. 104 providing and stacking of nauclea cadamba (kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge. 105 providing and stacking of nyctanthes arbor-tristis (hasingar) of ht. 90-105 cm in earthen pots of size 20 cm as per direction of the officer-in-charge. 106 providing and stacking of terminalia arjuna of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. 107 providing and stacking of plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size hdpe bags as per direction of the officer-in-charge. 108 providing and stacking of plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size hdpe bags as per direction of the officer-in-charge. 109 providing and stacking of ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. 110 providing and stacking of ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.. 111 providing and stacking of duranta golden, having ht.15 to 20 cm bushtyshape with fresh and healthy leaves in 15 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge.. 112 providing and stacking of tradescantia zebrina having in 15 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge. 113 providing and stacking of wedelia trilobata,full of leaves in 15 cm size ofpoly bags & as per direction of the officer-in-charge. 114 providing and stacking of asparagus sprengeri of height 30 cm to 45 cm, full of leafy branches in 15 cm size of earthen pot / plastic pot & as per direction of the officer-in-charge.. 115 providing and stacking of ophiopogon jaburan ( variegated ), full of variegated leaves in earthen pot/plastic pot of size 20 cm. as per direction of the officer-in-charge. 116 providing and displaying of croton petra bangalore variety having ht. 60 cm to 75 cm with 4 to 6 branches, well developed, fresh and healthy colorful leaves in 25 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge. 117 providing and fixing ms iron tree guard 60 cm dia and 2 metre high above ground level formed of 4 nos (25 x 6 mm) and 8 nos (25 x 3 mm) vertical ms riveted to 3 nos (25 x 6 mm) iron rings in two halves, bolted together with 8 mm dia and 30 mm long bolts including painting two coats with paint of approved brand over a coat of priming, complete in all respects. 118 street light works (excluding gst) 119 supply & fixing of 9 mtr gi octagonal pole of approved make (top dia 70mm, bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 mtr length) on rcc foundation including the cost of foundation, foundation bolts, excavation & back filling and required t&p complete in all respect 120 supply and fixing of led street light fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 watt. confirming to ip 66 protection complete in all respect. cat: aaa 121 supply and laying of 16 sq.mm. 4 core aluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer-incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 122 supplying and laying 6 swg g.i. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with gi thimble etc. as required. 123 supply and burring of safe earthing electrode t-39 (hot-dip galvanized), length up to 3000mm, outer pipe 76mm inner dia38mm terminal dia 12 mm ,outer gipipe of 16 swg and inner gi pipe of 12 swg withhot dip galvanization up to 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. frame with hinged cover & masonary housing. (from electrode terminal to switch board, cost of 25 x 3 gi. strip will be extra) make: as approved in u.p. p.w.d., & c.p.r.i. certified. 124 making connection of each street light by s/l 1.5 sqmm frlsh copper wire complete as per direction of engineer in charge. 125 supply & fixing of 9 mtr gi octagonal pole of approved make (top dia 70mm, bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with double arm bracket (1 mtr length each ) on rcc foundationincluding the cost of foundation, foundation bolts, excavation & back filling and required t&p completee in all respect. 126 supply & laying of 63 mm dia (od-63 mm & id- 51 mm nominal) dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers, etc. conforming to is 14930, part ii complete with fitting and cutting, jointing, etc. direct in ground (75 cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc, complete as required. 127 supply and fixing for automatic street light cubical control juction box painted with anti-corrosive alkali and acid proof pait consisting of 6 amps mcb (b - curve) complete in all respect 128 supply and fixing of 16 sq.mm plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer-incharge. 129 supply and fixing of 40 amp. capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors, hrc fuses, isolating switch metering instrument & instrument box with cts etc. in case of tpn, complete in all respect. 130 supply and laying of 32 mm x 6 mm g.i. strip from earth electrode directly in the ground as required complete in all respect. 131 supply/ erection of surface mounted decorative pole 4500 mm long having base plate 300x300x12 mm with the bottom dia 139 mm upto 1 mtr long with the thickness of 3.6 mm and the top dia is 76 mm upto 3.5 mtr. log. decorative pole made out of galvanized iron tube with cast aluminium embellishments. the poles are painted with polyturetnane paint. the pole have service window at the bottom on the pole for housing the mcb and terminal strips and as per attached drawings. 132 s/f of single arm decorative bracket 100 mm long made of cast iron/ aluminium embellishments painted with polyturetnane paint. 133 supply of led decorative drop down light made of aluminium housing fitted with polycarbonate diffuser having 500 mm dia with 70 w. 134 supplyandlayingof aluminiumconductorpvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer-incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core 135 supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors, hrc fuses, isolating switch metering instrument & instrument box with cts etc. in case of tpn, complete in all respect. 40 a tpn 136 supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer-incharge. 16 sq. mm 137 supply & laying of 63 mm dia (od-63 mm & id- 51 mm nominal) dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers, etc. conforming to is 14930, part ii complete with fitting and cutting, jointing, etc. direct in ground (75 cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc, complete as required. 138 supply and laying 6 swg g.i. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with gi thimble etc. as required. 139 supply and burring of safe earthing electrode t-39 (hot-dip galvanized), length up to 3000mm, outer pipe 76mm inner dia38mm terminal dia 12 mm ,outer gipipe of 16 swg and inner gi pipe of 12 swg withhot dip galvanization up to 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. frame with hinged cover & masonary housing. (from electrode terminal to switch board, cost of 25 x 3 gi. strip will be extra) make: as approved in u.p. p.w.d., & c.p.r.i. certified. 140 part - b utility shifting (including gst) 141 converstion of lt overhead line by underground lt line 142 lt xlpe insulated cable of size 3.5x400 sqmm. 143 lt xlpe insulated cable of size 3.5x240 sqmm. 144 lt xlpe insulated cable of size 3.5x150 sqmm. 145 lt xlpe insulated cable of size 3.5x70 sqmm. 146 9 mtr long stp 147 hdpe pipe 140mm dia peb0, pn-6 148 hdpe pipe 120 mm dia peb0, pn-6 149 hdpe pipe 75 mm dia p880, pn-6 150 aluminium crimping lugs 400sqmm 151 aluminium crimping lugs 240sqmm 152 aluminium crimping lugs 150sqmm 153 aluminium crimping lugs 70sqmm 154 6 swg g.l. wire for earthing along cables. 155 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x400 sqmm. lt cable 156 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x240 sqmm. lt cable 157 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x150 sqmm. lt cable 158 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x70 sqmm. lt cable 159 main lt panel at sub station- 400 kva (type a-2)lncomer- 1 set of 800 amp. tp mccb with spreader & extended handlemetering on lncomer - 1 set of digital ammeter with ass- 1 set of digatal voltmeter with vss- 1 set of led type phase lndicating light (22.5 mm.)with control mcbsoutgoing- 6 set of 250 amp. tp mccb with spreader & extended handte( 5 nos. + 1 no. for capacitor panel)- 2 set of 100 amp. tp mccb with spreader & extended handle 160 main lt panel at sub statton- 250 kva (type a-2) lncomer- 1 no. 630 amp. tp mdo acb with inbuilt mpr release with i ontoff tnai.ating lightmetering on lncomer - 1 set of digital ammeter with ass- i set oldigital volt-meler wirh vss- 1 set of led type phase indicating light (22.5 mm.j with control mcbs outgoing - 5 set of 250 amp. tp mccb with spreader & exrended handle- 2 set of 100 amp. tp mccb with spreader & extended handle flnstallation oflt distribution boards for lt underground system (type a,b&cj) 161 supply , installation, testing & commissioning of outdoor type feeder pillar panetto be made of 2 mm crca sheet and covers will be j.6mm crca sheet dulypowder coated paint with 300 amps al. busbar. (type-b2)lncomer - 250 amp. tp mccb - 1 no.outgoing - 63 amp. tp mccb - 5 nos.lnstallation of lt distribution boards forlt underground system (type-a, b & c) 162 outdoor type feeder pillar panel to be made of 2 mm crca sheet and covers will be 1.6mm crca sheet duly powder coated paint with 300 amps al. busbar. [type-b3] incomer - 100 amp. tp mccb - 1 no. outgoing - 63 amp. tp mccb - 4 nos.lnstallation of lt distribution boards for lt qnderground system [tvpe-a, b & cl 163 lockable distribution boxes of size 450x400mm with bus bar 100 amp. tpn to feed upto 10 houses (type c) 164 xlpe lt service armoured cable for single phase,2x6 sq. mm.(pvc armoured consumer service cablel 165 xlpe lt service armoured cable for single phase,2x10 sq. mm.(pvc armoured consumer service cablej 166 xlpe lt service armoured cable for three phase,4x10 sq. mm.[pvc armoured consumer service cablel 167 xlpe lt service armoured cable for three phase,4x1.6 sq. mm.(pvc armoured consumer service cablel 168 xlpe lt service armoured cable for three phase,4x25 sq. mm.(pvc armou[ed consumer service cable) 169 pvc pipe 32 mm dia 170 pvc pipe 50 mm dia 171 electronic kwh meter 1px2w with box. for single phase consumer 172 electronic kwh meter 3px4w static meter with box.for three phase consumer 173 carriage , laying of 3.5cx400 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 140 mm dia. 174 carriage, laying of 3.5cx150/240 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 1.20 mm dia. 175 carriage ,laying of 3.5cx70 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 75mm dia. 176 painting of stp incuding paints [2 ltr red oxide and 2 ltr alluminum paint for each pole.l 177 grouting of st pole 178 cartage , erection and dismentling charges 22% of materials cost 179 conversion of 11kv overhead/underground line by 11kv line underground 180 11 kv cable size 3x185 sq.mm xlpe 181 stp 11m-is 410 sp-55 182 g.l pipe 4 dia 183 top channel 100x50x2240 mm 184 hdpe pipe 160 mm dia pe 80, pn-6 185 service clamp o/s 186 clamp for fixing pipe to pole 187 11 kv cable jointing kit size 3x185 sq.mm xlpe o/d 188 11 kv cable jointing kit size 3x185 sq.mm xlpe s/t 189 earthing complete. 190 m.s. nut & bolt with washer 191 bracing angle 65x65x6x2700 mm with clamp 192 stone pad 193 number plates with clamp 194 danger board & clamp with bolts & nuts 195 stay complete 196 g i barbed wire 197 carriage , layrng of 3x185 sq.mm size 11 kv xlpe insulated cable underground in hdpe pipe dia 160 mm. 198 painting of stp incuding paints (2 itr red oxide and z lt. allrn inrm pal,1t for each pole.) 199 grouting of st pole 200 grouting of stay set 201 cartage , erection and dismentling charges 22% of materials cost 202 conversion of 33kv overhead/ underground line by 33kv line underground 203 cable al. 3x300 sq.mm. xlpe 33 kv 204 stp 11m-is 410 sp-55 205 g.l pipe 6 dia 206 m.s.top channel 100x50x2240 mm 207 hdpe pipe 200 mm dia pe 80, pn-6 208 service clamp o/s 209 clamp for fixing pipe to pole 210 bracing angle 65x65x6x4300 mm with clamp 211 33 kv cable jointing kit 3x300 se mm outdoor 212 33 kv cable jointing kit 3x300 se mm straight through 213 earthing of pole by ms earthing rod of 2ox25o0 mm & 6 swg earthr.ng wire etc. 214 m.s. nut & bolt with washer 215 number plates with clamp 216 danger board & clamp with bolts & nuts 217 stay complete (stay rod 15x1800mm, stay wire 5 kg,, stay clamp, boult & nut rvith grouting 218 daner bqard barbed wire includin jumpering 219 carriage , layrng of 3x300 sq.mm size 33 kv xlpe insulated cable underground in hdpe pipe dia 200 mm. 220 painting of stp incuding paints (2 itr red oxide and z lt. allrn inrm pal,1t for each pole.) 221 grouting of st pole 222 grouting of stay set 223 cartage , erection and dismentling charges 22% of materials cost 224 installation of 250 kva transformer on dp for the shifting of 3 no. 250 kva. 9 no.400 kva & 3 no. 630 kva transformer 225 stp 11m-is 410 sp-55 226 ms channel 100x50x2240 mm 227 service clamp for round pole 228 m.s. bolt and nuts off size with washer 229 l.t. cable 3.5ox4oo so m 230 ltxlpe insulated,unarmoured aluminium singlc corc cable,1x240sq. mm.sizc 231 lt xlpe insulatcd,unarmoured aluminium singlc core cablc,1x400 sq. mm.size 232 earthing of 250 kva t/f with g.i. pip[ 233 earthing rod complet. 234 1 1 kv d.o. fi]se sets 235 1 1 kv tpmo 236 d.d. wire 70 qs mm 237 250 kva t/f 238 l.t. cubical b0x complete 239 l,t. cable 3.50x240 sq mm 240 stay set complete, 241 aluminimum lug 70 sqmm 242 aluminimum lug 240 sqmm 243 aluminimum lug 400 sqmm 244 pvc tape 245 t/f bushing connector of copper strip 246 labour , cartage & errection charges and dismentaling of existing t/f 247 dismentling and cartage from site to store charges 7% (other misclenous charges)
  • View Tender
  • Document
  • Bid Support
6 Security Services
image image
Central Government/Public Sector
TRN :48475497 |  17 May, 2025
Tender Value : 37.70 Crore
 Jaipur - Rajasthan
Tender for tender for provision of klp (ph-ii of two phases) for engr regt at jaipur mil stn; 1 lump sum price worked out by the contractor for building worksas listed in schedule ‘a’ part-i representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 2 lump sum price worked out by the contractor for internal water supply as listed in schedule ‘a’ part-ii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 3 lump sum price worked out by the contractor for internal electrificationas listed in schedule ‘a’ part-iii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 4 lump sum price worked out by the contractor for road, path and culvertas listed in schedule ‘a’ part-iv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 5 lump sum price worked out by the contractor for sewage disposalas listed in schedule ‘a’ part-v representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 6 lump sum price worked out by the contractor for area drainage as listed in schedule ‘a’ part-vi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 7 lump sum price worked out by the contractor for rain water harwestingas listed in schedule ‘a’ part-vii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 8 lump sum price worked out by the contractor for external water supplyas listed in schedule ‘a’ part-viii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the mes 9 lump sum price worked out by the contractor for external electrificationas listed in schedule ‘a’ part-ix representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the mes 10 lump sum price worked out by the contractor for parade ground of size 137 m x 91 m, footbal/hockey 02 nos, basketball courts 02 nos, volley ball courts 02 nos, hardstanding & badminton court 01 noas listed in schedule ‘a’ part-x representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the mes 11 lump sum price worked out by the contractor for compound wall, chain link fencing and gate as listed in schedule ‘a’ part-xi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 12 lump sum price worked out by the contractor for hot water supplyas listed in schedule ‘a’ part-xii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 13 lump sum price worked out by the contractor for refrigeration and cold water supplyas listed in schedule ‘a’ part-xiii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 14 lump sum price worked out by the contractor for site clearance, site developmentand earth workas listed in schedule ‘a’ part-xiv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 15 lump sum price worked out by the contractor for addn/altn of existing buildings & structures (b/r)as listed in schedule ‘a’ part-xv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 16 lump sum price worked out by the contractor for addn/altn of existing buildings & structures (e/m)as listed in schedule ‘a’ part-xvi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 17 lump sum price worked out by the contractor for demolition of buildings & shedsas listed in schedule ‘a’ part-xvii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 18 sch a part-xviii misc items (to be quoted by contractor) notes:(i) this schedule is not pre-priced by mes and the pre-priced rate indicated as rs 0.00 under column 5 signifies this fact only. (ii) excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under sch a part-xiv (site clearance, site developmentand earth work schedule). 19 pop ealse ceiling for sch a part i building work (officers mess & adm block)m&lforpop false ceilingof approveddesignconsisting of 10mm thick plaster of paris ceiling (gyspsum anhydrous) board including gi frame work for 12mm seamless ceiling comprising of gi perimeter channel of 0.55 mm thick with two unequal flange of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre intermediate channel 0.5 mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900 mm centre to centre with gi cleat and tee, expansion fasteners with and including ceiling section (not exc 1.2m length)of 0.55mm thickness having curved web of 50mm and flange of 26mm each with clips of 10.5mm fixed to intermediate channel with connectingclips across the intermediate channel of 457 mm centre to centre complete. 20 internal water supply (sch a part-ii) s & f 15mm bore angle valve/cock cast copper alloy fancy type screwed down high pressure with cructh or butterfly handle screwed both ends for iron pipe or brass ferrule fixed. make - cera-f1012201, jaquar - ari- chr-39053, kohler - k-80154in-4-cp 21 s & f wall mixer/diverter with diverter plate of bathroom 3 in 1 system with provision for both hand & over head shower with 115mm long bend pipe ( for mixer) connecting legs & wall flangs complete all as specified. make: cera-f1022403, jaquar-flr-chr-5281n, hindware-flora f280022 22 s & f chromium plated brass bath tub spout with wall flange(fancy type) suitable for 15mm bore pipe complete all as specified and directed. make- cera-f1012661, jaquar-spj-chr-429, hindware-f-520009 23 internal electrification (sch a part-iii)supply and fixing sp 63 amp rating, 240v, 10 ka c curve miniature circuit breaker (mcb) of following poles and current carrying capacity in the mcb db complete with connection testing and commissioning complete all as specified and as directed. 24 supply and fix tv coaxial,1 module socket complete all as specified and as directed. 25 s&f telephone socket(jack type) ,1 module rj11 with shutter complete all as specified and as directed. 26 m&l for electrolyte grade solid annealed copper conductor,jelly field,aluminium foiled and aluminium wire braided, rg59 (foam). cat part no. whojttkarg59make- havells or equivalent in as mentioned in appx b of particular specification 27 m&l for pvc insulated telephone cables for indoor applications confirming to technical specification g/wir06/02 cat part no.whttatea1p40 make-havells or equivalent in as mentioned in appx b of particular specification 28 s & f for highly efficient led bulbs, 9 watt complete all as specified and directed. make bajaj/havells/hpl 29 s & f blanking plate complete all as specified and directed. 30 s & f of sheet metal enclosure distribution board vtpn ,4 way, 415 volt, double door powder coated, protection class ip-54, isolated neutral bar, mechanical impact strength ik 09 suitable for mounting mcb & mccb dbs confirming to is-13032, is-8632,bs5484 with min 200 amp raiting copper bus bar and grouting, fixing on wall with nut boldts washers proper with pcc works complete all as specified and directed 31 rain water harwesting(sch a part-vii)borewell for rain water harvesting all as specified and shown on drg : (a) provision of trail bore by drilling with reverse rotary system550mm bore upto 52 m depth incl all works pertaining to boring complete in all respect in aluvium soil/ strata incl hard stone / boulder etc.(b)m&l for 150mm bore cpvc pipe assembly jointing, lowering in any position upto the reqd depth below given level incl jointing the pipe by solvent & screwing 04 nos screws in each joint complete all as directed.(c) ditto as item (b) above but slotted pipe(d) m& l for packing with pea gravel of 4.6 mm to 8mm size of approved quality as ordered to pack arround the casing / slooted pipe in borewell all as directed.(e) m&l 25 mm bore perforated cpvc pipe 52 mtr long for vent pipe 32 external water supply(sch a part-viii). m& l for cutting of existing pipeline of 100/150/80 mm dia for taking branch connection alongwith insertion of di tee and connecting material such as joint, nut bolts, etc all as required at site. 33 m&l for construction ofbrick stone masonary valve pit / chamber of size 900 mm x 600 mm x 1000 mm (internal dimensions) all as shown in drawing no td-573, including necessary excavation and earth work, pcc, plaster in cm 1:6 on inside and outside (above ground), ms angle iron 40 x 40x6.0 mm thick complete all as specified and directed and shown on drawings. 34 all as per item no 33.00 but chamber size 450 mm x 450 mm x 600 mm (internal dimensions) complete all as specified and directed 35 supply and fix stop valves 63mm dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed 36 external electrification . (sch a part-ix)supply and fixing led street light fitting 36 wattefficacy greater than 100 lumen/watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 65/66 protection complete all as specified and directed. make : phillips, cat no brp046 led 36 cw mr s1 psu gr 9405 or equivalent in as mentioned in appx b of particular specification 37 supply and fixing poly carbonatejunction box , weather and vermin proof of size 250x250x160 including provn of 4 nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators,including one no. mcb sp 6 amps for light control,drilling of holes.provn of suitable size of gi nuts, bolts, double washer and fi clamps ofsuitable sizefor taking connections and fixing on lt steel tubular poles complete with locking arrangement complete all as specified and directed. 38 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-(main ltp no-01 ) 39 incoming :-(a) mccb 4 pole 320 amp thermal magnetic protection type, 36kamake : legrand, cat no - 4220-06, dpx3 630- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc.(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100outgoing :-(a) mccb 3 pole 160amps thermal magnetic protection type, 36 ka, make : legrand, cat no - 4200-87, dpx 160- 01 nob) mccb 3 pole 200amps thermal magnetic protection type, 36 ka, make : legrand, cat no - 4202-08, dpx 250- 01 no (c) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(d) analog time switch, make- legrand, cat no 4127-80 for sl control 40 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -4. 41 incoming:- (a) mccb 4 pole 160 amps thermal magnetic protection type, 25 ka, make : legrand, cat no - 4200-57, dpx 160- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going:- (a) mccb 3 pole 63 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-43 - 02 no (single offr accn + ltp - 08)(b) mccb 3 pole 40 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-42 - 02 no ( servant qtr + sl)(c) mccb 3 pole 125 a thermal magnetic protection type, 25 ka dpx3 160, legrand, cat no 4200-06 - 01 (offr mess)(d) mcb dp 16amp - 01 no ( garage)(e) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(f) analog time switch, make- legrand, cat no 4127-80 for sl control 42 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp - 8incoming(a) mccb 4 pole 63 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-13 - 01 no 43 (b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 10 no 44 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -3. 45 incoming(a) mccb 4 pole 200 amps thermal magnetic protection type, 25 ka, make : legrand, cat no - 4202-18, dpx 250- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mccb 3 pole 100 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-45 - 01 no(ltp - 06)(b) mccb 3 pole 160 a thermal magnetic protection type, 25 ka dpx3 160, legrand, cat no 4200-47 - 01 (adm bldg)(c) mccb 3 pole 40 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-02 - 02 no (saa stores + old guard house)(d) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 03 no(e) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider (f) analog time switch, make- legrand, cat no 4127-80 for sl control 46 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -6 47 incoming(a) mccb 4 pole 100 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-55 - 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out goingm(a) mccb 3 pole 63 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-43 - 01 no (b) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 05 no 48 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -7 49 incoming(a) mccb 4 pole 63 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-53 - 01 no (b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mccb 3 pole 40 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-02 - 02 no ( bch + mt office)(b) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 13 no (garage) (c) mcb 3 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-55 - 02 no (car washing + longe wala gate) 50 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:- (main ltp no-02 ) 51 incoming (a) mccb 4 pole 400 amp thermal magnetic protection type, 36kamake : legrand, cat no - 4220-07, dpx3 630- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100outgoing (a) mccb 3 pole 200amps thermal magnetic protection type, 36 ka, make : legrand, cat no - 4202-08, dpx 250- 01 no(ltp -02)(b) mccb 3 pole 160amps thermal magnetic protection type, 36 ka, make : legrand, cat no - 4200-87, dpx 160- 01 no (ltp - 01)(c) mccb 3 pole 40 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-42 - 01 no(ltp - 5)(d) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(e) analog time switch, make- legrand, cat no 4127-80 for sl control 52 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -1 53 incoming(a) mccb 4 pole 160amps thermal magnetic protection type, 25 ka, make : legrand, cat no - 4200-57, dpx3 160- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mccb 3 pole 40 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-42 - 01 no ( ltp -5)(b) mccb 3 pole 25 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-01 - 02 no ( fwc + ori )(c) mccb 3 pole 16 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-00 - 02 no ( religious hall + unit shop)(d) mccb 3 pole 80 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-44 - 01 no ( trademen shop)(e) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider (f) analog time switch, make- legrand, cat no 4127-80 for sl control 54 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -5incoming(a) mccb 4 pole 40 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-12 - 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100 55 out going(a) mccb 3 pole 16 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-00 - 01 no ( drying & ironing)(b) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 4 no (car shed - 01 no + scooter shed - 01 no + dhobi ghat - 02 nos) (c) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(d) analog time switch, make- legrand, cat no 4127-80 for sl control 56 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system 57 and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -2incoming(a) mccb 4 pole 200amps thermal magnetic protection type, 25 ka, make : legrand, cat no - 4202-18, dpx3 250- 01 no (b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mccb 3 pole 25 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-41 - 02 no (s/l jco)(b) mccb 3 pole 16 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-00 - 04 no ( s/l 01 jco + engr store + def store + old bldg)(c) mccb 3 pole 80 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-44 - 01 no ( jcos mess)(d) mccb 3 pole 63 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-43 - 01 no (mi room)(e) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 4 nos (car shed - 01 no + scooter shed - 01 no + garage for amb - 01 no +car shed/scooter shed - 01 no ) (f) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(g) analog time switch, make- legrand, cat no 4127-80 for sl control 58 taking down old cable xlpe insulated ,screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor off sizes from existing site 59 dismentling street light bracket off sizes complete all as specified and directed 60 dismantling and taking down lt feeder pillar box off size complete all as specified and directed 61 dismantling and taking down outdoor distribution box off size complete all as specified and directed 62 dismantling and taking down transformers 160 kva to 500 kva and deposit to mes store yard or keeping in safe custody for re-installation complete all as specified and directed 63 parade ground of size 137 m x 91 m, footbal/hockey 02 nos, basketball courts 02 nos, volley ball courts 02 nos, hardstanding & badminton court 01 no (sch a part-x (synthetic floor / mat for basket ball & volley ball courts) m & l for antifungal, anti microbial and u/v resistant comprising of pvc wear resisting coat thickness of 3.5mm to 8mm over of fiber-glass reinforced layer with pvc foaming buffer layer of thickness 4.5mm for good performance in rebounding & absorbing shock complete all as specified and directed 64 refrigeration and cold water supply(sch a part -xiii)supply and fix refrigerator, electric driven (single phase),direct cool single door 5 star refrigeratorwith base drawer with smart inverter compressorcapacitynot less than 185 litrescomplete all as specified and directed 65 supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of ± 2.5% and of capacity not less than 2.0kva complete all as specified and directed 66 supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 cum per hour (or nearest size) steel body complete all as specified and directed 67 addn/altn of existing buildings & structures (b/r) : schedule a part -xvm & l for providing 5-7mm thick screed bed ofchemical adhresive of approved make for laying floor finishes i,e floor tile etc. complete all as specified and directed. 68 taking down existing water proofing roof treatment of any description cleaning the surface by hacking to received plaster complete all as specified and removing demolised material outside mod land. 69 s & f fibre reinforced uv resistant elastomeric liquid applied waterproofing & heat reflective coating with acrylic polymers and polyester/glass fibres after scraping and properly cleaning the surface to remove loose perticles with wire brushes complete or as directed water proofing treatment shall be in three coats over a coat of primer and as per manufacturers instructions complete all as specified and directed. 70 m & l for retrieving vegetation growth/plants from wall roofs, chajja upto double storey height incl taking out deep roots and pouring hcl acid and making good the distrubance surfaces with cm 1:4 incl all means required at site complete all as specified and directed 71 addn/altn of existing buildings & structures (e/m) : schedule a part -xvitaking down of existing unsv sub main wiring any size incl pvc/steel conduit complete and making good to disturbed surfaces complete all as specified and directed. 72 taking down of existing unsv dbs any size complete all as specified and directed 73 supply & fixing of mcbs, 10 ka rupturing capacity, is-8828 marked,dp 10 ampsand fixing in dbs complete all as specified and directed(note:- dbs shall be measured and paid separately in respective item) 74 all as per items no 63.00 butdp 20 amps 75 all as per items no no 63.00 but 4p 25 amps 76 all as per items no no 63.00 but sp 6 amps 77 all as per items no no 63.00 but sp 10 amps 78 all as per items no no 63.00 but sp 20 amps 79 demolition of buildings & sheds : schedule a part -xvii taking down carefully by carefully unscrewing serviceable/unserviceable dbs,any sizes 415 volt complete with bus bar and rails for easy mounting of mcbs complete with from boards and disconnecting from incoming and outgoing complete all as specified and directed 80 taking down sub main wiring of any sizes complete all as specified and directed 81 arbouriculture work laying of lawns including ploughing leveling breaking of clods manuring & removal of stones etc. (cost of manure or extra good earth to be paid separately) maintenance of lawns for 30 days more till the grass forms a thick lawns free from weeds & fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost. in rows 5 cms. apart in either direction 82 supply of different flower plants 900mm to 1500mm at site including loading / unloading & transportation etc.complete all as specified and directed 83 supply of different varieties of shrubs 600mm to 900mm at site including loading / unloading & transportation etc.complete all as specified and directed 84 supply of different varieties of climbers 900mm to 1500mm at site including loading / unloading & transportation etc.complete all as specified and directed 85 supply of different varieties of palms in polyethylene bags / earthen pots according to height growth & age of the plant at site including loading / unloading & transportation etc .complete all as specified and directed 86 supply & planting of shady plants (neem, peepal, goolar, jamun, imli or other specified) along including the following activities :-(a)preparation of soil including & removing of unwanted shrubs removal of stones & garbage.(b) supply of plant at site of two years of age & height more than 1.50mtr.(c)supply of dry manure (farm yard manure.(d)supply of insecticides.(e)digging of pits size 60x60x60 cms. 87 supply & planting of ornamental plants (kachnar, amaltas, gulmohar, arjun, jacranda etc. or other specified) along including the following activities :-(a)preparation of soil including cleaning & removing of unwanted shrubs removal of stones & garbage.(b)supply of plant at site oftwo years of age & height more than 1.50mtr.(c)supply of dry manure (farm yard manure organic).(d)supply of insecticides.(e)digging of pits size 60x60x60 cms. including removal of stones, manu-ring application of insecticides & watering at least15 liter per plant after planting.(f)watering to plants.
  • View Tender
  • Document
  • Bid Support
  • 1
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : till drill
  • Drilling Jar Tenders ,
  • Oil Drilling Equipment Tenders ,
  • Solid Carbide Endmills Tenders ,
  • Hydraulic Hammer Tenders ,
  • Rig Machine Scrap Tenders ,
  • Deep Hole Drill Tenders ,
  • Coring Device Tenders ,
  • Pneumatic Breaker Tenders ,
  • Drill Collar Spares Tenders ,
  • Air Drill Tenders

Get till drill Tender Alert...

936307

Related Searched Keywords : till drill

  • Water Proofing Treatment Tenders From Maharashtra
  • Sculpture Work Tenders From Delhi
  • Underground Sewer Tenders From West-Bengal
  • Rcc Dam Tenders From -Tamil-Nadu
  • Dismantling Tenders From Andhra-Pradesh
  • Ground Levelling Tenders From Gujarat
  • Bore Well Tenders From Karnataka
  • Tubewell Tenders From Uttar-Pradesh
  • Site Leveling Tenders From Rajasthan
  • Piling Work Tenders From Madhya-Pradesh

Read More


Tender Document

772579

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Bore Well Tenders
  • Infrastructural Works Tenders
  • Interlock Paver Tenders
  • Railway Under Bridge Tenders
  • Furbishing Work Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App