Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Terminal Building
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of terminal-building Tenders

List of latest terminal-building Tenders in Indian Tenders. Click on any terminal-building Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for terminal-building Tenders.

Advance Search
  • All-Tenders (11)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
1 Defence
image image
Statutory Bodies and Commissions/Committees
TRN :49019704 |  12 May, 2025
Tender Value : 0
 Karu - Ladakh
Tender for tender for supply and construction of ug tac hq (qty-03 nos) under job no 6151/2025-26 (s&c) (cow); 1 ug tac hq nos 1 2 soakage/septic tank cover nos 6 3 iron foot scraper nos 2 4 lightening conductor nos 1 5 earthing building nos 1 6 fire extinguisher 1 kg ball type nos 8 7 fire extinguisher 2 kg nos 8 8 smoke alarm nos 10 9 35 kva dg set nos 1 10 water storage tk 500 ltr sintex nos 4 11 elect items set 1 annx i 12 ppr items set 1 annx ii 13 sanitary items set 1 annx iii 1 supply and fix led tube light fitting1x 20 watt, complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size(more than 05 yrs warranty). nos 6 2 supply and fix led invertor rechargeable tube light fitting1x 20 watt , complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.(more than 05 yrs warranty). nos 5 3 supply and fix led luminaire 600mm x 600mm of 30 watt ,220 volt ac surface type with high efficiency soft glare light complete with driver holder & led lamp suitable for roof surface / ceiling incl including connecting up with twin core twisted flexible copper conductor cable with suitable size complete.(more than 05 yrs warranty). nos 8 4 supply and fix led mirror light fitting1 x 10 watt , complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size(more than 05 yrs warranty). nos 5 5 supply and fix bulk head 1x10w, 230 volt incl led light driver holder connecting up with twin core twisted flexible copper conductor cable with suitable size complete. (more than 05 yrs warranty). nos 3 6 supply and fix pvc lamp holder with isi mark. nos 5 7 supply and fix led invertor type rechargeable bulb 10 watt with isi mark.(more than 05 yrs warranty). nos 5 8 supply and fix switch socket combination 5 pin, 15 amp with isi mark. nos 8 9 supply and fix switch socket combination 5 pin, 5 amp with isi mark. nos 14 10 supply and fix ceiling rose three terminals (five layered) pvc poly carbonate, isolated body. nos 32 11 m&l for point wiring complete for one light point/ exhaust fan point/ bell point controlled by one switch with using 1.5 sqmm 1100 volt including 1.5 sqmm frls pvc insulated, unsheathed, multi standard copper conductor cable as continues earth wire connected to metallic bodies of luminaries/ fan etc at one end and to common earth dolly at other end, complete wiring drawn through pvc concealed of suitable size (as per conductor run) medium grade, isi mark including all accessories and fitting / junction box/ inspection covers/flexible conduit/ metal flush box of suitable size for fixing any types of switches/ socket etc point 37 12 all as above item no 11 here in before but point wiring for one socket point 6 amps on indepent board complete all as specified. point 10 13 all as above item no 11 here in before but point wiring for one socket point 6 amps on same board complete all as specified. point 4 14 all as per ser items no 11 here in before but with 2.5 sqmm frls copper wire with 1.5 sqmm frls copper earth wire for independent 15 amp points. point 8 15 sub main wiring 2x4 sqmm frls pvc insulated, unsheathed, multi standard copper conductor single core with earth wire complete. rm 40 16 supply and fix double door mcb distribution box spn 8 way complete conforming to ip65. nos 2 17 supply and fix mcb spn 32 amp,230v 50hz 10ka, b series. nos 2 18 supply and fix mcb sp 16 amp 240v 50hz b series. nos 2 19 supply and fix mcb sp 20 amp 240v 50hz b series. nos 3 20 supply and fix mcb sp 32 amp 240v 50hz b series. nos 4 21 supply and fix mcb sp 3 amp 240v 50hz b series. nos 3 22 supply and fix pvc body exhaust fan 200 mm sweep with louvers shutter, 230 volt ,50 hz, rpm 1200, copper winding and suitable size of hole for fixing of fan complete. nos 5 23 supply and fix switch piano type 5 amps isi marked. nos 37 1 pp-r pipe (pn 20/sdr-6) 3 layer with outer dia40mm with isi mark. rm 30 2 pp-r pipe (pn 20/sdr-6) 3 layer with outer dia 32mm rm 50 3 pp-r tank connector outer dia 32mm. nos 2 4 pp-r gate valve connector outer dia 40mm nos 2 5 pp-r elbow 90 degree plane outer dia 40mm nos 12 6 pp-r elbow 45degree plane outer dia 40mm nos 12 7 pp-r elbow 90 degree plane outer dia 32mm nos 12 8 pp-r elbow 45 degree plane outer dia 32mm nos 12 9 pp-r tee reducer 40-32mm nos 12 10 pp-r union outer dia 32mm nos 5 11 pp-r wall clamp dia 40mm nos 16 12 pp-r wall clamp dia 32mm nos 25 13 pp-r socket outer dia 32mm nos 10 14 pp-r socket outer dia 40mm nos 8 15 pp-r plug dia 25mm nos 5 16 pp-r plug dia 15mm nos 5 17 pp-r socket, elbow & tee each of dia 25mm set 25 18 pp-r socket, elbow & tee each of dia 20mm set 25 19 nitrile insulation min 50mm thick for pp-r pipe rm 80 20 adhesive solution sr-998 for jointing of insulation .make fevicol ltrs 5 21 1mm thick and 1 mtr wide aluminium sheet to cover nitrile insulation. minimum 50mm should be overlap and fixed with suitable length self taping screw distance of screw not more than 150mm c/c and ss band 13mm wide x 0.40mm thick with ms ring should be provided wherever required at suitable interval. rm 30 22 pp-r tee outer dia 32mm nos 5 23 pp-r female threaded elbow outer dia 32mm x 15 mm nos 25 24 pp-r male threaded elbow outer dia 32mm x 15 mm nos 5 25 pp-r female threaded socket outer dia 32mm x 15mm nos 10 26 pp-r female threaded socket dia 25mm nos 10 27 pp-r wall clamp dia 75mm nos 10 1 vitreous china ceramic ewc p &s (white colour) with 10 ltrs capacity pvc flushing cistern with seat cover (pvc) complete with entire accessories as per good engineering practice. nos 5 2 corner shelf of toughned glass with chromium plated steel frame. nos 5 3 cp towel rail 600mm long 20mm dia. nos 5 4 ceramic wash basin (630 x 450mm) (white colour) accessories to include waste pipe, coupling etc. nos 5 5 urinal pot vetreous china bowl urinal pot flat back model 5004 confirming to is 771 (part 3) sec 2 nos 5 6 chromium plated (cp) brass pillar cock. nos 5 7 chromium plated (cp) soap dish isi mark. nos 5 8 chromium plated (cp) bib cock mixture (long body). nos 5 9 chromium plated (cp) brass bib cock (short body) with isi mark. nos 5 10 chromium plated (cp) brass bib cock (long body) isi mark nos 5 11 chromium plated (cp) brass stop cock. nos 15 12 pvc insulated connection 16mm dia 450mm long nos 15 13 decorative looking mirror bath cabinet (600mm x 450mm) with suitable pvc frame nos 5 14 wash hand basin shelf of ss with chromium plated (cp) steel frame. nos 5 15 chromium plated (cp) steel coat hook with two prongs. nos 10 16 dcwpe pipe 75mm dia rm 35 (i) socket nos 10 (ii) tee nos 10 (iii) elbow nos 10 17 dcwpe 110mm dia rm 30 (i) socket nos 10 (ii) tee nos 5 (iii) elbow nos 5 18 stainless steel jali with hole for waste pipe. nos 10 19 stainless steel jali without hole. nos 5 20 pvc nahani trap 75mm dia. nos 10 21 pvc vent pipe 2 mtr length ,75mm dia with cowl 75mm dia. nos 2 22 health foucet with 1.2 mtr long nos 5
  • View Tender
  • Document
  • Bid Support
2 Construction
image image
State Government
TRN :49022392 |  13 May, 2025
Tender Value : 31.44 Lacs
 Gangapur - Maharashtra
Tender for providing electrical installation in, premises street light, water pump and fire extinguisher for the newly constructed zilla parishad primary health center (p .h .c)main building (g.f+f.f) [under scheme d.p.c. (general) year 2022-23, 34512595 construction expantion & m/ce & repairs of p.h.c/ phsc) at village,lasur stationtq. gangapurdist. chhatrapati sambhajinagar.= 1 supplying and erecting 25 mm dia. corrugated flexiblepolypropyleneconduit 2 supplying anderectingpvctrunking (pvccasing-n-capping)ofsize25 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 3 supplying anderectingpvctrunking (pvc casing-n-capping)ofsize20 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 4 supplying anderectingpvctrunking (pvccasing-n-capping)ofsize32 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 5 supplying anderectingpvctrunking (pvccasing-n-capping)ofsize40 mm with accessorieson wall/ceiling as per specification no: wg-ma/con. 6 supplying and erecting mains with 2x1.5 sq.mm frlshcopperpvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg-ma/bw 7 supplying and erecting green earth wire 1x1.5 sq.mm frlshcopperpvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg-ma/bw 8 supplying and erecting mains with 2x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 9 supplying and erecting green earth wire 1x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 10 supplying and erecting mains with 4x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 11 supplying and erecting mains with 2x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 12 supplying and erecting mains with 4x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 13 supplying and erecting green earth wire 1x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 14 supplying and erecting mains with 4x6 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg-ma/bw 15 supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper industrial cable for voltage grade up to 1.1 kv 16 supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper industrial cable for voltage grade up to 1.1 kv 17 supplying and erectingceiling rose / batten holder / slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6a. erected on filled polypropylene board or polished double wooden block/ pvc junction box. 18 supplying and erectingmodular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. 19 supplying and erectingmodular type switch 16aduly erected on provided plate and box with wiring connections complete. 20 supplying and erectingmodular type bell-push with indicator 2 modules 6a / 10a, duly erected on provided plate and box with wiring connections complete. 21 supplying and erectingmodular type 3 pin 6amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. 22 supplying and erectingmodular type 3 pin 6 / 16amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete. 23 supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. 24 supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. 25 supplying and erecting pvc surface modular switch box with double mounting plate for 2module duly erected. 26 supplying and erecting pvc surface modular switch box with double mounting plate for 3module duly erected. 27 supplying and erecting pvc surface modular switch box with double mounting plate for 6module duly erected. 28 supplying and erecting pvc surface modular switch box with double mounting plate for 12module duly erected. 29 supplying and erecting 16 / 20 / 25 a starter (modular range) 2 module for ac unit on provided box complete & duly concealed with necessary material and connected. 30 point wiring for light/bell/exhaust fan in pvc trunking (casing-capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthingand required accessories as per specification no: wg-pw/sw 31 point wiring for ceiling fan in pvc trunking (casing-capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthingand required accessories as per specification no: wg-pw/sw 32 wiring for plug on board withswitch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no: wg-pw/cw 33 supplying and erectingled square / circular max. 11 w down lighter/panel light having pressure die-cast aluminium housing,polystyrene diffuser havingsystem lumens output of min. 1200 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50,including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 34 supplying and erectingled square / circular max. 14 w down lighter/panel light having pressure die-cast aluminium housing,polystyrene diffuser havingsystem lumens output of min. 1500 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50,including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 35 supplying and erectingled square / circular max. 18 w down lighter/ panel light having pressure die-cast aluminium housing,polystyrene diffuser having system lumens output of min. 2000 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 36 supplying and erectingledpanel light(600mm x 600mm) max. 30 whaving crca powder coated housing,polystyrene diffuser havingsystem lumens output of min. 3600 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%,thd<10%, p.f. >0.95, operating range of120-270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 37 supplying and erecting anodized aluminium corridor / passage / mirror light led fitting (2 feet) max. 12wwith high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6000k, beam angle of 110 deg., ripple<5%,thd<10%,p.f. >0.95, operating range of200-270v, surge protection of 2 kv, life class of 50,000 hrs. at l70b50, including driver with end caps on provided pvc block / wooden board with 3 years warranty. 38 supplying & erecting inverter led batten 10w tube light fitting with polycarbonate housing, heat sink, integrated hf electronic driver, min. 2600 mah lithium ion battery with charging time of 8-10 hours and backup time of min. 3 hrs. with minimum 25% of initial watts having luminous efficacy of 100 lumen/watt,cri>80, cct of 6500k and thd<=20% havinguseful life of minimum 25000 hrs. with overheating protection with 2 years warranty. 39 supplying & erecting inverter led batten 20w tube light fitting with polycarbonate housing, heat sink, integrated hf electronic driver, min. 2600 mah lithium ion battery with charging time of 8-10 hours and backup time of min. 3 hrs. with minimum 25% of initial watts having luminous efficacy of 100 lumen/watt,cri>80, cct of 6500k and thd<=20% havinguseful life of minimum 25000 hrs. with overheating protection with 2 years warranty. 40 supplying and erecting ding dong / electronic musical type call bell with heavy duty coilsuitable to operate on 230v a.c. supply erected on polished double wooden block/sunmica block of suitable size. 41 supplying and erecting integrated led street light fitting26 to 30w ip65 & ik08 class having single piece pressure die-cast aluminium housing ,having system lumens output of min. 2600 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of140-270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50,including driver complete with 3 years warranty as per specification nofg-odf/fls2. 42 supplying and erecting integrated led street light fitting 40 to 50w ip65 & ik08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of min. 4400 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd<10%, p.f. >0.95, operating range of140-270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification nofg-odf/fls2. 43 supplying and erecting integratedled street light fitting 100-110w ip65 & ik08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of min. 11000 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of140-270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50,including driver complete with 3 years warranty as per specification nofg-odf/fls2. 44 supplying & erecting integral post top lantern fixtures (mushroom type) suitable for led lamp upto 12 w consisting of clear acrylic top cover, cast aluminium pole cap complete with accessories on provided pole /bracket as per specification no. fg-odf/ptl 45 supplying and erecting street light wall bracket made from 40 mm. dia ‘ g.i. pipe 1.2 m. in total length complete as per specification no. fg-bkt/wb 46 supplying & erecting 3w, 230v integral type led lamp suitable for b-22 / e-27 base.(night lamp) 47 supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. fg-fn/cf 48 supplying and erecting bracket fan 400 mm. sweep a. c. 230 volts 50 cycles 1350 rpm. oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘e’ class insulation. 49 supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm rust proof body & blades, wire mesh, duly erected, complete. 50 supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 375/380 mm. 1400 rpm complete erected in position as per specification no. fg-fn/exf 51 supplying and erectingenergy saving ceiling fan 230 v a.c. 50 cycles 1200 mm complete erected in position as per specification no. fg-fn/cf 52 supplying and erecting fan hook of 10 mm. m.s. round bar grouted in rcc slab with making the site as original. 53 providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. 54 supplying & erecting 22 swg g.i sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 400 mm as per specification no fg-fas/msc 55 supplying and erecting midget type 3.0 litres instant type water heater of rustproof & shockproof abs plastic body, high grade ss inner tank & 3kw heating element with corrosion & hard water protection, with minimum 3 safety protections (i.e. thermostat & thermalcut-out, function valve) complete with 6.5 bar pressure withstanding capacity 230/250v, 50hz, a.c. supply with inlet and outlet, with 3 core pvc flexible copper wire leads duly tested and marking sr. no. and date of erection complete. 56 supplying and erecting chromium plated heavy duty brass stop cock for inlet pipe of water heater (15mm. dia). 57 supplying & erecting 15mm brass non return valve for inlet pipe of storage water heater. 58 providing fiber reinforced pvc flexible pipe upto 1m length with brass locking nuts and washers and clips at both ends suitable for hot water and cold water both (1 set of 2 nos.) complete. 59 supplying, installing, testing & commissioning split type variable speed invertertechnology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac 60 supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7tr to 2.0tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac 61 supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with rohs compliant suitable for refrigerant having 22swg thickness and inner dia/size 12mm complete. 62 supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with rohs compliant suitable for refrigeranthaving 22swg thickness and inner dia/size 16mm complete. 63 supplying, erecting, testing and commissioning self contained water cooler 230/250v 50hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. ap-wcr/wc 64 supplying, erecting, testing and commissioning self contained water cooler 230/250v 50hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. ap-wcr/wc 65 supplying and erecting ultra violet storage type water purifier (ro+uv+uf) with softener for safe drinking water consisting of uv germicidal tube of 8w capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230v, single phase a.c. supply with uv fail & filter change indication system .(for tds more than 200) 66 supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 1400 to 1600va digital pure sine waveinverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology completeas per specification no.ap-inv 67 supplying and erecting 12v/180ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 68 supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160-270v and output voltage 200-250v rated for 3kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top with overload & short circuit protection complete. 69 supplying and erecting switch disconnector fuse (sdf) switch 415v, 100a,open execution, four poleac23 a rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to is/iec 60947-3 part-1/3hrc - din type fuse, insulation voltage 1000 vfor enclosing in panel with rotary handle for on / off operation (without hrc fuse) 70 supplying & erecting three phase, 415v, street light control panel up to the max load of 6kw, tpn mcb 40a,powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / cc foundation. 71 supplying, erecting & marking spmcb 0.5a to 5a, c-series with rated short - circuit breaking capacity (icn) 10kain provided distribution board as per specification no. sw-swr/mcb 72 supplying, erecting & marking spmcb 6a to 32a, c-serieswith rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 73 supplying, erecting & marking spmcb 6a to 32a, b-series with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 74 supplying, erecting & marking dpmcb 6 a to 32 a, b-series with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 75 supplying, erecting & marking tpmcb 6a to 32a, with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 76 supplying, erecting & marking tpmcb 40a to 63a, with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-swr/mcb 77 supplying, erectingand marking double pole isolator only switch version of miniature circuit breakerof40awith required wiring connections and lugs etc. in provided distribution board. 78 supplying, erecting and markingfour pole isolators only switch version of miniature circuit breakers of 40a in provided distribution board. 79 supplying, erecting and markingfour pole isolators only switch version of miniature circuit breakers of 63ain provided distribution board. 80 supplying&erectingtriplepole and neutral distribution board (tpndb), sp/tp mcbs total 4 ways /12 poles, with door, 1.2mm thickness surface/flushmounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw-swr/mcbdb 81 supplyingand erecting single pole and neutral distributionboard (spndb), with 2 ways for incoming and 6 ways (6 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw-swr/mcbdb 82 supplying & erecting crca sheet metal one way enclosures of 1.2mm thickness suitable for dp mcb /tp mcb/fp mcb/rccb/rcbo complete erected on angle iron/gi frame. 83 supplying & erecting triple pole and neutral distribution board (tpndb), 3 pole/4 pole mccb as incomer & outgoing sp mcb (36 poles) or tp mcb of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/gi frame (vertical busbar type) as per specification no. sw-swr/mcbdb1 84 providing & erecting 4 pole mccb, 415 v, 100a, rated short-circuit breaking capacity 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/uv/trip alarm contact.mccb with phase barriers on both sides, insulation withstand capacity 800v, no line-load bias in provided enclosure/panel as per specification no. sw-swr/mccb (rate of 3 pole mccb +20% for 4 pole mccb= 5309x20%+5309=6370.80) 85 supplying and erecting cupboard for enclosing switchgears orforany other purposemadefromselected marine plywood planks 19 mm thick duly varnished/ painted from inside and from outside with brass hinges and locking arrangement with suitable lock with keys in duplicate. cupboard shall be duly grouted with suitable size of iron work in wall at the bottom. (size of cupboard 0.5x1x2+0.5x1x2+1x1x2= 4 sq.mtrs.) 86 supplyinganderectingiron, sheet metal work consisting of crcasheets, varioussectionsofiron,plates, chequeredplates,rods,bars,mspipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. ( 50x50x4mm angle @ 3.4 kgs x 6 mtrs.= 20.40 kgs i,e 20 kgs. 87 supplying and erecting 525 v 3 phase, 50 hz., mpp type capacitor having minimum overcurrent capacity of 1.8 in,peak inrush current capacity 300 inand minimum life 150000 hourskvarbank of all polypropylenecondensers (app)withthestandard capacities of 2, 3, 5, 7, 10, 12.5 and 15 kvarunitsofp.f. correctionforoperationon 3 phase 50 hz. with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and providedwithterminalcoverbox completeerected onprovidediron bracketoronfloordulytestedby licensee.( original p.f=0.8 desired p.f = 0.95 for this multiplying factor is 0.421. so 0.421 x 46.440 = 19.55 i.e 10 kvar x 2= 20 kvar) 88 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb-lt/al 89 supplying, erecting & terminatingfr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3½ core50 sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb-lt/al (double run) 90 supplying, erecting & terminatingfr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb-lt/al 91 supplying & erecting g.i. pipe‘a’ class 50 mmdia.erectedfor enclosingxlpearmouredcable on wall/poleas per specification no. cb-ce 92 supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(dwc) ofhdpe for enclosing cable below ground/road surface, to required depth complete. 93 supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mmoutside dia. double wall corrugatedpipes (dwc) ofhdpe for enclosing cable below ground/road surface, to required depth complete. 94 supplying & erectingcast iron cable indicatorplate buried along with route of cable for pvc / xlpe armoured cableas per specification no. cb-cip 95 supplying & erecting frp box of size 150mm x 125mm x 100 mm, 2.7 mm thickcomplete on pole/wallas per specification no. cb-sb 96 providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh-pl/opl 97 providing and erecting galvanised 1000mm single arm sword type bracket with frp dome and ball as per specification no. oh-pl/pbkt 98 providing and erecting galvanised 1000mm double arm sword type bracket with frp dome and ball as per specification no. oh-pl/pbkt 99 providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. ea-ep 100 providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results asper specification no. ea-ep 101 providingpipetype earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rodcomplete with all materials testing and recording the results as per specification no. ea-ep 102 supplying and erecting gi strip of required size used for earthing on wall and/or any other purpose with necessary gi clampsfixed on wall painted with insulating and non-corrosive bond with requiredjointsas per specification no. ea-ep.(25x3mm strip. perpole 1.5 mtrs. so for 13 poles 13nos.x1.5mtrs.= 19.5 mtrs. weight of strip @0.590kgs/mtr. so 19.50mtrs.x0.590kgs.=11.51 kgs.) 103 supplying and erecting minimum three & above star rated 1 phase, 230 v, 50 hz, submersible pump set of 1.5 kw/2hp suitable for erection on open well, pump having delivery head from 29to 7 m and discharge from 30 to 600 litres. . per minute& pipe of suction 50 mm/delivery 50 mm diameter erected with necessary h type clamps as per specification no. wp-osp 104 supplying & erecting flat flexible 3 core 4 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. 105 supplying & erecting automatic control panel for 1 ph, 230 volt, a.c. submersible/centrifugal pump set up to 3 hp consisting of dol starter of suitable relay range s.p.p., combined ammeter/ voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. 106 supplying & erecting carbon dioxide (co2) fire extinguisher of 4.5 kg. capacity cartridge type conform to is 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. m. s. flat with nut & bolts routed in wall complete. 107 making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (02x02x02 foundation for main control panel stand and for street light control panel 0.2x0.2x0.2mtr.=0.16 cu.mtrs.) 108 makingm- 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 t/sq.mat 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical gi pole). 109 supplying and erecting isi mark gi pipe 50 mm dia.‘b’ class at position with accessories complete as per specification no. cw-plb/gp. 110 supplying and erecting high density polythene pipe isi mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected tojet/submersible pump with required material complete. 111 supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete. 112 supplying and erecting non return valve 50 mm dia in position made of gun metal complete. 113 lum sump provision towards service connection charges1 no.3 phase @ rs. 55000/-/per total rs.55,000/-
  • View Tender
  • Document
  • Bid Support
3 Housing Urban And Rular Development
image image
Local Bodies
TRN :49022842 |  16 May, 2025
Tender Value : 8.07 Lacs
 Raebareli - Uttar Pradesh
Tender for tender for construction work of 04 m.m.i.g. buildings in amol vihar yojna - earth workinfoundation in ordinary soil ( loamclay,or sand) including lift upto 1.5 metre ( 5fts) and lead upto 30m. (100fts.)andincludingfilling watering and raming of excavatedearthintotheplinth and removal anddisposalof surplus earth and directedby the engineer - in - chargeupto a distance of 30m. ( 100 fts ) from the foundation trenches. 2 earth work in cutting or in embankment in ordinary soil, excavation to be in form of regularpitsnotexceeding1/2 mt (20) in depth and earthwork inembankmenttobein20cm (8) layers, including ramming anddressingthesurfaceto requiredlevelsandslopesand alsoincluding1.5mts(5fts)lifts and 30mt (100fts) lead. the earth from cutting to be used in makingembankmentsortobe deposited as spoil banks with in30mts(100fts)distanceas directedbytheengineerin charge,includingcartageof8km. 3 concrete with4cm. (1*1/2) gauge brick ballast, fine local sand of 1.25 fineness modulous andcementin proportion of 8: 4:1infoundationsand under floors, includingsupply of allmaterials,labourand t&p etc.requiredforpropercompletion of the work. 4 providingandlayinginposition specified grade of reinforced cement concrete, excluding cost of centering, shuttering, finishing and reinforcement in 1: 11/2 : 3 ( 1 cement, 11/2 coarse sand , 3 20mm graded stone aggregate. 5 foundations,footings,basesof columns, etc. for massconcrete 6 columns,pillars,piers,abutments, posts and struts 7 suspended floors, roofs, landings, balconies and accessplatform 8 mildsteelorironinplain worksuchasreinforced concreteorreinforced,brick work(when notincluded inan over all rates ) wroughtto required shapeasnecessary includingbendingforproper completion of the work and including supply of steel its wastagebendhooksand authorised over lapping shallbemeasured. 9 brick work in comman burnt clay (non-modular)bricks of class 150 in super structure aboveplinthlevelincluding supplyoflabour,materialand t&prequiredforproper completionofworkincement mortar 1:6 ( 1 cement: 6 coarsesand) 10 class150 brick work in1:4 cementand coarsesand mortarinsuper - structureforwallthickness 12 cms 11 12mmthickcementplasterof mix1:4(1cement:4coarsesand) 12 providing &layingof lightcinderfillingunderfloorof toilets & other sunken roofs. 13 providingandfixinginwall unplasticisedrigidpvcrain waterpipesconformingtois: 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermalexpansion,(i)singlesocketed pipes. 110 mm dia 14 providingwoodworkinframe ofdoors,windows,celerestory windowsandotherframes, wrought frames and fixed in positionwithholdfastlugsor withdashfastnersofrequired dia and lenghts (hold fast lugs or dashfastnersshallbepaidforseperately): sal wood 15 providingandfixingangleiron framesfordoors,windowsand ventilatorsofmildsteelangle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing t- ironframeortothewallwith dash fastener, including fixing of necessary butt hinges and screwsandapplyingapriming coatofapprovedsteelprimer, all complete as per the direction ofengineer-in-charge.(fordoorframes) 16 providingandfixingisimarked flush door shutter confirming to is:2202(part1)non-decorative type, core of blockboard constructionwithframeoffirst classhardwood andwell matched commercial 3 ply veneering with vertical grains or cross bands and face vineers on both facesof shutters:35mm thick including isi marked stainlesssteelbutthingeswithnecessary screws. 17 providingandfixingwiregauge shutterusinggalvanisedms wiregaugeofaveragewidthof apurture1.4mminboth directionwithwireofdia 0.63mm for doors, windows and celestorywindowswithhinges and necessary screws. 35mm thick shutter, with isi marked mspressedbutthingesbright finished of required size withsecond class teak wood. 18 steelworkweldedinbuiltup sections/framedwork, including cutting, hoisting, fixing inpositionandapplyinga primingcoatofapprovedsteel primer using structural steel etc. asrequired.ingratings,frames, guard bar, ladder, railings, brackets,gatesandsimilarworks(forwindow grills) 19 providingandfixingaluminium towerbolts,isimarked, anodised (anodic coating not lessthangradeac10asper is:1868) transperent ordyed to required colour or shed, withnecessary screws etc. complete. 150 x 10mm+ 20 250 x 10 21 providingandfixingaluminium sliding door bolts, isi marked anodised anodic coating not less thangradeac10asperis: 1868),transparentordyedto requiredcolourorshade,with nutsandscrewsetc.complete:250x16 mm 22 providingandfixingaluminium hangingfloordoorstopper,isi markedanodised(anodic coatingnotlessthangradeac-10asperis:1868)transparent ordyedtorequiredcolourand shed, with necessary screws etccomplete. twin rubber stopper. 23 mildsteelorironwork of heavy sizes and sections such as holdingdownbolts,holdfast, tie, rods gratings etc (when not included in an over all rates) wrought to required form, includingsupplyofsteel,bolts, nutsandwastageetcandtheir fixingrequiredtoproper completionofwork.(fortubular stair case railing) 24 providingandlayingvitrified floortilesindifferentsizes (thickness to be specified by the manufacturer) with water absorptionlessthan0.08%and conforming to is : 15622, of approved make, in allcolours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarsesand),includinggrouting the joints with white cement and matching pigmentsetc.,complete. size of tile 600x600 mm 25 providingand laying vitrified tilesin differentsizes (thickness tobespecifiedby manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in allcolours &shade,inskirting,riserof steps,over12mmthickbedof cement mortar 1:3 (1 cement: 3 coarsesand),includinggrouting thejointwithwhitecement& matching pigments etc.complete. size (600x600) 26 marblestoneflooringwith18 mmthickmarblestone,asper sampleofmarbleapprovedby engineer-in-charge, over 20 mm (average)thickbaseofcement mortar 1:4 (1 cement : 4 coarse sand) laid and jointedwith grey cement slurry, including rubbingand polishing complete with : udaipur green marble 27 providingandfixingfirstquality ceramic glazed wall tile confirmingtois:15622 (thickness to be specified by the manufacturer)ofapproved makeinallcolours,sheds exceptburgandy,bottlegreen, black of any size as approved by engineerincharge,inskirting, rizersofstepanddados,over 12mmthickbedofcement mortar1:3(1cement:3coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mix with pigment ofmatching shed complete. 28 providing and laying ceramic glazed floor tiles of size 300x300 mm(thicknesstobespecified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours suchaswhite,ivory,grey, fume red brown, laid on 20 mm thickcementmortar1:4(1 cement : 4 coarse sand), includingpointingthejoints with white cement and matchingpigment etc, complete. 29 providing and applying white cementbasedputtyofaverage thickness1mm,ofapproved brand and manufacturer, over the plastered wall surface to prepare the surface even andsmooth complete. 30 finishing walls with acrylic smoothexteriorpaintof required shade on new work (twoormorecoatapplied@1.67ltr/10sqmoverand includingprimingcoatof exterior primer applied @ 2.20kg/ 10 sqm) 31 wallpaintingwithacrylic emulsionpaint,havingvoc (volatile organic compound ) content less than 50 grams/ litre, of approved brand and manufacture,includingapplying additional coats wherever required, to achieve even shadeand colour. two coats 32 paintingwithsyntheticenamel paint of approved brand and manufactureofrequiredcolour togiveanevenshade:twoor morecoatsonnewworkover an undercoatofsuitable shade with ordinary paint of approvedbrand and manufacture 33 providing and fixing white vitreouschinapedestaltype water closet (european type) withseatandlid,10litrelow level white vitreous china flushingcistern&c.p. flush bend with fittings & c.i.brackets,40 mm flush bend, overflow arrangement with specials of standard make and mosquito proofcouplingofapproved municipaldesigncomplete, including painting of fittings and brackets, cutting and making good thewallsandfloorswherever required : w.c. pan with isi markedwhitesolid plastic seat and lid 34 providingandfixingwashbasin withc.i.brackets,15mmc.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making goodthewallswhereverrequire: whitevitreouschinawash basin size 630x450 mm with a pairof15mmc.p.brasspillartaps 35 providing and fixing p.v.c. waste pipe for sink or wash basin including p.v.c. waste fittingscomplete. semi rigid pipe 32 mm dia 36 providing and fixing cp brass bibcock of approved quality confirming to is: 8931 15mm nominal bore. 37 s/f of 15mm nominal bore cpvc pipe all complete. 38 providing and fixing cp brass angle valve for basin mixer and geyser points of approved quality confirming to is:8931 15mm nominal bore. 39 15mm nominal boare 40 providing and fixing cp brass shower mixer of 15 or 20mm bore including cp brass connection with angle valve of standard design and approved make confirming to is:8931 41 providing and fixing cp brassover head shower with 15 or 20 mm inlet including connection complete: 100mm diameter. 42 providing and fixing trap of selfcleansing design with screwed down or hinged grating with or with out vent arm complete, including cost of cutting chases and making good the walls and floors:100mm inlet and 100mm out let pvc 43 100mm inlet and 75mm outlet pvc 44 providing and placing on terrace (at all floor levels) polyethylene water storage tank, isi : 12701 marked, with cover and suitable locking arrangement andmaking necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 45 providing, fixing and jointing pvc pipes of different diameters with with pvc solvent cement (or as per manufacturers specifications) with or without sockets (if sockets are provided with pipe length) in vertical sewage line, waste water line and vent line with all necessary bends, angle bends, tees, elbows ms bat clamps along with all necessary fastners and bolt with cutting chases and making good the walls and floors wherever required including testing of the same all as per direction and satisfaction of engineer in charge.6kg per sqin pressure pipe75mm inner dia. 46 6kg per sqin pressure pipe110mm inner dia. 47 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot and cold water supply, including all cpvc plain and brass threaded fittings, including fixing the pipe with clamps 1.00m spacing. this includes jointing the pipes and fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 15mm nominal outer dia pipes. 48 25mm nominal outer dia pipes. 49 constructing masonary chamber 30x30x50cminside,inbrick workincementmortar1:4(1 cement:4coarsesand),with ci surface box 100x100x75 mm(inside)withhingecover fixed in cement concrete slab 1:2:4 ( 1 cement : 2 coarse sand:4 graded stone aggregate 20mm nominal size) including necessary excavation, foundationconcrete1:5:10(1cement:5finesand:10graded stoneaggregate40mmnominal size)andinsideplasteringwith cement mortar1:3 ( 1 cement : 3coarsesand)12mmthick, finishedwithafloatingcoatof neat cement complete as perstandard design: 50 supply delivery errection the fabricatedmsboardofsuitable sizeonwhichthefollowing supplieditemsshallbefixedas per the direction of enggincharge. 51 (a)supply and fixing 63 ampdoublepole(singlephase &neutral)240voltresidual currentcircuitbreakerrccb havingasensivitycurrentup to300 ma on the existing ms board complete with connection testing&commissioningetcas required. 52 (b)supplying & fixing 2+8way single door prewired sp&n mcb distribution board of sheet steel for240voltonexistingms board complete with dpmcb isolator40amp240volt1no& 25amp single pole240 volt spmcb(c)series5nos completeduly wired with 4sqmm fr pvc insulated copper conductorupto terminal box tinned copper busbar ditachable gland plate, inter connection phosphotized &powder coated includingearthingetcasreq( for power distribution ) 53 (c)supplying & fixing 2+8way single door prewired sp&n mcb distribution board of sheet steel for240voltonexistingms board complete with dpmcb isolator40amp240volt1no& 10amp single pole240 volt spmcb(c)series5nos completeduly wired with 4sqmm fr pvc insulated copper conductorupto terminal box tinned copper busbar ditachable gland plate, inter connection phosphotized &powder coated includingearthingetcasreq( for light distribution ) 54 wiring point for lightwith 1.5sq mmfrpvcinsulated multistrandsinglecorecopper conductorcableinpvcconduit concealedinthewallcomplete with modulartype switch &ceilingrose/angle/batten holderon3mmthickphenolic laminated backalite sheet etc comp in all respect 55 wiringpointforfan 1.5sq mmfrpvcinsulated multistrandsinglecorecopper conductorcableinpvcconduit concealedinthewallcomplete with modulartype switch &ceiling roseon3mmthick phenolic laminated backalite sheet &fan boxetccompin all respect 56 wiringpointfor freshairfan with 1.5sq mmfrpvc insulated multistrandsinglecorecopper conductorcableinpvcconduit concealedinthewallcomplete with modulartype switch &ceiling roseon3mmthick phenolic laminated backalite sheetetc comp in all respect 57 supply&fixing5ampmodular switch & 5amp 5pin modular socketontheexistingmodular plateandswitchboxincluding connection etc as reqd. 58 supply&fixingofpowerplug 20amp250voltflushtype modular switch& 5pin 20amp 250voltmodular socket on concealedmsbox etc.asrequered 59 supply & wiring for power pointwith2no4sqmmfrpvc insulated1100voltgrade multistrandsinglecorecopper conductor cable in 20mm dia heavydutypvcconduitwith1 no2.5sqmmfrpvcinsulated multistrandcopperconductor cable as earth continuity wire in conduit etc as required 60 wiringofcircuitalongwith earth wire with the following size of fr pvc insutated copper conductorsinglecorecablein recessed medium class 20mm dia pvc conduit as required 61 1x1.5sqmm+1x1.5sqmm 62 supply & fixing of electronic fan regulatormodular400w 120v-- 280v isi marked on existing switchboard includingmaking connection etc for proper completion of work 63 supply&burryingofsafe earthingelectrodet-19zn-zinc coated,lengthupto3000mm, outer pipe 48.4mmx3.2mm, inner pipe 26.9mmx2.6mm, terminaldia12mm,coating80- 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc)capable of reducingthe soilresistivitywith good mixture of retaining capacityandoneearthinglead of 20mmx3mmg.i. strip,up to switch board (from apron to switchboard,thecostofg.i. strip will be extra)along with 30cm square c.i. frame with hinged cover & masonary housing 64 supplying&layingof 20mmx3mm g.i. strip directly in ground&onwallasrequired complete in all respect (from apron to switch board. 65 wiring for submain withthe 2x10sqmm size fr pvc insulated copper conductor cable in recessedmediumclasspvcconduit as required 66 boring with hydraulic piling rigs with power units, providing and installingcastinsitusingleunder reamedpilesofspecifieddiameter andlengthbelowpilecapinm-25 cementconcrete,tocarryasafe working load not less than specified, excluding the cost of steel reinforcement but including thecostofboringwithbentonite solutionandthelengthofthepile to be embedded in pile cap etc. all complete.(lengthofpilefor payment shall be measured upto tothe bottom of pile cap) : 300 mm dia piles 67 s/f of kitchen sink including all labour and t&p all complete. 68 15mm thick plaster in 1:4 (1 cement and 4 coarse sand) including all labour complete. 69 s/f of gate valve including all labour and t&p all complete 70 s/f pvc bulb holder including all labour and t&p all complete 71 s/f aluminium door handle including all labour and t&p all complete 72 s/f of chequered tiles on ramp of house including all labour and t&p all complete 73 s/f flange bib cock with z spray including all labour and t&p all complete 74 s/f of kota stone on rear court yard anf front porch of house including all labour and t&p all complete 75 s/f of granite stone on kitchen top of house including all labour and t&p all complete 76 s/f of basin mixture including all labour and t&p all complete 77 s/f of 25mm cpvc pipe including all labour and t&p all complete
  • View Tender
  • Document
  • Bid Support
4 Air Transport
image image
Central Government/Public Sector
TRN :34430390 |  15 May, 2025
Tender Value : 162.49 Crore
 Ayodhya - Uttar Pradesh
Tender for construction of new domestic terminal building
  • View Tender
  • Document
  • Bid Support
5 Air Transport
image image
Central Government/Public Sector
TRN :34430408 |  13 May, 2025
Tender Value : 70.00 Lacs
 Aurangabad (Mh) - Maharashtra
Tender for annual maintenance contract of civil works in aai residential colony, non-operational area, city side area of terminal building and cargo
  • View Tender
  • Document
  • Bid Support
6 Air Transport
image image
Central Government/Public Sector
TRN :34411478 |  10 May, 2025
Tender Value : 58.49 Lacs
 Ranchi - Jharkhand
Tender for reconfiguration of existing terminal building b m airport ranchi. sh- fire alarm and fire fighting system.
  • View Tender
  • Document
  • Bid Support
7 Air Transport
image image
Central Government/Public Sector
TRN :34411514 |  12 May, 2025
Tender Value : 68.0 Thousand
 Mysore - Karnataka
Tender for license for operating snack bar at security hold area sha in terminal building of mysuru airport
  • View Tender
  • Document
  • Bid Support
8 Security Services
image image
Central Government/Public Sector
TRN :34415149 |  12 May, 2025
Tender Value : 0
 Baramulla - Jammu And Kashmir
Tender for gem bids for change over switch havells 32 amp , bed switch 6 amp , mcb 32 amp dp , insulation tape 10 mtr long , flexible wire 0.75mm , exaust fan 300mm , wall mounting fan , switch socket combination 2 in 1 16 amp with box , led street light 60 watt , led bulb 12 w , led tube light fitting 10 watt 2 ft long , led tube light fitting 18 22 watt 4 ft long , teek wood switch board 8 inch x 10 inch , pvc insulated unsheathed single core flexible copper conmductor1100w grade of size 1.5 sqmm , gavin box , mcb 06 amp sp , mcb 16 ampdp , pvc insulated unsheathedsingle core flexible copper conmductor1100w grade of size 2.5 sqmm , pvc cashing caping , plug top 3 pin 5 amp , pvc wire 10 sqmm 2 core , pvc wire 6 sqmm wire 2 core , modular switch 6 amp , modular socket 2 obliq 3 6 amp , modular socket 2 obliq 3 16 amp , main switch 16 amp , m seal 100gm each pkt , nails 2 inch 3 inch 4 inch 6 inch , ldpe sheet , prong copper complete set , gi pipe 20mm dia med grade , aluminium strip , copper crown set , earth cylender , clamp , painting brush 3 inch 4 inch and 5 inch , brass bib cock 15mm pvc , gi elbow 15mm , water storage tank 500 ltrs , gi elbow 20mm , gi nipple 15 mm 3 inch , gi nipple 15 mm 4 inch , brass bib cock 20mm , water storage tank 1000 ltrs , plywood 8 feet x 4 feet x 6mm , looking mirror 600mm x 450mm , ismb 150 x 75 mm 5.70 mtr long , acrylic sheet 6 feet x 3 feet x 3mm , fire extingusher 2 kg capacity abc map 90 , oil bound distemper , plywood 6 feet x 4 feet x 10mm , synthetic enamel paint red , synthetic enamel paint og , synthetic enamel paint green , common building bricks , concrete hollow blocks , thinner , ballies 4 inch dia 10 feet 8 feet long , ballies 6 inch dia 10 feet 8 feet long , varnish , cgi sheet 6ft , gi pipe 15mm dia med grade , led street light 36 watt , hdpe sand bag , srt , ceiling rose , paint og black white , gi erth plate , salt crystal type for lc , polythene sheet heavy duty , lighting terminal copper with 5 no prong 15cm long complete , hdpe sheet , plywood for floor 4 feet x 6 feet x9mm , false ceiling 1515x1210mm , ms wall plate , ismb 3.75mtr long , cgi sheet 10 feet , cgi sheet 8 ft , ply wood 10mm thick as per reqmt for flat surface for roof , ply wood 4450mmx150mm and 12mm thick for shuttering of rcc plinth beam , bullet proof glass 610mmx330mmx72mm , white cement 1 kg pack , pvc pipe110mm dia 3mtr long , pbs roll , gi union 20mm , gi socket 20mm , tower bolt , hinges 5 inch , paint og , nails 3 inch , nails 4 inch , pvc flushing 10 ltr capacity , rock salt , charcoal with out dust best quality , lighting air terminal with five copper prongs , earthing electrode pipe , paint white , brass stop cock 20mm , wc indian type 440mm , glass putty , rope , vitreous china wash hand basin of size 580mm x 440mm , door frame df 1000x2100 mm , hacksaw blade double end , hand wash basin of size 580mm x 440mm , hanger stand 450mm with 6 hook , self taping screw 55 mm , taping screw 3 inch , vertified tile 1 feet x1feet , vitreous europen type wc , waste pipe 32mm dia with coupling , water storage tank 2000 ltrs , wss joint nipple dia 1inch , wss pipe , taping screw 1 inch sds , natural sand , hollow block , agg 20mm
  • View Tender
  • Document
  • Bid Support
9 Security Services
image image
Central Government/Public Sector
TRN :34405726 |  08 May, 2025
Tender Value : 0
 Baramulla - Jammu And Kashmir
Tender for gem bids for pre fabricated shelter made up of steel structure and hybrid pir panels in wall , fire extinguisher of capacity 2 kgs along with its accessories confirming to is 13849 two nos with each shelter , heating device kerosene based two nos heating , lightning conductor. lightning conductor will be provided as under and stores are as per appx e and drg at appx f sheet 10 10 , aggregate 20mm. stone aggregate to be crushed rock , aggregate 40mm. stone aggregate to be crushed rock , manufactured sand m sand confirming to is 383 2016 specifications for coarse and fine aggregates , bricks common burnt clay building bricks sub class b , white cement make- birla white jk cement acc packet 01 kg , water proof floor silica panels of size 600 x 600 mm with minimum thickness of 10 mm , non skid ceramic tiles coloured 7 to 8 mm thick in floors etc , prefabricated foundation reinforcement type f 2 made of 12 mm and 10 mm for steel as main bars and 8 mm dia deformed bars as in stirrups including cutting bending , form work type 2 timber form work material for columns of size 0.3 x 0.3 x 0.9m and columns footing of size 0.9 x 0.9 x 0.3 m , rapidite quick setting liquid. , ms clamp msde of ms flat 40 x 4 mm 200mm long bent in l shape with two holes of 12mm dia on each end. 04 x nut and bolt of size 10 x 50 mm with washer. , pvc ceiling rose 2 obliq 3 terminal make anchor pilot 3 plate , led tube light fitting 1 x 18w 4 feet long complete with all , xlpe insulated pvc seathed heavy duty armoured multi core cable 16 sqmm 2 core aluminum conductor for working voltage up to and including , cable pvc insulated unsheathed single core flexible copper conductor 1100v grade of size 1.5 sqmm , cable pvc insulated unsheathed single core flexible copper conductor
  • View Tender
  • Document
  • Bid Support
10 Housing Urban And Rular Development
image image
Local Bodies
TRN :48606691 |  15 May, 2025
Tender Value : 56.65 Crore
 Prayagraj - Uttar Pradesh
Tender for tender for kareli - nurulla road to askari market road block c and block d housing scheme and nurulla road from mahavir chauraha to karamat ki chowki near sasur khedari river and also till the connecting road - clearing grass and removal of rubbish upto a distance of 30 m outside the periphery of the area as per technical specification clause 201. 3 dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including t&p and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 60 metres as per instructions of e-i-c. (by mechanical means). 4 i) cement concrete 5 ii) reinforced cement concrete/ r.b. 6 dismantling of flexible pavements and disposal of dismantled material up to a lead of 100 m, stacking serviceable and unserviceable materials separately as per technical specification clause 202. bituminous / granular courses (by mechanical means) 7 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 8 removing all type of hume pipes and stacking within a lead of 1000 metres including t&p, earthwork and dismantling of masonry works. 9 (i) up to 600 mm dia 10 removal of telephone / electric poles / street light / lamp post including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately 11 disposal of moorum/building rubbish malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of engineer-in-charge. note- item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. 12 dewatering using 10hp to 70hp diesel engine pump set including hire charges, cost of diesel, engine oil, pump operator, labor charges, conveyance of pump set and fuel to site and back, loading, unloading and any other incidental charges etc., complete. (hire charges for diesel pump set for 10 hp) 13 [b] bill no. 2 - earthworks 14 excavation for road work in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and leading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections and transporting to the embankment location within all lifts and lead upto 1000m 15 removal of unserviceable soil including excavation loading and disposal but excluding replacement by suitable soil which shall be paid separately as per clause 305 16 i) lead upto 1000 m 17 ii) lead upto 8000 m 18 earth work in excavation of foundation of structures as per drawing and technical specification, including setting out construction of shoring and bracing, removal of stumps and other deleterious matter dressing of sides and bottom, backfilling the excavation earth to the extent required and utilizing the remaining earth locally for road work. 19 mechanical means (depth upto 1.5 m) 20 i) excavation 21 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 22 [c] bill no. 3 - development of carriageway 23 stabilization of in-situ (existing pavement crust) or soil or otherwise sub base/ base course up to the required depth by cold in-situ recycling using cement and chemical additives / otherwise: providing pulverizing, spreading, milling and mixing of chemical additives at the appropriate rate as per job mix design in accordance with irc-sp-72-2015 , irc-37-2012 & 2018 and irc sp 89 (part ii) 2018. cementitious additive @ rate of minimum 5 - 7% and ccs/cs additive should be spread on the existing pavement using a mobile truck mounted containerized cement/ additive spreader with micro processor controlled weighing and spreading system. the additive spreader shall have variable working width sufficient to cover whole pavement lane. the in-situ stabilization process shall be carried out by a mobile and self propelled stabilizer / reclaimer of working width of 2.4 m and with minimum engine horse power of 440 kw with a variable working depth up to 50 cm. the resultant stabilized mix then would be profiled to the required grade, level and thickness using motor grader and the mix would be compacted using 20 tonne pad foot roller in combination with smooth wheel roller to achieve desired proctor density as per irc 37-2012 & 2018 and complete in all respect and curing with water as required including all materials, labour and machinery etc. the entire in-situ process would be carried out in single pass with milling and pulverising of damaged asphalt pavement / soil/ aggregates / soil-aggregate mixture to the desired depth and with simultaneous addition of additives and water with machine integrated spray bars fited on the wheeled self-propelled and vibratory pad foot roller to achieve the desired proctor density in all respects. the tandem roller be followed by pneumatic tyre roller. the minimum unconfined compressive strength (ucs) of stabilized sub base/ base should be 4.5 to 7 mpa after 7 / 28 days of curing as per irc-sp- 72-2015 , irc-37-2012 & 2018 . also durability aspects (wet-dry cycles) of stabilized sub base should be satisfied as per irc 37-2012 & 2018 and irc sp 89 (part ii) 2018. the gradation mixes and materials should be as per irc 37-2012 & 2018 and irc sp 89 (part ii) 2018. the train of equipments to be used are binder spreader- water tanker- additive truck- recycler- padfoot roller (20 tonne) + single drum compactor- grader- tandom roller- pneumatic tyreroller (20 tonne) 24 sami layerproviding and laying stress absorbing membrane interlayer (sami)/bitumen impregnated geotextile layer after clearing of the road surface geotextile conforming to physical requirements of claues 703-3, laid over a tack coat of paving grade bitumen 80- 100 penetration, laid at the rate of 1.05 kg per sqm over thoroughly cleaned and repaired surface to provide a water resistance membrane and crack retarding layer paving fabric to be free of wrinkling and folding and to be laid before cooling of tack coat, brooming and rolling of surface with pneumatic roller to maximise paving fabric contact with pavement surface. 25 providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 to 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. (tack coat on bituminous surfaces ) 26 providing and laying 40mmthickbitumencarpete(b.c.) with 100-120 tph hot mix plant producing and average output of 75 tonege par hour using crushed aggregates of specified grading premixed with bitumen binder(vg-30) @ 5.40% of mix as per most specification clause. etc all comp of work. 27 providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from aggregat aggregate natural sources, portland pozzolana/ordinary portland/portland slag cement, admixtures in recommended proportions as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads as per direction of the engineer-in-charge; for the following grades of concrete.note: extra cement up to 10% of the minimum specified cement content in design mix shall. be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 28 m.s. (tor steel or plain) in plain work such as rcc or rb work including binding for proper shape and including supply of steel and its wastage bend, hooks and authorized overlapping shall be measured and including cost of binding wire. excluding gst (sor-504). 29 [d] bill no. 4 - pedestrian infrastructure (footpath) 30 sand filling in foundation trenches as per drawing & technical specification and as per direction of engineer-in-charge. (including beneath all paver blocks, cobble areas for levelling purpose, etc.) 31 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. (pcc below all paving area, kerb channel, road edge kerb, table top, property edge beam) 32 construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at omc, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (by mix in place method) 33 i) for grading-i material 34 plain/reinforced cement concrete in open foundation complete as per drawing and technical specifications, pcc grade m30using batching plant transit mixer & manual placing(80 mm thickness) r & manual placingand giving broom finish. (pcc with broom finish thickness 80 mm) 35 providing and laying 75mm thick m-30 grade batch mix cement concrete and applying stamping finish to the top surface of freshly laid plain/ reinforced cement concrete of specified grade in porticos, sidewalks, driveways, pool decks and open yards as per direction of the engineer-in-charge. the process shall include the following:-the concrete shall be placed and screeded to the finished grade, and floated to a uniform surface by using standard finishing techniques. the approved color hardener @ 2.7 kg/sqm shall be applied evenly to the surface of the fresh concrete by the dry shake method by sprinkling in two or more shakes, floated after each shake and trowelled only after the final floating. the approved release agent @ 0.113 kg/sqm shall be applied evenly to the trowelled surface before stamping or the said release agent can be applied to the flexible polyurethane stamp moulds of approved design and in required sizes to achieve final stamped pattern. these stampings shall be placed on the surface of concrete in three to four pieces at a time and tapped gently with rammers of sufficient size & weight to leave proper stamp marks and the process repeated for the remaining concrete surface till the hole surface to be stamped is completed within the time while concrete is in plastic stage of setting.after stamping, the curing shall be done as per manufactures specifications. after initial curing the imprinted joints shall be grouted using cement slurry mixed with color hardener as per theequirement. the surface shall be sealed by applying acrylic based sealer not less than 0.167 litre/sqm.on finished surface.the construction joints shall be provided by groove cutting of size 4mm x 20mm in panel size 3m x 3 m or lesser as per the site conditions and filling the same with 10 mm baker rod and providing and laying (pu) polyurethane based joint sealer of approved make as per manufacturer’s specifications and finished by applying polyurethane resin based top protective clear coat of minimum 80 micron applied with rollers on properly cured and dry clean surface. (cost of concrete for flooring is not included in this item which shall be paid separately.) 36 80 mm thick c.c. paver block of m-35 grade with approved color design and pattern. 37 supply and fixing of tactile indicators made from ss-304 grade stainless steel. warning tactile indicator shall be installed on the walking surface in a raised grid pattern of dots or stud. minimum 36 studs to be placed in 300x300 mm area. dimensions - 35mm outer dia x25mm inner dia, stem dia 8mmx12mm, weight - 28grm.all the indicator will be installed into correctly drilled holes and place any suitable adhesive, all the indicators shall be aligned property, all complete as per direction of engineer-in-charge. 38 supply & fixing of tactile indicators made from ss-304 grade stainless steel. directorial tactile indicator shall be installed on walking surface, consisting of a series of raised bar/strip. min 4 bars/strip to be placed in direction perpendicular to distance of travel in 300x300 mm area. dimensions-280mm l x 35mm w x 4.5mm, stem dia 8mmx12mm, weight - 250grm all the indicator will be installed into correctly drilled holes and place any suitable adhesive, all the indicators shall be aligned property., all complete as per direction of engineer-in-charge. 39 providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to is : 15622 of approved make in all colors and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of engineer-in-charge 40 chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (dsr-11.20) 41 providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of engineer-in-charge. (saucer drain along the road edge, curved kerbs at property entry/exit, curved kerbs at side roads) 42 providing and laying at or near ground level factory made kerb stone of m-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment). (precast c.c. kerb stone shall be approved by engineer-in-charge). 43 cc grade m20 using batching plant transit mixer & manual placing all complete as per direction of e-i-c. 44 [e] bill no. 5 -parking 45 construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at omc, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (by mix in place method) 46 i) for grading-i material 47 supplying and filling in plinth with sand under floors/in trenches, including watering, ramming, consolidating and dressing all complete with material (from source to site), labor and t&p etc. required for proper completion of the work. (including royalty). 48 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days and giving broom finish. (pcc) 49 providing and laying factory made chamfered edge cement concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using pu mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of engineer-in-charge.80 mm thick c.c. paver block of m-35 grade with approved color design and pattern. 50 [f] bill no. 6 -cycle track 51 nil 52 [g] bill no. 7 - traffic signs, markings and other road appurtenances 53 providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow ms tube posts/horizontal members/bracings covered with 1.63mm thick ms sheet. the sheet shall be fixed with 30x5mm ms flat by suitable welding/riveting. the panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. ms channel islc 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long ms angle 40x40x6mm bracing. suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. the work shall be executed as per drawing/direction of engineer-in-charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the engineer-in-charge. the barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. the barricading shall not be removed without prior approval of engineer[1]in-charge.(note :- one time payment shall be made for providing barricading from start of work till completion of work i/c shifting. the barricading provided shall remain to be the property of the contractor on completion of the work). 54 reflective raised pavement markers (cat eye/ road stud) supply and fixing of raised pavement marker with made of plastic body of rpm/ road stud shall be moulded from asa (acrylic styrene acrylonitrile) or hips (high-impact polystyrene) or acrylonitrile butadiene styrene (abs) or any other suitable material approved by the engineer. the marker shall support a load of 13,635 kg tested in accordance with astm d4260. the reflective panels shall consist, of number of lenses containing single or dual prismatic cubes capable of providing total internal reflection of the light entering the lens face. lenses shall be moulded of methyl methacrylate conforming to astm d788 of equivalent. the slop or retro-reflecting surface shall preferably ba 5+/.5 degree lo base and the area of each retro -reflecting surface shall not be less than 13.00 $q.cm. the marker height shall not be less than 10 mm and shall not exceed 20 mm & width shall not exceed 130 mm the base of the marker shall be flat within 1.3 mm all road studs shall be legibly marked with the name trade or other means of identification of the manufacture. epoxy installations, excess adhesive around the edge of the marker, excess adhesive on the pavement and adhesive on the exposed surfaces of the markers shall be immediately removed. the contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel , to the engineer . in addition , a two year warranty for satisfactory infield performance of the finished road marker shall also be given by the contractor who carries out the work of fixing of reflective road markers. in case the markers are, displaced , damaged . get worn out or lose their reflectivity compared to stipulated standards , the contractor would be required to replace all such markers within 15 days of the intimation from the engineer , at his own cost. the rate shall include all materials, labor, t&p, transportation, installation and incidentals all complete as per direction of the engineer-in-charge, 55 rpm with shank 56 solar power road marker the solar studs shall be made of aluminum alloy and polycarbonate material which shall be absolutely weather resistant and strong enough to support to load of 13,635 kg tested in accordance with astm d4280. its color may be white, red, yellow, green or blue or combination as directed by the engineer. its water resistance shall meet the requirements of ip 65 in accordance with is: 12063:1987 category 2 for the protection against water ingress. the dimensions of solar studs shall not be less than 100 mm * 100 mm * 10 mm. it shall have super bright leds so as the provide long visibility from a distance of more than 800 m. its flashing rate shall not be less than 1 hz. its should be able to give the prescribed performance in the temperature range of -40 degree c to +55 degree c. its life shall be not less than 3 years. the rate shall include all material, labor, equipments, fabrication, transportation erection, installation and incidentals all complete as per direction of the engineer-in-charge 57 r.cc work (1:1.5:3) (m-20) with cement course sand &20mm the stone grit including all complete cement concrete with cement sand &20mm gauge stone grit with the proportion of (1:1.5:3)including all complete the work (morth ra-12.8 c, case-ii) 58 m.s. or iron work plain or tor for rcc work including cutting, bending, rivetting or welding etc. where necessary. excluding gst (s.i.no-504) 59 painting two coats on new concrete surfaces - painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces 60 m.s. or iron work of heavy sizes section such as trusses, built up gates, record racks, roof work, gates etc. including rivetting or welding where necessary. excluding gst (s.i.no-503) 61 painting of m.s. grill with enamul paint etc all complete work. (s.i. 15.15 new item no.) 62 providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, t&p, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of engineer-in-charge and accordance with applicable specifications. 63 providing and fixing of retro- reflectorized cautionary, mandatory and informatory sign as per irc :67 made of high intensity grade sheeting type-ivvide clause 801.3, 2mm thick aluminum sheeting, 1.5 mm thick supported on mild steel angle iron post 75mm* 75mm *6mm firmly fixed to the ground by means of properly designed foundation with m15 grade cement concrete 45cm* 45cm*60 cm, 60 cm below ground level as per the approved drawing. the retroreflective sheeting shall be tested for a certificate of having the sheeting coefficient of retro reflection, daytime, color and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoors weathering and its having passed these tests shall be obtained from international/ government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should be also obtained from indian condition within 3 years of launching ofproduct by the manufacturing abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirement from a reputed laboratory in india can be accepted provisionally. in such a situation , the employer/client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of 3 years outdoor weathering of the sheeting as per irc 67:2012 . legends, letters, numerals, and borders etc. should be as per mort&h specification 801.3.7. proof of the same in form of government reports shall be uploaded while quoting tender. 64 90 cm equilateral triangle with diffinitation plate size (20cm x 60 cm) 65 60 cm equilateral triangle with diffinitation plate size (20cm x 60 cm) 66 60 cm circular with diffinitation plate size (20cm x 60 cm) 67 80mm x 60mm rectangularwith diffinitation plate size (20cm x 60 cm) 68 60 mm x 45 mm rectangularwith diffinitationplate size (20cm x 60 cm) 69 60cm x 60cm square with diffinitation plate size (20cm x 60 cm) 70 90 cm high octagon 71 direction and place identification signs up to 0.90 sqm size board providing and erecting direction and place identification retro-reflectorized sign as per irc-67 made of high intensity grade sheeting the retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime color and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from international/government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally. in such a situation, the employer/ client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per irc 67:2012. legends, letters, numerals and borders etc. should be as per mort&h specification no-801.3.7. sheet fixed over aluminum sheeting 2 mm thick with area not exceeding 0.9 sqm. supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with m-15 grade cement concrete 45x45x60cm., below ground level as per approved drawing, complete. 72 direction and place identification signs with size more than 0.90 sqm size boardproviding and erecting direction and place identification retro-reflectorized sign as per irc-67 made of high intensity grade sheeting the retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime color and luminance, shrinkage, flexibility. liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from international/government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally. in such a situation, the employer/client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per irc 67:2012. legends, letters, numerals and borders etc. should be as per mort&h specification no-801.3.7. sheet fixed over aluminum sheeting 2 mm thick with area exceeding 0.9 sqm. supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with m-15 grade cement concrete 45x45x60 cm below ground level as per approved drawing, complete. 73 providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans & as per irc :67 74 brick masonry work in cement mortar 1:4 (1cement: 4 coarse sand) in foundation complete with cement concrete bricks procured from c&d waste recycling plant baswar excluding pointing and plastering, as per drawing and technical specifications. 75 struck pointing with cement mortar consisting of 1 part cement and 2 parts of fine sand of 1.25 finerness modulus.sor 2022 si no574 76 12 mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement :3 sand)and as per direction of engineer in charge. 77 finishing walls with ready mixed premium acrylic emulsion paint (company depot tinted) having volatile organic compound (voc)less than 50 gm/liter and uv resistance as per is 15489:2004, alkali, & fungal resistance, dirt resistance exterior paint of required shade with silicon additive(for painting wall, street furniture) new work (two or more coats applied @1.43 liter/10sqm over and including priming coat of exterior primer applied @ 0.90 liter/10 sqm) 78 supplying and fixing of cast iron antique style bench having weight of sides not less than 72 kg (36 kg each) fitted with fibre rectangle strip (should not be less than 50 mm x 25 mm and 1.6mm thick. length of bench should not be less than 6 ft (end to end of castiron support). 79 [h] bill no. 8 - utility and street light cabling 80 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.(pcc below pipe of storm water, sewer, water, inspection chamber for storm water, telecom chamber, power chamber and sewer) 81 providing and laying non pressure np-3 class (medium duty) r.c.c. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete (storm water, sewer) 82 600 mm dia rcc pipes 83 providing of 7- way 40mm multi ducts with solid permanently solidly lubricated silicone in inner layer for ict fiber cables conforming to astm f 2160, astm d 2444 and /or equivalent indian standard. external sheathshall be in orange colorand shall be free from visual defects like blisters, shrink holes,flaking, scratches, groove lines & surface roughness. the color of the 7 nos. plb hdpe ducts shall be green, blue, yellow, brown, violet, grey , red for differentiation. outer sheet thicknessshall be 1.2mm +/-0.2mm. the inner surface of the multi channel ducts shall be spirally ribbed & shall be of a configuration for faster installation of cables. wall thickness(mm) of each of the ducts excluding rib height shall be 2.9mm +/- 0.3mm. iso requirements- iso 9001, 14001, 18001, complete as per specifications and directions of engineer-in-charge. (7 way multi utility duct for ofc) 84 supply of hdpe pipe of size 110mm for distribution system conformingn to latest/ relevant i.s. 4984/1995 specifications with all jointing materials and specials conforming to latest /relevant i.s. specifications including f.o.r. destination and all taxes and insurance etc. with loading, unloading and carting up to site of work, also including specials for these pipes and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete (including testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches) all complete as per instructions of engineer-in-charge.110mm dia hdpe pipe pn-6 class pe-100 85 supply of hdpe pipe of size 63mm for distribution system conformingn to latest/ relevant i.s. 4984/1995 specifications with all jointing materials and specials conforming to latest /relevant i.s. specifications including f.o.r. destination and all taxes and insurance etc. with loading, unloading and carting up to site of work, also including specials for these pipes and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete (including testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches) all complete as per instructions of engineer-in-charge.63mm dia hdpe pipe pn-6 class pe-100 86 rcc grade m20 using batching plant transit mixer & manual placing ( side wall, bottom slab for all inspection chamber i.e. storm water, telecom, power, sewer, water) 87 supply and installation on site - recessed double seal ofwith a clear opening of750*750 mm di manhole cover and frame(material- ductile iron grade 500/7) of class b125 having minimum load capacity 125 kn load as per en124-2, the top cover( should have 2 no. of keyholes ) as per the design approved by engineer in chargedesign approved by engineer in charge. 88 supply and installation on site - recessed double seal ofwith a clear opening of750*750 mm di manhole cover and frame(material- ductile iron grade 500/7) of class d400 having minimum load capacity 400 kn load as per en124-2, the top cover( should have 2 no. of keyholes ) as per the design approved by engineer in chargedesign approved by engineer in charge. (storm water) 89 supply and fixing gully grates red 048 grh – 300* 750mm d.i. gully grate & frame in d400 load class , as per bs en 124 black bitumen paint, all complete as per direction of engineer-in-charge. 90 constructing rcc rectangular type manholewith a floating coat of neat cement, foundation concrete 1:6:12mix (1 cement : 6 coarse sand : 12 graded brick bats 40 mm nominal size), and making necessary channel in cement concrete of m-25 grade finished with a floating coat of neat cement, all complete as per standard design and instruction of e-i-c. 91 restoration of water pipeline in case of damage 92 [i] bill no. 9 - horticulture / landscaping works 93 trenching in ordinary soil up to required depth including removal and stacking of serviceable materials and then disposing of as directed and spreading earth & neatly levelling, breaking clods etc. and making the trenched area with designed mounds, paths and sitting spaces etc. to proper levels by filling with earth or earth mixed with manure and properly watering complete work in required topography as per drawing & specifications. 94 supplying and stacking of good earth at site including royalty but including carriage1km (earth measusred in stacks will be reduced by 20% for payment). 95 supplying and stacking at site dump manure from approved source,including carriage up to 1 km (manure measured in stacks will be reduced by8% for payment) 96 mixing earth and manure in specified proportion or as directed. 97 rough dressing the trenched ground including breaking the clods. 98 fine dressing the ground 99 spreading ofmixed good earth and manure in specified proportions as above and in required thickness. 100 uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation. 101 providing & laying selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge 102 preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of officer-in-charge. 103 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete. 104 providing and stacking of nauclea cadamba (kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge. 105 providing and stacking of nyctanthes arbor-tristis (hasingar) of ht. 90-105 cm in earthen pots of size 20 cm as per direction of the officer-in-charge. 106 providing and stacking of terminalia arjuna of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. 107 providing and stacking of plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size hdpe bags as per direction of the officer-in-charge. 108 providing and stacking of plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size hdpe bags as per direction of the officer-in-charge. 109 providing and stacking of ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. 110 providing and stacking of ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.. 111 providing and stacking of duranta golden, having ht.15 to 20 cm bushtyshape with fresh and healthy leaves in 15 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge.. 112 providing and stacking of tradescantia zebrina having in 15 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge. 113 providing and stacking of wedelia trilobata,full of leaves in 15 cm size ofpoly bags & as per direction of the officer-in-charge. 114 providing and stacking of asparagus sprengeri of height 30 cm to 45 cm, full of leafy branches in 15 cm size of earthen pot / plastic pot & as per direction of the officer-in-charge.. 115 providing and stacking of ophiopogon jaburan ( variegated ), full of variegated leaves in earthen pot/plastic pot of size 20 cm. as per direction of the officer-in-charge. 116 providing and displaying of croton petra bangalore variety having ht. 60 cm to 75 cm with 4 to 6 branches, well developed, fresh and healthy colorful leaves in 25 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge. 117 providing and fixing ms iron tree guard 60 cm dia and 2 metre high above ground level formed of 4 nos (25 x 6 mm) and 8 nos (25 x 3 mm) vertical ms riveted to 3 nos (25 x 6 mm) iron rings in two halves, bolted together with 8 mm dia and 30 mm long bolts including painting two coats with paint of approved brand over a coat of priming, complete in all respects. 118 street light works (excluding gst) 119 supply & fixing of 9 mtr gi octagonal pole of approved make (top dia 70mm, bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 mtr length) on rcc foundation including the cost of foundation, foundation bolts, excavation & back filling and required t&p complete in all respect 120 supply and fixing of led street light fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 watt. confirming to ip 66 protection complete in all respect. cat: aaa 121 supply and laying of 16 sq.mm. 4 core aluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer-incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 122 supplying and laying 6 swg g.i. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with gi thimble etc. as required. 123 supply and burring of safe earthing electrode t-39 (hot-dip galvanized), length up to 3000mm, outer pipe 76mm inner dia38mm terminal dia 12 mm ,outer gipipe of 16 swg and inner gi pipe of 12 swg withhot dip galvanization up to 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. frame with hinged cover & masonary housing. (from electrode terminal to switch board, cost of 25 x 3 gi. strip will be extra) make: as approved in u.p. p.w.d., & c.p.r.i. certified. 124 making connection of each street light by s/l 1.5 sqmm frlsh copper wire complete as per direction of engineer in charge. 125 supply & fixing of 9 mtr gi octagonal pole of approved make (top dia 70mm, bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with double arm bracket (1 mtr length each ) on rcc foundationincluding the cost of foundation, foundation bolts, excavation & back filling and required t&p completee in all respect. 126 supply & laying of 63 mm dia (od-63 mm & id- 51 mm nominal) dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers, etc. conforming to is 14930, part ii complete with fitting and cutting, jointing, etc. direct in ground (75 cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc, complete as required. 127 supply and fixing for automatic street light cubical control juction box painted with anti-corrosive alkali and acid proof pait consisting of 6 amps mcb (b - curve) complete in all respect 128 supply and fixing of 16 sq.mm plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer-incharge. 129 supply and fixing of 40 amp. capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors, hrc fuses, isolating switch metering instrument & instrument box with cts etc. in case of tpn, complete in all respect. 130 supply and laying of 32 mm x 6 mm g.i. strip from earth electrode directly in the ground as required complete in all respect. 131 supply/ erection of surface mounted decorative pole 4500 mm long having base plate 300x300x12 mm with the bottom dia 139 mm upto 1 mtr long with the thickness of 3.6 mm and the top dia is 76 mm upto 3.5 mtr. log. decorative pole made out of galvanized iron tube with cast aluminium embellishments. the poles are painted with polyturetnane paint. the pole have service window at the bottom on the pole for housing the mcb and terminal strips and as per attached drawings. 132 s/f of single arm decorative bracket 100 mm long made of cast iron/ aluminium embellishments painted with polyturetnane paint. 133 supply of led decorative drop down light made of aluminium housing fitted with polycarbonate diffuser having 500 mm dia with 70 w. 134 supplyandlayingof aluminiumconductorpvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer-incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core 135 supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors, hrc fuses, isolating switch metering instrument & instrument box with cts etc. in case of tpn, complete in all respect. 40 a tpn 136 supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer-incharge. 16 sq. mm 137 supply & laying of 63 mm dia (od-63 mm & id- 51 mm nominal) dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers, etc. conforming to is 14930, part ii complete with fitting and cutting, jointing, etc. direct in ground (75 cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc, complete as required. 138 supply and laying 6 swg g.i. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with gi thimble etc. as required. 139 supply and burring of safe earthing electrode t-39 (hot-dip galvanized), length up to 3000mm, outer pipe 76mm inner dia38mm terminal dia 12 mm ,outer gipipe of 16 swg and inner gi pipe of 12 swg withhot dip galvanization up to 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. frame with hinged cover & masonary housing. (from electrode terminal to switch board, cost of 25 x 3 gi. strip will be extra) make: as approved in u.p. p.w.d., & c.p.r.i. certified. 140 part - b utility shifting (including gst) 141 converstion of lt overhead line by underground lt line 142 lt xlpe insulated cable of size 3.5x400 sqmm. 143 lt xlpe insulated cable of size 3.5x240 sqmm. 144 lt xlpe insulated cable of size 3.5x150 sqmm. 145 lt xlpe insulated cable of size 3.5x70 sqmm. 146 9 mtr long stp 147 hdpe pipe 140mm dia peb0, pn-6 148 hdpe pipe 120 mm dia peb0, pn-6 149 hdpe pipe 75 mm dia p880, pn-6 150 aluminium crimping lugs 400sqmm 151 aluminium crimping lugs 240sqmm 152 aluminium crimping lugs 150sqmm 153 aluminium crimping lugs 70sqmm 154 6 swg g.l. wire for earthing along cables. 155 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x400 sqmm. lt cable 156 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x240 sqmm. lt cable 157 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x150 sqmm. lt cable 158 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x70 sqmm. lt cable 159 main lt panel at sub station- 400 kva (type a-2)lncomer- 1 set of 800 amp. tp mccb with spreader & extended handlemetering on lncomer - 1 set of digital ammeter with ass- 1 set of digatal voltmeter with vss- 1 set of led type phase lndicating light (22.5 mm.)with control mcbsoutgoing- 6 set of 250 amp. tp mccb with spreader & extended handte( 5 nos. + 1 no. for capacitor panel)- 2 set of 100 amp. tp mccb with spreader & extended handle 160 main lt panel at sub statton- 250 kva (type a-2) lncomer- 1 no. 630 amp. tp mdo acb with inbuilt mpr release with i ontoff tnai.ating lightmetering on lncomer - 1 set of digital ammeter with ass- i set oldigital volt-meler wirh vss- 1 set of led type phase indicating light (22.5 mm.j with control mcbs outgoing - 5 set of 250 amp. tp mccb with spreader & exrended handle- 2 set of 100 amp. tp mccb with spreader & extended handle flnstallation oflt distribution boards for lt underground system (type a,b&cj) 161 supply , installation, testing & commissioning of outdoor type feeder pillar panetto be made of 2 mm crca sheet and covers will be j.6mm crca sheet dulypowder coated paint with 300 amps al. busbar. (type-b2)lncomer - 250 amp. tp mccb - 1 no.outgoing - 63 amp. tp mccb - 5 nos.lnstallation of lt distribution boards forlt underground system (type-a, b & c) 162 outdoor type feeder pillar panel to be made of 2 mm crca sheet and covers will be 1.6mm crca sheet duly powder coated paint with 300 amps al. busbar. [type-b3] incomer - 100 amp. tp mccb - 1 no. outgoing - 63 amp. tp mccb - 4 nos.lnstallation of lt distribution boards for lt qnderground system [tvpe-a, b & cl 163 lockable distribution boxes of size 450x400mm with bus bar 100 amp. tpn to feed upto 10 houses (type c) 164 xlpe lt service armoured cable for single phase,2x6 sq. mm.(pvc armoured consumer service cablel 165 xlpe lt service armoured cable for single phase,2x10 sq. mm.(pvc armoured consumer service cablej 166 xlpe lt service armoured cable for three phase,4x10 sq. mm.[pvc armoured consumer service cablel 167 xlpe lt service armoured cable for three phase,4x1.6 sq. mm.(pvc armoured consumer service cablel 168 xlpe lt service armoured cable for three phase,4x25 sq. mm.(pvc armou[ed consumer service cable) 169 pvc pipe 32 mm dia 170 pvc pipe 50 mm dia 171 electronic kwh meter 1px2w with box. for single phase consumer 172 electronic kwh meter 3px4w static meter with box.for three phase consumer 173 carriage , laying of 3.5cx400 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 140 mm dia. 174 carriage, laying of 3.5cx150/240 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 1.20 mm dia. 175 carriage ,laying of 3.5cx70 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 75mm dia. 176 painting of stp incuding paints [2 ltr red oxide and 2 ltr alluminum paint for each pole.l 177 grouting of st pole 178 cartage , erection and dismentling charges 22% of materials cost 179 conversion of 11kv overhead/underground line by 11kv line underground 180 11 kv cable size 3x185 sq.mm xlpe 181 stp 11m-is 410 sp-55 182 g.l pipe 4 dia 183 top channel 100x50x2240 mm 184 hdpe pipe 160 mm dia pe 80, pn-6 185 service clamp o/s 186 clamp for fixing pipe to pole 187 11 kv cable jointing kit size 3x185 sq.mm xlpe o/d 188 11 kv cable jointing kit size 3x185 sq.mm xlpe s/t 189 earthing complete. 190 m.s. nut & bolt with washer 191 bracing angle 65x65x6x2700 mm with clamp 192 stone pad 193 number plates with clamp 194 danger board & clamp with bolts & nuts 195 stay complete 196 g i barbed wire 197 carriage , layrng of 3x185 sq.mm size 11 kv xlpe insulated cable underground in hdpe pipe dia 160 mm. 198 painting of stp incuding paints (2 itr red oxide and z lt. allrn inrm pal,1t for each pole.) 199 grouting of st pole 200 grouting of stay set 201 cartage , erection and dismentling charges 22% of materials cost 202 conversion of 33kv overhead/ underground line by 33kv line underground 203 cable al. 3x300 sq.mm. xlpe 33 kv 204 stp 11m-is 410 sp-55 205 g.l pipe 6 dia 206 m.s.top channel 100x50x2240 mm 207 hdpe pipe 200 mm dia pe 80, pn-6 208 service clamp o/s 209 clamp for fixing pipe to pole 210 bracing angle 65x65x6x4300 mm with clamp 211 33 kv cable jointing kit 3x300 se mm outdoor 212 33 kv cable jointing kit 3x300 se mm straight through 213 earthing of pole by ms earthing rod of 2ox25o0 mm & 6 swg earthr.ng wire etc. 214 m.s. nut & bolt with washer 215 number plates with clamp 216 danger board & clamp with bolts & nuts 217 stay complete (stay rod 15x1800mm, stay wire 5 kg,, stay clamp, boult & nut rvith grouting 218 daner bqard barbed wire includin jumpering 219 carriage , layrng of 3x300 sq.mm size 33 kv xlpe insulated cable underground in hdpe pipe dia 200 mm. 220 painting of stp incuding paints (2 itr red oxide and z lt. allrn inrm pal,1t for each pole.) 221 grouting of st pole 222 grouting of stay set 223 cartage , erection and dismentling charges 22% of materials cost 224 installation of 250 kva transformer on dp for the shifting of 3 no. 250 kva. 9 no.400 kva & 3 no. 630 kva transformer 225 stp 11m-is 410 sp-55 226 ms channel 100x50x2240 mm 227 service clamp for round pole 228 m.s. bolt and nuts off size with washer 229 l.t. cable 3.5ox4oo so m 230 ltxlpe insulated,unarmoured aluminium singlc corc cable,1x240sq. mm.sizc 231 lt xlpe insulatcd,unarmoured aluminium singlc core cablc,1x400 sq. mm.size 232 earthing of 250 kva t/f with g.i. pip[ 233 earthing rod complet. 234 1 1 kv d.o. fi]se sets 235 1 1 kv tpmo 236 d.d. wire 70 qs mm 237 250 kva t/f 238 l.t. cubical b0x complete 239 l,t. cable 3.50x240 sq mm 240 stay set complete, 241 aluminimum lug 70 sqmm 242 aluminimum lug 240 sqmm 243 aluminimum lug 400 sqmm 244 pvc tape 245 t/f bushing connector of copper strip 246 labour , cartage & errection charges and dismentaling of existing t/f 247 dismentling and cartage from site to store charges 7% (other misclenous charges)
  • View Tender
  • Document
  • Bid Support
  • 1
  • 2
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : terminal building
  • Workshop Tenders ,
  • Hutment Tenders ,
  • Construction Shop Tenders ,
  • Guard Post Tenders ,
  • Portable Cabin Tenders ,
  • Rain Basera Tenders ,
  • Fire House Tenders ,
  • Telephone Exchange Building Tenders ,
  • Loading Docks Tenders ,
  • Security Post Tenders

Get terminal building Tender Alert...

317061

Related Searched Keywords : terminal building

  • Tubewell Tenders From Maharashtra
  • Excavation Tenders From Delhi
  • Bridge Tenders From West-Bengal
  • Lake Development Tenders From -Tamil-Nadu
  • Demolition Work Tenders From Andhra-Pradesh
  • Earth Works Tenders From Gujarat
  • Flood Gate Tenders From Karnataka
  • Wall Work Tenders From Uttar-Pradesh
  • Grouting Work Tenders From Rajasthan
  • Rcc Dam Tenders From Madhya-Pradesh

Read More


Tender Document

424561

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Zone Work Tenders
  • Soil Work Tenders
  • Plastering Tenders
  • End Wall Tenders
  • Buildings Repair Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App