Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Sewage Removal
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of sewage-removal Tenders

List of latest sewage-removal Tenders in Indian Tenders. Click on any sewage-removal Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for sewage-removal Tenders.

Advance Search
  • All-Tenders (10)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
1 Security Services
image image
Central Government/Public Sector
TRN :49054084 |  10 Jun, 2025
Tender Value : 28.00 Crore
 Abohar - Punjab
Tender for tender for provision of deficient married accommodation at fazilka mil stn (job no: - mwp/swc-02/2024-25); 1 lump sum price worked out by the tenderer for“building /structure works as listed in schedule ‘a’ section - i 2 sch a section- ii, internal electrification works and flame proof fittings 3 material and labour for concealed point wiring for one light point/fan point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 20mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm (1:3)including fixing ofswitch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of boq as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). 4 -do- all as per srl no. 3 above but one three pin switch socket outlet 5 amps on the same borad 5 -do- all as per srl no. 3 above but one call bell controlled by one bell switch 6 -do- all as per srl no. 3 above but wiring with 2.5 sqmm multistranded cable and earth wire with copper conductor of size 2,5 sqmm for 5 amps point (on independent board) 7 material and labour for concealed point wiring for one socket outlet 15/20 amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 25mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm(1:3), including fixing ofswitch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of boq as supply only but cost of moudlar cover plate with frame and labour for fixing the same shall deemed to be included in the unit rate). 8 supply only modular switch 6amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 9 supply only modular switch 16amps,piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 10 supply only modularsocket outlet 2 in 1, 6amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 11 supply only modularsocket outlet 5 in 1, 16amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 12 supply and fixing ceiling rose, polycarbonate, isolated body, surface bakelite 2 to 3 terminal, 240 volts, 5/6 amp, isi marked complete all as specified and as directed by engineer-in-charge. 13 supply and fixingelectric calling bell ding dong type, ac 230 volts single pole including making elctric connection complete all as specified and as directed by engr-in-charge. 14 supply only modular bell push switch, piano flush type, 6amps, single pole, one way (1 module) fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) complete all as specified and as directed by engineer-in-charge. 15 supply and hanging /fixing ceiling fan 1200 mm sweep ac supply (input voltage range ; 120 to280v), bldc type, 5 star rated, bee and isi marked super enamelled, copper winding of b class insulation, single phase, maximum 30w (± 10%), temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 no blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified and as directed by engr-in-charge.note :- (i) serial number as issued by engr-in-charge of celing fan and ge office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account 16 supply and fixing exhaust fan (heavy duty) steel body, ac single phase 230v, 50hz, 900rpm, size 300mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core pvc insulated pvc sheathed copper conductor flexible cable 24/0.2mm drawn in flexible pvc conduit and hanging on wall with 4 nos steel fastners 12mm dia 200mm long and making good the disturbed surface complete all as specified and as directed by engineer-in-charge.note :- (i) serial number as issued by engr-in-charge of fan and ge office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) cost for making suitable cutting/opening in wall for fixing of exhaust fan including making good disturbed surface and masonary work shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. 17 supply and fixed for spn 8 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 18 supply and fixed for spn 6 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 19 supply and fixed for spn 4 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 20 supply and fixed for tpn distribution board 4 way vertical type double door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper bus bar suitable rating with neutral bar and earth bar and cable tie for cable management, ip-54 protection and provision and including mccb 4 pole 160 amp, 16 ka as incomer and mcbs as outgoing, dust and vermin proof complete all as specified and as directed by engineer-in-charge. 21 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, c curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 22 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 40 amps complete all as specified and as directed by engineer-in-charge. 23 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 24 supply and fixing blanking plate of plastic suitable for any type of db complete all as specified and as directed by engineer-in-charge. 25 material and labour for submain wiring comprising single core, 2 runs of 4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 20mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 26 material and labour for submain wiring comprising single core, 2 runs of 6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 27 material and labour for submain wiring comprising single core, 2 runs of 10.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 28 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing wire of size 4 mm dia by means of gi bolts/nuts/washers and protected by 15 mm bore gi light grade pipe upto test point or upto main switch board, ht/lt equipments, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 29 supply and fixing led tube light fitting polycarbonate housing 1 x 18/20watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g) aluminium housing & integrated electronic driver(h)led driver of the same make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection minimum 2.5 kv. (l) cct : minimum 6500k(m) cri : more than 80 (n) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 30 supply and fixing led tube light fitting polycarbonate housing 1 x 10watt, appx 2 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g)led driver of the same make as of the luminaire.(h) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(j) surge protection minimum 2.5 kv. (k) cct : minimum 6500k(l) cri : more than 80 (m) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 31 supply and fixing led lamp 1x9 watt including pvc holder with complete suitable for fixation on wall/roof with body robust corrosion resistant, superior flnish and without any cracks of through holes complete all as specified and directed by engineer-in-charge 32 supply and fixing energy efficient led security light fitting of 35w pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street/roadway luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of gi tubing medium grade 32mm dia, 1.2 metre long bent to shape at 32 degree angle at half metre from bottom, including two nos clamps made out of ms flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to ms clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts (c) temp operating range : minus 10°c to plus 50°c (d) power factor : minimum 0.95(e) thd : max10%.(f) ip rating : ip66. (g) ik rating:minimum ik07 (h) built in potted led driver of the make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection 10 kv (inbuilt + extended) (l) cct : 5700 k. (m) cri: more than 80 (n) lens - high efficiency wide angle lens. (o) bis approved fixtures and driver (p) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 33 rigid non metallic pvc conduit 20mm dia (external) for sub main/telephone wiring inclusive of all fittings such as tees, bends, elbow, reducers, junction boxes bell mouth tube ends and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc complete all as specified and as directed by engineer-in-charge. 34 material and labour for mild steel boxflush mounted of size 100mm x100mmx100mm having holes for 20 mm conduit entry including 02 pin tv socket outlet flush type marked with symbol of tv and 03 mm thick plastic laminated sheeet cover and making good disturbed surfaces of walls by using cm (1:3)complete all as specified and as directed by engineer-in-charge 35 supply, installing, commissioning and testing of electric water heater (geyser) storage type abs body of capacity 25 litres, bee approved 5 star rating, 230 v , single phase, ac supply, inner tank made out of heavy duty stainless steel sheet (designed with single weld line, factory tested with hydraulic pressure as per latest is code) with glass lined coating complete with all accessories such as safety valve, thermostate, nrv, connection piece pvc connection 600mm long heavy duty suitable for hot and cold water, three core pvc insulated pvc sheathed copper conductor flexible cable, 04 nos suitable size mild steel l-hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by engr-in-charge. 36 supply and fixing for led light fitting 1x9w/1x10wbulkhead luminaires including led light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 37 supply and fixing earth continuity conductor or main earthing lead 32x6mm galvanised iron strip including nuts bolts and washer fixed to wall with saddles and fixing screws or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including making good disturbed surface complete all as specified and as directed.note :- (i) conduit/pipe as required, same shall be measured & paid separately under respective item of this sch/boq. 38 subtotal 39 lump sum price worked out by the tenderer for“internal water supply works as listed in schedule ‘a’ section - iii (part-i) 40 sch a sec - iii (part-ii), internal water supply works 41 supply and fixing two way bib cock/angle stop valve with flange, cast copper alloy chromium plated, screwed down high pressure with on/off handle screwed ends suitable for 15 mm bore pipe iron pipe or for brass ferrule/unions and fixed complete all as specified and as directed. 42 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 16 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 43 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 20 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 44 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 25 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 45 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 40 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 46 supply and fixing single lever concealed diverter incl bath spout & shower complete all as specified and as directed by engineer-in-charge. 47 supply and fixing for brass chromium plated aquaguard/ro inlet valve or diverted valve with nozzle compatible for all type of water purifier fixing to steel pipe of socket of 15mm bore complete all as specified and as directed by engineer-in-charge. 48 supply and fixing for 40mm bore cpvc long handle vavle complete all as specified and as directed by engineer-in-charge. 49 supply and fixing health faucet fancy type, cp including 1.25 meter long 8mm dia flexible tube and including wall hook and fixing material complete all as specified and as directed by engineer-in-charge. 50 subtotal 51 lump sum price worked out by the tenderer for“road, pcc tiles andhume pipe culvert works) as listed in schedule ‘a’ section -iv (part-i) 52 sch a sec - iv (part-ii), road, pcc tiles andhume pipe culvert works 53 material and labour for premix bituminous concrete 40mm consolidated thicknesswith min 5.4 % binder content (bitumen of grade vg-30)by weight of total mix using sensor paver electronic sensing device for automatic leveling and profile control withi the specified toleranceand internal heating arrangement for the screed all as specified in table 500-17 of morth specification for road and bridge works 2013, rolled and compacted to required camber and gradient with tandem vibratory roller 8 to 12 tonne power roller to a uniform smooth surface complete all as specified and as directed by engineer-in-charge. 54 material and labour for thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads @ 8% by weight including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed by engineer-in-charge 55 supply and laying/fixing 80mm thick factory made chamfered edge cement concrete paver block of m-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 56 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 57 material and labour for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. 58 subtotal 59 lump sum price worked out by the tenderer for“(area drainageworks) as listed in schedule ‘a’ section -v 60 lump sum price worked out by the tenderer for“sewage disposal works as listed in schedule ‘a’ section - vi (part-i) 61 sch a sec - vi (part-ii), sewage disposal works 62 supply and laying dwcpe (sn8) drain pipes 180 (od)/163(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch 63 supply and laying dwcpe (sn8) drain pipes 200 (od)/175(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch. 64 subtotal 65 lump sum price worked out by the tenderer for“security fencing and gate works as listed in schedule ‘a’ section - vii 66 lump sum price worked out by the tenderer for “external water supply works as listed in schedule ‘a’ section-viii (part-i) 67 sch a sec - viii (part-ii),external water supply works 68 supplying, laying, jointing and testing ductileiron pipe (isi marked) class k-7, bore 150mm, confirming to is : 8329-2k, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (push-on joint) complete all as specified and as directed by engineer-in-charge.note : (i)earth work, di specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) test certificate for pipes from manufacturer shall be produced. no payment shall be entertained without test certificate. 69 supply and fixing cast iron sluice valve 150 mm dia with flanged ends class pn 1.6(heavy duty isi marked) confirming to is:14846-2000, drilled type, complete with stainless steel spindle, ci gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by engineer-in-charge. 70 material and labour for construction of brick masonary valve pit chamber size 90 x90 x90 cm (internal dimension) using sub class b bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, pcc (1:3:6) type c-2 using 40 mm graded stone aggregate in foundation, coping on top in pcc (1:2:4) type b-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, ms sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer and embeded portion of ms work duly applying black bitumenous paint before embeded complete all as specified and as directed by engineer-in-charge. 71 subtotal 72 lump sum price worked out by the tenderer for“external electrification and lightning protection works as listed in schedule ‘a’ section - ix (part-i) 73 sch a sec - ix (part-ii), external electrification and lightning protection works 74 supply and fixing lightning arresters ht 11000 v non linear expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, confirming to is 3070 (part-i) 1985 complete all as specified and as directed by engineer-in-charge. 75 supply, installing, commissioning & testing energy efficient transformer suitable for 315 kva (level-2) step down floor mounted outdoor type 11/0.433kv, 3 phase, 50 hz ac, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on hv side and star connected on lv side in accordance with vector symbol dyn-11 (vector group 4) with neutral brought out on lv side with for earthing and having tapping on hv side for constant output so as to alter/vary secondary voltage (tapping range + 5 %to - 10% in equal step of 2.5 % ) changed by means of manually operated off load taps changing gear. the voltage regulation shall be as per is including first fill of transformer oil as per is-335 and including all fittings/accessories. the limit of temperature rise after continuous full load run as specified in is-1180 (part-i) 2014 and bee certified shall be suitably adjusted to suit the maximum ambient temperature of 55 degree centigrade as prevalent complete all as specified and as directed and shall be comprised with the following fittings and accessories :- 76 (a) oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge. (b) silica gel breather with connecting pipe, first fill of dehydrating agent. (c) explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (d) air release valve plug (e) one cable box on lv side (secondary) consisting of 04 nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joints complete all as specified (f) explosive vent (g) 01 no 100 mm dial type thermometer vapor pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc. (h) thermometer pocket on tank cover (j) 04 nos plain solid ci detachable rollers (k) two nos earthing terminals marking plate. (l) rating plate and terminal marking plate(m) extra bushing for neutral outside the cable box brought out on lv side. (n) first filling of oil conforming to is and tested upto 60 kv dielectric strength (o) lifting lugs (p) oil drain valve with plug (q) one cable box on hv side (primary) consisting of 01 cable gland suitable for reception of taking in ht cable including gland joints complete all as specified (r) hand hole of sufficient size to assess interior of tank (s) dehydrating breather with first filling of dehydrating agent (t) two earthing terminal on tank body to facilitate fixing of 32x6mm gi strip. (u) rating plate with terminal marking plate (v) inspection cover. 77 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 78 (a) copper bus bar of 800 amp capacity, 4 strip mounted on porcelain insulators. (b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 500 amp (incomming).(c) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 25 ka, 125 amp - 07 (for 07 blocks).(d)mcb tpn 32 amps -01 nos (for street lights).(e) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(f) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (g) ryb led indicating lamp set of three -01. 79 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 80 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 32 amp - 16 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 81 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 82 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 16 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 20 amp - 07 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-100amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 83 supply and fixing cable junction box of size 280mm x 200mm x100mm or any other higher size (suitable for pole mounting) complete with fixing accessories. junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. the polycarbonate junction box shall be environment frinedly, recyclable, uv resistant, halogen and silicon free, anti acid and anti corrosive. the junction box knock out on four side wall and following specifications and all as directed by engr-in-charge :-(a) the junction box shall be rated for degree ofip 65 (ingress protection) in accordance with iec 60529.(b) the gasket material shall be polyurethane or silicon and gasket shall be internally embedded.(c) junction box must meet the provision laid down in iec 60998-1, iec-60695-22, iec 60670-2 to 5 and grey color according to ral-9011/ 7035.(d) the manufacturer of junction box shall submit a copy of iec certificate and glow wire test for 960 degree.(e)junction box shall be fire retardant and self extiguishing in accordance with iec60695-2 to 11, din vde 0304 part-3, ul94 v-2 flammability standard. (f) the impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with en 50298-98 for ik08.(g) junction box shall have 4 pole tinned copper bus bar of size 25mmx3mm complete with one number 20amp mcb sp 10ka (h) manufacturer should submit routine test certificate for junction box. (j) suitable size of mild steel clamps and screws/nut bolt shall be used for fixing of junction box.. 84 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing strip 32x6mm by means of gi bolts/nuts/washers and protected by 40 mm bore gi light grade pipe upto 7.5 mtr length, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing strip upto 7.5 mtr from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 85 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 86 s&f for gi steel light grade 32 mm dia bent to shape of offset angle upto 45 degree for fixing of security light fitting gi pipe 1.5 mtrs including ms clamp and nut bolts complete all as specified and as directed by engr-in-charge. 87 subtotal 88 sch a sec - x, fire fighting eqpt works 89 supply and fixing fire hydrant landing valve type a (double head outlet) gunmetal of 65 mm dia with 63 mm dia female outlet complete and 65 mm inlet with rubber blank cap and chain as per is 5290-1983, suitable for brigade hose of 63 mm with couplings conforming to is 903 (for internal hydrant at ground floor to 3rd floor and roof) complete all as specified and as directed. 90 supply, installing, commissioning and testing of fire hose cabinet to be mounted externally near the hydrant post fabricated from 16 swg mssteel of appox size 800 mm x 600 mm x 450 mm with a canopy, door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accommodate one hydrant valve, one branch nozzle and 30 mtrs hose reel, weather proof, finished with and including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer ( sample to be approved prior to entire supply) complete all as specified and as directed. 91 supply, installing, commissioning and testingof wall mounting swinging type first aid firehose reel with drum, hanging bracket, 30 mtr long and20mm dia high pressure hose reel as per is 444 with gunmetal shut off nozzle having 5mm dia orifice. the hose reel shall be conforming to is 884-1985. drum shall be fixed on adjoining wall through anchor fasteners/cement concrete book or ms stand as per site requirement complete all as specified and as directed. 92 supply, installing, commissioning and testing of 63mm dia gun metal, short type, instantaneous pattern branch pipe to suit fire hose delivery coupling of 63 mm size complete with gm nozzle of 20 mm nominal size conforming to is 8090 complete all as specified and as directed. 93 supply, installing, commissioning and testing of gun metal body butterfly valves of size 63mm dia, is:210, pn-16, confirming to is:13095 complete all as specified and as directed. 94 supply, installing, commissioning and testing of booster pump 30 m head, 450lpm discharge, 440 v, 3 phase, 50hz confirming to is- 12469 :1988 with ci casing bronze impeller and stainless steel shaft mounted on heavy duty bearings complete all as specified and as directed. 95 supply, installing, commissioning and testing 65mm nominal bore, wall thickness 6mm, ms heavy duty (c class) flanged pipe, isi marked (is : 1239) with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer complete all as specified and as directed. 96 supply and fixing trolley mounted water stored pressure type fire extinguishers, 9 ltr capacity conforming to is:13386 with extinguishing agent :water+afff and propelling nitrogen gas, wall bracket handle fitted with high pressure flexible discharge hose with discharge throw of 2-5 mtrs.,with isi certification markcomplete all as specified and as directed. 97 supply and fixing carbon-di-oxide 3 kgs capacity fire extinguisher (light weight squeeze grip type) fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn, and cylinder bearing no., confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 98 supply and fixing dry chemical powder fire extinguisher ( abc powder ) 9 kgs capacity stored pressure type, ce mark valve with nrv & safety release provision with epdm rubber hose, the extinguisher is internally coated with epoxy polyester and externally coated with pure polyester powder and confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 99 supply and fixing mechanical foam extinguisher of 9 ltr capacity and confirming to is:15683:2006 complete all as specified and as directed. 100 supply and fixing fire buckets (dry sand)of 7 kg capacity including hanging arrangements complete all as specified and as directed. 101 supply and fixing emergency exit sign board with double side adhesive tape vinyl sticker with forex board (green and white colour) 30 cm x 10 cm complete all as specified and directed. 102 subtotal 103 lump sum price worked out by the tenderer for“lift works as listed in schedule ‘a’ section - xi (part-i) 104 sch a sec - xi (part-ii), (lift works) 105 supply, installing, commissioning and testing 13 passenger lift, having 1.0 m/s car speed, gearless motor suitable for 3- ph, 415 v, 50 hz electric power supply, conforming to is-14665, suitable to serve g + 3 upper floors with ac variable voltage & variable frequency drive (vvvf drive), complete with all standard accessories, simplex full collective operation, centre opening doors with door drive, sliding stainless steel doors, automatic rescue device (ard) system, 2d infrared sensor in full height of door & built in press and speak 3 way intercom. complete all as specified and as directed and shall conform to the following specifications: 106 type of lift : passenger lift 107 capacity of lift : 884 kg, 13 person 108 rise : up to g+3 bldg 109 stop and opening - 04 stops with all opening on the same side 110 controller type : microprocessor based 111 drive : ac vvvf drive 112 power supply : 400/415 volts (3 phase ac) 113 operation : full collective operation 114 car group : simplex type 115 machine : gearless motor located above shaft in machine room 116 traction media : steel rope 117 car finish : rear mid panel, rear corner panel, side mid panels, side corner panels, front panels all are made of stainless steel ss304 with honey comb finish 118 false ceiling finish : stainless steel with hairline finish and with provision for led lights specified here-in-after. 119 ventilation : pvc heavy duty cross flow fans 120 hand rails : stainless steel finish round handrails on rear car panels 121 flooring :20mm thick granite to be provided in the recess car cabin floor and fixing with suitable adhesive over aluminium chequered plate in one piece minimum 3mm thick. 122 car door and landing door finish : stainless steel ss-304, mirror finish outside 123 fire rated doors : fire rating - 60 minutes 124 pit depth: 1600 125 overhead : 4500 126 hoistway dimensions(w x d – mm) : 2500 mm w x 1900 mm d 127 car size (w x d x h - mm) : as per is-14665 (part 3 sec-i) : 2000, height 2200 mm 128 car & hoistway door type : central opening (co) doors 129 door opening (w x h - mm) : 900 mm w x 2000 mm h 130 door operator : vf 131 cop : cop (car operating panel) and lop (landing operating panel) in stainless steel hairline finish with display. 132 car position indicator : dot matrix type 133 hall fixtures : dot matrix type 134 hall fixture face plate : stainless steel hairline finish-ss-304 135 hall button arrangement: hall and call buttons with illumination and braille 136 car and counter weight guide as per oem recommendation 137 terminal buffers metal spring/oil buffer as per oem recommendation 138 standard features :anti-nuisance car call protection, independent service, overload device, nudging, emergency car light unit, infrared curtain door protection, door time protection, emergency alarm button, extra door time of lobby & parking door open/close button, manual rescue operation, auto fan cut off, over speed governor for car 139 also included : emergency firemen’s service, automatic rescue operation, intercom. 140 car enclosure: manufactured with stainless steel frame not less than 1.5mm with honey combfinish (ss-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with led sleek light fittings (as per manufacturer’s instructions, minimum 04 nos) operated on commercial supply and one led light fitting operated on battery with inverter as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection 141 floor announcement system in car cabin 142 signals: (a) combined luminous hall buttons with led hall position indicators at all floors (b) led car position indicator panel of stainless steel (c) car operating panel of stainless steel with luminous buttons in car (d) car direction indicator in car & landing (e) battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (the system shall be separate from ard batteries.) (f) overload warning feature in car cabin (display / announcing type both) (g) one firemans switch to be installed at ground floor near landing door. (h) all signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (j) infrared door sensor safety edge of door for entire height. 143 safety device: (a) automatic rescue device (ard) / automatic landing device operating with maintenance-free batteries having suitable capacity. the batteries must have auto charging facilities. (b) the ard actuation time shall be less than one second after failure of power supply and when ard is operative the car shall stop at the nearest floor and then doors shall open. 144 operation: simplex, full collective automatic operation 145 machine room: located above the hoist way, details as per building drawings 146 hoist way: construction details as per building drawings 147 civil work: necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. 148 one number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. the telephone instrument shall be connected in the telephone db installed in the machine room 149 looking mirror of size 1200x900mm, 5.5mm thick to be provided on rear panel wall (opposite to main door) of car cabin above hand rail 150 provision of suitable size of copper conductor xlpe insulated cable from lift panel installed at ground floor to machine room will deemed to be included the rate quoted by the contractor 151 subtotal 152 lump sum price worked out by the tenderer for“excavation, earthwork and site development works as listed in schedule ‘a’ section - xii 153 schedule a section -xiii (furniture works) 154 almirah small steel as per drawing no. fd-1032 sheet no. 1/1 155 book shelf open (large) steel as per drawing no. fd-69(m) sheet no. 1/1 156 bed hard as per drawing no. fd/e6/map/08(r) sheet no. 1/1 157 chair verandah as per drawing no. fd/e6/map/11 sheet no. 1/1 158 charpoy folding ip with hard top as per drawing no. fd-388(r) sheet no 1/1 159 peg table as per drawing no. fd/map/11 sheet no. 1/1 160 rack shoe steel as per drawing no. fd/e6/map/02(r) sheet no. 1/1 161 table bed side as per drawing no. fd/e6/map/15(r) sheet no. 1/1 162 table centre as per drawing no. fd/map/08 sheet no. 1/1 163 dressing table including stool as per drawing no. fd/map-ii/07 sheet nos 1/2 & 2/2 164 chair dining jcos/ors as per drawing no. fd/map-ii/05 sheet no. 1/1 165 chair easy per drawing no. fd-229 sheet no. 1/1 166 chair writing as per drawing no. fd-280 sheet no. 1/1 167 charpoy with hard top as per drawing no. fd/map-ii/01 sheet no. 1/1 168 mirror dressing(gents) as per drawing no. fd/e6/map/16 sheet no. 1/1 169 table dining 4 persons as per drawing no. fd/map-ii/03 sheet no. 1/1 170 table with drawer (900 mm x 600 mm x 760 mm) as per drawing no. fd-283 sheet no. 1/1 171 chair school with hand board as per drawing no. fd/e6/map/05 sheet no. 1/1 172 note:-quantities of materials given on standard drawings are for guidance only. the contractor shall work out the quantities of materials required for each item of boq and quote his rate accordingly no claim shall be entertained on account of inaccuracy in the quantities of these materials and workman ship which shall be as specified in particular specifications and as approved. the drawing nos mentioned in boq item no 184 to 264 shall form part of tender document which will not be attached with tender document. the tenderers are deemed to be in possession and conversant fully with the drawing shown in standard furniture designs including amendments published by ahq, engineer-in -chief, new delhi. for reference and guidance the tenderer may study and see these drawings in the any office ofgarrison engineer in mes before quoting their rates. no claim shall be entertained regarding misinterpretation of the drawings at a later stage. 173 subtotal 174 lump sum price worked out by the tenderer for“arboriculture works as listed in schedule ‘a’ section - xiv (part-i) 175 schedule a section -xiv (part-ii) (arboriculture works) 176 material and labour for grassing with selection no.1 grass including enough watering and maintance of the lawn till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed including supplying and spreading of neem oil cakes, manure or sludge and chemical required for preparation of the ground for plantation of grass complete all as specified and as directed. 177 supply and planting of hedge and shrubbery (anarmi, ficus and the like) as directed by engineer-in-charge minimum 3 feet above gl including creation of beds by excavating 60 cm deep and 60 cm wide trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio 8:1 (8 part of stacked volume of earth after reduction of 20 % with 1 part of stacked volume of sludge or manure ater reduction by 8%) flooding with water filling with earth if necessary, watering and finally fine dressing leveling etc including stacking and disposal of material declared unserviceable and surplus earth by spreading and leveling as directed within a lead 50 m and lift upto 1.50 m complete all as specified and as directed. 178 supply and laying/fixing 60mm thick factory made chamfered edge cement concrete paver block of m-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 179 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 180 supply and laying factory made kerb stone of size 30x15x45cm of m-25 grade cement concrete laid in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement:3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed by engineer-in-charge 181 supplying following plants in poly bags 0.25 m to 0.30m dia with height 1.20 m to 1.80 m including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 2:1(2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludgeor manure after reduction by 8%) flooding with water and removal of surplus soil, with & including antitermite treatment using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 182 neem tree. 183 canerydate palm 184 gulmohar 185 fruit bearing trees 186 plumeria 187 supplying plants flower like ticoma, rose,motia, chandni, lxora, marigold rose, vinca (any colour) as directed of height not less than 0.60m above gl including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 3:1(one part of manure & 3 part of soil) manure 200 gm per plant ,flooding with water and removal of surplus soil n.exc 1.50 km and depositing where directed with & including using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 188 supply and fixing precast rcc 1:1.5:3 type a1 lawn bench and backsupport of size 1.50 x 0.60m of maximum three person seating capacity supporting precast rcc type a1 for back and base with including assemble the precast member with suitable nutt & bolt and placing and anchoring with hold fast 350mm - 16mm dia ms bar on concrete base (size 1.20x0.60m for each support) with 100mm thick pcc 1:2:4 type b1 over 150mm thick sub base pcc 1:4:8 type d2 complete all as specified and as directed by engineer-in charge 189 subtotal 190 schedule a section -xv ( maintance) 191 material and labour for the plants/hedge/grass by weeding, hosing, saucer making once in every month for plants/hedge, once in every 15 days for carpet grass/country grass/doob grass, bermuda grass, pruning dired ranches once in every week, depositing the material at place of dead plants of same species and height turning with dods whenever required by replacing the dead patches of grass of any type with same grass as required without any extra cost to the department all as specified and as directed. (plants of various species -678 nos (approx), hedge and shruery - 520 rm (approx) and grass - 4000 sqm( approx) 192 subtotal
  • View Tender
  • Document
  • Bid Support
2 Banking And Mutual Funds And Leasings
image image
Central Government/Public Sector
TRN :49057750 |  30 May, 2025
Tender Value : 0
 Kolkata - West Bengal
Tender for tender for providing house keeping services on contractual basis at ground floor’s: 1 conference hall, 2 hall classrooms(1 cbotc, 1 cld), 6 offices(principal office, admin office, cld office, cld comp lab, ssb, guest faculty room, 4 washrooms (ladies & gents separate), 3 store room/electric room corridor & passage first floor’s:- 4 classrooms 1 computer lab 8 offices(6 faculty rooms,1 ups, 1 it officer) 1 library 2 wash rooms(ladies & gents separate) corridors, passage & two set of stair case for ground floor to first floor. dusting, sweeping, mopping, cleaning and wiping of floors, furniture, fixtures, partitions, walls, ceiling, curtains, venation blinds, removal of wastes from dustbin and keeping it properly as directed, removal of cob-webs, dusting and wiping the windows and their glass pane, doors and polishing their handles, cleaning of telephone instruments, fax machines, computers, spraying disinfectant, room freshener, cleaning all drains/sewage pipes including removing blockages in drain/sewage pipes, removal of garbage and waste papers on daily basis from the premises. daily first shift (02 workers) between 0800 hrs to 1600hrs second shift (02 workers) 1000 hrs to 1800 hrs 2 washing and scrubbing the floor of the entire office premises with soap water and drying it by using the machines/tools for floor polishing/ cleaning. weekly on saturdays 3 ground floor’s: 4 washrooms (ladies & gents separate), first floor’s:- 2 wash rooms(ladies & gents separate) dusting, sweeping, mopping, cleaning, polishing, wiping and removal of cow-webs, wastes, dusting and wiping windows, glass pain, china clay sanitary fittings, mirrors and doors, polishing door handles, metal sanitary fittings, washing and cleaning and wiping the wall tiles and floor with soap / harpic / colin / acid and providing urinal phenyl cubes and liquid soap as per requiremen
  • View Tender
  • Document
  • Bid Support
3 Telecommunication Services And Equipments
image image
Central Government And Public Sector
TRN :49059263 |  17 May, 2025
Tender Value : 14.93 Lacs
 Howrah - West Bengal
Tender for tender for structural strengthening and external painting of b e college t e howrah; 1 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2 nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 3 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 4 of area 3 sq. metres and below 5 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 6 for thickness of tiles 10 mm to 25 mm 7 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 8 up to 150 mm diameter 9 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 10 disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 11 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 12 1:2:4 (1 cement : 2 coarse sand(zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 13 reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 14 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 15 reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). 16 reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii)derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources). 17 centering and shuttering including strutting, propping etc. and removal of form for : 18 foundations, footings, bases of columns, etc. for mass concrete 19 columns, pillars, piers, abutments, posts and struts 20 vertical and horizontal fins individually or forming box louvers band, facias and eaves boards 21 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 22 smooth finishing of the exposed surface of r.c.c. work with 6 mm thick cement mortar 1:3 (1 cement : 3 fine sand). 23 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 24 providing and fixing fiber glass reinforced plastic (frp) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. the laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiber glass from all sides. m.s. stay shall be provided at the bottom to steady the frame. 25 providing and fixing to existing door frames. 26 30 mm thick glass fibre reinforced plastic (frp) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick frp laminate for panels conforming to is: 14856, including fixing to frames. 27 steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 28 in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 29 providing and laying rectified glazed ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to is : 15622, of approved make, in colours white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4(1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 30 providing and fixing on wall face unplasticised - pvc moulded fittings/accessories for unplasticised rigid pvc rain water pipes conforming to is 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 31 single tee with door -110x110x110 mm 32 bend 87.5° -110 mm bend 33 15 mm cement plaster on the rough side of single or half brick wall of mix : 34 1:6 (1 cement: 6 fine sand) 35 finishing walls with acrylic smooth exterior paint of required shade : 36 new work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 37 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 38 two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 39 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 40 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 41 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°c, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 350/300 n/5 cm. tear strength in longitudinal and transverse direction as 60/80n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 42 3 mm thick 43 providing and fixing white vitreous china pedestal type (european type/ wash down type) water closet pan. 44 providing and fixing p.v.c. low level flushing cistern with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete. 45 10 litre capacity - white 46 providing and fixing solid plastic seat with lid for pedestal type w.c. pan complete : 47 white solid plastic seat with lid 48 providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 49 providing and fixing p.v.c. waste pipe for sink or wash basin including p.v.c. waste fittings complete. 50 flexible pipe -32 mm dia 51 providing and fixing ptmt bib cock of approved quality and colour. 52 15mm nominal bore, 86 mm long. weighing not less than 88 gms. 53 providing and fixing ptmt stop cock of approved quality and colour. 54 15 mm nominal bore, 86 mm long. weighing not less than 88 gms. 55 providing and fixing ptmt pillar cock of approved quality and colour . 56 15mm nominal bore, 107 mm long. weighing not less than 110 gms. 57 providing and fixing unplasticised p.v.c. connection pipe with ptmt nuts, collar and bush of approved quality and colour. 58 15 mm nominal bore with 45 cm length. 59 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 60 75 mm average thickness 61 50 mm average thickness 62 25 mm average thickness 63 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 64 bars upto 12 mm diameter 65 bars above 12 mm diameter 66 providing, mixing and applying bonding coat of approved adhesive on chipped portion of rcc as per specifications and direction of engineer-in-charge complete in all respect. 67 sbr polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer 68 providing, mixing and applying sbr polymer (of approved make) modified cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of engineer-in-charge. note: measurement and payment: the pre-measurement of thickness shall be done just after the surface preparation is completed and payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 n/sqmm2). 69 12 mm average thickness. 70 25 mm average thickness in 2 layers. 71 50 mm average thickness in 3 layers. 72 providing and fixing upvc pipes (sch 40 upvc as per astm d- 1785 pipes) including all upvc plain and brass threaded fittings. including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step upvc solvent cement and testing of joints complete as per direction of engineer in charge. internal work- exposed on wall 73 15 mm nominal bore 74 20 mm nominal bore 75 25 mm nominal bore 76 uprooting and removing small plants from the surface of walls, parapet, etc. at any height by cutting chase for removing roots and using necessary chemicals etc. to prevent further growth of plants and mending good damages complete. 77 a) small plant of girth of exposed stem up to 75mm 78 providing and fixing soil waste and vent pipes : 79 110 mm dia upvc soil waste pipe conforming to is:13592 1992 (type-b) manufactured by supreme industries limited or equivalent. 80 erection of single layer bamboo-scaffolding made of average 75 mm dia bamboos with adequate bracing, ties, ropes etc. for strong, stable and workable scaffolding for specified jobs ( above gf beyound 4.00m height) like replacement of sewage/ rw pipes & accessories, repairs to plasters, special repairs, replacement of glass panes, uprooting/ cutting of tree saplings etc including dismantling the scaffolding after the job is done and clearing the site complete as per the direction of the engineer-in-charge. [ projected area of scaffolding frame work on buiding elevation to be measured for payment] 81 felling of trees like banyan, pipul etc from compound walls, building walls, cornices etc by making scaffolding where necessary including cutting of trunks and branches, application of chemicals/weedicides to the remaining portion to kill the growth of tree and ultimately removing the roots from the walls by cutting walls and mending good complete. ( the rate is inclusive of the mending good the walls with bricks/concretes/plasters and disposing of branches/trunks to vats inside compound for further disposal) 82 a) of girth above 30 cm upto 60 cm (measured above 1.0 m from gl toupto 5.0 m height) 83 extra for shifting of existing scaffolding by lifting/dragging or partially dismantling and re-erecting the dismantled portion in position (shifting at least 1.50 m from initial centre line of position) over payment for initial erection & dismantling paid in original item of scaffolding. [ projected area of scaffolding frame work on buiding elevation to be measured for payment] 84 providing and fixing ptmt health faucet with hook and p.v.c. pipe (1.00 metre minm length) of approved quality and colour in w.c.s all complete as per direction of engineer-in-charge. 85 15 mm nominal bore with minimum 1.00 m pvc tube. 86 attending repairs to ms gate by removing corroded portion of gate with welding machine at site and replacing with new members as per actual requirement at site. (cost for labour and hire charges of welding machine including transporation, consumables. steel members will be paid separately) 87 providing and welding 2mm thick m.s. sheet to existing m.s. frame work including providing and appying a priming coat of approved steel primer all complete. 88 providing and fixing upvc floor trap 100mm dia inlet and 100 mm dia outlet. 89 providing and fixing ptmt 2 way bib cock of approved quality and colour, for fixing hand faucet in commode toilets all complete as per direction in charge.- 15mm nominal bore. 90 supplying, fitting and fixing in position fibre glass panes of approved quality with resin, nail, clip etc. as per is:12866-1989. 91 4.0 mm thick (6.72 kg/sq.m) 92 credit value for dismantled unserviceable mild steel/ iron materials. 93 credit value for dismantled g.i. pipes: 94 15 mm nominal dia. 95 20 mm nominal dia. 96 25 mm nominal dia. 97 credit value for dismnatled c.i./ s.c.i. pipes. 98 credit value for unserviciable brass bib/stop cocks/pillar tap
  • View Tender
  • Document
  • Bid Support
4 Construction
image image
State Government
TRN :49020265 |  13 May, 2025
Tender Value : 17.34 Lacs
 Delhi - Delhi
Tender for e.i.u.s. (revenue) providing and laying cc pavement over existing deteriorated cc pavements and raising of drains in jj cluster a - block, jahangirpuri (pid-16722).- 1 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge.nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 2 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge.nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 3 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. in cement mortar 4 desilting of nallah / drain in running flow and under foul condition for depth not exceeding 1.50 metre . including removal of stones , brickbats, garbage, silt mud, polythene , sewage if any etc. and diversion of flow of sludge if required and removing the same away from cluster at the place as directrd by engineer-in-charge. disposed silt to be levelled and neatly dressed. 5 earth work in excavation by mechanicalmeans (hydraulic excavator)/manual means in foundation trenches or drains (not on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil a directed, within a lead of 50 m. all kinds of soil. 6 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-iii) : 4 graded stone aggregate 20 mm nominal size). 7 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-iii): 10 graded stone aggregate 40 mm nominal size). 8 providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of r.m.c. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per is : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the engineer-in-charge.” note : excess/less cement used than specified in this item is payable/ recoverable separately all works upto plinth level : m-15 grade plain cement concrete (cement content considered @ 240 kg/cum) 9 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: cement mortar 1:4(1 cement : 4 coarse sand) 10 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand) 11 12 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) 12 neat cement punning. 13 providing and fixing factory made precast rcc perforated drain covers, having concrete of strength not less than m-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional t.m.t. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with m.s. flats of size 50 mm x 1.6 mm complete, all as per direction of engineerin- charge. 14 providing and fixing non a.c. multipurpose fiber cement board strips in joints of cement concrete pavements. 50mm+- 5mm wide and 6mm thick having normal length not less than 90cm. 15 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-iii): 10 graded stone aggregate 40mm nominal) manufactured sand derived from recycled concrete aggregate (rca): 10 graded stone aggregate 40 mm nominal size). 16 providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering. all work upto plinth level. 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including manufacture sand derived from recycled concrete aggregate (rca) upto 25% 4 graded stone aggregate 20mm nominal size including recycled concrete aggregate (rca) upto 25% 17 providing and laying dry brick aggregate 40mm nominal size in foundation and plinth or under floors at all level including spreading and ramming in layers as directed by engineer-in-charge 18 suply of earth and banking the same in layer not exceeding 20 cm indepth braking clods watering rollieach layr with 182 tonne roller of wooden or steel rammer including dressing up in embankment for rods, foloods banks, guide banks or filling of ground depressions with all lead and lift etc. complete. 19 add for cost index @35.22 %as per order by gnctd. except item no.15 and 16 (i.e. on 3987.30+6608.75 = rs.10596.05) 20 deduct 9.50% as per gnctd
  • View Tender
  • Document
  • Bid Support
5 Housing Urban And Rular Development
image image
Local Bodies
TRN :49022842 |  16 May, 2025
Tender Value : 8.07 Lacs
 Raebareli - Uttar Pradesh
Tender for tender for construction work of 04 m.m.i.g. buildings in amol vihar yojna - earth workinfoundation in ordinary soil ( loamclay,or sand) including lift upto 1.5 metre ( 5fts) and lead upto 30m. (100fts.)andincludingfilling watering and raming of excavatedearthintotheplinth and removal anddisposalof surplus earth and directedby the engineer - in - chargeupto a distance of 30m. ( 100 fts ) from the foundation trenches. 2 earth work in cutting or in embankment in ordinary soil, excavation to be in form of regularpitsnotexceeding1/2 mt (20) in depth and earthwork inembankmenttobein20cm (8) layers, including ramming anddressingthesurfaceto requiredlevelsandslopesand alsoincluding1.5mts(5fts)lifts and 30mt (100fts) lead. the earth from cutting to be used in makingembankmentsortobe deposited as spoil banks with in30mts(100fts)distanceas directedbytheengineerin charge,includingcartageof8km. 3 concrete with4cm. (1*1/2) gauge brick ballast, fine local sand of 1.25 fineness modulous andcementin proportion of 8: 4:1infoundationsand under floors, includingsupply of allmaterials,labourand t&p etc.requiredforpropercompletion of the work. 4 providingandlayinginposition specified grade of reinforced cement concrete, excluding cost of centering, shuttering, finishing and reinforcement in 1: 11/2 : 3 ( 1 cement, 11/2 coarse sand , 3 20mm graded stone aggregate. 5 foundations,footings,basesof columns, etc. for massconcrete 6 columns,pillars,piers,abutments, posts and struts 7 suspended floors, roofs, landings, balconies and accessplatform 8 mildsteelorironinplain worksuchasreinforced concreteorreinforced,brick work(when notincluded inan over all rates ) wroughtto required shapeasnecessary includingbendingforproper completion of the work and including supply of steel its wastagebendhooksand authorised over lapping shallbemeasured. 9 brick work in comman burnt clay (non-modular)bricks of class 150 in super structure aboveplinthlevelincluding supplyoflabour,materialand t&prequiredforproper completionofworkincement mortar 1:6 ( 1 cement: 6 coarsesand) 10 class150 brick work in1:4 cementand coarsesand mortarinsuper - structureforwallthickness 12 cms 11 12mmthickcementplasterof mix1:4(1cement:4coarsesand) 12 providing &layingof lightcinderfillingunderfloorof toilets & other sunken roofs. 13 providingandfixinginwall unplasticisedrigidpvcrain waterpipesconformingtois: 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermalexpansion,(i)singlesocketed pipes. 110 mm dia 14 providingwoodworkinframe ofdoors,windows,celerestory windowsandotherframes, wrought frames and fixed in positionwithholdfastlugsor withdashfastnersofrequired dia and lenghts (hold fast lugs or dashfastnersshallbepaidforseperately): sal wood 15 providingandfixingangleiron framesfordoors,windowsand ventilatorsofmildsteelangle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing t- ironframeortothewallwith dash fastener, including fixing of necessary butt hinges and screwsandapplyingapriming coatofapprovedsteelprimer, all complete as per the direction ofengineer-in-charge.(fordoorframes) 16 providingandfixingisimarked flush door shutter confirming to is:2202(part1)non-decorative type, core of blockboard constructionwithframeoffirst classhardwood andwell matched commercial 3 ply veneering with vertical grains or cross bands and face vineers on both facesof shutters:35mm thick including isi marked stainlesssteelbutthingeswithnecessary screws. 17 providingandfixingwiregauge shutterusinggalvanisedms wiregaugeofaveragewidthof apurture1.4mminboth directionwithwireofdia 0.63mm for doors, windows and celestorywindowswithhinges and necessary screws. 35mm thick shutter, with isi marked mspressedbutthingesbright finished of required size withsecond class teak wood. 18 steelworkweldedinbuiltup sections/framedwork, including cutting, hoisting, fixing inpositionandapplyinga primingcoatofapprovedsteel primer using structural steel etc. asrequired.ingratings,frames, guard bar, ladder, railings, brackets,gatesandsimilarworks(forwindow grills) 19 providingandfixingaluminium towerbolts,isimarked, anodised (anodic coating not lessthangradeac10asper is:1868) transperent ordyed to required colour or shed, withnecessary screws etc. complete. 150 x 10mm+ 20 250 x 10 21 providingandfixingaluminium sliding door bolts, isi marked anodised anodic coating not less thangradeac10asperis: 1868),transparentordyedto requiredcolourorshade,with nutsandscrewsetc.complete:250x16 mm 22 providingandfixingaluminium hangingfloordoorstopper,isi markedanodised(anodic coatingnotlessthangradeac-10asperis:1868)transparent ordyedtorequiredcolourand shed, with necessary screws etccomplete. twin rubber stopper. 23 mildsteelorironwork of heavy sizes and sections such as holdingdownbolts,holdfast, tie, rods gratings etc (when not included in an over all rates) wrought to required form, includingsupplyofsteel,bolts, nutsandwastageetcandtheir fixingrequiredtoproper completionofwork.(fortubular stair case railing) 24 providingandlayingvitrified floortilesindifferentsizes (thickness to be specified by the manufacturer) with water absorptionlessthan0.08%and conforming to is : 15622, of approved make, in allcolours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarsesand),includinggrouting the joints with white cement and matching pigmentsetc.,complete. size of tile 600x600 mm 25 providingand laying vitrified tilesin differentsizes (thickness tobespecifiedby manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in allcolours &shade,inskirting,riserof steps,over12mmthickbedof cement mortar 1:3 (1 cement: 3 coarsesand),includinggrouting thejointwithwhitecement& matching pigments etc.complete. size (600x600) 26 marblestoneflooringwith18 mmthickmarblestone,asper sampleofmarbleapprovedby engineer-in-charge, over 20 mm (average)thickbaseofcement mortar 1:4 (1 cement : 4 coarse sand) laid and jointedwith grey cement slurry, including rubbingand polishing complete with : udaipur green marble 27 providingandfixingfirstquality ceramic glazed wall tile confirmingtois:15622 (thickness to be specified by the manufacturer)ofapproved makeinallcolours,sheds exceptburgandy,bottlegreen, black of any size as approved by engineerincharge,inskirting, rizersofstepanddados,over 12mmthickbedofcement mortar1:3(1cement:3coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mix with pigment ofmatching shed complete. 28 providing and laying ceramic glazed floor tiles of size 300x300 mm(thicknesstobespecified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours suchaswhite,ivory,grey, fume red brown, laid on 20 mm thickcementmortar1:4(1 cement : 4 coarse sand), includingpointingthejoints with white cement and matchingpigment etc, complete. 29 providing and applying white cementbasedputtyofaverage thickness1mm,ofapproved brand and manufacturer, over the plastered wall surface to prepare the surface even andsmooth complete. 30 finishing walls with acrylic smoothexteriorpaintof required shade on new work (twoormorecoatapplied@1.67ltr/10sqmoverand includingprimingcoatof exterior primer applied @ 2.20kg/ 10 sqm) 31 wallpaintingwithacrylic emulsionpaint,havingvoc (volatile organic compound ) content less than 50 grams/ litre, of approved brand and manufacture,includingapplying additional coats wherever required, to achieve even shadeand colour. two coats 32 paintingwithsyntheticenamel paint of approved brand and manufactureofrequiredcolour togiveanevenshade:twoor morecoatsonnewworkover an undercoatofsuitable shade with ordinary paint of approvedbrand and manufacture 33 providing and fixing white vitreouschinapedestaltype water closet (european type) withseatandlid,10litrelow level white vitreous china flushingcistern&c.p. flush bend with fittings & c.i.brackets,40 mm flush bend, overflow arrangement with specials of standard make and mosquito proofcouplingofapproved municipaldesigncomplete, including painting of fittings and brackets, cutting and making good thewallsandfloorswherever required : w.c. pan with isi markedwhitesolid plastic seat and lid 34 providingandfixingwashbasin withc.i.brackets,15mmc.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making goodthewallswhereverrequire: whitevitreouschinawash basin size 630x450 mm with a pairof15mmc.p.brasspillartaps 35 providing and fixing p.v.c. waste pipe for sink or wash basin including p.v.c. waste fittingscomplete. semi rigid pipe 32 mm dia 36 providing and fixing cp brass bibcock of approved quality confirming to is: 8931 15mm nominal bore. 37 s/f of 15mm nominal bore cpvc pipe all complete. 38 providing and fixing cp brass angle valve for basin mixer and geyser points of approved quality confirming to is:8931 15mm nominal bore. 39 15mm nominal boare 40 providing and fixing cp brass shower mixer of 15 or 20mm bore including cp brass connection with angle valve of standard design and approved make confirming to is:8931 41 providing and fixing cp brassover head shower with 15 or 20 mm inlet including connection complete: 100mm diameter. 42 providing and fixing trap of selfcleansing design with screwed down or hinged grating with or with out vent arm complete, including cost of cutting chases and making good the walls and floors:100mm inlet and 100mm out let pvc 43 100mm inlet and 75mm outlet pvc 44 providing and placing on terrace (at all floor levels) polyethylene water storage tank, isi : 12701 marked, with cover and suitable locking arrangement andmaking necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 45 providing, fixing and jointing pvc pipes of different diameters with with pvc solvent cement (or as per manufacturers specifications) with or without sockets (if sockets are provided with pipe length) in vertical sewage line, waste water line and vent line with all necessary bends, angle bends, tees, elbows ms bat clamps along with all necessary fastners and bolt with cutting chases and making good the walls and floors wherever required including testing of the same all as per direction and satisfaction of engineer in charge.6kg per sqin pressure pipe75mm inner dia. 46 6kg per sqin pressure pipe110mm inner dia. 47 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot and cold water supply, including all cpvc plain and brass threaded fittings, including fixing the pipe with clamps 1.00m spacing. this includes jointing the pipes and fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 15mm nominal outer dia pipes. 48 25mm nominal outer dia pipes. 49 constructing masonary chamber 30x30x50cminside,inbrick workincementmortar1:4(1 cement:4coarsesand),with ci surface box 100x100x75 mm(inside)withhingecover fixed in cement concrete slab 1:2:4 ( 1 cement : 2 coarse sand:4 graded stone aggregate 20mm nominal size) including necessary excavation, foundationconcrete1:5:10(1cement:5finesand:10graded stoneaggregate40mmnominal size)andinsideplasteringwith cement mortar1:3 ( 1 cement : 3coarsesand)12mmthick, finishedwithafloatingcoatof neat cement complete as perstandard design: 50 supply delivery errection the fabricatedmsboardofsuitable sizeonwhichthefollowing supplieditemsshallbefixedas per the direction of enggincharge. 51 (a)supply and fixing 63 ampdoublepole(singlephase &neutral)240voltresidual currentcircuitbreakerrccb havingasensivitycurrentup to300 ma on the existing ms board complete with connection testing&commissioningetcas required. 52 (b)supplying & fixing 2+8way single door prewired sp&n mcb distribution board of sheet steel for240voltonexistingms board complete with dpmcb isolator40amp240volt1no& 25amp single pole240 volt spmcb(c)series5nos completeduly wired with 4sqmm fr pvc insulated copper conductorupto terminal box tinned copper busbar ditachable gland plate, inter connection phosphotized &powder coated includingearthingetcasreq( for power distribution ) 53 (c)supplying & fixing 2+8way single door prewired sp&n mcb distribution board of sheet steel for240voltonexistingms board complete with dpmcb isolator40amp240volt1no& 10amp single pole240 volt spmcb(c)series5nos completeduly wired with 4sqmm fr pvc insulated copper conductorupto terminal box tinned copper busbar ditachable gland plate, inter connection phosphotized &powder coated includingearthingetcasreq( for light distribution ) 54 wiring point for lightwith 1.5sq mmfrpvcinsulated multistrandsinglecorecopper conductorcableinpvcconduit concealedinthewallcomplete with modulartype switch &ceilingrose/angle/batten holderon3mmthickphenolic laminated backalite sheet etc comp in all respect 55 wiringpointforfan 1.5sq mmfrpvcinsulated multistrandsinglecorecopper conductorcableinpvcconduit concealedinthewallcomplete with modulartype switch &ceiling roseon3mmthick phenolic laminated backalite sheet &fan boxetccompin all respect 56 wiringpointfor freshairfan with 1.5sq mmfrpvc insulated multistrandsinglecorecopper conductorcableinpvcconduit concealedinthewallcomplete with modulartype switch &ceiling roseon3mmthick phenolic laminated backalite sheetetc comp in all respect 57 supply&fixing5ampmodular switch & 5amp 5pin modular socketontheexistingmodular plateandswitchboxincluding connection etc as reqd. 58 supply&fixingofpowerplug 20amp250voltflushtype modular switch& 5pin 20amp 250voltmodular socket on concealedmsbox etc.asrequered 59 supply & wiring for power pointwith2no4sqmmfrpvc insulated1100voltgrade multistrandsinglecorecopper conductor cable in 20mm dia heavydutypvcconduitwith1 no2.5sqmmfrpvcinsulated multistrandcopperconductor cable as earth continuity wire in conduit etc as required 60 wiringofcircuitalongwith earth wire with the following size of fr pvc insutated copper conductorsinglecorecablein recessed medium class 20mm dia pvc conduit as required 61 1x1.5sqmm+1x1.5sqmm 62 supply & fixing of electronic fan regulatormodular400w 120v-- 280v isi marked on existing switchboard includingmaking connection etc for proper completion of work 63 supply&burryingofsafe earthingelectrodet-19zn-zinc coated,lengthupto3000mm, outer pipe 48.4mmx3.2mm, inner pipe 26.9mmx2.6mm, terminaldia12mm,coating80- 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc)capable of reducingthe soilresistivitywith good mixture of retaining capacityandoneearthinglead of 20mmx3mmg.i. strip,up to switch board (from apron to switchboard,thecostofg.i. strip will be extra)along with 30cm square c.i. frame with hinged cover & masonary housing 64 supplying&layingof 20mmx3mm g.i. strip directly in ground&onwallasrequired complete in all respect (from apron to switch board. 65 wiring for submain withthe 2x10sqmm size fr pvc insulated copper conductor cable in recessedmediumclasspvcconduit as required 66 boring with hydraulic piling rigs with power units, providing and installingcastinsitusingleunder reamedpilesofspecifieddiameter andlengthbelowpilecapinm-25 cementconcrete,tocarryasafe working load not less than specified, excluding the cost of steel reinforcement but including thecostofboringwithbentonite solutionandthelengthofthepile to be embedded in pile cap etc. all complete.(lengthofpilefor payment shall be measured upto tothe bottom of pile cap) : 300 mm dia piles 67 s/f of kitchen sink including all labour and t&p all complete. 68 15mm thick plaster in 1:4 (1 cement and 4 coarse sand) including all labour complete. 69 s/f of gate valve including all labour and t&p all complete 70 s/f pvc bulb holder including all labour and t&p all complete 71 s/f aluminium door handle including all labour and t&p all complete 72 s/f of chequered tiles on ramp of house including all labour and t&p all complete 73 s/f flange bib cock with z spray including all labour and t&p all complete 74 s/f of kota stone on rear court yard anf front porch of house including all labour and t&p all complete 75 s/f of granite stone on kitchen top of house including all labour and t&p all complete 76 s/f of basin mixture including all labour and t&p all complete 77 s/f of 25mm cpvc pipe including all labour and t&p all complete
  • View Tender
  • Document
  • Bid Support
6 Construction
image image
Corporations/Associations/Others
TRN :34441768 |  12 May, 2025
Tender Value : 20.00 Crore
 Bangalore - Karnataka
Tender for development of nagavara lake by enhancing storage capacity of lake through desilting and removal of slush, construction of wetland, sewage diversion drain, installation of sluice gate, water body protection and other allied works
  • View Tender
  • Document
  • Bid Support
7 Construction
image image
Corporations/Associations/Others
TRN :34433262 |  12 May, 2025
Tender Value : 0
 Bangalore - Karnataka
Tender for development of chikkabeguru lake by constructing wetland areas , increasing storage capacity of lake through desilting and removal slush , sewage diversion drain , water body protection other allied works
  • View Tender
  • Document
  • Bid Support
8 Enviromental/Forest Division
image image
State Government
TRN :34436006 |  14 May, 2025
Tender Value : 11.73 Lacs
 Chandigarh Ut - Chandigarh
Tender for removal of sludge for the regular maintenance of water bodies developed for the biological treatment of sewage water coming from village kansal in lake forest area
  • View Tender
  • Document
  • Bid Support
9 Security Services
image image
Central Government/Public Sector
TRN :48475497 |  17 May, 2025
Tender Value : 37.70 Crore
 Jaipur - Rajasthan
Tender for tender for provision of klp (ph-ii of two phases) for engr regt at jaipur mil stn; 1 lump sum price worked out by the contractor for building worksas listed in schedule ‘a’ part-i representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 2 lump sum price worked out by the contractor for internal water supply as listed in schedule ‘a’ part-ii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 3 lump sum price worked out by the contractor for internal electrificationas listed in schedule ‘a’ part-iii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 4 lump sum price worked out by the contractor for road, path and culvertas listed in schedule ‘a’ part-iv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 5 lump sum price worked out by the contractor for sewage disposalas listed in schedule ‘a’ part-v representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 6 lump sum price worked out by the contractor for area drainage as listed in schedule ‘a’ part-vi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 7 lump sum price worked out by the contractor for rain water harwestingas listed in schedule ‘a’ part-vii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 8 lump sum price worked out by the contractor for external water supplyas listed in schedule ‘a’ part-viii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the mes 9 lump sum price worked out by the contractor for external electrificationas listed in schedule ‘a’ part-ix representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the mes 10 lump sum price worked out by the contractor for parade ground of size 137 m x 91 m, footbal/hockey 02 nos, basketball courts 02 nos, volley ball courts 02 nos, hardstanding & badminton court 01 noas listed in schedule ‘a’ part-x representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the mes 11 lump sum price worked out by the contractor for compound wall, chain link fencing and gate as listed in schedule ‘a’ part-xi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 12 lump sum price worked out by the contractor for hot water supplyas listed in schedule ‘a’ part-xii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 13 lump sum price worked out by the contractor for refrigeration and cold water supplyas listed in schedule ‘a’ part-xiii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 14 lump sum price worked out by the contractor for site clearance, site developmentand earth workas listed in schedule ‘a’ part-xiv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 15 lump sum price worked out by the contractor for addn/altn of existing buildings & structures (b/r)as listed in schedule ‘a’ part-xv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 16 lump sum price worked out by the contractor for addn/altn of existing buildings & structures (e/m)as listed in schedule ‘a’ part-xvi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 17 lump sum price worked out by the contractor for demolition of buildings & shedsas listed in schedule ‘a’ part-xvii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 18 sch a part-xviii misc items (to be quoted by contractor) notes:(i) this schedule is not pre-priced by mes and the pre-priced rate indicated as rs 0.00 under column 5 signifies this fact only. (ii) excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under sch a part-xiv (site clearance, site developmentand earth work schedule). 19 pop ealse ceiling for sch a part i building work (officers mess & adm block)m&lforpop false ceilingof approveddesignconsisting of 10mm thick plaster of paris ceiling (gyspsum anhydrous) board including gi frame work for 12mm seamless ceiling comprising of gi perimeter channel of 0.55 mm thick with two unequal flange of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre intermediate channel 0.5 mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900 mm centre to centre with gi cleat and tee, expansion fasteners with and including ceiling section (not exc 1.2m length)of 0.55mm thickness having curved web of 50mm and flange of 26mm each with clips of 10.5mm fixed to intermediate channel with connectingclips across the intermediate channel of 457 mm centre to centre complete. 20 internal water supply (sch a part-ii) s & f 15mm bore angle valve/cock cast copper alloy fancy type screwed down high pressure with cructh or butterfly handle screwed both ends for iron pipe or brass ferrule fixed. make - cera-f1012201, jaquar - ari- chr-39053, kohler - k-80154in-4-cp 21 s & f wall mixer/diverter with diverter plate of bathroom 3 in 1 system with provision for both hand & over head shower with 115mm long bend pipe ( for mixer) connecting legs & wall flangs complete all as specified. make: cera-f1022403, jaquar-flr-chr-5281n, hindware-flora f280022 22 s & f chromium plated brass bath tub spout with wall flange(fancy type) suitable for 15mm bore pipe complete all as specified and directed. make- cera-f1012661, jaquar-spj-chr-429, hindware-f-520009 23 internal electrification (sch a part-iii)supply and fixing sp 63 amp rating, 240v, 10 ka c curve miniature circuit breaker (mcb) of following poles and current carrying capacity in the mcb db complete with connection testing and commissioning complete all as specified and as directed. 24 supply and fix tv coaxial,1 module socket complete all as specified and as directed. 25 s&f telephone socket(jack type) ,1 module rj11 with shutter complete all as specified and as directed. 26 m&l for electrolyte grade solid annealed copper conductor,jelly field,aluminium foiled and aluminium wire braided, rg59 (foam). cat part no. whojttkarg59make- havells or equivalent in as mentioned in appx b of particular specification 27 m&l for pvc insulated telephone cables for indoor applications confirming to technical specification g/wir06/02 cat part no.whttatea1p40 make-havells or equivalent in as mentioned in appx b of particular specification 28 s & f for highly efficient led bulbs, 9 watt complete all as specified and directed. make bajaj/havells/hpl 29 s & f blanking plate complete all as specified and directed. 30 s & f of sheet metal enclosure distribution board vtpn ,4 way, 415 volt, double door powder coated, protection class ip-54, isolated neutral bar, mechanical impact strength ik 09 suitable for mounting mcb & mccb dbs confirming to is-13032, is-8632,bs5484 with min 200 amp raiting copper bus bar and grouting, fixing on wall with nut boldts washers proper with pcc works complete all as specified and directed 31 rain water harwesting(sch a part-vii)borewell for rain water harvesting all as specified and shown on drg : (a) provision of trail bore by drilling with reverse rotary system550mm bore upto 52 m depth incl all works pertaining to boring complete in all respect in aluvium soil/ strata incl hard stone / boulder etc.(b)m&l for 150mm bore cpvc pipe assembly jointing, lowering in any position upto the reqd depth below given level incl jointing the pipe by solvent & screwing 04 nos screws in each joint complete all as directed.(c) ditto as item (b) above but slotted pipe(d) m& l for packing with pea gravel of 4.6 mm to 8mm size of approved quality as ordered to pack arround the casing / slooted pipe in borewell all as directed.(e) m&l 25 mm bore perforated cpvc pipe 52 mtr long for vent pipe 32 external water supply(sch a part-viii). m& l for cutting of existing pipeline of 100/150/80 mm dia for taking branch connection alongwith insertion of di tee and connecting material such as joint, nut bolts, etc all as required at site. 33 m&l for construction ofbrick stone masonary valve pit / chamber of size 900 mm x 600 mm x 1000 mm (internal dimensions) all as shown in drawing no td-573, including necessary excavation and earth work, pcc, plaster in cm 1:6 on inside and outside (above ground), ms angle iron 40 x 40x6.0 mm thick complete all as specified and directed and shown on drawings. 34 all as per item no 33.00 but chamber size 450 mm x 450 mm x 600 mm (internal dimensions) complete all as specified and directed 35 supply and fix stop valves 63mm dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed 36 external electrification . (sch a part-ix)supply and fixing led street light fitting 36 wattefficacy greater than 100 lumen/watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 65/66 protection complete all as specified and directed. make : phillips, cat no brp046 led 36 cw mr s1 psu gr 9405 or equivalent in as mentioned in appx b of particular specification 37 supply and fixing poly carbonatejunction box , weather and vermin proof of size 250x250x160 including provn of 4 nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators,including one no. mcb sp 6 amps for light control,drilling of holes.provn of suitable size of gi nuts, bolts, double washer and fi clamps ofsuitable sizefor taking connections and fixing on lt steel tubular poles complete with locking arrangement complete all as specified and directed. 38 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-(main ltp no-01 ) 39 incoming :-(a) mccb 4 pole 320 amp thermal magnetic protection type, 36kamake : legrand, cat no - 4220-06, dpx3 630- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc.(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100outgoing :-(a) mccb 3 pole 160amps thermal magnetic protection type, 36 ka, make : legrand, cat no - 4200-87, dpx 160- 01 nob) mccb 3 pole 200amps thermal magnetic protection type, 36 ka, make : legrand, cat no - 4202-08, dpx 250- 01 no (c) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(d) analog time switch, make- legrand, cat no 4127-80 for sl control 40 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -4. 41 incoming:- (a) mccb 4 pole 160 amps thermal magnetic protection type, 25 ka, make : legrand, cat no - 4200-57, dpx 160- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going:- (a) mccb 3 pole 63 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-43 - 02 no (single offr accn + ltp - 08)(b) mccb 3 pole 40 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-42 - 02 no ( servant qtr + sl)(c) mccb 3 pole 125 a thermal magnetic protection type, 25 ka dpx3 160, legrand, cat no 4200-06 - 01 (offr mess)(d) mcb dp 16amp - 01 no ( garage)(e) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(f) analog time switch, make- legrand, cat no 4127-80 for sl control 42 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp - 8incoming(a) mccb 4 pole 63 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-13 - 01 no 43 (b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 10 no 44 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -3. 45 incoming(a) mccb 4 pole 200 amps thermal magnetic protection type, 25 ka, make : legrand, cat no - 4202-18, dpx 250- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mccb 3 pole 100 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-45 - 01 no(ltp - 06)(b) mccb 3 pole 160 a thermal magnetic protection type, 25 ka dpx3 160, legrand, cat no 4200-47 - 01 (adm bldg)(c) mccb 3 pole 40 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-02 - 02 no (saa stores + old guard house)(d) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 03 no(e) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider (f) analog time switch, make- legrand, cat no 4127-80 for sl control 46 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -6 47 incoming(a) mccb 4 pole 100 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-55 - 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out goingm(a) mccb 3 pole 63 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-43 - 01 no (b) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 05 no 48 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -7 49 incoming(a) mccb 4 pole 63 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-53 - 01 no (b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mccb 3 pole 40 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-02 - 02 no ( bch + mt office)(b) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 13 no (garage) (c) mcb 3 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-55 - 02 no (car washing + longe wala gate) 50 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:- (main ltp no-02 ) 51 incoming (a) mccb 4 pole 400 amp thermal magnetic protection type, 36kamake : legrand, cat no - 4220-07, dpx3 630- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100outgoing (a) mccb 3 pole 200amps thermal magnetic protection type, 36 ka, make : legrand, cat no - 4202-08, dpx 250- 01 no(ltp -02)(b) mccb 3 pole 160amps thermal magnetic protection type, 36 ka, make : legrand, cat no - 4200-87, dpx 160- 01 no (ltp - 01)(c) mccb 3 pole 40 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-42 - 01 no(ltp - 5)(d) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(e) analog time switch, make- legrand, cat no 4127-80 for sl control 52 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -1 53 incoming(a) mccb 4 pole 160amps thermal magnetic protection type, 25 ka, make : legrand, cat no - 4200-57, dpx3 160- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mccb 3 pole 40 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-42 - 01 no ( ltp -5)(b) mccb 3 pole 25 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-01 - 02 no ( fwc + ori )(c) mccb 3 pole 16 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-00 - 02 no ( religious hall + unit shop)(d) mccb 3 pole 80 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-44 - 01 no ( trademen shop)(e) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider (f) analog time switch, make- legrand, cat no 4127-80 for sl control 54 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -5incoming(a) mccb 4 pole 40 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-12 - 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100 55 out going(a) mccb 3 pole 16 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-00 - 01 no ( drying & ironing)(b) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 4 no (car shed - 01 no + scooter shed - 01 no + dhobi ghat - 02 nos) (c) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(d) analog time switch, make- legrand, cat no 4127-80 for sl control 56 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system 57 and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -2incoming(a) mccb 4 pole 200amps thermal magnetic protection type, 25 ka, make : legrand, cat no - 4202-18, dpx3 250- 01 no (b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mccb 3 pole 25 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-41 - 02 no (s/l jco)(b) mccb 3 pole 16 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-00 - 04 no ( s/l 01 jco + engr store + def store + old bldg)(c) mccb 3 pole 80 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-44 - 01 no ( jcos mess)(d) mccb 3 pole 63 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-43 - 01 no (mi room)(e) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 4 nos (car shed - 01 no + scooter shed - 01 no + garage for amb - 01 no +car shed/scooter shed - 01 no ) (f) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(g) analog time switch, make- legrand, cat no 4127-80 for sl control 58 taking down old cable xlpe insulated ,screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor off sizes from existing site 59 dismentling street light bracket off sizes complete all as specified and directed 60 dismantling and taking down lt feeder pillar box off size complete all as specified and directed 61 dismantling and taking down outdoor distribution box off size complete all as specified and directed 62 dismantling and taking down transformers 160 kva to 500 kva and deposit to mes store yard or keeping in safe custody for re-installation complete all as specified and directed 63 parade ground of size 137 m x 91 m, footbal/hockey 02 nos, basketball courts 02 nos, volley ball courts 02 nos, hardstanding & badminton court 01 no (sch a part-x (synthetic floor / mat for basket ball & volley ball courts) m & l for antifungal, anti microbial and u/v resistant comprising of pvc wear resisting coat thickness of 3.5mm to 8mm over of fiber-glass reinforced layer with pvc foaming buffer layer of thickness 4.5mm for good performance in rebounding & absorbing shock complete all as specified and directed 64 refrigeration and cold water supply(sch a part -xiii)supply and fix refrigerator, electric driven (single phase),direct cool single door 5 star refrigeratorwith base drawer with smart inverter compressorcapacitynot less than 185 litrescomplete all as specified and directed 65 supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of ± 2.5% and of capacity not less than 2.0kva complete all as specified and directed 66 supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 cum per hour (or nearest size) steel body complete all as specified and directed 67 addn/altn of existing buildings & structures (b/r) : schedule a part -xvm & l for providing 5-7mm thick screed bed ofchemical adhresive of approved make for laying floor finishes i,e floor tile etc. complete all as specified and directed. 68 taking down existing water proofing roof treatment of any description cleaning the surface by hacking to received plaster complete all as specified and removing demolised material outside mod land. 69 s & f fibre reinforced uv resistant elastomeric liquid applied waterproofing & heat reflective coating with acrylic polymers and polyester/glass fibres after scraping and properly cleaning the surface to remove loose perticles with wire brushes complete or as directed water proofing treatment shall be in three coats over a coat of primer and as per manufacturers instructions complete all as specified and directed. 70 m & l for retrieving vegetation growth/plants from wall roofs, chajja upto double storey height incl taking out deep roots and pouring hcl acid and making good the distrubance surfaces with cm 1:4 incl all means required at site complete all as specified and directed 71 addn/altn of existing buildings & structures (e/m) : schedule a part -xvitaking down of existing unsv sub main wiring any size incl pvc/steel conduit complete and making good to disturbed surfaces complete all as specified and directed. 72 taking down of existing unsv dbs any size complete all as specified and directed 73 supply & fixing of mcbs, 10 ka rupturing capacity, is-8828 marked,dp 10 ampsand fixing in dbs complete all as specified and directed(note:- dbs shall be measured and paid separately in respective item) 74 all as per items no 63.00 butdp 20 amps 75 all as per items no no 63.00 but 4p 25 amps 76 all as per items no no 63.00 but sp 6 amps 77 all as per items no no 63.00 but sp 10 amps 78 all as per items no no 63.00 but sp 20 amps 79 demolition of buildings & sheds : schedule a part -xvii taking down carefully by carefully unscrewing serviceable/unserviceable dbs,any sizes 415 volt complete with bus bar and rails for easy mounting of mcbs complete with from boards and disconnecting from incoming and outgoing complete all as specified and directed 80 taking down sub main wiring of any sizes complete all as specified and directed 81 arbouriculture work laying of lawns including ploughing leveling breaking of clods manuring & removal of stones etc. (cost of manure or extra good earth to be paid separately) maintenance of lawns for 30 days more till the grass forms a thick lawns free from weeds & fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost. in rows 5 cms. apart in either direction 82 supply of different flower plants 900mm to 1500mm at site including loading / unloading & transportation etc.complete all as specified and directed 83 supply of different varieties of shrubs 600mm to 900mm at site including loading / unloading & transportation etc.complete all as specified and directed 84 supply of different varieties of climbers 900mm to 1500mm at site including loading / unloading & transportation etc.complete all as specified and directed 85 supply of different varieties of palms in polyethylene bags / earthen pots according to height growth & age of the plant at site including loading / unloading & transportation etc .complete all as specified and directed 86 supply & planting of shady plants (neem, peepal, goolar, jamun, imli or other specified) along including the following activities :-(a)preparation of soil including & removing of unwanted shrubs removal of stones & garbage.(b) supply of plant at site of two years of age & height more than 1.50mtr.(c)supply of dry manure (farm yard manure.(d)supply of insecticides.(e)digging of pits size 60x60x60 cms. 87 supply & planting of ornamental plants (kachnar, amaltas, gulmohar, arjun, jacranda etc. or other specified) along including the following activities :-(a)preparation of soil including cleaning & removing of unwanted shrubs removal of stones & garbage.(b)supply of plant at site oftwo years of age & height more than 1.50mtr.(c)supply of dry manure (farm yard manure organic).(d)supply of insecticides.(e)digging of pits size 60x60x60 cms. including removal of stones, manu-ring application of insecticides & watering at least15 liter per plant after planting.(f)watering to plants.
  • View Tender
  • Document
  • Bid Support
10 Security Services
image image
Central Government/Public Sector
TRN :48280497 |  17 May, 2025
Tender Value : 4.14 Crore
 Leh - Ladakh
Tender for tender for provision of central mi room at nimu(job no 01/nimu stn/amwp/2023-24); 1 lump sum price worked out by the contractor for building worksas listed in schedule ‘a’ part-i representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 43 2 lump sum price worked out by the contractor for (site clearance, excavation & earth work)as listed in schedule ‘a’ part-ii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 44 3 lump sum price worked out by the contractor for (internal electrification)as listed in schedule ‘a’ part-iii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 50 4 lump sum price worked out by the contractor for (internal water supply)as listed in schedule ‘a’ part-iv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 52 5 lump sum price worked out by the contractor for (road, path & hardstanding)as listed in schedule ‘a’ part-v representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 54 6 lump sum price worked out by the contractor for (sewage disposal)as listed in schedule ‘a’ part-vi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 55 7 lump sum price worked out by the contractor for (area drainage)as listed in schedule ‘a’ part-vii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 56 8 lump sum price worked out by the contractor for (shed for dg set)as listed in schedule ‘a’ part-viii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 58 9 lump sum price worked out by the contractor for (hot water supply)as listed in schedule ‘a’ part-ix representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 59 10 lump sum price worked out by the contractor for (external electrification)as listed in schedule ‘a’ part-x representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 65 11 lump sum price worked out by the contractor for (external water suplay)as listed in schedule ‘a’ part-xi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 66 12 sch a part - xii (misc b/r & e/m items) (refer boq)note: this schedule is not pre-priced by mes and the rate indicated as rs 0.00 under col 5 signifies this fact only 13 internal electrifications&f double door three phase prewired distribution board vertical db vtpn 8 way with acrylic door made out of crca sheets 1.6 mm thick,phosphatised powder coated with copper bus bar 200 amps, 415 v,ip 43/ik09, earth stud, din rail, polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingmccb4 pole 63 amp rating repturing capacity 16 ka.(note:- single phase mcbs are to be measured and paid for seperately) 14 s&f led building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240v, ip 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long med grade gi pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith ms clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm pvc insulated 3 core wire complete all as directed and specified by engr-in-charge.note - cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 s&f new wall mounted fan of approved make and type complete all as specified and as directed. 16 s&f tv co-axial socket 1 module, complete all as specified and as directed. 17 s&f single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole mcb 20 amps 18 internal water supplys&f single piece vitreous china wash down water closet pan pedestal pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type b-0, as in repairs complete all as spd & directed complete all as specified and directed by engr-in charge.. 19 s&f cp grating including jointing to waste pipe fixed in cement concrete type b-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by engr-in charge. 20 s&f hand shower (health faucet ) with 8mm dia and 1 meter long cp flexible tube and wall hookcomplete all as specified make: cera, jaquar , marc & hindware as per sample and directed by engr -in charge 21 s&f soap dish (s/s), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by engr-in charge. 22 road, path & hard standingm&l for wet mix macadam (wmm) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of morth (ministry of road transport & highways) specification of road and bridge works 2013. manufactured in wmm plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 kn static weight and conslidating required gradient and camber. the finished surface tolerance to be as per table 900-1 of morth specification for road and bridge works 2013 complete all as specified and directed by engr-in-charge. 23 m&l for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to bs 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 m&l for rcc septic tank designed to carry sewage and sullage water, excavation in any type of soil, pcc 1:4:8 below foundation, rcc m-30 design mix in walls , base slab , baffle walls and roof slab including beams etc with vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 m&l for soakage wells excavation, in any type of soil, foundation in pcc 1:3:6, walls of honey combed masonry with top ring of m25 concrete including intercepting chamber and screen chamber made of brick masonary in cm, rcc cover slab in m25/ sfrc cover, interconnecting pipes of rcc/dwc complete filled with brick bats of size 3m dia and 3 m depth. 26 s&f pvc junction boxes ip 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 nos mcb sp 2.5 amp & 4 way industrial connector including clamp made out of ms flat 30x5mm connection from junction box to street light fitting with three single core pvc insulated, pvc sheathed wire 2.5 sqmm copper & pvc conduit 20 mm dia complete all as specified and directed by engr-in-charge. 27 excavation in trenches by cutting of road crossing/pcc hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by engr-in-charge. 28 s&fht/lt ms cable route indicator 4 dia fixed with two nos of nut, bolt and washers and provision of pcc 1 : 4 : 8 type d-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by engr-in-charge. 29 supply, installation, testing and commissinoning lt panel board suitable for working on 3 phase ,4 wire ,415 volts, ac ,50hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick crca sheetduly powder coated and shall be cpri approved and as approved by ge. the panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, copper bus bar duly covered with heat shrink sleeves colour coaded duly fixed ondmc/smc insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing mccbs shall have extended bus bar links and mounted on 50x50x5mm sizems angle iron frame duly painted including pcc 1:2:4 type b1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of age (i) nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) mccb 400 amps, fp, 36 ka, 415 volts, 50hz - 01 no (i/c)(b) mccb 200 amps, fp, 25 ka, 415 volts, 50hz - 02 no ( chs)(c) mccb 125 amps, fp, 18 ka, 415 volts, 50hz - 04 nos (apfc, tpn db -02, spare )(d) mcb spn 40 amps, 10 ka, 220 volts, 50hz - 03 nos (garage,street light, spare-1)(e) on load chengeover 630 amps 4 pole -01 no (f)digital voltmeter, with vss - 01set(g) digital ammeter, with cts & ass - 01 set(h) led phase indication lamps ryb - 01 set(j)single phase rotary automatic light controller nature switch with voltage range 120-440v,ac,20 amps,ip-65,50hz-01 nos(k) copper bus bar tpn 600 amps rating - 01 set 31 labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and gi tubing in soft/loose soil complete all as specified. 32 m&lfor cutting existing gi pipes and insertion of new tee branches of suitable size to take branch connection of 50mm dia pp-r.note : suitable size of tee branch is deemed to be included in the quoted rate. 33 construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingpcc in foundation of the mixture (1:4:8) d-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) ms steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed ms work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in pcc with two coats of black bituminuos paint andall other relevant work complete . 34 m&l for providing tracer/anti freezing cable required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (central heating system)electric hot water generator : supply, installation, testing and commissioning ofpackage type electric hot water generator constructed out of ms sheet having top open-able cover for easy access and removal of heaters. the hwg shall be suitable for indoor mounting. the generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22g aluminium cladding sheet. the generator shall have electrical capacity of 50 kw. the heater shall be electrical resistance type, copper tube with chromium plating. the generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. the generator shall be suitable for 3 phase, 415+ 10% volts, 50 hz. ac supply. the generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 notes:- (i) allneccassary accessories required for the proper fucntioning of hot water genearator are included in price.(ii) the prices should include lifting, shifting and positioning of units at site.(iii) hot water genearator installation to done as per manufacturer recommendation with all installation requirements i.e foundation, vibration isolator,insulationetc as recommended by manufacturer for the ambient temperature of site. odu installation is included in odu price which includes the civil struture, mechanical structureetc as recommended bymanufacturer.(iv) the contractor/oem will shall submit the hot water generator capacity/burner capacity conforming to relevant is code(v) oem should submit the installation and maintenance schedule/ manual for the boiler. 37 glycol circulation centrifugal pumps: supply, installation, testing & commissioning of pn16 ratedaxial split coupled vertical inline water pump set with ci casing, bronze impeller, ss shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with suitable hp, tefc squirrel cage induction motor with ie3 type class f insulation, motor shall be rating of ip 55, operating on 415 ±10% volts, 3 phase, 50hz ac supply. the external flush line must be used for the purpose of heat dissipation from the mechanical seal.pumps with performance characteristics as given below:the internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 degree celcius to 120 degree celcius. vendor shall be provide antivibration arrangement for pumps . 38 the scope also shall include following below mentioned:(i) electrical by pass starter for pump setas recommended by oem. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) pressure gauges 150 mm dia -03 nos (iv) mounting frame with antivibration pads (in case pumps are inline, anti vibration system shall be as per manufacturers recommendation) (v) rcc/cement concrete foundation for the pump unit. (in case pumps are inline, foundation shall be as per manufacturers recommendation).pump capacity are as under:capacityand pump headnot less than flow 25 usgpm , head 20 mtr (refernce model no. : armstrong : series 4300 - 40-150 - 2p - 1.5 kw) each including the triple duty valve and end suction guide. 39 expansion tank and pressurisation unit:supply, installation, testing and commissioning of insulated pressurised closed water expansion tank suitable for total volume ofglycol - water solution, circuit along with necessary accessories such as along with necessary accessories such as 2 nos pumps (1working +1standby) with pressure transmitter andinterconnecting pipe & isolating valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with pressure transmitter andinterconnecting pipe & isolating valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. the tank shall be pre-charged. expansion tank shall be with replaceable heavy duty butyl rubber bladder. the tankconnections should be as per oem recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.the tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. the tank must be constructed in accordance with is-standard 2825-1969 (withlates revision)and rated at pn 16 . the complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.the tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelip55 control panel, pressure transmitter, interconnecting piping & wiring. (tank capacity 500 ltrs). hot glycol - water closed vessel pressurized expansion tank as described above shall be duly insulated with 50 mm thick puf/nitrile rubber insulating material or equivalent u valueinsulating material and cladded with aluminium sheet (20g). electrical by pass starter for pump setas recommended by oem. 40 expansion tank of 500 lts capacity 41 pressurization unit: for pump set -03 nos with control panel and accessories. 42 make up tank: supply, installation, testing and commissioning of factory made make up water tank, rectangular/circular shape, of 4 mm thick ms sheet (is 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of ms and vent with flame arrestor. tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above ffl. service platform shall be provided as per recommendations of oem. the tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. extra high level and extra low level alarm shall be provided. tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.make up water tank as describedabove should beduly insulated with 50 mm thick puf/nitrile rubber insulating material and cladded with aluminium sheet (20g). 43 supply, installation, testing and commissioning ofsteel plate radiator( wall mounted) confirming en- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°c, complete with top grill side cover as standard along with inlet ,outlet valve, air purge valve andwith threaded plug, flow regulator as per oem.the below desired capacity should be calculated at altitude of 3600 mts above sea level. capacity calculation sheet to be provided to engineer in charge. the below mentioned capacity is at inlet temp: 75 degree celcius , outlet temp: 65 degree celcius. referemcwe model series. 44 1.5 kw, type: 33- dkek, length is 1000 mm and height is 600 mm of radiator. 45 2.5 kw, type: 33- dkek, length is 1000 mm and height is 600 mm of radiator. 46 3.5 kw,type: 33- dkek, length is 1600 mm and height is 600 mm of radiator. 47 5 kw,type: 33- dkek, length is 1600 mm and height is 900 mm of radiator. 48 5 kw,type: 33- dkek, length is 2000 mm and height is 600 mm of radiator 49 m & l for pre-insulated ms pipe,class c havingminimum thicknes of puf insulation as mentioned below and of density 36 kg/cum and 26 gauge al cladding complete suitable for above ground as per sizes shown.the pipes should be insulated with closed cell puf of density 36±2 kg/cum of below mentioned thickness. the pipe should be workable in the temp. range of-50 degree celciusto120 degreec celcius. note:-the pipes size 150mm & below shall be m.s. ‘c’ class as per is : 1239 50 80 mm with 36 mm puf thicknes and 26 gauge al cladding. 51 50 mm with 36 mm puf thicknes and 26 gauge al cladding. 52 50 mm with 36 mm puf thicknes and 26 gauge al cladding. 53 40 mm with 36 mm puf thicknes and 26 gauge al cladding. 54 20 mm with 36 mm puf thicknes and 26 gauge al cladding. 55 buried under ground/exposed to ambient:80 mm with 50 mm puf thicknes and hdpe cladding, 26 gauge al cladding. 56 cabel tray :-supplying and installing following size of perforated painted with powder coating m.s. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/ground/wall with m.s. suspenders as per is code including bolts & nuts, painting suspenders etc. as required of size 150 mm width x 50 mm depth x 1.6 mm thickness 57 supplying, fixing, testing and commissioning of following diameter valves (pn-16 rating) (complete with flanges integral or welded, fittings, nuts, bolts & gaskets (pn-16 rating), strainers (complete with flanges integral or welded, fittings, nuts, bolts & gaskets (pn-16 rating), gauges etc for condenser water circulation as per specifications. insulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as specified. butterfly valve ( insulated valves) with ci body ss disc nitrile sheet & o ring, complete with fittings, nuts, bolts & gaskets.butterfly valve ( insulated valves) with ci body ss disc nitrile sheet & o ring, complete with fittings, nuts, bolts & gaskets. 58 80 mm dia butterfly valve 59 65 mm dia butterfly valve 60 50 mm dia butterfly valve 61 supplying, fixing, testing and commissioning of y-strainer (insulated valves) of ductile ci body flanged ends with stainless steel strainer forhot water circulation including insulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as specified of size 50 mm dia y strainer. 62 supplying, fixing, testing and commissioning of non - return valve (insulated valves) with duel plate of ci body ss plates vulcanized nbr seal flanged end & pn 16 pressure rating forhot water circulation includinginsulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as sepcified of size 50 mm dia nrv. 63 supplying, fixing, testing and commissioning of automatic air purge valves forhot water circulation headeras specified of size automtic air purge valve 20 mm dia. 64 supplying, fixing, testing and commissioning of air separator compleate allas specified of size 50 mm dia. 65 supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and ss tubing, socket.range (0-50) / (0-100) as required by engineer in charge. 66 supplying, fixing, testing and commissioning of mercury in glass industrial thermometer in ss-304 casing with 0.5 c least count, range 0-50 c. brass oil filled thermowell of 1/2 size as required by engineer in charge. 67 electrical distribution panel supply, installation, commissioning and testing of factory made, chs plant, indoor type made out of crca sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with ms angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 phase4 wire, 415 volts, 50 hz, ac supply system, floor mounted and grounting the legs of panel in pcc foundation 1:4:8 complete as all directed suitable for and including the following :- 68 incomers(i) bus bar tpn al extensible type main bus bars of minimum of 600 a capacity (as per capacity of corresponding incoming / bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c smc bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50ka .(ii)mccb 400 amps, 415 volt, 36 ka, 4 pole,microprocessor release- 01 no for incoming (extended rotary operating handle, phase spreader links and phase barriers ) make: legrand/schenider/simensoutgoings(i) 3nos- 125a ,25 ka tpnmccb/acbwith microprocessor release (3# hot water generator)(ii) mcb 10 amp,tpn,10ka, c curve - 06, 3 nos for pumps , 2 nos for pumps ,01 nos for glycol transfer pump(iii) led phase indication lamps (01 set) with 2amp back up mcb,breaker on/off indicating light with 2a mcb, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 set (iv) digital ammeter with in built ass,metering c.t.scast resin type, 15va, and accuracy class-1of 800/5a for measuring current in each phase - 01 set.(v) all accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per manufacturers recommendations all as directed by engnr-in-charge.note : contractor will submit the drawing for approval of panel to ge before execution. 69 lt cables : supply & laying/ fixing of following size xlpe insulated and pvc sheathed copper conductor armoured cable/unarmoured as required of 1.1 kv grade complete as require (isi marked) (in ground/in pipe/in duct/on surface/on cable tray) 70 3.5 core x 70 sq.mm. (electric hot water generator) 71 4.0 core x 10 sq.mm. (pump) and (pressurization unit) 72 2 core x 10 sq.mm. (pump) 73 2 core x 6 sq.mm (pressurization unit) 74 earthing complete with copperearth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long gi pipe connected to main controlboard and gi pipe light grade 20mm bore for watering and including funnel, wire mesh, rcc pit cover 50mm thick and pcc chamber pit with pcc 1:2:4 type c2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate no 3 of ssr part-i 2009 complete all as specified & directed by engr-in-charge 75 s&f rubber matting conforming to is-15652-2006 complete as required. of size2m x 1m x 25 mm 76 glycol - water solutionsupplying of ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.note;- (i) the glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. the glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 degree celcius (ii) first charge of glycol is included in the quoted rate. first charge include charge in chs pipe linestorage tank. (glycol 45 % ,water 55 %) 77 for chs 78 supply of gycol for running of plant for 12 months 79 glycol circulating pump: supply, erection, testing and commissioning oftransfer pumps for the capacity of 5 lpm 5 meter head for glycol fluidtransfer with base frame foundation, bolts coupling coupling guard,tefc, (oem design hp for the required flowand head ) andother accessories for proper function of the pump. 80 oxygen gas manhold : supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, nrv and essab make 10x14 regulator complete all as specified and directed by engr in charge . 81 supply , installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by engr in charge . 82 supply , installation , testing and commission automatic control panel with analog display 02 for oxygen complete all as specified and directed by engr in charge. 83 s&f of copper tubing of size 15 mm od, en -13348 grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by engr in charge. 84 s&f of copper tubing of size 12 mm od, en -13348 grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by engr in charge. 85 s&f bs type gas outle with probe for oxygen for medical compleate all as specified and directed by engr in charge 86 s&f 1/2 brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by engr in charge. 87 s&f bpc flow meter (0-15 lpm) including humidfire bottle complete all as specified and directed by engr in charge . 88 s&f 3/8 brass ball valveincluding all fittings for complete all as specified and directed by engr in charge. 89 stand by dg set : supply,install, test and commissioning of silent diesel engine generating set 415 volts, 3 phase, 4 wireengine as per is08528 conforming to cpcb norms iv, and alternator as per is08528 of capacity 400 kva at ntp with control panel having meters, sound proof canopy etc with foundation (as per oem design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- ac generator should be suitable for ambient conditions at nimu leh area. 90 (a) alternator : standard design alternator rated at 400 kva (320kw)net output at power factor 0.8, ac, 3 phase 4 wire, 415 v, 50 cycles/second, 1500 rpm self excited, self regulated, screen protected, drip proof ip 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (b)diesel engine : vertical diesel engine of suitable capacity, water cooled, closed circuit as per bs-649 or is-1002 direct injection type turbo charged, electric starting system having rated speed 1500 rpm. the dg set shall be capable for running with 10% over loading for 01 hour in every 12 hours as perbs-5514/bs-649. engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following specifications.(a) fly wheel with housing (i) common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) cooling system (i) radiator with fan & belts & guard, rubber hoses and thermostat. (ii) cooling water pump centrifugal type . 91 (c) governer : electronic governer (d) electric starting system : electric self starter , 24 volts dc(12 volt, 150 ah battery 2 nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2x12 volt 150 ah capacity. (e) generator monitoring panel : comprising of following :- (i) microprocessor based genset controller for metering, monitoring, governing and protection. (ii) engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) accessories:avm pads built or separately mounted to manufacturer base frames. (g) coupling arrangements: fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) exhaust system : should have equipped with emission control device as per latest govt norms. silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) fuel tank: daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (c)acoustic enclosure : all as per cpcb norms iv and oem of dg sets design.(d)amf panel : supply, install, testing and commissioning of amf panel outdoor type, cubical body,dust and vermin proofmade up of crca sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to ip 45 with front and rear opening with louvers andmounted on floor with pcc pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) microprocessor based panel -01 no(ii) power contactor heavy duty suitable for generator and mains (iii) over load relay for genset (iv) suitable rating isolating switch mccb for both dg & main supply.(v) multi functioning meter to indicate voltage, current, frequency, p f, kw & kwh etc (vi) emergency stop push button.(vii)set of indicaters : - (a)low lube oil pressure (b) dg set over load(viii) push button to start, stop (ix) mode selector switch i.e auto/manual/test/ off.(x) set of instrument fuse (xi)set of aluminium bus bar of 600 amps capacity 3 ph, 4 wire system (xii) automatic battery charging unit with dc voltmeter, ammeter and selector switch for trickle/ boost charging.(xiii) by pass arrangement of main supply when amf circuit fail due to any fault with provision of suitable rating change overs and switches. 93 the following items are deemed to be included in the rate quoted for all dg sets:- (i) dhpp for testing purpose shall be supplied by the contractor without any extra cost to department. (ii)the contractor shall arrange for artificial load (water load/electrical load) for testing for final testing of dg set at site and the cost is deemed to be including in above offer. (iii) testing of sound level should carried out at the site in presence of engineer-in-charge(iv) one set of latest spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) all civil works including foundation for dgset as per manufacturers drawing/ specification, foundation for amf panel shall deemed to be included in the quoted rate.(vi) the rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
  • View Tender
  • Document
  • Bid Support
  • 1
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : sewage removal
  • Drains Tenders ,
  • Drainage Crossing Tenders ,
  • Rcc Nalla Tenders ,
  • Drain System Tenders ,
  • Storm Drainage Repair Tenders ,
  • Rcc Gutter Repair Tenders ,
  • Drainage Network Tenders ,
  • Septic Tank Repair Tenders ,
  • Surface Drain Tenders ,
  • Strom Water Drainage Tenders

Get sewage removal Tender Alert...

734354

Related Searched Keywords : sewage removal

  • Underground Sewerage Tenders From Maharashtra
  • Finishing Work Tenders From Delhi
  • Earth Works Tenders From West-Bengal
  • Railway Under Bridge Tenders From -Tamil-Nadu
  • Desilting Work Tenders From Andhra-Pradesh
  • Flooring Tenders From Gujarat
  • Lift Irrigation Tenders From Karnataka
  • Dismantling Work Tenders From Uttar-Pradesh
  • Water Proof Tenders From Rajasthan
  • Civil Infrastructure Work Tenders From Madhya-Pradesh

Read More


Tender Document

670435

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Underground Sewer Tenders
  • Slab Flooring Tenders
  • Disilting Work Tenders
  • False Flooring Tenders
  • Wire Fence Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App