Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Metal Sheets
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of metal-sheets Tenders

List of latest metal-sheets Tenders in Indian Tenders. Click on any metal-sheets Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for metal-sheets Tenders.

Advance Search
  • All-Tenders (21)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
11 Construction
image image
State Government
TRN :49069074 |  15 May, 2025
Tender Value : 3.68 Crore
 Madhopur - Rajasthan
Tender for tender for major repair and modernization of existing emrs barnala (raj) - 1 earth work in surface excavation not exceeding 30cm. in depth but exceeding 1.5 meter in width as well as10 sqm on plan including disposal of excavated earth up to 50 mtr. and lift up to 1.5 mtr. disposed soil to be levelled and neatly dressed : all kinds of soil 2 earth work in excavation by mechanical means (hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. all kinds of soils 3 supplying and filling in plinth with river sand under floors including watering ramming consolidating and dressing complete including cost of sand 4 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - all work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 5 centering and shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 6 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement.m20 grade nominal mix / design mix providing m-25 grade concrete by usingcement as per codal provision instead ofm-20 grade design mix. 7 random rubble stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30 cm thick wall in:nt mortar 1:6 ( 1-cement : 6-sand). 8 anti termite treatment of floor using imidacloprid 30.5% ec non repellent, odorless, low dose, environmentally safe terniticide with rapid action non corrosive stain free, by drilling 12mm diameter holes 300mm apart injecting the emulsion as per specification and plugging with cement mortar 1:2 ( 1 cement : 2 coarse sand) in the whole floor area dpe 12mm dia termitube system with required number of junction boxes are to be installed. the termitube will run all along the perimeter wall both inside and outside. in the middle area the termitube to be installed at an interval of 1.00 mtr. or less both ways as required with sufficient number of junction boxes to pump the emulsion. after successful testing of termitube, pesticide emulsion of imidacloprid 30.5% ec mixed with water in the ration of 1:474 will be pumped by a motorized spray pump from the junction box in specified manner. the plinth area of the area treated will be measured for payment. 9 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : columns, pillars, posts and struts etc. 10 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 11 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.m20 grade nominal mix / design mixproviding m-25 grade concrete by usingcement as per codal provision instead ofm-20 grade design mix. 12 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.m20 grade nominal mix / design mix 13 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to is:1786) thermo-mechanically treated bars (conforming of relevent is code) 14 brick work with f.p.s. bricks of class designation 75 in superstructure above plinth level upto floor v level in all shapes and sizes in : cement mortar 1 : 4 (1 cement : 4 coarse sand) 15 half brick masonry in superstructure , above plinth level upto floor vlevelusing bricks of designation 75cement mortar 1 : 4 (1 cement : 4 coarse sand) 16 carriage of materials:earth,sand ,line morrum,manure or sludge , lead up to 5km 17 filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 18 random rubble dry stone kharanja under floor. 19 p & f 1st quality heavy duty vitrified double charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to is 15622 of approved make in all colour and shade, laid with 20 mm thick cm 1: 4 including grounting the joints with white cement and matching pigment etc complete. size600 mm x 600mm 20 rough chisel dressed sandstone 35 mm thick flooring of approved shade setover 20mm thick base of cement mortar 1:6 (1 cement : 6 coarse sand) and pointingwith cement sand mortar 1:3 with pigment to match the shade of stone with joint thickness up to 15 mm complete in all respects : red sand stone (karauli stone) 21 providing and fixing marble stone flooring table rubbed, 15-18 mm thick over 20mm (av.) thick base of cm 1:4 (1 cement : 4 coarse sand) jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. slabs bhaislana,abu,kishangarh zebra(black marble) above 3601 cm2 slabs 22 extra for providing edge moulding to 15-18mm thick marble/ granite/kota stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer-in-charge. granite/kota stone work full edge moulding 23 plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 24 extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 25 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 26 providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 & is :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 27 providing and fixing ist quality mat finished ceremic tile size 300x300mm confirming to is : 13753 coloured tile expect white, grey, ivory, fume red brown in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry including nicely finished joints using water proof joint filler power (untile or roffe make) and finishing with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster). 28 providing and fixing pressed steel door frames confirming to is 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with cc 1:2:4(m15 grade) complete as directed by engineer-in-charge :profile c 29 providing and fixing external grade board solid core single leaf flush door shutters isi 2202-67 marked using phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure a: 35 mm thick commercial veneer both side 30 providing and fixing factory made p.v.c. door frame of size 50x47mm with a wall thickness of5mm, made out of extruded 5mm rigid pvc foam sheet mitred at corners and joined with 2 nos. of 150mm long brackets of 15x15mm m.s. square tube, the vertical door profiles to be reinforced with 19x19mm m.s. square tube of 19 gauge, epdm rubber gasket weather seal to be provided through out the frame. the door frame to be fixed to the wall using m.s. screws of 65/100mm size complete as per manufacturers specification and direction of engineer-in-charge. 31 providing and fixing to existing door frames. 30mm thick factory made solid panel pvc door shutter consisting of frame made out of m.s. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles and 15 mm x15mm , top & bottom rails. m.s .frame shall have a coat of steel primers of approved make and manufacture m.s. frame covered with 5mm thick heat moulded pvc ‘c channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles; and 5mm thick, 95mm wide pvc sheet out of which 75 mm shall be flat and 20mm shall be tapered in 45 degreeon the inner side to form top and bottom rail and 115mm wide pvc sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. top bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2) thick, 20mm wide cross pvc sheet shall be provided as gap insert for top rail & bottom rail. panelling of 5mm thick pvc sheet to be fitted in the m.s. frame welded/ sealed to the stiles & rails with 7mm (5mm +2mm) thick x 15mm wide pvc sheet bending on inner side, and joined together with solvent cement adhesive. an additional 5mm thick pvc strip of 20mm width is to be stuck on the interior side of the ‘c channel using pvc solvent adhesive etc. complete as per direction of engineer-in-charge, manufacture’s specification & drawing.(for w.c.and bathroom door shutter). 32 providing and fixing of upvc casement openable windows (outward / inward): outer frame made from the extruded upvc windows profile section of size 60w x 60h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and three chamber constuction, white in finish, duly reinforced with 1.5mm thick gi section. all the four corners shall be mitered cut & thermal welded so as to form window frame. frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. fix mullion made of 60w x 80h mm upvc profile section with steel reinforcement shall be provided in windows having 2 or more openable shutters, as per the requirement. frame shall have co-extruded with epdm/tpe-e gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter.the shutter of outward openable window shall be made of size 60w x 74h mm and shutter of inward openable window shall be made of size 60w x 77h mm extruded 3 box multi-chamber upvc window profile section of white colour having outer wall thickness of 2.25mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick gi section duly mitered cut & thermal welded at all corners and fitted with upvc glazing bead of size 36 x 20mm with inner and outer co-extruded epdm/tpe-e weather seal gasket alongwith 6mm thick isi make plain float glass. all welding joints of frame and shutter shall be cleaned and milled with the cnc mechainism to provide uniform grooved finish on all visible jaints. hardware: window shutter are fixed with frame on 2.5mmthick ss301 grade friction hinge system to keep the window opened at desired angle. friction hinge also enables easy cleaning of glass on both side from the inside of building. 33 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete new plastered surface (three or more coats) 34 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. 35 painting exterior surface ofwallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect including scaffolding and safety provisionnew work 36 painting with synthetic enamel paint of approved brand and manufacture togive an even shade :two or more coats on new work 37 french sprit polishing : two or more coats on new work including a coat of wood filler 38 providing and fixing stainless steel railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). grade 304 39 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 40 grading roof for water proofing treatment withwater proffing compound cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 41 providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 42 providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 kg/sqm) on top of hot bitumen @ 1.7 kg/sqm. (1.40 kg ofvg-40 (30/40 )grade and 0.30 kg/sqm. ofvg-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of engineer-in-charge. 43 providing and fixing in position collapsible steel shutters with vertical m.s. channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of t-iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (to be measured and paid as per outer dimension). 44 making grooves as per design in plaster 10mm to 20mm wide. 45 making khurras 450 x 450mm with average minimum thickness 50mmcement concrete 1 : 2:4 over p.v.c. sheet 1 mtr. x 1 mtr. x 40micron finished with 12mm cement plaster 1 : 3 and onecoat of neat cement, rounding edges and making and finishing the out let complete. 46 providing and laying damp-proof course with cement concrete grade m-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification . 50mm thick. 47 filling of sunk portion of roof with earthen pots of required height including filling voids with 1:3:6 light concrete, using brick batscomplete levelling and dressing the surface by 50mm thick cement concrete 1:2:4 as per specification. 48 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (i) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @0.253 kg//sqm .this layer will be allowed to air cure for 4 hours. (ii) second layer of slurryof cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm this layer will be allowed to air cure for4 hours followed by water curing for 48 hours. the rates includes preparation of surface treatment & sealing of all joints ,corners,junction with polymer mixed slurry. 49 providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with c.p. brass screws and wooden plugs, etc., wherever necessary complete: 20 mm 50 providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate z sections and other sections of approved make conforming to is :733 and is :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required pvc/neoprene felt etc. aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing /paneling , c.p. brass/ stainless steel screws al. tower bolt & al. handle & al. aldrop etc.,all complete as per architectural drawings and thedirections of engineer- in – charge .(glazing and paneling to be paid for separately). for fixed portionpolyester powder coating aluminum( minimum thickness of powder coating 50 micron) 51 providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board grade i, type ii conforming to is : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with c.p. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 52 providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with pvs / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(cost of aluminium snap beading shall be paid in basicitem.) with float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) 53 providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 54 providing and fixing sun control film, thickness of film 1 mil visible light transmittance 4-24% & solar energy transmittance 42-51% & total solar energy rejection 37-43%of approved colour and shade , complete in all respect , at all level , as directed by engineer- in -charge. 55 providing and fixing double action hydraulic floor spring of approved brand and manufacture is : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece m.s. 56 s&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding. 57 p & f indian type white glazed vitreous china 1st quality w.c. orissa pan (is :2556 mark) with 100 mm vitreous china p or s trap including cutting and making good the wall and floor:size 530x410mm. 58 p & f european type white glazed vitreous china 1st quality double syphonic w.c (is :2556 mark) with p or s trap including cutting and making good the wall and floor 59 p & f 15 mm. dia connection pipe of approved quality/make :600 mm dia 60 p & f kitchen & lab. sink of approved make with c.i. brackets duly painted, 40 mm c.p. waste coupling, c.p. brass chain with rubber plug, 40 mm g.i. waste pipe up-to floor level complete including cutting and making good the wall & floor : fire clay glazed kitchen sink (i.s 771-1985marked) size 600 x 450 x 250mm. 61 p & f full-way valve (is:778 mark) or wheel valve of approved make : 62 gun-metal 15mm nominal bore. 63 gun-metal 25mm nominal bore. 64 p & f looking mirrors with p.v.c. frame of approved (atul modi guard saint gobin or equivalent)size 500 x 400 mm 65 p & f towel rail or ring of approved quality/ make: 66 c.p. brass towel rail with brackets 600x 20 mm 67 c.p. brass towel ring revolving type 68 p & f grating of approved quality /makestainless steel sheet size 125 mm diaheavy quality of approved make 69 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes (is 15778 : 2007 code) having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. (concealed work including cutting chases and making good the walls etc.,) 70 15mm dia nominal bore 71 25mm dia nominal bore 72 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes (is 15778 : 2007 code) having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings, this included jointing of pipes & fittings with one step cpvc solvent cement , trenching refilling & testing of joints complete as per direction of engineer in charge.(external work). 73 15mm dia nominal bore 74 25mm dia nominal bore 75 p & f bib cock (is : 8931 mark), superior quality of approved make: c.p. brass bib cock, 15 mm nominal bore 76 p & f stop cock (is :8931 mark), superior quality & of approved make: c.p. brass 15 mm nominal bore. 77 p&f soap dish or tray of approved quality/ make. c.p. brass heavy and superior quality 78 p&f bath shower of approved quality/ make . c.p. brass of heavy & superior quality 150mm. 79 p & f inlet connection (angle valves) superior quality, of approved make, for wash basin, gyser etc. c.p. inlet connection 15 mm brass (is:8931 marked)with 60 cm long thread and nut. 80 p & f ball cock (is :1703 mark) with rod & p.v.c. ball complete : brass wt.400 gm,15mm. 81 p & f pvc storage tank (is : 12701marked indicating the bis license no), of approved make with cover, 25mm dia 1m long g.i. over-flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 1000 litres capacity. 82 hoisting charges for each floor : 83 construction of manhole in all type of soil inner size 90 x 60 cm. 300 mm thick masonry in cm 1:6, 10 cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in cm 1:6, finished with floating neat cement, 50mm thick m-15 grade c.c. flooring, making channels, 80mm thick stone slab covering with 40mm thick m-15 grade c.c. flooring, cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead. depth up to 0.5 m 84 construction of chamber in all type of soil with 300 mm thick masonry in cm 1:6 m,10 cm thick c.c. 1:5:10 in foundation, 20mm thick insider plaster in cm 1:6, finished with floating neat cement, 50mm thick m-15 grade c.c. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. size 450 x 450mm depth upto0.5 m cement cover with frame 85 construction of septic tank in all types of soil with 40 cm .thick masonry in cm 1:6, 15 cm thick c.c bed of 1:5:10, m-15 gradec.c floor &rcc slab covering with m15 grade c.c. floor,50 mm thick stone slab partition walls, 20 mm thick plaster in cm 1:6 finished with neat floating cement, 4 nos stone foot rests of approved design ,two no. 450 mm dia each ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:-size 400 x140x150 cm.(for 50 users)with 115 mm thick rcc (m-20) slab with tor steel reinforcement 10mm ? @15 cm c/c bothways including shuttering complete in all respect 86 construction of open surfacedrain with 112mm thick brick masonry in cm 1:4,110mm thick base concrete 1:5:10, 37mm thick m-15 grade c.c. flooring ,12mm 1:4 cement plaster on all exposed faces of walls including top surface excavation & disposal of earth complete as per approved design/drawing: 150mm drain,225mm av. depth 87 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 88 75mm dia 89 110mm dia 90 160mm dia 91 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: 92 plain tee 110 mm 93 vent covel 75mm 94 plain floor trap 110mm dia 95 bend 87.5 - 75mm 96 bend 87.5 - 110mm 97 pipe clip- 110mm 98 coupler-110 mm dia 99 making connection of g.i. distribution branch with g.i. main including all fitting. beyond 25mm & upto 100mm dia 100 construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in cm 1:6, 80mm thick stone slab, jointing of slab in cm 1 : 3, ralthal, kharanja, 40 mm thick m-15 grade c.c flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.: size 300 cm. dia outside & 300 cm. depth . 101 p & f water closet seat covers with brass hinges complete : solid pvc (is 2548 marked) grade-i black for ewc. 102 p & f low level flushing cistern of 10 litres capacity (is : 2556 mark) of approved make with complete fittings c.i. brackets duly painted, brass ball cock with ball (is: 1703 mark) complete including cutting and making good the wall: pvc withpvcbend and superior internal fittings as per is : 7231 . 103 p & f jet spray for water closet with c.p. copper tube flange of approved make. 104 p & f wvc wash basin (ist quality is:2556 mark) of approved make with c.i. brackets duly painted 1 no. 15 mm c.p. pillar cock (is:8934 mark) & 32 mm c.p. brass waste coupling of approved make, p.v.c waste pipe with pvc nut 32 mm complete including cutting & making good the wall : size 580 mm x 450 mm 105 p & f flush cock/flush valve (is:9758 mark) or wc of approved quality make : c.p. brass push type exposed 25 mm nominal bore. 106 brick work with f.p.s. bricks of class designation 75 in superstructure above plinth level upto floor v level in all shapes and sizes in :cement mortar 1 : 6 (1 cement : 6 coarse sand) 107 random rubble stone masonry with hard stone in superstructure aboveplinth level and upto five levelabove 30cm. thick walls in : 108 repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead with cement mortar 1 :4 ( 1 cement : 4 coarse sand) 109 patch repair to cement concrete floor including digging out old floor in regular shape and removal of rubbish curing etc. complete in all respects. 110 labour charges for repair to door / window without using any material such as applying randha (finishing) tightening of bolts & screw etc. 111 p & f inlet connection (angle valves) superior quality, of approved make, for wash basin, gyser etc. c.p. inlet connection 15mm.brass (is : 8931 marked) 112 p & f 15 mm. dia connection pipe of approved quality/make : cp brass pipe with cp brass nuts upto length 600mm. 113 providing & fixing premium quality white glazed vitreous china sanitary wares (is:2556 mark) of approved make as per direction of engineer-in-charge including cutting and making good the wall and floor. double syphonic european w.c. with mounted w.v.c. flushing cistern of 10 litre capacity complete with all necessary internal fittings with hydraulic seat cover. 114 p & f indian type white glazed vitreous china 1st quality w.c. orissa pan (is :2556 mark) with 100 mm vitreous china p or s trap including cutting and making good the wall and floor: size 580x440mm. 115 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 116 providing and fixing fully panelled/partly panelled/double leaf shutter frames for doors as per approved design and drawings with approved ordinary c.p./ oxidised steel fittings as per annexure - a and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mm x 12mm on both faces complete : 35 mm thick nigeria wood grade i 117 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeold plastered surface (two or more coats) 118 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:old work (one or more coats ) two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect.old work (one or more coats ) 119 painting exterior surface ofwallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect including scaffolding and safety provision old work 120 providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 kg/sqm) on top of hot bitumen @ 1.7 kg/sqm. (1.40 kg ofvg-40 (30/40 )grade and 0.30 kg/sqm. ofvg-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of engineer-in-charge. 121 supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. 122 providing and fixing 1st quality mat finished ceremic tile size 300x300mm confirmingto is : 13755 and is : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 123 providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred weldedand grinded including hold fast of steel lugs 13mm x 3mm and 15 cm long embedded in c cblock 15 x 10 x 10 cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to framefor paitam fixing float glass 4mm thickpanes with glazing clips and metal sash putty andfixing of shutters frames peg stay, u shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of engineer-in –charge window openable. 124 providing and fixing concertina coil fencing with required dia 610 mm (having 15 nos. round per 6 metre length) up to 3m height of wall with existing angle iron y shaped placed 2.4 m or 3.00 m apart and with 9 horizontal r.b.t. stud tied with gi staples and gi clips to retain horizontal including necessary bolts or gi barbed wire tied to angle iron all complete as per direction of engineer in charge with reinforced barbed tape (r.b.t.)/spring core(2.5 mm thick) wire of high tensile strength of 165 kg/sq.mm with tape (0.52 mm thick) and weight 43.478 gm/metre (cost of ms angle, cc block shall be paid extra) 125 renewing glass panes,with putty and nails wherever necessary float glass panes of thickness 4 mm 126 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - all work up to plinth level. m10 grade nominal mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 40mm nominal size). 127 kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) for area of each slab from 2001 to 5000 sq.cm 128 earth work in excavation by mechanical means (hydraulic excavator ) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed : all kinds of soil
  • View Tender
  • Document
  • Bid Support
12 Metals And Minerals
image image
Central Government/Public Sector
TRN :34404893 |  12 May, 2025
Tender Value : 0
 Jamshedpur - Jharkhand
Tender for gem bids for clearing jungle including uprooting of rank vegetation grass brush wood trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. "supplying chemical emulsion in sealed containers including delivery as specified. chlorpyriphos or lindane emulsifiable concentrate of 20 percent" "diluting and injecting chemical emulsion for post constructional anti termite treatment excluding the cost of chemical emulsion along external wall where the apron is not provided using chemical emulsion at the rate 7.5 litres or sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall and rodding etc. complete isto with chlorpyriphos or lindane e.c. 20 percent with 1 percent concentration" "earth work in excavation by mechanical means hydraulic excavator or manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m all kinds of soil." filling available excavated earth excluding rock in trenches plinth sides of foundations etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m supplying and filling in plinth with sand under floors including watering ramming consolidating and dressing complete. "providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 1 isto 3 isto 6 1 cement 3 coarse sand zone iii 6 graded stone aggregate 20 mm nominal size " "providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering shuttering finishing and reinforcement all work up to plinth level isto 1 isto 1.5 isto 3 1 cement 1.5 coarse sand zone iii 3 graded stone aggregate 20 mm nominal size " "reinforced cement concrete work in walls any thickness including attached pilasters buttresses plinth roof and string courses fillets columns pillars piers abutments posts and struts etc. above plinth level up to floor five level excluding cost of centering shuttering finishing and reinforcement 1 isto 1.5 isto 3 1 cement 1.5 coarse sand zone iii 3 graded stone aggregate 20 mm nominal size " brick work with common burnt clay f.p.s. non modular bricks of class designation 7.5 in foundation and plinth in cement mortar 1 isto 6 1 cement 6 coarse sand brick work with common burnt clay f.p.s. non modular bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in cement mortar 1 isto 6 1 cement 6 coarse sand "half brick masonry with common burnt clay f .p .s. non modular bricks of class designation 7.5 in superstructure above plinth level up to floor v level. cement mortar 1 isto 4 1 cement 4 coarse sand " "centering and shuttering including strutting propping etc. and removal of form for foundations footings bases of columns etc. for mass concrete" "centering and shuttering including strutting propping etc. and removal of form for suspended floors roofs landings lintals beams balconies and access platform" "steel reinforcement for r.c.c. work including straightening cutting bending placing in position and binding all complete upto plinth level thermo mechanically treated bars of grade fe 500d or more make sail or tata or jindal " "15 mm cement plaster on the rough side of single or half brick wall of mix isto 1 isto 6 1 cement isto 6 fine sand rates for external plastic are for height upto 10m from ground level in less otherwise stated cement make nuvoco lafarge or ultratech or acc or as per direction of eic " "12 mm cement plaster of mix 1 isto 6 1 cement isto 6 fine sand rates for external plastic are for height upto 10m from ground level in less otherwise stated cement make nuvoco lafarge or ultratech or acc or as per direction of eic " "6 mm cement plaster of mix 1 isto 3 1 cement 3 fine sand rates for external plastic are for height upto 10m from ground level in less otherwise stated cement make nuvoco lafarge or ultratech or acc or as per direction of eic " neat cement punning. "finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade new work two or more coats applied at the rate 1.43 ltr or 10 sqm over and including priming coat of exterior primer applied at the rate 2.20 kg or 10 sqm make dulux or burger or asian paints or as per direction of eic" white washing with lime to give an even shade new work three or more coats mix with fevicol ddl and robin blue or as per direction of eic "painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. preferable make dulux or burger or asian paints or as per direction of eic make dulux or burger or asian paints or as per direction of eic" making plinth protection 50mm thick of cement concrete 1 isto 3 isto 6 1 cement 3 coarse sand zone iii 6 graded stone aggregate 20 mm nominal size over 75mm thick bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling and dressing and finishing the top smooth "providing and fixing angle iron frames for doors windows and ventilators of mild steel angle sections of size 35x35x5 mm joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing t iron frame or to the wall with dash fastener including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer all complete as per the direction of engineer in charge. make sail or tata or jindal " "providing and fixing isi marked flush door shutters conforming to is isto 2202 part i decorative type core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including isi marked stainless steel butt hinges with necessary screws" "structural steel work in single section fixed with or without connecting plate including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete. make sail or tata or jindal " 25 mm thick pvc flush door shutters made out of a one piece multi chamber extruded pvc section of the size of 762 mm into 25 mm or less as per requirement with an average wall thickness of 1 mm plus or minus 0.3 mm . pvc foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. m.s. tube having dimensions 19 mm into 19 mm and 1.0 mm plus or minus 0.1 mm is inserted along the hinge side of the door. core of the door shutter should be filled with high density polyurethane foam. the top and bottom edges of the shutter are covered with an end cap of the size 25 mm into 11 mm. door shutter shall be reinforced with special polymeric reinforcements as per manufacturer specification and direction of engineer in charge to take up necessary hardware and fixtures. stickers indicating the locations of hardware will be pasted at appropriate places "providing and fixing isi marked oxidised m.s. sliding door bolts with nuts and scrows etc. complete .as per the direction of directions of engineer in charge.300x16 mm " "providing and fixing ist quality ceramic glazed wall tiles conforming to is 15622 thickness to be specified by the manufacturer of approved make somany or kajaria or nitco in all colours shades except burgundy bottle green black of any size as approved by engineer in charge in skirting risers of steps and dados over 12 mm thick bed of cement mortar 1 isto 3 1 cement 3 coarse sand and jointing with grey cement slurry at the rate 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. make isto somany or kajaria or nitco or asian or as per direction of eic" "providing and laying vitrified floor tiles in different sizes thickness to be specified by the manufacturer with water absorption less than 0.08percent and conforming to is 15622 of approved make in all colours and shades laid on 20mm thick cement mortar 1 isto 4 1 cement 4 coarse sand jointing with grey cement slurry at the rate 3.3 kg or sqm including grouting the joints with white cement and matching pigments etc. complete. size of tile 600x600 mm make somany or kajaria or nitco or asian or as per direction of eic" "providing and fixing water closet squatting pan indian type w.c.pan with 100 mm sand cast iron p or s trap 10 litre low level white p.v.c. flushing cistern including flush pipe with manually controlled device handle lever conforming to is 7231 with all fittings and fixtures complete including cutting and making good the walls and floors wherever required white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests preferable make hindware or parrywair or hindustan or cera or direction of eic" "providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and c.p. brass spreaders with brass unions and g.i clamps complete including painting of fittings and brackets cutting and making good the walls and floors wherever required one urinal basin with 5 litre white p.v.c. automatic flushing cistern preferable make hindware or parrywair or hindustan or cera or direction of eic" "providing and fixing wash basin with c.i. brackets 15 mm c.p. brass pillar taps 32 mm c.p. brass waste of standard pattern including painting of fittings and brackets cutting and making good the walls wherever require isto white vitreous china wash basin size 630x450 mm with a single 15 mm c.p. brass pillar tap" "providing and fixing p.v.c. waste pipe for sink or wash basin including p.v.c. waste fittings complete. semi rigid pipe 32 mm dia" providing and fixing 600x450 mm beveled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with c.p . brass screws and washers complete. "providing and fixing brass bib cock of approved quality 15 mm nominal bore" "providing and fixing brass stop cock of approved quality 15 mm nominal bore" providing and fixing circular or hexagonal cast iron or m.s. sheet box for ceiling fan clamp of internal dia 140 mm 73 mm height top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron or m.s. sheet box by means of 3.3 mm dia round headed screws one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. providing and fixing isi marked oxidised m. s handles conforming to is 4992 with necessary screws etc. complete 125 mm providing and fixing bright finished brass hanging type floor door stopper with necessary screws etc. complete. providing and fixing is 12817 marked stainless steel butt hinges heavy weight with stainless steel screws etc. complete 100x60x2.50 mm "providing and fixing g.i. pipes complete with g.i. fittings including trenching and refilling etc. for external work a. 15 mm dia nominal bore preferable make tata or jindal or as per direction of eic" "providing and fixing g.i. pipes complete with g.i. fittings including trenching and refilling etc. for external work b. 20 mm dia nominal bore preferable make tata or jindal or as per direction of eic" providing and fixing g.i. pipes complete with g.i. fittings including trenching and refilling etc. for external work d. 50 mm dia nominal bore preferable make tata or jindal or as per direction of eic "providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is 13592 type a including jointing with seal ring conforming to is 5382 leaving 10 mm gap for thermal expansion single socketed pipes. 110 mm diameter" "providing and fixing gun metal gate valve with c.i. wheel of approved quality screwed end isto 20 mm nominal bore" "providing and fixing gun metal gate valve with c.i. wheel of approved quality screwed end isto 50 mm nominal bore" providing and placing on terrace at all floor levels polyethylene water storage tank is isto 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank. providing and fixing 100 mm sand cast iron grating for gully trap constructing brick masonry chamber for underground c.i. inspection chamber and bends with bricks in cement mortar 1 isto 4 1 cement 4 coarse sand c.i. cover with frame light duty 455x610 mm internal dimensions total weight of cover with frame to be not less than 38 kg weight of cover 23 kg and weight of frame 15 kg r.c.c. top slab with 1 isto 1.5 isto 3 mix 1 cement 1.5 fine sand isto 3 graded stone aggregate 20 mm nominal size foundation concrete 1 isto 5 isto 10 1 cement 5 fine sand 10 graded stone aggregate 40 mm nominal size inside plastering 12 mm thick with cement mortar 1 isto 3 1 cement isto 3 coarse sand finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets isto with common burnt clay f.p.s. non modular bricks of class designation 7.5 "constructing masonry chamber 30x30x50 cm inside in brick work in cement mortar 1 isto 4 1 cement isto 4 coarse sand for stop cock with c. i. surface box 100x100 x75 mm inside with hinged cover fixed in cement concrete slab 1 isto 2 isto 4 mix 1 cement isto 2 coarse sand isto 4 graded stone aggregate 20 mm nominal size i or c necessary excavation foundation concrete 1 isto 5 isto 10 1 cement isto 5 fine sand isto 10 graded stone aggregate 40mm nominal size and inside plastering with cement mortar 1 isto 3 1 cement isto 3 coarse sand 12mm thick finished with a floating coat of neat cement complete as per standard design isto with common burnt clay f.p.s. non modular bricks of class designation 7.5" providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level isto 1 isto 1.5 isto 3 1 cement isto 1 coarse sand zone iii 3 graded stone aggregate 20 mm nominal size making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter 1.8 m long complete as per standard design. with common burnt clay f.p.s. non modular bricks of class designation 7.5 "cement concrete flooring 1 isto 2 isto 4 1 cement isto 2 coarse sand isto 4 graded stone aggregate finished with a floating coat of neat cement including cement slurry but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate" "providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm plus 0.05 percent total coated thickness zinc coating 120 grams per sqm as per is 277 in 240 mpa steel grade 5 to 7 microns epoxy primer on both side of the sheet and polyester top coat 15 to 18 microns using self drilling or self tapping screws complete ridges plain 500 to 600mm " "providing and fixing precoated galvanised iron profile sheets size shape and pitch of corrugation as approved by engineer in charge 0.50 mm plus 0.05 percent total coated thickness with zinc coating 120 grams per sqm as per is 277 in 240 mpa steel grade 5 to 7 microns epoxy primer on both side of the sheet and polyester top coat 15 to 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin charge. the sheet shall be fixed using self drilling or self tapping screws of size 5.5 x 55 mm with epdm seal complete upto any pitch in horizontal or vertical or curved surfaces excluding the cost of purlins rafters and trusses and including cutting to size and shape wherever required." providing and fixing of glass panes with putty and glazing clips in steel doors and windows all complete with 4mm thick glass panes etc. complete. supply of led tube light fittings .make c.g. or philips fixing of led tube light fittings including supply of all hardwares as required. led fitting will be supplied by contractor. make c.g. or philips supply of 48 sweep ceiling fan complete with down rod.clamp canopy etc. fixing of 48 sweep ceiling fan complete with down rod.clamp canopy etc.fan hardwares required for fixing for i.e. nut bolts clamp screws etc wiil be supplied by contractor. supply and fixing of stepped type electronic fan regulator on existing switch board. wiring for light point fan point exhaust fan point with 1.5 sqmm frls pvc insulated copper conductor single core cable in consield with modular switch modular plate suitable gi box and earthing the point with 1.5 sqmm frls pvc insulated copper conductor cable as required. supply of frls pvc insulated copper conducter single core cable of size 6 sqmm. make havells or kei or polycab or national wiring for circuit or submain wiring along with earth wire with the following sizes of frls pvc insulated copper conductor single core cable in consield or recessed medium class pvc conduit in concield as required 2 x 6 sqmm plus 1 x 6 sqmm earth wire. all the three colours should be red blue and green supply and fixing of utility db p or s 20a dp metal plug and socket distribution board grey make anchor or havells supply and installation of three phase industrial box with 32 amp 4 pole mcb and 5 pin top plug. make neptune or reputed make supply of frls pvc insulated copper conducter single core cable of size 10 sqmm. make havells or kei or polycab or national wiring for circuit or submain wiring along with earth wire with the following sizes of frls pvc insulated copper conductor single core cable in surface or recessed medium class pvc conduit in concield as required 4 x 10 sqmm + 1 x 10 sqmm earth wire.all the five colours should be red blue yellow black and green preparation of earth pit with supply of all materials including 3m long 3.64mm thick perforted gi tube with salt and charcol in alternate layer and brick chamber at the top with chequered plate 6mm thick as per is 3043 with latest. supply and laying 25mm x 5 mm gi strip at 0.5 meter below ground or wall including connection with electrode with db. supply of all hardware are in scope of contractor supply ans fixing of surface mounting vertical type 415 volts tpn mcb distribution board of sheet steel dust proctected duly power coated painted inclusive 200 amp tinned copper bus bar common neutral link earth bar din bar for mounting mcb with provision of 100 amp tpn mccb as incomer interconnection between incomer mccb and busbar. supply and fixing of 5 to 32 amp rating 240 or 415 volt mcb suitable as per load. supply and fixing of four pole 100 amp rating 415 volt 16 ka mccb . laying of 1.1kv grade pvc al.cable of size 2 or 3 or 3.5 or 4c 2.5 or 6 or 10 or 16 or 25 or 35 sq.mm in underground trench of 760mm deepx760mm wide in single tier formation including trench excavation and back filling with bricks 15brick or m and sand protection route marker. road or concreete or bolder cutting and finishing the road to its original shape are in the scope of the contractor. supply and fixing of street light on wall including supply of all necessaryu hardware for fixing of fitting on wall. supply and fixing of bulk head fitting on wall including supply of all necessaryu hardware for fixing of fitting on wall. supply installation and commissioning of exhaust fan of size 300 mm dia. this includes cutting of wall and finishing and supply of hardware like nut bolts etc. make crompton
  • View Tender
  • Document
  • Bid Support
13 Security Services
image image
Central Government/Public Sector
TRN :49054604 |  13 Jun, 2025
Tender Value : 70.50 Crore
 Kochi - Goa
Tender for tender for provision of cgsd (kochi) at willingdon island, kochi; 1 schedule a part - i (building & structure works)details of prepriced schedule is given in tender documents. 2 schedule a part-ii ( site clearence/development & earth works) details of prepriced schedule is given in tender documents. 3 schedule a part-iii (internal water supply) details of prepriced schedule is given in tender documents. 4 schedule a part-iv (internal electrification) details of prepriced schedule is given in tender documents. 5 schedule a part-v (fire fighting)details of prepriced schedule is given in tender documents. 6 schedule a part-vi (road/path/ hard standing/culvert)details of prepriced schedule is given in tender documents. 7 schedule a part-vii (external water supply) details of prepriced schedule is given in tender documents. 8 schedule a part-viii (external electrification) details of prepriced schedule is given in tender documents. 9 schedule a part-ix (sewage disposal) details of prepriced schedule is given in tender documents. 10 schedule a part-x (area drainage) details of prepriced schedule is given in tender documents. 11 schedule a part-xi (compound wall) details of prepriced schedule is given in tender documents. 12 schedule a part-xii (organic waste converter and smart energy meter) details of prepriced schedule is given in tender documents. 13 schedule a part -xiii (miscellanious items) note:- this schedule is not pre-priced by mes and the pre-priced rate indicated as rs 0.00 under col. e signifies this fact only. 14 internal water supply s & f for 15 mm dia bore cp two way bib cock with cp wall flange (make : jaquar model no. opp15041pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 15 s & f for 15 mm dia bore cp bib cock with cp wall flange (make : jaquar model no. opp15037pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 16 s & f for 20 mm bore concealed stop cock reqular brass body with spindle extnwith exposed part kit of concealed stop cock with fitting sleeve, operating lever & adjustable wall flange (compatible with ald-083cqt & ald-089cqt)(make : jaquar model no. ald 089 cqt/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 17 s & f for 25 mm dia bore concealed stop cock reqular brass body with spindle extn with flush cock & wall flange 25mm ceramic disc cartridge) with plain knob (make : jaquar model no. ald 081/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 18 s & f 20mm bore cp angular stop cock with cp wall flange (make : jaquar model no. cqt 23053 / eqvlt in kohler/grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 s & f for 100 mm overhead shower rose round shape single flow (abs body chrome plated with gray face plate (make : jaquar model no. 1989 with sha 479l300s / eqvlt in kohler/ ess ess) with shower arm ø20mm & 300mm long round shape with 90° bend for wall mounted showers with stainless steel connected to pipe complete all as specified and directed by engr-in-charge. 20 cooling appliancesdesign, supply, installation, testing and commissioning of invertor type floor mounted packaged ac units of specified capacities, combination of energy efficient inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include group controller also asrequired for controlling ac from a single point and timer option for load sharing of ac units complete all as specified and as directed by engineer - in - charge, of following capacities.note: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. (high side (machines))(outdoor unit) 21 a) 22 tr inverter package ac units 22 b) 16.5 tr inverter package ac unit 23 design, supply, installation, testing and commissioning of normal type floor mounted packaged ac units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include support works for outdoor units with necessary catwalk for service access complete all as specified and as directed by engineer - in - charge, of following capacitiesnote: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. low side (machines))(indoor unit) 24 a) 22 tr inverter package ac units 25 b) 16.5 tr inverter package ac unit 26 supply, installation and testing of refrigerant pipingwith necessary clamping (suction & discharge) hard/soft drawn copper tube of suitable sizes, with copper elbows, tees, tubular nitrile insulations etc as required complete all as specified and as directed by engineer - in - charge. 27 s & f control cabling b/w indoor & outdoor units 28 m & l refrigerant gas - r410a 29 supply, installation and testing of hard pvc drain piping. drain piping with tubular nitrile rubber insulation: complete in all respects, well clamped till drain points complete all as specified and as directed by engineer - in - charge. for all units 30 ductingsupply, fabrication, installation, testing of gi rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per is 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by engineer - in - charge. 31 a) using 0.63 mm (24 gauge) gi sheet 32 b) using 0.80 mm (22 gauge) gi sheet 33 c) using 1.00 mm (20 gauge) gi sheet 34 duct insulation & liningsupply and installation of acoustic insulation of ducts using 9mm open cell nitrile rubber, well adhesived, 150 - 180 kg/cm2 complete all as specified and as directed by engineer - in - charge. 35 supply, installation & testing of thermal insulation of ducts using 9mm closed cell nitrile rubber, well adhesived, 40-60 kg/cm2 complete all as specified and as directed by engineer - in - charge. 36 s & f canvas connection 37 air distribution productssupply and fixing of powder coated aluminium grills/ diffusers (supply/ return) complete all as specified and as directed by engineer - in - charge. 38 s & f collar dampers 39 supply and installation of fire dampers complete all as specified and as directed by engineer - in - charge. 40 supply, installation, testing and commissioning of heater bank plus humidistat arrangement complete all as specified and as directed by engineer - in - charge. 41 supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier hima 7 nhc, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, ac power supply with all connecting accessories complete all as specified and directed. 42 supply and fixrefrigerator, electric driven (single phase), 220 v,50 hz, capacity 195 litres, 3 star rated direct cool inverter, single door all as specified and directed by the engineer-in-charge. 43 supply and install, testing and commissioning of split type air conditioner 1.5 tr capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (cooling appliances- qty 4, air conditioning- qty 10) 44 supply and fix voltage stabilizer 3 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% 45 supply and fix voltage stabilizer 4 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% (cooling appliances-qty4, air conditioning- qty 10) 46 air conditioningsupply and install,testing & commissioning of split type air conditioner 2 tr capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 supply and fix voltage stabilizer 5 kva for automatic operation,single phase naturally air cooled indoor type, wall mounted type & designed for input variation between 170 v to 280 v with output voltage stabilized at230 v with accuracy of ± 2.5% 48 internal electrifications & f led mirror light 1 x 5w lumos ecco 1 feet make: luker or equivalent 49 s & f modular mcb dbox 3 pin socket with mcb sp 20 amp, 240 v including plastic enclosure as per manufacturer instruction fixed on wall surface complete for air conditioner all as specified and as directed. (make:-havells, model-dhdmcsn0251016 or equivalent) 50 supply and fix air circulator of 600 mm sweep ac single phase. 230v, 1440 rpm complete all as specified and as directed. (make: havells model, turbo force wall or equivalent) 51 s & fvertical triple pole & neutral (vtpn), double door, 16-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 52 s & fvertical triple pole & neutral (vtpn), double door, 4-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 53 m & l for flame proofmcb distribution board spn 12 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb -10 nos as outgoingcomplete all as specified and as directed. 54 m & l for flame proofmcb distribution board spn 8 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb- 6 nos as outgoingcomplete all as specified and as directed. 55 supply and fix engage light with green & red led complete all as specified and as directed 56 supply and fix of cs mounted high intensity led search light, long range, manually swivel in all direction, 250 w, minimum range 700 meters, single, led efficiency> 140 lm/w, pf> 0.95, cct 5500k - 6500k, optical grade pmma/pc lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti uv, narrow beam 5 degree, die cast lm6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree c, input volt 100-300 vac, 50 hz, pf >0.95, ip-66, confirming to lm79/ lm80 and type tested as per is: 10322/ is: 13383, bis approved and govt lab tested for lux intensity. the search light is completed with manual revolving cs stand d20cm x h15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. model no. cs-lrfll-25pc25 of kalin make or equivalent 57 supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, enystar emptyenclosures, ip-65, weatherproof, corrosion free, halogen and silicon free, frame retardant with opaque lid size-[276 x 546 x 186]mm and transparent hinged lid, completed all as specified and directed. 58 m & l for tv socket module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 59 m & l for telephone jack with module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 60 supply and lay coaxial cable for tv cabledrawn through conduit 61 s & f flame proof exhaust fan 300 mm sweep, single phase, 1440 rpm complete all as specified and as directed. 62 fire fightingsupply and fix foot valve conforming to is 4038, 100 mmdia. 63 supply and fix foot valve conforming to is 4038, 150 mmdia. 64 supply and fix cast iron air valves with single air outlets, conforming to is 14845 of size 100 mm dia bore and fixing up in cast iron water supply mains of size 100 mm dia. 65 s & f sprinkler flexible drop pipe 1 mtr long. 66 s & f sprinkler rossette 25 mm dia. 67 supply and installation, testing and commissioning of analog addressable type active loop repeater (loop power/external power) fire terminal with inbuit turbo isolator, backlit lcd display 6x40 characters display, having controls for reset, mute, accept, silence alarms and self test, with programmable free keys and duly approved byen54/lpcb/vds/fm make: siemens/notifier/bosch 68 m & l for low smoke zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to bs7629-i, bs6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier type lt53 outer sheath confirming to bs 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 staircase signage down of make bajaj cat part no. 111499 model no. dsdwbb 3w double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 s & f wall mounted led emergency exit signage luminaire lit up using regular mains supply comes with a unique rechargeable ni-cd battery capable of emergency back up upto 05 hours(cat no. 220211 make bajaj or equivalent to cg/havells. 71 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board , made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and comprising of the following:- make of mccb/mcb -mds/legrand/l&t/hegger (main fire fighting panel)incoming(i) mccb 4 pole 160 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release - 01 no.(ii) voltmeter digital type 0-500 volts range flush type with selector switch- 01 no(iii) aluminium bus bar tpn - 200 amps- 1setoutgoing(i) mccb 3 pole 125 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release- 01 no.(iii) mcb tpn 32 amp -02 nos(iv) 80 hp s/d starter- 01 nos(v) dol starter 7.5 hp- 01 nos(vi) motor protection relay32-88 amps- 1 no. (vii) motor protection relay2-5.5 amps- 1 no. (viii) on/off/trip indication lamps, 220 v ac- 6 nos.(ix) start/stop push button, 2 no. (x) phase indicating lamps ryb for incoming and each outgoing connection.(xi) digital type ammeter 0- 150 amps with selector switch and ct coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 m & l for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per is-10221.the coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per is specification 73 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board, made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and & directedby engr-in-charge comprising of the following :– ( booster terrace pump panel)incoming:-(a) incoming mccb 40 a 25 ka, 4 pole- 01 no.(b) busbar tpn of size 100 apms - 1 setoutgoings:-(a) mcb 3 pole tpn 32 amps,10 ka-2 nos.(b)dol starter for 7.5 hp pump set-1 nos.(c) ammeter class-1, digital panel mounting type 96mmx96mm l & t cat no wds301fca00 including ct 50x5 amps 3 nos & selector switch-4 nos(d) voltmeter class- 1, digital panel mounting type 96mmx96mm l&t cat no.wds301fev00 & selector switch - 1 no.(e) led type indicator lamp 1 set (set of three for r,y,b)(f) mini protecrionrelay 4-11 amp - 1 nos. 74 fire extinguisher mechanical foam type trolly mouted of 9 liters capacity. ceasefire 9 litrs fire extinguisher afff foam type, external cartridge type, pressure guage gross weight 14.6 kg, empty weight5.6 kg, can height 611 mm, diameter 175 mm, discharge time less than 60 secs controllable discharge mechanism, minimum 6 mtrs, applicable on class a, b, can construction deep down & co2 mig welded valve construction: forging & machining, internal coating of can: epoxy powder coating, external coating of can: epoxy poyster powder coating sheet metal thickness 2.0mm,1 year warranty. make cease fire or equivalent. (pol store) 75 supply, installation,testing & commissioning of carbon dioxide (co2) type fire extinguisher of 4.5 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 76 supply, installation,testing & commissioning ofdry chemical powder (abc) stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 77 supply, installation,testing & commissioning of water mist high pressure stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 78 supply and installation at approved location approved make fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & showel etc, complete. 79 special equipments for storesdesign, manufacture, supply, installation, testing and commissioning of automated storage and retrieval system with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. automated storage and retrieval system shall consist of computer controlled & plc stacker crane driven system for automatically placing & retrieving materials from defined storage locations. the crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 kg (max) complete all as specified and directed by the engineer-in-charge. technical data for design of heavy duty asrs:-(a) dimensions:-height:10 mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)storage capacity:-pallet size: 1300 (w) x 1200(d) x 1250 (h) in mmpallet nos.: 480pallet load capacity: 1125 kgtotal capacity: 540 tons(c) stacker crane: single mast automated stacker crane for handling pallet, size 1300mm(w) x 1200mm (d) x 1250mm (h) and pay load (including pallet self weight) of 1125 kg max. the stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. stacker crane will be mounted on single rail at the bottom to traverse the length of the storage system. a single top rail mounted on the racking system shall also support it.general technical parameters of stacker crane:technical parameters/type- single mast(i) operation mode (networking)- on-line automatic / single automatic (ground/boarding) /manual operation (boarding) / maintenance (ii) communication means- wireless 80 (iii) power supply mode- 380 to 415 v, 50 hz, three phase five wire (iv) addressing mode- horizontal and verticle operation: photo electrical sensor + bar code scanners(v) positioning / reduction accuracy (mm) level- lifting ± 3 - 5, fork : ± 3(vi) fork unit- 1 double deep fork(vii) load unit- ms pallet (viii) total height- 10 mtr(ix) the normal lifting speed (m/min) - 10 mpm(x) the normal running speed (m/min) - 65 mpm(xi) rated load- 1125 kg(xii) receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- conveyor(d) pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 kg at height up to the last loading level in the racking system. it should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.pallet details:-(i) dimensions - 1300mm(w) x 1200mm(d)(ii) pallet height- 1250 mm(e) racking system :- two aisle having two row racking system each with 05 verticle levels for storage of material. racking for double deep type storage of 480 pallet of size 1300mm(w) x 1200mm (d) x 1250mm (h). loaded pallet weight: pay load with pallet 1125 kg max. system details:-working aisle -01 nos. (double deep)store rack -24 nos./rowtotal rack in 1 aisle-24 (left) + 24 (right)= 48 nos.no. of level- 5 nos/racktotal pallet-48 x 5 x 2 = 480 nos.load capacity- 1125 kg/levelsingle mast stacker crane-01 no. 81 (f)aisle equipment:-this will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. the mechanical aisle equipment of bottom rail shall consist of i beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. top rail shall be mounted on the racking. the electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) details of rack members:-the racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) loading- unloading station/ conveyor(i) pallet load 1125 kg max.(ii) bearing- skf equivalent make(iii) motor- seimens/sew euro drive/nord sew/ bonfiglioli or equivalent(iv) gear box- bonfiglioli make or equivalent(v) v.f.d.- yashkawa make or equivalent(j) all steel surface shall be powder coated finish with 8 tank treatment process.(k) maintenence: the annual maintenence of complete asrs system duyring the defect liability period of two years shall be included in the rate quoted for the system and the amc contract duly signed with the manufacturer of the asrs system shall be submitted at the time of handling over the system. the amc shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountnote- 1mechanical safety provision (i) end of aisle shock absorbers / bumpers for stacker crane.(ii) end of travel buffer for the lifting crane.(iii) safety catches on lifting carriage.(iv) anti-tilt mechanism for the stacker crane.(v) continuous rail cleaning brush for floor rail.(vi) adjustable rail clamp to ensure alignment. 82 (vii) resilient rubber pads on adjustable clamps for vibration dampening.(viii) profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. note - 2 electrical safety provision (i) there shall be emergency stop push button at all panels and stations.(ii) optical light beam amd mechanical safety sensor to stop the operation in case of improper storage or obstruction in the operator window either internal or external reasons like operator hand or material placed at edge of the tray.(iii) back up circuitry for proper system operation.(iv) an electromagnetic brake shall be used to avoid the slippage of the hoist.(v) stopper shall be provided for the maintenance door.(vi) load cells shall be provided for the over weight of tray.(vii) automatic door shall be provided for operator safety while machine in operating condition.note - 3 physical safety provision (i) the asrs system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. height of the fencing should be minimum 2.0 meter.(ii) one no. of electromagnetic aisle access door shall be provided. it should cover the complete length of the system on one side.(iii) a manual locking system to restrict the movement of unauthorised personnel shall be provided.note: design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. item no. 13.070 below shall be compatible with this item/ system and both should be integratedmake of asr system:armstrong ltd/ godrej koerber/ kardex india storage solutions pvt ltd/ daifuku india pvt ltd/ addverb technologies ltd/ craftsman automation ltd/ tech-mark 83 supply, installation, testing and commissioning of advance inventory management system with computer hardware with compatible inventory software complete all as specified and directed by the engineer-in-charge. technical specification of the system(i) system height : 6400 (±100) mm(ii) system width : 3150 (±100) mm(iii) system depth : 2300 (±100) mm(iv) system base : 7.24 sq.mtr(v) tray int. size: 300 (h) x 2450(w) x 500 (d) in mm(vi) tray dead weight - 57 kg (approx.)(vii) per tray weight capacity - 300 kgtechnical specification of the system:-(viii) tray quantity : 32 nos.(ix) usable net load - 9.6 ton(x) storage surface area per system - 39.2 sq mtr(xi) door - automatic(xii) power consumption - 3.7 kw(xiii) power supply - 440v, 50/60 hz, 3 phase(xiv) motor 3 phase 1440 rpm - seimens make or equivalent(xv) chain - diamond makeor equivalent(xvi) bearing - skf/ntn make or equivalent(xvii) external cladding - epoxy powder coatedsafety features:1. photo curtain at access port, 2. motor protection relays, 3. limit switch at door, 4. single phase preventer,5. switch mode power supply, 6. 15 min battery backup for plc, 7. noise less than 60db, 8. emergency stop various safety alertsnote: the system and software provided under this item shall be of same make as for item 13.069 or a compatible system and software as recommended by the chosen manufacturer of asr system. this system shall be integrated with asr system. 84 supply, installation and testing of car traffic boom barrier 6 mtr suitable to working on power supply 230 volt, 50 hz, 24v dc electric motor, adjustable with cams, operating ambient temperature from -20 to +55 degree celsius, uses cycle 2000/day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 nm open/close time 2 to 4 sec complete all as specified and as directed by engineer-in- charge.make: faac/parkilo/skidata/bft 85 external water supplysupply and fix foot valve conforming to is,100 mm dia complete all as specified and directed. 86 supply and fix cast iron air release valve with 100 mm bore and two outlets as per is:14845 complete all as specified and directed. 87 supply, installing, testing and commissioning of electrically driven horizontal centrifugal pump set 9.0 lps at 50 meter head as per specification, motor tefc type, 2880 rpm, 415 v, 50 hz, 3 phase, class f insulation, ip 55 protection, starting on suitable star delta starter. the pump shall be horizontal, end suction, top discharge. the pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on rcc (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 lpm at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, pvc insulated copper cable connection from starter to the motor terminals all as specified and directed by the engineer-in-charge.(01 no. working + 01 no stand by)make:- kirloskar brothers/crompton or equivalent. 88 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.0 mm thick crca sheet, cpri approved having, ip 43, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply, bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2.0 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: lt panel for pump house. the lt panel comprising of the following:- 89 incoming:-mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, breaking capacity 36 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 01 sets(b) digital multi function meter - 01 no.(c) cts - 100/5a, cl-1, 15 va - 01 set(d) horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 350 amps for phase and 350 amp for the neutral baroutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 16 ka- 02 no. ics =100% icu -2 nos.(b) mcb, tpn 40 amp, 415 volt, c curve - 02 nos.(c) star delta starter 12.5 hp, 3 phase, 415 volt- 02 nos.(d ) digital ammeter - 2nos.(e) single phase preventer - 2 nos. 90 m & l valve chamber of internal size 0.90m x 0.90m x 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick pcc in 1:4:8 type d2 foundation, brick work in cm 1:6, 15 mm thick rendering in cm 1:4 to internal surfaces and external surfaces upto 150mm depth below gl, pcc 1:3:6 type c1 as in coping, cover with two nos. of hinges and one no. handle made out of ms round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. note:- the quoted rate shall include all earthwork and connected items. 91 m & l earthing complete with galvanized steel earth plate electrode of size 600mmx600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal gl and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in electrical plate no. 3 connecting to earthing test point, including necessary earth work in any type of soil, pcc earth chamber made in pcc 1:3:6 type c1 (using 20mm graded aggregate), common salt, charcoal, ci funnel, earth pit cover in rcc 1:2:4 type b1 (using 20mm graded aggregates), with 8mm ctd bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 external electrificationm & l for ht/lt ms cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm ms strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of pcc 1:4:8 type d-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.note: ht route indicator shall be painted as under:-(i) for ht 11 kv cables - “brown”(ii) for lt cables - “blue” 93 supply and fix compact air insulated bus bar trunking system with copper busbar 1600 amps, 50 ka breaking capacity, ip54 protection, bus duct 1600 a, 415 volt, capacity sandwich type, set rybn complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to lt panel board complete all as specified and directed. 94 supply, install, testing and commissioning of distribution transformer step-down level 2 (previously ee level 3 before amendment no 4 to is 1180), 11kv0.433kv, three phase complying withis: 1180/iec-76(part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 hz system of capacity 800 kva, oil immersed naturally cooled delta connected on ht side and star connected on lt side, vector group dyn11, provided with off load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & half load (50 %) shall not be exceeded 5838 watts & 2147 wattsrespectively as per grlha rating, percentage impedance: 4.5%. losses and impedance are subjected to tolerance as specified in is 1180. the transformers should be supplied with first filling of oil confirming to is 335. the transformer should have both side cable end box with neutral brought out complete all as directed by engineer - in -charge, and installation of transformer shall be carried out as per is-10028and comprising with the following standard fittings/technical specifications:-(a) lifting lug for transformer and tank.(b) earthing terminal rating and diagram plate.(c) air release device.(d) oil filling inlet pipe with plug.(e) drain outlet pipe with brass gate valve.(f) conservator tank with oil level indicator(g) silica jel breather(j) first fill of oil upto level including conservator tank with fresh new oil conforming to is335.(k) type of connection delta/star(l) type of cooling: oil and natural air.(m) vector group: dyn 11.(n) temperature rise over an ambient of 50 °c maximum.(o) cable end box on both side for ht/lt cables of suitable size.(p) provision of thermometer with pocket.(q) provision of oil and winding temperature gauge. 95 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: the lt panel comprising of the following:- main lt panelhorizontal copper busbar for 3 phase, 440 volts, 50 hz, 4 wire system of rating 1600 amps for phases and 1600 amps for neutral. 96 incoming:-incomer:-acb 4 pole, 415 v, 50 ka with thermal magnetic release (manual draw out type) of capacity 1250 ampmetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 1600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, ics =100% icu, breaking capacity 35 ka, ics =100% icu- 02 no. (for dg amf panel & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for apfc panel & fpb 2 near bulk store) (c) mccb, thermal magnetic release, 4 pole, 415 volts, 320/315 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for fpb 1 near adm block) (d) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for existing load)(e) mccb, thermal magnetic release, 4 pole, 415 volts,125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for fpb 3 near auction disposal store)(f) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for mt complex, watch tower no 2, guard room)(g) digital ammeter with suitable ct for each outgoing 97 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (near admn bldg) 98 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral.incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for 2nd floor & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for 1st floor)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for g floor)( d) digital ammeter with suitable ct for each outgoing 99 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.2 (near bulk store) horizontal aluminium busbar for 3 phase,440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral. 100 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for equipment load & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for bulk store)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for watch tower no. 1)( d) digital ammeter with suitable ct for each outgoing 101 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.3 (near auction disposal store) 102 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 200 amps for phases and 200 amps for neutral.incoming:-(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, breaking capacity 25 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 200/5a, cl-1,15 va - 01 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, ics =100% icu breaking capacity 25 ka- 02 no. (for store dispatch complex & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for pol store, auction disposal store, covered hard standing)(c) digital ammeter with suitable ct for each outgoing 103 supply and fixing poly carbonate street light junction boxes ip 66/67 weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitablecable connecting terminals, cable lugs, including provn of one no. mcb sp 6 amps for operating the street light fittings, suitable cable glands as per site requirement, all as directed by the engineer-in-charge. 104 s & f street light bracket made out of gi tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary ms clamp-02 nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core frlsinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.note: phase should be red/yellow/blue, neutral should be black and earthing wire should be green in colour. two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 supply and fixing of led ?ood light, 200w, watt 230 v, ac outdoor type with thermal management in multiple optics and equipped with ip66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power leds and secondary lenses with ip protection incl system efficiency >110/120lpw 10kv spd included energy saving, environmental friendly and general purpose lighting complete all as specified and directed engineer-in-charge. make : make : crompton/philips/wipro 106 supply and fix high mast panel outdoor type, suitable to take load up to 6 kw, conforms to is/iec 60947-4-1, provided with protection degree ip 54, extended wide band (150 vac - 300 vac) coil, frls (fire retardant low smoke) internal wiring, in-built short-circuit protection, class h insulation, 3 phase 415 volts ac with the following accessories:phase : 3 phase, 415 voltsmax load capacity : 6 kwtimer type: astronomicalcontactor rating : 32 a tpmcb rating : 63 a tpnmake : crompton/ philips/wipro 107 supply and laying dwc (double wall corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming is 16205 (part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm st light cable & 16 sqmm cable) 108 aviation obstruction lightsupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one no.10 a, mcb, spn 230 v with fixed enclosure complete all as specified and directed by engineer-in-charge.make:- bajaj cat no bgav 302 led or equivalent in philips/crompton/surya 109 incineratorsupply, fixing and testing of solid waste electric incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°c, stainless steel stack for longevity, fitted with a velocity cowl as standard, chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree celsius mounted on foundation as recommended by oem including electrical control panel with suitable size mccb, relays & contactor recommended by oem complete all as complete all as specified and directed.note:(a) the electrical works including electrical lt panel, internal wiring of the lt panel, suitable size copper wires from panel to solid waste electric incinerator as recommended by oem to operate the solid waste electric incinerator of capacity 100 kg/hr to make solid waste electric incinerator operational is deemed to be included in the rate quoted. (b) all electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed there under and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solid waste electric incinerator of capacity 100 kg/hr all as mentioned above and which is not mentioned or included in this schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) foundation/plinth/base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the solid waste electric incinerator and height of plinth shall not be less than 0.5 m 110 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, breaking capacity 36 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 electric sirensupply and fixing sirens electronic type horizontal double mounting three phase 400/440v, 2800 rpm 50 c/s flame proof, audible range 3.5 km, 2 hp, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 supply and fix advance sirens controller electronic type suitable to operate on 3 phase, 415 volt ac 50 hzcomplete all as specified and directed. 113 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 25 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 solar power plantdesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (on-grid) on roof top of existing bldg of capacity 150 kwp, power evacuation at 415 volt 3 phase system all as per guidelines/norms issued by mnre & indian metrological deptt approved solar radiation data viz direct normal irradiance, global horizontal radiance etc complete comprising with the following solar photo voltaic plant.(a) design, supply, installation, testing and commissioning of solar pv modules capable of generating 150 kwp (ac) electricity at 415 volt 3 phase system. these solar pv modules of 540 watt perc with a modular efficiency of 17-19.84% as per iec and mnre standard or as per approved design parameters with poly/multi crystalline silicon solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to iec 61215, iec 61730, iec 61701. solar pv module should be of approved indian brand only and qualify under the domestic content requirement (dcr) norms of nvvn/seci and testing requirement fixed by mnre. the pv modules shall be warranted for a period of minimum 25 years, solar pv modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of ten years and 80% at the end of twenty five years. each solar pv module must use rf identification tag. the following information must be mentioned in the rfid used in each module:name of manufacture of pv module, name of manufacturer of solar cell, month & year of manufacturer (for solar cell and module), country of origin (lt is mandatory to use cells and modules manufactured in india). i-v curve of the module, wattage, lm, v-m, & ff for the module, unique serial no & model no of the module, date & year of iec pv qualification certificate, name of the test lab issued iec certificate. the pv modules used in the solar power projects must qualify to the latest edition of the following international electro technical commission (iec) p module qualification test or equivalent bis standards. the pv module must be tested and approved by one of the iec authorized test centres. 115 (b) material and labour for module mounting structure (mms) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 kmph wind speed all as per approved design parameters as per mnre standards and to match with the existing site conditions. necessary roof treatment to avoid any seepage in future shall be done by the contractor and the amount included in the rate quoted. the roof tiles shall be dismantled and refixed back in original position. structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) supply, laying & testing of dc cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant is, weather proof uv resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of spv modules to array junction box including suitable size of cable lugs, male & female mc4 connectors & joints etc.(d) supply, installation test and commissioning of protection devices mccb 400 a, isolator and three phase 4 wire lt energy meter, array junction boxes having rating 150 kwp with over voltage protection and surge protection.(e) supply, installation, test and commissioning of grid tie solar power conditioning unit / inverter of minimum capacity 150 kwp(dc to ac 415 v in three phase system) all as per approved design parameters & capable of generating output voltage 415 v ac at rated load condition with efficiency not less than 98 %, conforming to iec 600682-2 nde standards with power reduction, lvrt with protections for anti-islanding, ground fault monitoring, grid monitoring, ac & dc over voltage and under voltage protection, ac & dc short circuit lover current protection and dc reverse polarity protection, graphic display etc. all as specified and as directed.(f) material and labour for earthing for lightning protection for spv modules etc as per ie rule, mnre guide line & bis all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including gl strip 32x6mm size protected with gl medium grade pipe 40mm dia for earth electrode up to test point by means of gi nuts, bolts, check nuts and washers including earth work excavation, pcc (1:3:6) type cl pit and rcc cover ( 1:2:4) type bl and funnel, with necessary charcoal, salt etc complete. 116 (g) supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for spv modules lightning protection upto interconnection between roof top la to ground earthing system. (h) ac cable: supply and laying of 150 sqmm lt xlpe insulated, screened pvc bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to is 150 sqmm x 3.5core as per site requirement.note (i) :-(a) before quoting the bid, contractor or his authorised engineer/consultant must visit the proposed site to study the site condition.(b) before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to accepting officer for approval.note(ii):-(a) the mechanical structures, electrical works and overall workmanship of the grid solar power plant must be warrented for a minimum of 5 years.(b) all mechanical, electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed thereunder and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 kwp (ac) all as mentioned above and which is not mentioned or included in this schedule a but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) contractor shall provide adequate spares/items required for minimum period of 1 year maintenance including dc & ac items under scope of work.note (iii) : design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. 117 dg setsupplying, installing, testing and commissioning, factory assembled silentdiesel engine driven generator set, fully wired alternator ac to give an out put of 400 kva continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 hzsupply, 1500 rpm, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, pcc foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a)diesel engine: liquid cooled turbo charged with after cooler to deliver suitable bhp at 1500 rpm under ntp conditions of bs 5514 and conforming to is 10001/ 10002, din 6271 & iso 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class a1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) radiator with blower fan or heat exchanger with guard.(b) pipe coupling for engine cooling system piping.(c ) corrosion inhibitor coolant(d) paper element filters(i) fuel filter(ii) lube oil filter(iii) by pass(e) fly wheel housing and fly wheel to suit alternator.(f) engine bearing mechanism in fly wheel housing.(g) shut off coil with safeties for llop/hwt/over speed.(h) dry type air cleaners and vacuum indicators.(j) residential silencers.(k) stainless steel exhaust flexible bellows. 118 (l) motor driven priming pump.(m) battery charging alternator.(n) exhaust piping made out of stic c class, ms pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(o) mineral wool insulation 2 inch thick suitable for 400 degree celsius temperature cladded with aluminium sheet o30 gauge for the entire length of exhaust pipe.(p) first fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) interconnecting copper cabling of adequate capacity batteries control.(r ) fuel pipe class stic 1 /1.5 /2 dia - 01 lot(s) self starter 12 volts dc.(t) electric operated electronic governor.(u) fuel injection pump.(v) no of cylinders - 12 no vee(w) electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24v battery. (ii) water temperature.(iii) lubricating oil pressure.(iv) engine speed -1500rpm(v) engine hours(vi) frequency.(vii) voltage.(w) safety control (trip and indication).(i) high water temperature(ii) low lube oil temperature(iii) overspeed stop 119 (x) base frame: sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith avm pads.(y) battery:-24 volts(2x12v battery) dc, 180ah, maintenance free battery conforming to is:14257 with leads & terminals (make- excide/amron).(z) fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick hr/ms sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) isolator panel with 250 amp mccb(ab) auto logic panel for automatic stat(b) alternator: alternator suitable rated for 400 kva, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 hz at 1500 rpm, self excited and self regulated with avr brushless, screen protected, drip proof , insulation class-h, ip -23, voltage regulationgrade - vg 3 self ventilated and conforming to bs: 5000 / is: 4722 suitable for engine as mentioned here-in before, conformig to is: 13364(part-1)make: koel green / stampford/crompten/kirloskar/greaves(c) acoustic enclosure:- m & l for acoustic enclosure for the above 400 kva dg set to reduce noise level to 75 db measured at 1.0 meter distance for audible frequencies as per guide of central pollution control board andmanufacturers specification and comprising of following from authorised goems of gen set manufacturers specified :-(i) sound insulation : 100mm thick rock wool (density 64 kg/cum).(ii) outer body : 1.6mm thick crca(iii) door : 1.6mm thick crca(iv) base frame : ismc 300(v) inside illumination : 1 no.- 1 x 18 watt led fitting of make phillips/ bajaj/ crompton.(d) amf control panel:- factory fabricated cubicle type, free standing, floor mounted, indoor type, ip-43, amf control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick crca sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (e) amf control circuit with 4 pole mccb 630 amps - 2 nos, with ultimate breaking capacity icu-50 ka at 415 volts and microprocessor release conforming to iec 60947 part-i with breaking capacity ics=icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 nos. for main supply & dg set supply with hrc back up fuse complete with all dc control relays/ line voltage monitor (lvm) as per oem specifications incorporating motorised stored energy operating engine start, stop, three attempt starting facility and failure to start etc.(f) digital load manager : three phase 4 wire indicating v,i,pf, kva, kw, f of enercon make with serial communication port model no.em6400 with class 1.0 accuracy meter or equivalent make suitable rating of ct per phase- one no.(iii) indication lamp r, y, b with 3 nos. of 2a hrc fuses-10 sets.(iv) bottom gland plate for incoming and outgoing cables.(v) circuit diagram plate.note :- dg set should be as per cpcb -4 latest norm wef 01 july 2023 of national clean air programme (nacp) act 1981. 121 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (dg panel ) 122 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 800/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for package ac bulk store & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for pump house & fire pump)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 80 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for incianator)(d) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 07 no. (for terrace pump 1, terrace pump 2, power house, high mast 1, high mast 2, street light)(e) digital ammeter with suitable ct for each outgoing(f) astro time switch for 3 phase 20a- 1 no(g) 3 phase power contactor 20 amps, with 230 coil 123 sewage disposalm & l for laying of dwcpe sewage pipes line 200 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 m & l for laying of dwcpe sewage pipes line 150 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 compound walls & f concertina coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm gi wire for securing, coil with fish hook bars, incl necessary welding to ms sections etc all as specified and directed. 126 green building norms(griha concept)supply and install organic waste converter fully automatic having capacity 50kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-type of machine: fulley automatic in-vessel compostercomposting method: 24 hrs. micro-organisms-based compostingmachine type of microganism used: heat resistant thermophilic bacteria final output: dry organic soil conditioner/soil supplementscycle time: 24hrs volume reduction in 24hrs: 80-85% internal tank: stainless steel type main agitator shaft: stainless steel type input voltage: 415vspecial features: vfd as standard across all models, touchscreen standards daily waste processing: 150kgs rated capacity: 7kwpower consumption (kwh par cycle): 13-15length: 1650, width: 850,height: 1455 127 supply, installation, testing and commissioning three phase energy meter with the following specifications: microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (nb-iot) communication that allows it to interact with the head end system (hes) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 volts, 50 hz of range 10-100 amps, complying to is16444:2015 (reaffrimed 2020) and conforming to is 3779 with led display and parameters like voltage, current, frequency, power, power factor, kwh/kva, default in built dual source, inbuilt long range (lorawan) communication suitable for outdoor lora data accumulator and also compatible for prepaid and postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to erp complete with 5 years warranty.note:(a) the contractor would be responsible for removing the existing meter, noting down the reading and depositing it with the mes age e/m store complete all as specified & directed.(b) the energy meter to be capable of running in both prepaid and postpaid mode.(c) the meters to carry 5 year warranty. (for entire system) 128 supplying, fixing, commissioning and testing of configuration of cloud hosted multi user web based software with following modules:(i) head end system (hes): to acquire meter data automatically from dcu sand monitor parameters acquired from meters.(ii) meter data management modulethe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. the system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters cumulative energy. cumulative apparent energy (as applicable), power, current, voltage, power factor and frequency(b) monthly billing survey data for cumulative energy and max demand(iii) billing module: the billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. the billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. it would allow postpaid and prepaid functionality as required.(iv) occupation and vacation module: the system would support occupation/vacation based on the unit catagories. the system would support automatic data capture on occupation and vacation events.(v) website: there would be a dedicated website forage/ge and bso team to view all the data and information alongwith customer portal for use of customer. the designated users in mes would have the admin access to the application. the mes staff would also have the access to the key information on mobile app (androiandios based) for admin use complete all as specified and directed.(vi) customer module: the system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. there shall be consumer app (android and ios based) also to log in and view their own energy/billing data and recharge facility.(vii) communication module :the system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) meter master data: the system would support meter data repository. the system would support meter replacement process.(ix) excel export: the system would support export of metering and billing data in excel and pdf format.(x) energy accounting module: the system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) prepayment/recharging facility:the system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. the system should allow online/digital recharging through consumer app (androidand iosbased) and web portal. the configuration and necessary arrangement for payment gateway and e-mro facility shall be deemed to be included in the quoted rate. the system should sendconnect/disconnect command on the basis of available credit.low credit alarm: the system will give an alarm over the consumer app and sms to the registered mobile number in case the credit in the meter goes down be low apredefined limit.emergency credit: the meter will work even when the credit falls down to zero to prevent disconnection. this limit shall be configurable. the system should support happy hours inorder to prevent disconnection in non working hours and on holidays. the happy hours should be configurable complete all as specified and directed. 130 supply, installation, testing and commissioning of dcus/gateways and the arrangement of sim cards or internet to enable reliable medium for two-way communication between smart meter & hes. the data acquisition (push/pull) frequency shall be, configurable. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. it shall have provision for the cellular, wifi and ethernet communication for the backhaul to hes. it shall be capable to handle data of minimum 1000 nos. of any type of smart meter (1ph/3ph).it shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. communication of the nearest meters with other meters shall be established through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. the equipment shall be weather proof and dust proof (minimum rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 hosting gprs (4g) charges for gateway for five years from the date of completion f including 2 years waranty and 2 years maintinance after warranty) make:-airtel/jio/vodafone 132 supply and installation of digital water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 supply and installation of digital water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 arboriculturem & l for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 all as per item no 13.121 above but pit size 60cm x 60cm x 60cm 136 supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 supplying and planting flower plants(champa/ hybrid hibiscus/ hybrid west indian jasmine/ hybrid plumeria white plant/ panama yellow plant/ oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 supplying and planting song of india flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 supply and planting mexican grass including providing manure as directed. 144 pile foundationboring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.note:- the quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. nothing extra shall be paid on this account. 145 boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using dmc method (direct mud circulation)and getting out & disposal of spoil to any distance outside of md land , complete all as specified and as directedby the engineerin charge 146 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in cast in situ dmc bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 149 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 150 all as per item no 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 m & l for providing pcc (1:4:8) type d-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 m & l for carrying out non destructive integrity test all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 m & l for carrying out initial load test (vertical load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 155 m & l for carrying out initial (lateral load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 156 m & l for carrying out initial load test ( pull outtest) of cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 157 m & l for carrying out routine load test (vertical load)all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 158 testing of piles (initial load test) for 450mm dia cast in situ bored piles all as per is including removing the testing equipments from the site after testing is completed all asspecified and as directed
  • View Tender
  • Document
  • Bid Support
14 Power Plant
image image
corporations/Associations/Others
TRN :49056804 |  23 May, 2025
Tender Value : 18.27 Lacs
 Prayagraj - Uttar Pradesh
Tender for tender for annual civil & electrical m&r work for residential building situated at 20-clive road hydel colony, prayagraj - earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. for all kinds of soil. 2 supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 3 surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. for all kinds of soil. 4 excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 5 providing and laying in position cement concrete of grade 1:1½:3 (1 cement: 1½ coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - all work up to plinth level : 6 providing and laying in position cement concrete of grade1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - all work up to plinth level : 7 providing and laying in position cement concrete of grade 1:5:10 (1 cement : 5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - all work up to plinth level : 8 providing and laying cement concrete 1:1½:3 (1 cement: 1½ coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 9 providing and fixing up to floor five level precast cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources) string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering complete. 10 providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 11 extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. 12 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-iii) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 13 providing and laying in positiongrade 1:1.5:3 (1 cement : 1.5 coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level : 14 providing and laying in positiongrade 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level : 15 reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 16 reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 17 centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete 18 centering and shuttering including strutting, propping etc. and removal of form for walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 19 centering and shuttering including strutting, propping etc. and removal of form forsuspended floors, roofs, landings, balconies and access platform 20 centering and shuttering including strutting, propping etc. and removal of form for shelves (cast in situ) 21 centering and shuttering including strutting, propping etc. and removal of form for lintels, beams, plinth beams, girders, bressumers and cantilevers 22 centering and shuttering including strutting, propping etc. and removal of form for columns, pillars, piers, abutments, posts and struts 23 centering and shuttering including strutting, propping etc. and removal of form for stairs, (excluding landings) except spiral-staircases 24 centering and shuttering including strutting, propping etc. and removal of form for spiral staircases (including landing) 25 centering and shuttering including strutting, propping etc. and removal of form for small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 26 centering and shuttering including strutting, propping etc. and removal of form for small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like 27 centering and shuttering including strutting, propping etc. and removal of form for weather shade, chajjas, corbels etc., including edges 28 centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 29 centering and shuttering including strutting, propping etc. and removal of form for lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 30 mild steel and medium tensile steel bars for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 31 mild steel and medium tensile steel bars for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 32 smooth finishing of the exposed surface of r.c.c. work with 6 mm thick cement mortar 1:3 (1 cement : 3 fine sand). 33 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 34 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in cement mortar 1:6 (1 cement : 6 coarse sand) 35 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in cement mortar 1:6 (1 cement : 6 coarse sand) 36 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand) 37 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. cement mortar 1:4 (1 cement :4 coarse sand) 38 providing and fixing 18 mm thick granite stone slab of colour black, cherry/ruby red gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels (area of slab over 0.50 sqm) 39 providing edge moulding to 18 mm thick granite workcounters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer-in-charge. 40 extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 41 providing and fixing plywood 4 mm thick, one side decorative veneer conforming to is: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : 42 providing and fixing 4mm thick coir veneer board, isi marked is : 14842, plain lining with necessary screws, priming coat on unexposed surface etc., complete. 43 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 44 providing second class teak wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 45 providing and fixing 2nd class teak wood size 50x12 mm moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 46 providing and fixing second class teak wood panelled or panelled and glazed 30 mm thick shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of engineer-in-charge. (note:- butt hingesand necessary screwsshall be paid separately) 47 providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 48 providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with isi, is : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 49 providing and fixing30mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with isi marked m.s. pressed butt hinges bright finished of required size with necessary screws.(kiln seasoned and chemically treated hollock wood) 50 providing and fixing35mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with isi marked m.s. pressed butt hinges bright finished of required size with necessary screws.(kiln seasoned selected planks of sheesham wood) 51 providing and fixing30mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with isi marked m.s. pressed butt hinges bright finished of required size with necessary screws.(kiln seasoned selected planks of sheesham wood) 52 providing and fixing30mm thick panelled or panelled & glazed shutters for cup board using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with isi marked m.s. pressed butt hinges bright finished of required size with necessary screws.(second class teak wood including isi marked anodised aluminium butt hinges with necessary screws) 53 providing and fixing isi marked 35mm thick flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including isi marked stainless steel butt hinges with necessary screws) 54 providing and fixing isi marked 30mm thick flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including isi marked stainless steel butt hinges with necessary screws) 55 providing and fixing isi marked 35mm thick flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters ( including isi marked stainless steel butt hinges with necessary screws) 56 extra for providing and fixing flush doors with on one side only decorative veneering instead of non decorative isi marked flush door shutters conforming to is: 2202 (part i) 57 providing and fixing 12mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with c.p. brass screws andpvc sleeves etc., wherever necessary complete : 58 providing and fixing 20mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with c.p. brass screws andpvc sleeves etc., wherever necessary complete : 59 providing and fixing 25mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with c.p. brass screws andpvc sleeves etc., wherever necessary complete : 60 providing and fixing 20mm dia (heavy type) nickel plated m.s. pipe curtain rods with nickel plated brackets : 61 providing and fixing 25mm dia (heavy type) nickel plated m.s. pipe curtain rods with nickel plated brackets : 62 providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. 63 providing and fixing 125x65x2.12 mm isi marked is:1341 oxidised m.s. pressed butt hinges with necessary screws etc. complete. (copper oxidised as per is 1378) 64 providing and fixing 100x58x1.90 mmisi marked is:1341 oxidised m.s. pressed butt hinges with necessary screws etc. complete. (copper oxidised as per is 1378) 65 providing and fixing 75x47x1.70 mmisi marked is:1341 oxidised m.s. pressed butt hinges with necessary screws etc. complete. (copper oxidised as per is 1378) 66 providing and fixing 50x37x1.50 mmisi marked is:1341 oxidised m.s. pressed butt hinges with necessary screws etc. complete. (copper oxidised as per is 1378) 67 providing and fixing 150 mm isi marked oxidised m.s. single acting spring hinges with necessary screws etc. complete (copper oxidised as per is 1378) 68 providing and fixing 125 mm isi marked oxidised m.s. single acting spring hinges with necessary screws etc. complete (copper oxidised as per is 1378) 69 providing and fixing 100 mm isi marked oxidised m.s. single acting spring hinges with necessary screws etc. complete (copper oxidised as per is 1378) 70 providing and fixing 250x16 mm isi marked oxidised m.s. sliding door bolts with nuts and screws etc. complete (copper oxidised as per is 1378) 71 providing and 250x10 mm fixing isi marked oxidised m.s. tower bolt black finish, (barrel type) with necessary screws etc. complete (copper oxidised as per is 1378) 72 providing and 200x10 mm fixing isi marked oxidised m.s. tower bolt black finish, (barrel type) with necessary screws etc. complete (copper oxidised as per is 1378) 73 providing and 150x10 mm fixing isi marked oxidised m.s. tower bolt black finish, (barrel type) with necessary screws etc. complete (copper oxidised as per is 1378) 74 providing and 100x10 mm fixing isi marked oxidised m.s. tower bolt black finish, (barrel type) with necessary screws etc. complete (copper oxidised as per is 1378) 75 providing and fixing isi marked 85x42 mm oxidised m.s. pull bolt lock conforming to is : 7534 with necessary screws bolts, nut and washers etc. complete (copper oxidised as per is 1378). 76 providing and fixing 125 mm isi marked oxidised m.s. handles conforming to is:4992 with necessary screws etc. complete (copper oxidised as per is 1378) 77 providing and fixing 100 mm isi marked oxidised m.s. handles conforming to is:4992 with necessary screws etc. complete (copper oxidised as per is 1378) 78 providing and fixing 75 mm isi marked oxidised m.s. handles conforming to is:4992 with necessary screws etc. complete (copper oxidised as per is 1378) 79 providing and fixing 150 mm oxidised m.s. hasp and staple (safety type) conforming to is : 363 with necessary screws etc. complete (copper oxidised as per is 1378) 80 providing and fixing 115 mm oxidised m.s. hasp and staple (safety type) conforming to is : 363 with necessary screws etc. complete (copper oxidised as per is 1378) 81 providing and fixing 90 mm oxidised m.s. hasp and staple (safety type) conforming to is : 363 with necessary screws etc. complete (copper oxidised as per is 1378) 82 providing and fixing 300 mm (weighing not less than 330 grams) oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete (copper oxidised as per is 1378) 83 providing and fixing 125mm special quality bright finished brass handles with screws for cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 84 providing and fixing 100mm special quality bright finished brass handles with screws for cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 85 providing and fixing 75mm special quality bright finished brass handles with screws for cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 86 providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 87 providing and fixing triple strip vertical type magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. 88 providing and fixing double strip (horizontal type) magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. 89 providing and fixing factory made upvc door frame made of upvc extruded sections having an overall dimension as below (tolerance ±1mm),with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. the hinge side vertical of the frames reinforced by galvanized m.s. tube of size 19 x 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of engineer- in-charge (extruded section profile size 48x40 mm) 90 providing and fixing factory made upvc door frame made of upvc extruded sections having an overall dimension as below (tolerance ±1mm),with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. the hinge side vertical of the frames reinforced by galvanized m.s. tube of size 19 x 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of engineer- in-charge (extruded section profile size 42x50 mm) 91 providing and fixing 12 mm thick fire retardant plywood conforming to is: 5509 panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. 92 providing and fixing cup board shutters 25 mm thick, with pre-laminated flat pressed three layer particle board or graded wood particle board is: 12823 marked, exterior grade (grade l type ll), having one side decorative lamination and other side balancing lamination, including iind class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the engineer-in-charge 93 providing and fixing aluminum u beading of required size to pre-laminated/flush door shutter, including fixing etc. complete as per direction of engineer-in-charge. 94 providing and fixing casement handle made of zinc alloyed (white powder coated) for upvc casement window with necessary screws etc. complete. 95 providing and fixing zinc alloyed (white powder coated) touch lock for upvc sliding window with necessary screws etc. complete. 96 providing and fixing steel roller for upvc sliding window with necessary screws etc. complete. 97 providing and fixing steel roller for upvc sliding door with necessary screws etc. complete. 98 providing and fixing steel (white power coated) crescent lock for upvc sliding window/ door with necessary screws etc. complete. 99 providing and fixing 18mm thick both sides pre-laminated cement bonded wood particle board as per is : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of engineer-in-charge (note: fittings to be paid separately). 100 providing and fixing 6mm thick both sides pre-laminated cement bonded wood particle board as per is : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. on the backing of racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of engineer-in-charge. 101 providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed bwp grade marine ply as per is 710 of approved brand including 2mm thick pvc edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of engineer-in-charge.(payment of providing and fixing auto closing hinges shall be paid separately) 102 structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 103 providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of t-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 104 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6 mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.(using m.s. angels 40x40x6 mm for diagonal braces) 105 providing and fixing stainless steel ( grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 106 providing and fixing angle iron frames for doors, windows and ventilators of mild steel angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing t-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of engineer-in-charge. 107 brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar with 1:6 (1cement : 6 coarse sand) including filling the joints with same mortar, with common burnt clay non modular bricks: 108 dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with jamuna sand, with common burnt clay non modular bricks. 109 40 mm thick with 20 mm nominal size stone aggregate cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 110 18 mm thick cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 111 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 112 cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. 113 25 mm thick kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 114 deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm. 115 fixing glazed/ ceramic/ vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (water based) conforming to is: 15477, in average 3mm thickness. 116 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 117 providing and fixing 1st quality ceramic glazed floor tiles conforming to is : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 118 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to is : 15622, of approved make, in all colours, shades, except white, ivory, grey, fume red brown, laid on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. 119 providing and laying vitrified floor tiles size 600x600 mm(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. 120 providing 1 mm thick with zinc coating not less than 275 gm/ m² corrugated g.s. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 121 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 122 providing & fixing 0.56 mm, aluminium color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm at all heights, levels and locations colour finish aluminium alloy roofing sheets of alloyis designation31500, temper hx8 conforming to is 737 and dimensions as per is code 2676 with characteristics of good formability and corrosion resistance. the profile sheets shall be fixed to truss members in slope or required pitch or curvature with hex cap headed self drilling/tapping stainless steel screws m6, 50 mm long with 3 mm epdm seal washer etc. all inclusive of labour, scaffolding, t&p and sundries etc. complete as per directions of the engineer-in-charge. (cost of truss/frame work shall be paid separately). 123 providing and fixing precoated/mill finish aluminium ridges plain (500- 600mm) of pre-coated colour or mill finishaluminium roofing accessories in 0.71 mm thickness ,alloy 31500 (is designation) [aluminium alloy (aa) 3004 (iso designation)]for color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping ss screws of size 6 x 50mm with 3mm thick epdm seal and ss plain washer complete : 124 providing 10 mm thick plaster of paris (gypsum anhydrous) flat surfaces ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): 125 12.5 mm thick fully perforated gypsum board tile made from plasterboard having glass fibre conforming to is: 2095 part i, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an nrc (noise reduction coefficient) of 0.79, with 50 mm resin bonded glass wool backing. 126 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) 127 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) 128 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) 129 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) 130 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 131 neat cement punning. 132 distempering with 1st quality acrylic distemper (ready mixed) new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than50 gram/litre of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 133 finishing walls for new work (two or more coats applied @ 3.84 kg/10 sqm) with water proofing cement paint of required shade : 134 finishing walls for new work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) with acrylic smooth exterior paint of required shade : 135 finishing walls for new work (two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. with ready mixed premium acrylic emulsion paint (company depot tinted) having voc less than 50 gm/litre and uv resistance as per is 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. 136 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 137 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 138 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) 139 painting (two or more coats) on 100mm diameter rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. 140 painting (two or more coats) on 150mm diameter rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. 141 painting two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 142 polishing on new wood work with ready mixed wax polish of approved brand and manufacture : 143 lettering with black japan paint of approved brand and manufacture 144 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 145 distempering for old work (one or more coats) with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturerincluding applying additional coats wherever required to achieve even shade and colour 146 applying priming coats with water thinnable cement primer on wall surface having voc content less than 50 grams/litre of approved brand and manufacture. 147 6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of engineer-in-charge. 148 removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 149 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 150 polishing on old wood work with ready made wax polish of approved brand and manufacture : 151 painting (one or more coats) with black japan paint of approved brand and manufacture to give an even shade. 152 finishing walls for old work (two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface with acrylic smooth exterior paint of required shade : 153 repairs to plaster of thickness 12 mm to 20 mm with cement mortar 1:4 (1 cement : 4 fine sand) in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of engineer-in-charge. 154 fixing door chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of engineer-in-charge. 155 fixing chowkhat in existing opening in brick/ rcc wall with dash fasteners/chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including cost of dash fasteners/ chemical fastener. 156 making the opening for door/ window/ clerestory window in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of engineer-in-charge. 157 renewing float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) with putty and nails wherever necessary including racking out the old putty: 158 renewing float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) with putty and nails wherever necessary including racking out the old putty: 159 renewal of old putty of glass panes (length) 160 refixing old glass panes with putty and nails 161 fixing old glass panes with wooden fillets (excluding cost of fillets) 162 renewing bottom rail and/or top runner of collapsible gate including making good all damages and applying priming coat of zinc chromate yellow primer of approved brand and manufacturer. 163 pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. 164 providing and fixing 20 mm diameter. brass curtain rods ofwall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. 165 repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modifiedself curing mortar, including disposal of rubbish, all completeas per the direction of engineer-in-charge. 166 cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of engineer-in-charge. 167 disconnecting damaged overhead/terrace pvc water storage tankof any size from water supply line and removing from the terrace including shifting at ground level as per direction of engineer-in-charge. 168 providing & fixing orissa pattern w.c pan of size 580x440 mm white vitreous china water closet squatting pan (indian type) along withs or p trap including dismantling of old wc seat and s or p trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of engineer-in charge. 169 dismantlingw.c.pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in-charge. 170 dismantling 15 to 40 mm dia g.i. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of engineer-in-charge.(a) internal work- exposed on wall 171 taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the engineer-in-charge. 172 demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of engineer- in-charge. 173 demolishing nominal cementconcrete 1:3:6 or richer mix (i/c equivalent design mix manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 174 demolishing nominal cementconcrete 1:4:8 or leaner mix (i/c equivalent design mix manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 175 demolishing r.c.c. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of engineer - in- charge. 176 demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 177 removing mortar from bricks in from brick work in cement mortar and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): 178 dismantling doors, windows and clerestory windows (steel or wood) shutter of area 3 sq. metres and below including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 179 dismantling doors, windows and clerestory windows (steel or wood) shutter of area beyond 3 sq. metres including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 180 taking out doors, windows and clerestory window shutters (steel or wood) of area 3 sq. metres and belowincluding stacking within 50 metres lead : 181 taking out doors, windows and clerestory window shutters (steel or wood) of area beyond 3 sq. metres including stacking within 50 metres lead : 182 dismantling for thickness of tiles 10 mm to 25 mmwork in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 183 dismantling for thickness of tiles above 25 mm and up to 40 mmwork in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 184 demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : 185 dismantling g.s. sheetroofingincludingridges,hips,valleysandguttersetc., and stacking the material within 50 metres lead of: 186 dismantling asbestos cement sheetroofingincludingridges,hips,valleysandguttersetc., and stacking the material within 50 metres lead of: 187 dismantling tiled roofing with battens, boarding etc. complete includingstackingofserviceablematerialanddisposalofunserviceable material within 50 metres lead. 188 dismantlingbarbedwireorflexiblewireropeinfencingincludingmaking rolls and stacking within 50 metres lead. 189 dismantling40 mm thick precast concrete orstone slabsin walls, partition walls etc. including stacking within 50 metres lead : 190 dismantling40 mm to 75mmthick precast concrete orstone slabsin walls, partition walls etc. including stacking within 50 metres lead : 191 dismantling cement asbestos or other hard board ceiling or partition wallsincludingstackingofserviceablematerialsanddisposalof unserviceable materials within 50 metres lead. 192 dismantling of flushing cistern of all types(c.i./pvc/vitrious china) includingstackingofusefulmaterialsnearthesiteanddisposalofunserviceable materials within 50 metres lead. 193 dismantling old plaster or skirting raking out joints and cleaning the surfaceforplasterincludingdisposalofrubbishtothedumping ground within 50 metres lead. 194 dismantlingaluminium/gypsumpartitions,doors,windows,fixed glazing and false ceiling including disposal of unserviceable material andstackingofserviceablematerialwithin50metersleadas directed by engineer-in-charge. 195 disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping groundorasapprovedbyengineer-in-charge,beyond50minitial lead, for all leads including all lifts involved. 196 cuttingroadandmakinggoodthesameincludingsupplyofextra quantities of materials i.e. aggregate, moorum screening, red bajri and labour (required.bituminous portion) 197 paintingroadsurfacemarking for new work (two or more coats) withadequatenosofcoatstogive uniform finish with ready mixed road marking paint conforming to is : 164, on bituminous surface in white/yellow shade, including cleaning thesurfaceofalldirt,scales,oil,greaseandforeignmaterialetc. complete. 198 paintingroadsurfacemarking for old work (one or more coats) withadequatenosofcoatstogive uniform finish with ready mixed road marking paint conforming to is : 164, on bituminous surface in white/yellow shade, including cleaning thesurfaceofalldirt,scales,oil,greaseandforeignmaterialetc. complete. 199 taking out existing cc interlocking paver blocks from footpath/ central verge,includingremovalofrubbishetc.,disposalofunserviceable materialtothedumpingground,forwhichpaymentshallbemade separately and stackingof serviceable materialwithin 50metre lead as per direction of engineer-in-charge. 200 layingoldcementcocreteinterlockingpaverblocksofanydesign/ shapelaidinrequiredline,level,curvature,colourandpatternover and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer- in-charge. (old cc paver blocks shall be supplied by the department free of cost). 201 providing and laying 80mmthickc.c.paverblockofm-35gradewith approved colour design and pattern.factory made chamfered edge cement concrete paverblocksinfootpath,parks,lawns,drivewaysorlighttraffic parkingetc,ofrequiredstrength,thickness&size/shape,madeby tablevibratorymethodusingpumould,laidinrequiredcolour& patternover50mmthickcompactedbedof sand,compactingand properembedding/layingofinterlockingpaverblocksintothesand beddinglayerthroughvibratorycompactionbyusingplatevibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. completeall as per direction of engineer-in-charge. 202 providing andfixingwhitevitreouschinaorissapatternw.c.panofsize 580x440 mm with integral type foot rests waterclosetsquatting pan(indian typew.c. pan)with100mmsandcastironporstrap,10litrelowlevel whitep.v.c.flushingcistern,includingflushpipe,withmanually controlleddevice(handlelever)conformingtois:7231,withall fittingsandfixturescomplete,includingcuttingandmakinggood the walls and floors wherever required: 203 providing and fixing w.c. pan with isi marked white solid plastic seat and lid white vitreous china pedestal type water closet (european type) with seat and lid, 10 litre low level white vitreous china flushing cistern & c.p. flush bend with fittings & c.i. brackets, 40 mm flush bend, overflow arrangement with specials of standard makeandmosquitoproofcouplingofapprovedmunicipaldesign complete,includingpaintingoffittingsandbrackets,cuttingand making good the walls and floors wherever required : 204 providingandfixing oneurinalbasinwith5litrewhitep.v.c.automaticflushing cistern whitevitreouschinaflatbackorwallcorner typelippedfronturinalbasinof430x260x350mmand 340x410x265 mm sizes respectively with automatic flushing cistern withstandardflushpipeandc.p.brassspreaderswithbrass unions and g.i clamps complete, including painting of fittings and brackets,cuttingandmakinggoodthewallsandfloorswhereverrequired : 205 providingandfixingwhitevitreouschinawashbasinsize550x400mm with a pair of 15 mm c.p. brass pillar taps washbasinwithc.i.brackets,15mmc.p. brasspillartaps,32mmc.p.brasswasteofstandardpattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 206 providing and fixing wash basin with c.i. brackets, 15 mm dia cp brasssingleholebasinmixerofapprovedqualityandmake, including painting of fittings and brackets, cutting and making goodthe walls wherever required:- (a)white vitreous china wash basin size 550x400 mm with a 15 mm cp brass single hole basin mixer 207 providingandfixingwhitevitreouschinapedestalforwashbasin completelyrecessedatthebackforthereceptionofpipesand fittings. 208 providing and fixing 610x510 mm bowl depth 200 mm stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required (kitchen sink without drain board) 209 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer - in - charge. 210 providing and fixing 10 litre capacity - white p.v.c. low level flushing cistern with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete. 211 providing and fixing 10 litre (full flush) capacity-white controlled flush, low level cistern made of vitreous china with all fittings complete. 212 providing and fixing g.i. inlet connection for flush pipe connecting with w.c. pan. 213 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer-in-charge. 214 providing and fixing15 mm nominal dia cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge. 215 providingandfixing 32mm diaflexible pipe p.v.c.wastepipeforsinkorwashbasin including p.v.c. waste fittings complete. 216 providing and fixing 100 mm sand cast iron grating for gully trap. 217 providingandfixinginposition25mmdiametermosquitoproofcoupling of approved municipal design. 218 providing and fixing 600x450 mm beveled edge mirror of superior glass(ofapprovedquality)completewith6mmthickhardboard ground fixed to wooden cleats with c.p. brass screws and washerscomplete. 219 providing andfixing circular shape 450 mm dia mirrorofsuperiorglass(ofapprovedquality)andofrequiredshapeandsizewithplasticmouldedframeof approved make and shade with 6 mm thick hard board backing : 220 providing andfixing 600x120x5 mmglass shelfwith edges round off, supported on anodised aluminium angle frame with c.p. brass bracketsandguardrailcompletefixedwith40mmlongscrews, rawl plugs etc., complete. 221 providing and fixing c.p. brass toilet paper holder : 222 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 223 providing and fixing ptmt towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 224 providing and fixing ptmt 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 225 providing and fixing ptmt 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 226 providing and fixing ptmt shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. 227 providing and fixing ptmt 15 mm urinal spreader size 95x69x100 mm with 1/2 bsp thread and shapes, weighing not less than 60 gms. 228 providing and fixing 15 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. (internal work - exposed on wall) 229 providing and fixing 20 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. (internal work - exposed on wall) 230 providing and fixing 25 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. (internal work - exposed on wall) 231 providing and fixing 15 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.(concealed work) 232 providing and fixing 20 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.(concealed work) 233 providing and fixing 25 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.(concealed work) 234 providing and fixing 15 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 235 providing and fixing 20 mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 236 providing and fixing 25mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 237 providing and fixing 32mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 238 providing and fixing 40mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 239 providing and fixing 50mm nominal dia chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.(external work) 240 providing and fixing 15 mm dia nominal bore g.i. pipes complete with g.i. fittings and clamps, i/c cutting and making good the walls etc.(internal work - exposed on wall) 241 providing and fixing 20 mm dia nominal bore g.i. pipes complete with g.i. fittings and clamps, i/c cutting and making good the walls etc.(internal work - exposed on wall) 242 providing and fixing 25 mm dia nominal bore g.i. pipes complete with g.i. fittings and clamps, i/c cutting and making good the walls etc.(internal work - exposed on wall) 243 providing and fixing 15 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 244 providing and fixing 20 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 245 providing and fixing 25 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 246 providing and fixing 32 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 247 providing and fixing 40 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 248 providing and fixing 50 mm dia nominal bore g.i. pipes complete with g.i. fittings including trenching and refilling etc.(external work) 249 providing and fixing 25 mm nominal bore gun metal gate valve with c.i. wheel of approved quality (screwed end) : 250 providing and fixing 20 mm nominal bore gun metal gate valve with c.i. wheel of approved quality (screwed end) : 251 providing and fixing 32 mm nominal bore gun metal gate valve with c.i. wheel of approved quality (screwed end) : 252 providing and fixing 15 mm nominal bore ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 253 providing and fixing 20 mm nominal bore ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 254 providing and fixing 15mm norminal bore 45 cm length uplasticised pvc connection pipe with brass unions : 255 providing and fixing 20mm norminal bore 45 cm length uplasticised pvc connection pipe with brass unions : 256 providing and fixing 100 mm diameter c.p. brass shower rose with 15 or 20 mm inlet : 257 providing and fixing 150 mm diameter c.p. brass shower rose with 15 or 20 mm inlet : 258 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 259 providing and fixing 15 mm nominal bore c.p. brass bib cock of approved quality conforming to is:8931 : 260 providing and fixing 15 mm nominal bore c.p. brass long nose bib cock of approved quality conforming to is standards and weighing not less than 810 gms. 261 providing and fixing 15 mm nominal bore c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 262 providing and fixing 15mm nominal bore c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 263 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 264 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 265 providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to is: 1868, minimum anodic coating of grade ac 15) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer-in-charge. (glazing, paneling and dash fastenersto be paid for separately) :(for fixed portion) 266 providing and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer-in-charge. (glazing, paneling and dash fastenersto be paid for separately) :(for fixed portion) 267 providing and fixing glazing with float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (cost of aluminium snap beading shall be paid in basic item): 268 providing and fixing glazing with float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (cost of aluminium snap beading shall be paid in basic item): 269 providing and fixing glazing with float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (cost of aluminium snap beading shall be paid in basic item): 270 providing and fixing with stainless steel cover plate minimum 1.25 mm thicknessdouble action hydraulic floor spring of approved brand and manufacture conforming to is : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece m.s. sheet outer box with slide plate etc. complete as per the direction of engineer-in-charge. 271 providing and fixing with brass cover plate minimum 1.25 mm thicknessdouble action hydraulic floor spring of approved brand and manufacture conforming to is : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece m.s. sheet outer box with slide plate etc. complete as per the direction of engineer-in-charge. 272 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. this layer will be allowed to air cure for 4 hours.(b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) 273 providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of fibre glass cloth when the first layer is still green. overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. this will be allowed to air cure for 4 hours followed by water curing for 48 hours. the entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. (for the purpose of measurement the entire treated surface will be measured.) 274 providing & applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer(dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of engineer-in-charge. 275 providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of rcc structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. after cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. over the primed surface swellable type water stop tape shall be placed. the work shall be carried out all complete as per specification and the direction of the engineer-in-charge. the product performance shall carry guarantee for 10 years against any leakage. 276 providing and fixing with15mmthick fullyperforatedsquare/buttedgelightweightcalcium silicate panels/ tiles in position wall panelling at all heights with integral densified calcium silicatepanels/tilesofsize595x595mm,havingnrc(noisereductioncoefficient)of0.50 (minimum) as per is 8225:1987, light reflectance of 85% (minimum). non combustible as per bs:476 (part-4), fire performance as per bs:476 (part 6 &7), humidity resistanceof 100%,thermalconductivity<0.043w/mk asperastm518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mmthickpressedsection(galvanizing@120gramspersqmincludingbothsides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor andceilingchannel sectionofsize50x32mfixedtothefloorandsoffitat600mm centersusing12mmdia,50mmlongwedgetypeexpandedzincalloy dashfastnerwith 10mm bolt. this same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. glasswool of 50mm thickness is then to be inserted in the slots and finallycalcium silicate non combustible panels/tiles are to bescrew fixed withselftapping panheadnickel coatedmild steelscrewsofsize13x3.2mmon tothisgridleavingan evengroove of1 mm betweenthepanels. the joints betweenthepanelsaretobedulyjointedandfinishedusingrecommendedjointing calcium silicate based compound and fiber joint tape roll 50mm wide(90 metre )roll and twocoatsofprimersuitableforpanellingaspermanufacturersspecificationasper direction of engineer-in-charge all complete. 277 providing and fixing with 16 mm thick beveled tegular mineral fibre false ceiling tile (nrc 0.55 to 0.6 mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance (rh) of 99%,lightreflectance=85%,thermalconductivityk=0.052-0.057w/mk,fire performance as per (bs 476 pt - 6 &7)in true horizontal level suspended on interlocking t- grid of hot dipped all round galvanized iron section of 0.33 mmthick (galvanized @120 gsm)comprisingofmaintrunnersof15x32mmoflength3000mm,crosstofsize 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length600mm toform gridmoduleofsize 600x600mm suspendedfrom ceiling using galvanizedmildsteelitem(galvanised@80gsm)50mmlong8mmouterdiameterm-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l- shapeleveladjusterofsize85x25x2mm,spacedat1200mmcentretocentrealong main‘t’.thesystemshouldrestonperipherywalls/partitionswiththehelpofgi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thicksheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry walls.s. screws. the exposed bottom portion of all t-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. the work shall be carriedoutasperspecifications,drawingsandasperdirectionsoftheengineer-in- charge. 278 providingandfixingharddrawnsteelwirefabricofsize75x25mmmeshorother suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of l shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by engineer-in-charge. 279 fillingofjointsbetweenrccplinthbeam/floorslabandwallpanelofexternalwalls, toilet / bath room / wet areas walls on all floor and parapet wall over roof slab, stair case headroomatthetimeoferectionofgfrgpanelswithgroutrw/equivalentsealant compound after the erection of panelbeforethe infill of concrete in panel cavities and fine finish. this applies for all horizontal and vertical joints between gfrg wall and slab panels. 280 waterproofingtreatmentofverticaljoints(ofexternalsideandinternalside)between doorframe,window&ventilatorframes(onallfoursides)ofouterwalloverthe zycosil/equivalent & zycoprime/equivalent solution already applied (before the installation of door / window / ventilator frames in position) and fine finish with grout rw/equivalent. 281 waterproofingtreatmentofrccsunshadewith zycosil/equivalentwaterproofing solution(1litreofzycosil/equivalent&20litresofwaterstirredfirst&2litresof zycoprime/equivalent addedandstirred (total23litres))till itmeetsthesaturationlevel and testing as per rilem or bywater drops test in which water drops do not absorb but drops remain or rolls. 282 in-filling / sealing of joint between rcc lintel cum sunshade and wall (on external side) in all floors by pushing in grout rw/equivalentin paste form and coving 20 mm x 20 mm after applying a coat of zycosil/equivalent & zycoprime/equivalent solution before cement plastering of top, bottom and sides of rcc sunshade. 283 concreteworkwith40mmgaugebrickballastobtainedfrombreaking brick bats (brick bats supplied by the department free of cost) in proportion of 12:6:1 as in csi no. 5.01 includingcost of all labour, materials, t&p etc required for proper completion of work. 284 brickworkinfoundation&plinthwitholddismantled bricks(suppliedby departmentfreeofcost)andcoarsesand mortarin1:6includingsupply ofallothermaterials,labour,removingmortar&cleaningofold&usedbricks,t&p etc complete. 285 supply and filling brick bat in soak pit including all labour,material and t&petc complete. (for 01 soak pit) 286 supplying & fixing 24 gauge annodized aluminium sheet of approved qualityincludingcutting,wastageandfixingthesameoverthewooden door shutters with nails with all material, labour and t&p 287 providingandfixinginplaceafullheightstoragecabinet450mmdeep made with19 mm thick isi marked plyborad, allinterior surfaces to finishedwithpastingof0.8mmthickmicaandallexteriorsurfacestobe finshed with pasting of 1 mm thick mica of texture and colour as approved byengineerinchargeincludingalllabour,t&p,otheritemslike(butnot limitedto)fevicol,nailsscrews,higes,sliders,doorhandles,multipurpose lockofgodrejorequivalentrateetc.requiredforpropercompletionof works, to be measured interms of front area only. 288 providingandfixingfullheightpartitionwith02nos12mmthickisi marked ply board, all surfaces to finished withf 1 mm thick mica of texture andcolourasapprovedbyengineerinchargeandfixedinpolishedteak woodincludingalllabour,t&p,otheritemslike (butnot limitedto) fevicol, nailsscrews,hinges,sliders,doorhandles,multipurposelockofgodrejor equivalent rate etc. required for proper completion of works, to be measured interms of front area only 289 providingandfixing12mmthickframelesstoughenedglassdoorshutter ofapprovedbrandandmanufacture,includingprovidingandfixingtop& bottom pivot & double acting hydraulic floor spring type fixing arrangement ,doorhandle,lockandstopperetcandmakingnecessaryholesetc.for fixingrequireddoorfittings,allcompleteasperdirectionofengineer-in- charge 290 supply and fixing 6mm thick polycarbonate multiwall sheet ,fixing in position with j or u bolts 10 mm. dia with g.i. limpet & bitumen washers including supply of all materials, labour,wastage. and t&p etc. required for proper completion of the work. 291 providing (12x15) mm section groove in plasterincluding all material, labour andt&p etc. required for proper completion of the work.csi no.11.16 292 2.5 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and t&p etc, required for proper completion of the work. without base cccsi no.12.26 293 4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and t&p etc, required for proper completion of the work. without base cc csi no. 12.28 294 dismantling ofdry b.o.e. floor and proper stacking of dismantled bricks as per direction of e/c. up to 60 m lead. 295 dismantling and re-laying of dry b.o.e. floor including cost of all labour and t&p required forproper completion of work.(labour rates only) 296 cleaning panes of glass with spirit of caustic soda including supply of all materials,labour and t&p etc.required for proper completion of the work. 297 cleaning of septic tank including disposal of waste out side the uppcl area as per direction of the engineer-in-charge including cost of all labour,t&p etc.required for proper completion of the work. 298 cleaning and opening of chocked w.c./ bath / kithchen pipe line including opening and refixing of chamber cover including washing etc. complete.(analysis based on nbo - 11 25.020. 299 s/laying chicken mesh of (20 mm.)hexagonal heavy quality over roofs of joints of roof as per direction of the engineer - in - charge. 300 cleaning of existing pipe line of different dia. ranging from 4 to 2 dia. including digging trenches and refilling, opening of pipes, cleaning of pipes, cutting, threading, if required fixing and including making good the road, wall etc as directed by the engineer i/c. 301 cleaning of existing water pipe line of different dia up to 2 dia including digging trenches and refilling,opening and cleaning of pipes,cutting,threading,if required fixing and including making good the road and wall etc. as directed by the engineer in charge. 302 cleaning of r.c.c. over head tank up to capacity of one lac. liters and chlorinating with bleaching power mixed to water as per direction of engineer - in - charge complete. 303 supply and mixing bleaching powder in over head tank as required or as directed by engineer - in - charge. 304 attending to petty maintenance service like plumbingservice,welder service, mansion service and carpenter servicerequired as below. (job attending by one no. plumber/welder/mason /carpenter with oneno. helper per hour or part of an hour.) 305 cleaning and sweeping of roof of residence as and when requiredincluding uprooting of rank vegetation and disposal of thegarbage upto 50 m. 306 providing and fixing of 150 mm dia pvc pipeof 6 kg/sqcmwith special such as tee, bend, socket, elbow etc including supply of all labour,material,t & p etc complete required for proper completion of work. 307 providing and laying 75 mm dia. swr, pvc ( finolex or equivalent ) pipe including cost of excavation, c.c etc including its jointing and connection, all materials, labour and t&p etc. required for proper completion of the work. 308 providing and laying 90 mm dia. swr, pvc ( finolex or equivalent ) pipe including cost of excavation, c.c etc including its jointing and connection, all materials, labour and t&p etc. required for proper completion of the work. 309 providing and laying 110 mm dia. swr, pvc ( finolex or equivalent ) pipe including cost of excavation, c.c etc including its jointing and connection, all materials, labour and t&p etc. required for proper completion of the work. 310 making arrangement for sweeping, cleaning of road, lanes in back of houses,collecting refuse of bushes & unwanted plants, vegetations etc. & disposal of all rubbish, materials industbins inside the colony area with engaging atleast one number of sweepers including all labour, t&p,etc.required for completion of work as directed by e/i. 311 making arrangement for sweeping, cleaning of ee,ecd(d), georgetown ,prayagraj office rooms, cleaning of dustbin, toilets , dusting of almirahs,tables etc. using phenyle,dusting cloth etc. and disposal of waste outside office premise in municipal dustbinswith engaging sufficient number ofsweepersincluding all labour, t&p,etc.required for completion of work as directed by e/i.(nsi)(consumable items as phenyle,dusting cloth ,brooms etc shall be provided by the department free of cost.) 312 cleaning of main drain or width more than 300mm including disposal of waste refuses studge out side the boards ara including washing and cleaning by clean water completely as per direction of the e/i. including cost of all labour, t&p etc. required for completion of the work. (csino.20.14) 313 cleaning of main drain or width less than 300mm including disposal of waste refuses studge out side the boards ara including washing and cleaning by clean water completely as per direction of the e/i. including cost of all labour, t&p etc. required for completion of the work. (csino.20.15) nsi sl. no.63 314 operation of tube well daily by a suitable experienced operator continously or in different intervals as per program as per program fixed by engineer-in-charge including opening and closing of valves,changing of fuse wire etc. as requrird for proper running of tube well. (nsi) 315 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc as required..group c 316 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet 317 supplying and fixing of 20 mm of medium class pvc conduit along with accessories in surface/recess including junction box, cutting the wall and making good the same in case of recessed conduit as required. 318 supplying and fixing of 25 mm of medium class pvc conduit along with accessories in surface/recess including junction box,cutting the wall and making good the same in case of recessed conduit as required. 319 wiring for circuit/ submain wiring with 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 320 wiring for circuit/ submain wiring with 2 x 4 sq. mm + 1 x 4 sq. mm earth wire of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 321 wiring for circuit/ submain wiring with2 x 6 sq. mm + 1 x 6 sq. mm earth wire of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 322 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required . 323 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 324 supplying and fixing 5 amps to 32 amps rating,single pole, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 325 supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 326 supplying and fixing 40 amps, double pole, 240 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 327 supplying and fixing 4 way (4 + 12), double door, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 328 supplying and fixing of 4 way (4 + 12), double door surface/ recess mounting, vertical type, 415 volts, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs (but without mcbs and incomer ) as required . (note : vertical type mcb tpdb is normally used where 3 phase outlets are required.) 329 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit along with 1 no 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 330 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module (75mmx75mm) 331 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required.3 module (100mmx75mm) 332 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 4 module (125mmx75mm) 333 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 6 module (200mmx75mm) 334 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 8 module (125mmx125mm) 335 supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required. 12 module (200mmx150mm) 336 supplying and drawing following 3 x 2.5 sq. mm sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 337 supplying and drawing following 3 x 4 sq. mm sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required.(dsr e&m 2022 1.17.21) 338 rewinding of burnt ceiling fan with approved copper wire including cost of all materials, labour and t&p etc. complete (burnt wirewill not be taken back.) 339 greasing of ceiling fan after cleaning the bearing and shaft withoil / petrol and its testing. 340 supply and fixing of led tube light batten fitting suitable for up to 1 x 22 watt led tube light on surface complete in all respect.(csi no. 28.41) 341 supply of 9 watt led bulb make philips, syska, bajaj etc or its equivalent as directed by e/i. 342 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min, 350 rpm (tolerance as per is: 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required.(dsr e&m 2022 19.1) 343 supply and fixing of 5 blade exhaust fan ventile air dx 225 mm of havellsor equivalent make including all material, t&p etc required for proper completion of work as approved by engineer in charge.(csi no. 28.38) 344 supply and fixing of 3 blade wall fan ofhavells platina 400 mm or equivalent including all material, t&petc required for proper completion of work as approved by engineer in charge.(csi no. 28.37)
  • View Tender
  • Document
  • Bid Support
15 Construction
image image
State Government
TRN :49058034 |  15 May, 2025
Tender Value : 10.00 Lacs
 Lalitpur - Uttar Pradesh
Tender for tender for road safety and signage work on roads under ae-ii in fy-2025-26 - speed limitproviding and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per irc:67 mad of high intensity grade sheeting vide clause 801.3, fixed cover aluminium shting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to th ground by means of properly dsignd foundation with m-15 grade cment conc. 45 cm x 45 cm x 60 cm, 60 cm below ground lvel as per approved drawing 2 road delinatordelineator: supply & fixing of ms delineator made of mild steel with pure polyester powder coating with the minimum thickness of powder coating of not less than 40 microns for protection against corrosion. the surface should be conceated so that there should not be any exposed surface without powder coating. 3 traffic signs -hazard marker (left/right) providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per irc:67 mad of high intensity grade sheeting vide clause 801.3, fixed cover aluminium shting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to th ground by means of properly dsignd foundation with m-15 grade cment conc. 45 cm x 45 cm x 60 cm, 60 cm below ground lvel as per approved drawing 4 providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per irc :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with m15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing(double chevron (normal)) as per morth-801 (8.4 (iii) 5 direction and place indentification signs with more than 0.90 sqm sizewarning boardproviding and erecting direction and place identification retro-reflectorised sign as per irc-67 made of high intensity grade sheeting the retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from international/ government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally. in such a situation, the employer/client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per irc 67:2012. legends, letters, numerals and borders etc should be as per morth specification no-801.3.7. sheet fixed over aluminium sheeting, 2mm thick with area exceeding 0.9 sqm. supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with m-15 grade cement concrete 45x45x60 cm., below ground level as per approved drawing, complete. (morth-801 (8.6) 6 retro reflective sheeting type xi with 4 mm thick acm double side morth-801 (sl. no. 12) 7 providing and laying of hot applied thermoplastic compound 5.00 mm thick including reflectorising glass beads @ 500 gms per sqm area, thickness of 5.00 mm is exclusive of surface applied glass beads as per irc:35 .the finished surface to be level, uniform and free from streaks and holes. (repeated bars) morth-803(8.130)-base 8 solar power road marker (solar studs)the solar studs shall be made of aluminium alloy and poly carbonate material which shall be absolutely weather resistant and strong enough to support a load of 13,635 kg tested in accordance with astm d4280. its colour may be white, red, yellow, green or blue or combination as directed by the engineer. its water resistance shall meet the requirements of ip 65 in accordance with is:12063:1987 category 2 for protection against water ingress. the dimensions of solar studs shall not be less than 100 mm x 100 mm x 10 mm. it shall have super bright leds so as to provide long visibility from a distance of more than 800 m. its flashing rate shall not be less than 1 hz. its should be able to give the prescribed performance in the temperrature range of 40°c to +55°c. its life shall be not less than 3 years. the rate shall include all materials, labour, equipments, fabrication, transportation, erection, installation and incidentals all complete as per direction of the engineer-in-charge.
  • View Tender
  • Document
  • Bid Support
16 Road Transport
image image
corporations/Associations/Others
TRN :49065836 |  09 Jun, 2025
Tender Value : 0
 Bengaluru - Karnataka
Tender for tender for 1 procurement of kyocera cartridge, epson ribbon cartridge. 2 procurement of air filters, oil filters and fuel filters. 3 procurement of piston assembly & ring sets. 4 procurement of thin walled bearings. 5 procurement of dash board instruments. 6 procurement of auto electricals items. 7 procurement of brake liners and clutch facings with rivets. 8 procurement of engine valves, guides & inserts. 9 procurement of liquid urea (aus-32) for bs vi vehicles. 10 procurement of automotive batteries, 11 procurement of aluminium sheets. 12 procurement of g.p. coil and h.r. sheets.
  • View Tender
  • Document
  • Bid Support
17 Defence
image image
Statutory Bodies and Commissions/Committees
TRN :49019692 |  27 May, 2025
Tender Value : 0
 Leh - Ladakh
Tender for tender for supply and construction of sentry post s and c; supply and construction of sentry post s and c specification attached in rfp ; 1 pp-r pipe (pn 20/sdr-6) 3 layer with outer dia 40mm. rm 9 2 pp-r pipe (pn 20/sdr-6) 3 layer with outer dia 32mm. rm 16 3 pp-r tank connector outer dia 40mm nos 1 4 pp-r gate valve connector outer dia 32mm nos 1 5 pp-r elbow 45 degree plane outer dia 40mm nos 3 6 pp-r elbow 45 degree plane outer dia 32mm nos 4 7 pp-r tee reducer 40-32mm nos 2 8 pp-r tee 32mm (45 degree) nos 4 9 pp-r union outer dia 32mm nos 2 10 pp-r wall clamp dia 32mm nos 12 11 pp-r wall clamp dia 40mm nos 4 12 pp-r socket outer dia 32mm nos 8 13 pp-r socket outer dia 40mm nos 2 14 pp-r plug dia 15mm nos 2 15 pp-r female threaded elbow dia outer dia 32mm x 15mm nos 4 16 pp-r male threaded elbow dia outer dia 32mm nos 4 17 pp-r female threaded socket outer dia 32mm x 15mm nos 2 18 pp-r female threaded socket outer dia 40mm x 15mm nos 2 19 pp-r gate valve connector outer dia 40mm nos 1 20 pp-r wall clamp dia 75mm nos 12 21 pp-r adhesive ltrs 3 22 silicon tape nos 2 23 insulation for pp-r pipe 40mm rm 9 24 insulation for pp-r pipe 32mm rm 16 25 rock wool for insulation rm 40 26 aluminium sheet 2mm to cover external pipes of one ft width rm 30 1 stainless steel iwc of size 580mmx440mm with cistern 10 ltrs cap flushing cistern (pvc) complete with entire accessories as per good engineering practice. nos 1 2 stainless steel whb of size 400mmx400mm including ms stand and pvc hdpe pipe 32 mm dia etc complete nos 1 3 cp bib cock of 15mm bore (short body) nos 2 4 cp stop cock of 15mm bore nos 4 5 looking mirror of size 600x450mm with pvc beading make: nos 1 6 cp soap dish of 100mm dia nos 1 7 pvc insulated connection 15 mm dia 450mm long with isi mark nos 4 8 dwchp pipe 110mm dia pipe mtr 12 (i) socket nos 6 (ii) tee (45 degree) nos 2 (iii) bend nos 6 9 pvc nahani trap 75mm dia nos 2 10 stainless steel jali with hole for waste pipe of 100mm with isi mark nos 1 11 stainless steel jali without hole for waste pipe of 100mm with isi mark nos 2 12 cp pillar cock 15mm dia nos 1 13 dwchp 75mm dia pipe mtr 12 (i) socket nos 4 (ii) tee (45 degree) nos 4 (iii) bend nos 4 (iv) cowl nos 1 14 pvc 75mm dia vent pipe 1200 mm long with cowl nos 2
  • View Tender
  • Document
  • Bid Support
18 Defence
image image
Statutory Bodies and Commissions/Committees
TRN :49019704 |  12 May, 2025
Tender Value : 0
 Karu - Ladakh
Tender for tender for supply and construction of ug tac hq (qty-03 nos) under job no 6151/2025-26 (s&c) (cow); 1 ug tac hq nos 1 2 soakage/septic tank cover nos 6 3 iron foot scraper nos 2 4 lightening conductor nos 1 5 earthing building nos 1 6 fire extinguisher 1 kg ball type nos 8 7 fire extinguisher 2 kg nos 8 8 smoke alarm nos 10 9 35 kva dg set nos 1 10 water storage tk 500 ltr sintex nos 4 11 elect items set 1 annx i 12 ppr items set 1 annx ii 13 sanitary items set 1 annx iii 1 supply and fix led tube light fitting1x 20 watt, complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size(more than 05 yrs warranty). nos 6 2 supply and fix led invertor rechargeable tube light fitting1x 20 watt , complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.(more than 05 yrs warranty). nos 5 3 supply and fix led luminaire 600mm x 600mm of 30 watt ,220 volt ac surface type with high efficiency soft glare light complete with driver holder & led lamp suitable for roof surface / ceiling incl including connecting up with twin core twisted flexible copper conductor cable with suitable size complete.(more than 05 yrs warranty). nos 8 4 supply and fix led mirror light fitting1 x 10 watt , complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size(more than 05 yrs warranty). nos 5 5 supply and fix bulk head 1x10w, 230 volt incl led light driver holder connecting up with twin core twisted flexible copper conductor cable with suitable size complete. (more than 05 yrs warranty). nos 3 6 supply and fix pvc lamp holder with isi mark. nos 5 7 supply and fix led invertor type rechargeable bulb 10 watt with isi mark.(more than 05 yrs warranty). nos 5 8 supply and fix switch socket combination 5 pin, 15 amp with isi mark. nos 8 9 supply and fix switch socket combination 5 pin, 5 amp with isi mark. nos 14 10 supply and fix ceiling rose three terminals (five layered) pvc poly carbonate, isolated body. nos 32 11 m&l for point wiring complete for one light point/ exhaust fan point/ bell point controlled by one switch with using 1.5 sqmm 1100 volt including 1.5 sqmm frls pvc insulated, unsheathed, multi standard copper conductor cable as continues earth wire connected to metallic bodies of luminaries/ fan etc at one end and to common earth dolly at other end, complete wiring drawn through pvc concealed of suitable size (as per conductor run) medium grade, isi mark including all accessories and fitting / junction box/ inspection covers/flexible conduit/ metal flush box of suitable size for fixing any types of switches/ socket etc point 37 12 all as above item no 11 here in before but point wiring for one socket point 6 amps on indepent board complete all as specified. point 10 13 all as above item no 11 here in before but point wiring for one socket point 6 amps on same board complete all as specified. point 4 14 all as per ser items no 11 here in before but with 2.5 sqmm frls copper wire with 1.5 sqmm frls copper earth wire for independent 15 amp points. point 8 15 sub main wiring 2x4 sqmm frls pvc insulated, unsheathed, multi standard copper conductor single core with earth wire complete. rm 40 16 supply and fix double door mcb distribution box spn 8 way complete conforming to ip65. nos 2 17 supply and fix mcb spn 32 amp,230v 50hz 10ka, b series. nos 2 18 supply and fix mcb sp 16 amp 240v 50hz b series. nos 2 19 supply and fix mcb sp 20 amp 240v 50hz b series. nos 3 20 supply and fix mcb sp 32 amp 240v 50hz b series. nos 4 21 supply and fix mcb sp 3 amp 240v 50hz b series. nos 3 22 supply and fix pvc body exhaust fan 200 mm sweep with louvers shutter, 230 volt ,50 hz, rpm 1200, copper winding and suitable size of hole for fixing of fan complete. nos 5 23 supply and fix switch piano type 5 amps isi marked. nos 37 1 pp-r pipe (pn 20/sdr-6) 3 layer with outer dia40mm with isi mark. rm 30 2 pp-r pipe (pn 20/sdr-6) 3 layer with outer dia 32mm rm 50 3 pp-r tank connector outer dia 32mm. nos 2 4 pp-r gate valve connector outer dia 40mm nos 2 5 pp-r elbow 90 degree plane outer dia 40mm nos 12 6 pp-r elbow 45degree plane outer dia 40mm nos 12 7 pp-r elbow 90 degree plane outer dia 32mm nos 12 8 pp-r elbow 45 degree plane outer dia 32mm nos 12 9 pp-r tee reducer 40-32mm nos 12 10 pp-r union outer dia 32mm nos 5 11 pp-r wall clamp dia 40mm nos 16 12 pp-r wall clamp dia 32mm nos 25 13 pp-r socket outer dia 32mm nos 10 14 pp-r socket outer dia 40mm nos 8 15 pp-r plug dia 25mm nos 5 16 pp-r plug dia 15mm nos 5 17 pp-r socket, elbow & tee each of dia 25mm set 25 18 pp-r socket, elbow & tee each of dia 20mm set 25 19 nitrile insulation min 50mm thick for pp-r pipe rm 80 20 adhesive solution sr-998 for jointing of insulation .make fevicol ltrs 5 21 1mm thick and 1 mtr wide aluminium sheet to cover nitrile insulation. minimum 50mm should be overlap and fixed with suitable length self taping screw distance of screw not more than 150mm c/c and ss band 13mm wide x 0.40mm thick with ms ring should be provided wherever required at suitable interval. rm 30 22 pp-r tee outer dia 32mm nos 5 23 pp-r female threaded elbow outer dia 32mm x 15 mm nos 25 24 pp-r male threaded elbow outer dia 32mm x 15 mm nos 5 25 pp-r female threaded socket outer dia 32mm x 15mm nos 10 26 pp-r female threaded socket dia 25mm nos 10 27 pp-r wall clamp dia 75mm nos 10 1 vitreous china ceramic ewc p &s (white colour) with 10 ltrs capacity pvc flushing cistern with seat cover (pvc) complete with entire accessories as per good engineering practice. nos 5 2 corner shelf of toughned glass with chromium plated steel frame. nos 5 3 cp towel rail 600mm long 20mm dia. nos 5 4 ceramic wash basin (630 x 450mm) (white colour) accessories to include waste pipe, coupling etc. nos 5 5 urinal pot vetreous china bowl urinal pot flat back model 5004 confirming to is 771 (part 3) sec 2 nos 5 6 chromium plated (cp) brass pillar cock. nos 5 7 chromium plated (cp) soap dish isi mark. nos 5 8 chromium plated (cp) bib cock mixture (long body). nos 5 9 chromium plated (cp) brass bib cock (short body) with isi mark. nos 5 10 chromium plated (cp) brass bib cock (long body) isi mark nos 5 11 chromium plated (cp) brass stop cock. nos 15 12 pvc insulated connection 16mm dia 450mm long nos 15 13 decorative looking mirror bath cabinet (600mm x 450mm) with suitable pvc frame nos 5 14 wash hand basin shelf of ss with chromium plated (cp) steel frame. nos 5 15 chromium plated (cp) steel coat hook with two prongs. nos 10 16 dcwpe pipe 75mm dia rm 35 (i) socket nos 10 (ii) tee nos 10 (iii) elbow nos 10 17 dcwpe 110mm dia rm 30 (i) socket nos 10 (ii) tee nos 5 (iii) elbow nos 5 18 stainless steel jali with hole for waste pipe. nos 10 19 stainless steel jali without hole. nos 5 20 pvc nahani trap 75mm dia. nos 10 21 pvc vent pipe 2 mtr length ,75mm dia with cowl 75mm dia. nos 2 22 health foucet with 1.2 mtr long nos 5
  • View Tender
  • Document
  • Bid Support
19 Power
image image
State Government
TRN :49021140 |  28 May, 2025
Tender Value : 6.35 Lacs
 Ballia - Uttar Pradesh
Tender for tender for supply and work for 02 nos. 33kv bays for jal jivan mission yojana at 132kv s/s dighar under etd, ballia. - laying and jointing pvc pipe. heading 2 supply-apgclamp suitable for moose to panther 3 pgclamp suitable forpanther to panther 4 phase plate (r,y,b phase ) 5 copper bond 6 led street light limiaire type sl-l19 45w) 7 40mm dia ms electrod of 3 meter length 8 40mm dia ms round bar 9 single tension fitting for acsr panther conductor 10 70 kn disc insulator 11 g.i nut &boltwith washer 16x40 mm 12 g.i nut &boltwith washer 16x45 mm 13 g.i nut &boltwith washer 16x50 mm 14 work -bsorting counting and loading for carriage of substation structure (8.00 mt) from efu naini prayagraj to 132kv s/s dighar 15 carriage of substation structure fromefu naini to 132kv s/s digharapproxdistance (8mt x 330=2640 ) 16 unloading and stacking of g.i structure at 132kv s/s dighar 17 erection of main and auxiliary structure by shifting of structure from store to work siteas per relevant drawing and practices using nut - bolt and spring washers .the material shall be supplied by department free of cost but the contractor has to managet&p and all other associated work to complete the job satisfactory. 18 stringing of 33 kv transfer bus bar ( r, y & b phase ) with acsr single pantherconductor including cutting, bending and clamping fitting of tension clamp with all associated accessories, hoisting of insulator string after shifting of material from store to worksite and all other associated work to complete the work satisfactory. 19 erection of following equipments as per instruction manual of various equipments and technical specification including shifting of material from store to work site includig all other associated work to complete the job satisfactory.30 kv la 20 36 kv ct 21 junction box for 36 kv ct 22 36 kv vcb 23 36 kv bsi 24 36kv lsi 25 33kv tripple feeder control & relay panel 26 dismantling of old tripple feeder panel for proper space for new panel including disconnection ofcontrol cable 27 erection of abt energy metering panel with 2nos abt meter 28 jumpering of equipments using single/double panther/zebra/moose conductor from bus bar to isolators,cb,ct,la, etc 29 laying of follwing size control cables from control & relay panels to various equipment junction boxes etcin switchyard as per cable schedule, its binding at every 1.5 mtr. distance with m.s. saddle including carriage of cable from store to work site and shifting back to store and all associated works to complete the job satisfactorily.2c x 2.5 sq. mm 30 4cx 2.5 sq. mm 31 6cx 2.5 sq. mm 32 termination of above cable as per cable schedule including making necessary holes in gland plates of boxes where ever required including supply and fixing of cable glands of approxinmate size and to provide ferrules and nos. for each core of cable and its termination with all the other associated works to complete the job. 33 delta earthing of 30 kv la consisting of 06 nos 3 meter long electodes its placing inside the ground and connecting all three electrodes with 75x10 mm ms flat and connecting the same with laat two place required including cost of m.s stripexcluding cost of m.s round bar 34 earthing ofmain & auxiliary structure and various type equipments (ct, cb, la, lsi, bsi etc ) by m.s strips by cutting to proper size, digging of earth from ground level to earthmat then proper welding as per drawing and leveling earth. painting of m.s strips of one coat red oxide primer and two coat with green colourand all associated work to complete the job satisfactory . m.s flat will be provided by the contractor.50 x 6 mm 35 25 x 6 mm 36 layingof 40 mm dia. round bar 700 mm below ground level including cutting straightening ,welding painting excavation of earth in trench from back filling after completion of work with all other associated work to complete the job satisfactory ,excluding cost of 40mm dia round bar. 37 fabrication of3 meter long electrode with 40 mmms round bar having 150 mm conical shape and then its piercingvertically inside the ground with top 700 mm below ground level and its welding exluding cost of 40 mm dia. round bar 38 providing and fixing of name plate made of 2mm thick aluminium sheet of 3m hip retro reflective sheeting plkates to be fixed with help of nut and bolts of istalled equipment structure of 400mm*250mm size 39 loading/unloading and carriage of 02nos 36kv vcb with structurefrom 132kv s/s sikandarpur to 132kv s/s dighar including loading at 132kv s/s sikndarpur by crane and unloading at 132kv s/s dighar by crane , men ,t&p, vahicle , crane arranged by contractor at own his cost
  • View Tender
  • Document
  • Bid Support
20 Construction
image image
State Government
TRN :49005623 |  26 May, 2025
Tender Value : 18.56 Crore
 Jayal - Rajasthan
Tender for tender for widening and strengthening on kasnau (sh-92a) to dehri - tarnau - merwas - upto mataji road - 1 part a road work clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per morth specification clause 201. by mechanical means in area of non-thorny jungle 2 excavation in soilwithdozer with lead upto 100 mexcavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections. 3 construction of embankment with material obtained from roadway cuttingconstruction of embankment with approved materials deposited at site obtained from roadway cutting and excavation from drain and foundation or other structures graded and compacted to meet requirement of tables 300-1 and 300-2 as per morth specification clause 305.3 4 construction of embankment with material obtained from borrow pitsconstruction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of tables 300-1 and 300-2 with a lead upto 50 m as per morth specification clause 305.3 5 granular sub-base with well graded material (table 400-1)by mix in place methodconstruction of granular sub-base by providing well graded material, spreading in uniform layers with tractor mount grader on prepared surface, mixing by mix in place method with rotavatorat omc, and compacting with smoothwheelroller to achieve thedesired density, complete as per morth specification clause 401. for grading iiimaterial 6 crusher run macadam baseproviding crushed run stone aggregate greading conforming to table 400-14 depositing on a prepared surface by hauling vehicles, spreading and mixing witha motor grader, watering and compacting with a threewheel 80-100 kn static roller as per morth specification clause 407 to form a layer of sub-base/base by mixing plant method with 53 mm maximum size of aggregates 7 wet mix macadamproviding, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing thematerial with water at omc in mechanical mixer (pug mill), carriage of mixed material by tipper to site, layingin uniform layers in sub-base/base course on a well prepared sub-base and compacting with smoothwheel roller of 80 to 100kn weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per tables 400-12 & 400-13 and morth specification clause 406. by mechanical means with all lead 8 prime coatproviding and applying primer coat with bitumen emulsion (ss-1) on prepared surface of granular base(wbm/wmm) including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per morth specification clause 502 9 tack coatproviding and applying tack coat with bitumen emulsion (rs-1)using emulsiondistributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with hydraulic broom as per morth specification clause 503. 10 tack coatproviding and applying tack coat with bitumen emulsion (rs-1)using emulsion distributor at the rate of 0.20 to 0.30 kg per sqm on the prepared bituminous surface cleaned with hydraulic broom as per morth specification clause 503. 11 providing and laying dense graded bituminous macadam with 100-120 tph batch type hmp producing an average output of 75 tones per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5 percentby weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per morth specifications clause 505 complete in all respects. bitumen (vg-30)grading - ii (26.50 mm (nominal size)) 12 providing and laying bituminous concrete with 100-120 tph batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6per centof mix and filler,transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per morth specifications clause 507 complete in all respectsfor grading-ii(13 mm nominal size) bitumen (vg-30) 13 providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using viscosity grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kn static roller capacity, finished to required level and grades to be followed by seal coat of either type a or type b or type c as per morth specification clause 510.by mechanical means bitumen (vg-30) 14 providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using type a, type b and type c as per morth specification clause 511type b bitumen (vg-30) 15 part b c.c. pavement work dry lean cement concreteconstruction of dry lean cement concrete sub- base over a prepared sub-grade with coarse and fine aggregate conforming to is: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing. 16 construction ofun-reinforced , plain cement concrete pavement m-40 (grade), thickness as per design, over a prepared sub base, with 43/53 grade cementas per clause 602.2.2 , coarse and fine aggregates conforming to is:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a in fullyautomatic batching plant andtransported to site intransit mixer for having continous agitated mixer, manufactured as per approved mix designincluding pumping of r.m.c. from transit mixer to site of laying , with all lead and lift including cost of admixtures in recommended portion as per is 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using fixed form paver and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days using water finishing to lines and grade as per drawingand morth specification clause 602 including vaccum dewatering process with all required equipments (dowel bars will be paid seprately). 17 providing and fixing of dowel bars of mild steel confirming to is : 432 of specified length and diameters as per morth specification irc 15 & 58 including cutting, placing in position across transverse joint with proper spacing, providing with pvc sleeve complete as per drawing, technical specification and as per direction of the engineer-in-charge. 18 part c protection wallearthwork in excavation for structures as per drawing and morth specifications clause 304.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. ordinary soil upto 3 m depth 19 providing concrete for plain/reinforced concrete in open foundations complete as per drawings and morth specifications clause 1702, 1703, 2102 & 2104 p.c.c grade m 10 nominal mix 1:3:6 20 stone masonry work in cement mortar in foundation complete as per drawing and morth specifications clauses 1402, 1405, 2102 & 2104. random rubble masonry in 1:6 cement mortar 21 plastering with cement mortar (1:4), 20 mm thick on stone work. 22 providing pcc m-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and morth specification clauses 1313, 1411 and 2206.650 mm thick 23 part d c.d.workearthwork in excavation for structures as per drawing and morth specifications clause 304.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. ordinary soil upto 3 m depth 24 providing concrete for plain/reinforced concrete in open foundations complete as per drawings and morth specifications clause 1702, 1703, 2102 & 2104 p.c.c grade m 10 nominal mix 1:3:6 25 providing concrete for plain/reinforced concrete in open foundations complete as per drawings and morth specifications clause 1702, 1703, 2102 & 2104 p.c.c. grade m 20nominal mix (1:2:4) 26 providing and fixing stone slab covering over drains (kota/bijoliya quarry) having thickness 75 mm to 150 mm including filling of joints in cement mortar 1:3 with 50 mm thick cement concrete flooring in 1:2:4 mix complete with good finish as per approved drawings and specifications.for drain opeining size 300 to 450 mm stone patty drain cover size 800mm x 600mm x 75mm 27 providing concrete for plain/reinforced concrete in open foundations complete as per drawings and morth specifications clause 1702, 1703, 2102 & 2104 p.c.c grade m 10 nominal mix 1:3:6 28 providing and laying reinforced cement concrete pipe np3 as per design in single row providing and laying reinforced cement concrete pipe np3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets clause 2905. 29 600 mmdia 30 300 mm dia 31 part f road saftykilometrestonereinforced cement concrete m15grade kilometre stone/local stone of standard design as per irc:8 fixing in position including painting and printing, etc as per drawing and morth specification clause 801 32 5th kilometre stone (precast) 33 ordinary kilometer stone (precast) 34 200 m stone (precast) 35 traffic signsretro-reflectorised traffic signsproviding and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per irc:67 made of encapsulated lens type reflective sheeting vide clause 801.3.1, fixed over aluminium sheeting, 1.5 mm thick supported on gi pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with m-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and morth specification clause 801 36 600 mm equilateral triangle 37 600 mm circular 38 600 mm x 450 mm rectangular 39 900 mm side octagon 40 direction and place identification signs upto 0.9 sqm size boardretro-reflectorised traffic signsproviding and erecting direction and place identification retro-reflectorised sign asper irc:67 made of encapsulated lens type reflective sheeting vide clause 801.3.1. fixed over aluminium sheeting, 2 mm thickwith areanot exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with m-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and morth specification clause 801. direction and place identification signs upto 0.9 sqm size board 41 direction and place identification signs with size more than 0.9 sqm size boardretro-reflectorised traffic signsproviding and erecting direction and place identification retro-reflectorised sign as per irc:67 made of encapsulated lens type reflective sheeting vide clause 801.3.1, fixed over aluminium sheeting, 2 mm thickwith areaexceeding 0.9 sqm supported on dia gi pipe firmly fixed to the ground by means of properly designed foundation with m-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and morth specification clause 801 42 marking centre line and stop lines etc. on road as per irc pattern with thermoplastic paint of approved quality and make with 8% glass beads laid on the road surface at temperature 160 c with a special applicator machine complete with a special applicator machine complete with labour material and traffic diversion arrangements. 43 supplying and fixing of cat’s eye made of aluminium alloy size 75x100x22 mm having 21 biconvex lenses embedded in circular disk of abs plastic on each side. 44 providing and fixing mukhya mantri sadak yojana/ mahatma gandhi rajya sadak yojana informatory sign board with logo for roads funded by state road fund having m.s. definition plate of 1.60 mm thickness frame to steel hollow dsection of 75mm x 75mm, 2.5m long stove enamelled paint with hold fast including paint logo as per approved design and colours. the logo shall be made out of 1.6mm thick circular plate duly framed with ms angle 25x25x5 mm on back and fix on 1200mm x 150mm rectangular steel base plate 1.6mm thick, the base of circular shall be plain at the junction of base plate. the size of definition plate shall be 1500x600mm and embedding the posts by m-15 cement concrete block45 cm x 45 cm x 60 cm, 60 cm below ground levelincluding lettering / writing and painting etc. complete in all respect.as per morth specification clause 801. 45 supply of swiss type of hazard marker, made out of 2 mm thick m.s. sheet size of box is 15x15 cm with hold fast at bottom, the body is painted in orange stoving enamel paint with white/high intensity grade micro-prismatic type sheeting, on all four side.
  • View Tender
  • Document
  • Bid Support
  • 1
  • 2
  • 3
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : metal sheets
  • Aluminum Sheet Sale Tenders ,
  • Puff Panel Tenders ,
  • Metal Sheet Tenders ,
  • Galvalume Sheet Scrap Tenders ,
  • Nova Pan Sheet Tenders ,
  • Sheet Metal Tenders ,
  • Copper Sheet Tenders ,
  • Jointing Sheet Tenders ,
  • Galvalume Sheet Tenders ,
  • Angle Sheet Tenders

Get metal sheets Tender Alert...

640995

Related Searched Keywords : metal sheets

  • Civil Work Tenders From Maharashtra
  • Rcc Fencing Tenders From Delhi
  • Floor Tiling Tenders From West-Bengal
  • Sculpture Work Tenders From -Tamil-Nadu
  • Bore Well Tenders From Andhra-Pradesh
  • Drills Tenders From Gujarat
  • Irrigation Tenders From Karnataka
  • Desilting Work Tenders From Uttar-Pradesh
  • Interlock Paver Tenders From Rajasthan
  • Land Levelling Tenders From Madhya-Pradesh

Read More


Tender Document

012314

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Rcc Pile Foundation Tenders
  • False Ceiling Repair Tenders
  • False Ceiling Work Tenders
  • Civil Engineering Service Tenders
  • Plastering Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App