Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Electrical Insulator
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of electrical-insulator Tenders

List of latest electrical-insulator Tenders in Indian Tenders. Click on any electrical-insulator Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for electrical-insulator Tenders.

Advance Search
  • All-Tenders (9)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
1 Security Services
image image
Central Government/Public Sector
TRN :49054084 |  10 Jun, 2025
Tender Value : 28.00 Crore
 Abohar - Punjab
Tender for tender for provision of deficient married accommodation at fazilka mil stn (job no: - mwp/swc-02/2024-25); 1 lump sum price worked out by the tenderer for“building /structure works as listed in schedule ‘a’ section - i 2 sch a section- ii, internal electrification works and flame proof fittings 3 material and labour for concealed point wiring for one light point/fan point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 20mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm (1:3)including fixing ofswitch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of boq as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). 4 -do- all as per srl no. 3 above but one three pin switch socket outlet 5 amps on the same borad 5 -do- all as per srl no. 3 above but one call bell controlled by one bell switch 6 -do- all as per srl no. 3 above but wiring with 2.5 sqmm multistranded cable and earth wire with copper conductor of size 2,5 sqmm for 5 amps point (on independent board) 7 material and labour for concealed point wiring for one socket outlet 15/20 amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 sqmm (nominal cross section area)single core frlsh pvc insulatedunsheathed and multi strand copper conductor cable 1100 volt (isi marked)drawn through andincludingpvc conduit 25mm dia (medium duty, isi marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including pressed steel powder coated sunken terminal box suitable for modular switch socket (min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 sqmm single core frlsh pvc insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using cm(1:3), including fixing ofswitch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of boq as supply only but cost of moudlar cover plate with frame and labour for fixing the same shall deemed to be included in the unit rate). 8 supply only modular switch 6amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 9 supply only modular switch 16amps,piano flush type, single pole, one way (1 module) complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 10 supply only modularsocket outlet 2 in 1, 6amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 11 supply only modularsocket outlet 5 in 1, 16amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by engineer-in-charge (laminated sheet top cover is included in point wiring). 12 supply and fixing ceiling rose, polycarbonate, isolated body, surface bakelite 2 to 3 terminal, 240 volts, 5/6 amp, isi marked complete all as specified and as directed by engineer-in-charge. 13 supply and fixingelectric calling bell ding dong type, ac 230 volts single pole including making elctric connection complete all as specified and as directed by engr-in-charge. 14 supply only modular bell push switch, piano flush type, 6amps, single pole, one way (1 module) fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) complete all as specified and as directed by engineer-in-charge. 15 supply and hanging /fixing ceiling fan 1200 mm sweep ac supply (input voltage range ; 120 to280v), bldc type, 5 star rated, bee and isi marked super enamelled, copper winding of b class insulation, single phase, maximum 30w (± 10%), temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 no blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified and as directed by engr-in-charge.note :- (i) serial number as issued by engr-in-charge of celing fan and ge office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account 16 supply and fixing exhaust fan (heavy duty) steel body, ac single phase 230v, 50hz, 900rpm, size 300mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core pvc insulated pvc sheathed copper conductor flexible cable 24/0.2mm drawn in flexible pvc conduit and hanging on wall with 4 nos steel fastners 12mm dia 200mm long and making good the disturbed surface complete all as specified and as directed by engineer-in-charge.note :- (i) serial number as issued by engr-in-charge of fan and ge office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) cost for making suitable cutting/opening in wall for fixing of exhaust fan including making good disturbed surface and masonary work shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. 17 supply and fixed for spn 8 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 18 supply and fixed for spn 6 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 19 supply and fixed for spn 4 way, 240 volt distribution board door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 amps, dust and vermin proof, ip-43 protected, suitable for incorporation of mcbs and isolators etc complete all as specified and as directed by engineer-in-charge. 20 supply and fixed for tpn distribution board 4 way vertical type double door made out of crca mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper bus bar suitable rating with neutral bar and earth bar and cable tie for cable management, ip-54 protection and provision and including mccb 4 pole 160 amp, 16 ka as incomer and mcbs as outgoing, dust and vermin proof complete all as specified and as directed by engineer-in-charge. 21 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, c curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 22 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 40 amps complete all as specified and as directed by engineer-in-charge. 23 supply and fixed of mcb suitable for 240 volts ac supply, spn with over load and short circuit protection and rupturing capacity not less than 10 ka, b curve as 6 to 32 amps complete all as specified and as directed by engineer-in-charge. 24 supply and fixing blanking plate of plastic suitable for any type of db complete all as specified and as directed by engineer-in-charge. 25 material and labour for submain wiring comprising single core, 2 runs of 4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 20mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x4.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 26 material and labour for submain wiring comprising single core, 2 runs of 6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 27 material and labour for submain wiring comprising single core, 2 runs of 10.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade drawing in and including pvc conduit of size min 25mm dia isi marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded frls copper conductor cable, pvc insulated unsheathed 1100 volts grade as earth wire and using color code as per is complete all as specified and as directed by engineer-in-charge. note : meter of pipe including fitting and 3 runs of single core cable shall be measured as unit runing meter. additional wire/cable required for connecting to mcb shall be included in overall cost quoted. 28 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing wire of size 4 mm dia by means of gi bolts/nuts/washers and protected by 15 mm bore gi light grade pipe upto test point or upto main switch board, ht/lt equipments, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 29 supply and fixing led tube light fitting polycarbonate housing 1 x 18/20watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g) aluminium housing & integrated electronic driver(h)led driver of the same make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection minimum 2.5 kv. (l) cct : minimum 6500k(m) cri : more than 80 (n) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 30 supply and fixing led tube light fitting polycarbonate housing 1 x 10watt, appx 2 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts.(c) temp operating range : minus 10°c to plus 45°c(d) power factor : minimum 0.95 (e) thd : current thd max10% and voltage thd max 5%(f) ip rating : ip-20.(g)led driver of the same make as of the luminaire.(h) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(j) surge protection minimum 2.5 kv. (k) cct : minimum 6500k(l) cri : more than 80 (m) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 31 supply and fixing led lamp 1x9 watt including pvc holder with complete suitable for fixation on wall/roof with body robust corrosion resistant, superior flnish and without any cracks of through holes complete all as specified and directed by engineer-in-charge 32 supply and fixing energy efficient led security light fitting of 35w pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street/roadway luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of gi tubing medium grade 32mm dia, 1.2 metre long bent to shape at 32 degree angle at half metre from bottom, including two nos clamps made out of ms flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to ms clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by engineer-in-charge :- (a) lumen system efficacy of luminaire should be minimum 100 lumen per watt.(b) input voltage range : 140 to 270 volts (c) temp operating range : minus 10°c to plus 50°c (d) power factor : minimum 0.95(e) thd : max10%.(f) ip rating : ip66. (g) ik rating:minimum ik07 (h) built in potted led driver of the make as of the luminaire.(j) led driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) surge protection 10 kv (inbuilt + extended) (l) cct : 5700 k. (m) cri: more than 80 (n) lens - high efficiency wide angle lens. (o) bis approved fixtures and driver (p) rated life time : 50000 burning hrs @l70 (average 10 to 12 hrs daily) 33 rigid non metallic pvc conduit 20mm dia (external) for sub main/telephone wiring inclusive of all fittings such as tees, bends, elbow, reducers, junction boxes bell mouth tube ends and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc complete all as specified and as directed by engineer-in-charge. 34 material and labour for mild steel boxflush mounted of size 100mm x100mmx100mm having holes for 20 mm conduit entry including 02 pin tv socket outlet flush type marked with symbol of tv and 03 mm thick plastic laminated sheeet cover and making good disturbed surfaces of walls by using cm (1:3)complete all as specified and as directed by engineer-in-charge 35 supply, installing, commissioning and testing of electric water heater (geyser) storage type abs body of capacity 25 litres, bee approved 5 star rating, 230 v , single phase, ac supply, inner tank made out of heavy duty stainless steel sheet (designed with single weld line, factory tested with hydraulic pressure as per latest is code) with glass lined coating complete with all accessories such as safety valve, thermostate, nrv, connection piece pvc connection 600mm long heavy duty suitable for hot and cold water, three core pvc insulated pvc sheathed copper conductor flexible cable, 04 nos suitable size mild steel l-hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by engr-in-charge. 36 supply and fixing for led light fitting 1x9w/1x10wbulkhead luminaires including led light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 37 supply and fixing earth continuity conductor or main earthing lead 32x6mm galvanised iron strip including nuts bolts and washer fixed to wall with saddles and fixing screws or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including making good disturbed surface complete all as specified and as directed.note :- (i) conduit/pipe as required, same shall be measured & paid separately under respective item of this sch/boq. 38 subtotal 39 lump sum price worked out by the tenderer for“internal water supply works as listed in schedule ‘a’ section - iii (part-i) 40 sch a sec - iii (part-ii), internal water supply works 41 supply and fixing two way bib cock/angle stop valve with flange, cast copper alloy chromium plated, screwed down high pressure with on/off handle screwed ends suitable for 15 mm bore pipe iron pipe or for brass ferrule/unions and fixed complete all as specified and as directed. 42 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 16 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 43 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 20 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq. 44 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 25 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 45 supply and fixing chlorinated polyvinyl chloride (cpvc) pipe heavy duty outer dia 40 mm having thermal stability for hot and cold water supply including all new cpvc fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including cpvc solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by engineer-in- charge. note :- cutting chases if required same shall be measured and paid separately under appropriate item of boq.note for cpvc pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by engr-in-charge. 46 supply and fixing single lever concealed diverter incl bath spout & shower complete all as specified and as directed by engineer-in-charge. 47 supply and fixing for brass chromium plated aquaguard/ro inlet valve or diverted valve with nozzle compatible for all type of water purifier fixing to steel pipe of socket of 15mm bore complete all as specified and as directed by engineer-in-charge. 48 supply and fixing for 40mm bore cpvc long handle vavle complete all as specified and as directed by engineer-in-charge. 49 supply and fixing health faucet fancy type, cp including 1.25 meter long 8mm dia flexible tube and including wall hook and fixing material complete all as specified and as directed by engineer-in-charge. 50 subtotal 51 lump sum price worked out by the tenderer for“road, pcc tiles andhume pipe culvert works) as listed in schedule ‘a’ section -iv (part-i) 52 sch a sec - iv (part-ii), road, pcc tiles andhume pipe culvert works 53 material and labour for premix bituminous concrete 40mm consolidated thicknesswith min 5.4 % binder content (bitumen of grade vg-30)by weight of total mix using sensor paver electronic sensing device for automatic leveling and profile control withi the specified toleranceand internal heating arrangement for the screed all as specified in table 500-17 of morth specification for road and bridge works 2013, rolled and compacted to required camber and gradient with tandem vibratory roller 8 to 12 tonne power roller to a uniform smooth surface complete all as specified and as directed by engineer-in-charge. 54 material and labour for thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads @ 8% by weight including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed by engineer-in-charge 55 supply and laying/fixing 80mm thick factory made chamfered edge cement concrete paver block of m-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 56 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 57 material and labour for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. 58 subtotal 59 lump sum price worked out by the tenderer for“(area drainageworks) as listed in schedule ‘a’ section -v 60 lump sum price worked out by the tenderer for“sewage disposal works as listed in schedule ‘a’ section - vi (part-i) 61 sch a sec - vi (part-ii), sewage disposal works 62 supply and laying dwcpe (sn8) drain pipes 180 (od)/163(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch 63 supply and laying dwcpe (sn8) drain pipes 200 (od)/175(id) mm dia pipe as per is-16098 (part-ii), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by engineer-in-charge.note : excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of sch. 64 subtotal 65 lump sum price worked out by the tenderer for“security fencing and gate works as listed in schedule ‘a’ section - vii 66 lump sum price worked out by the tenderer for “external water supply works as listed in schedule ‘a’ section-viii (part-i) 67 sch a sec - viii (part-ii),external water supply works 68 supplying, laying, jointing and testing ductileiron pipe (isi marked) class k-7, bore 150mm, confirming to is : 8329-2k, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (push-on joint) complete all as specified and as directed by engineer-in-charge.note : (i)earth work, di specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) test certificate for pipes from manufacturer shall be produced. no payment shall be entertained without test certificate. 69 supply and fixing cast iron sluice valve 150 mm dia with flanged ends class pn 1.6(heavy duty isi marked) confirming to is:14846-2000, drilled type, complete with stainless steel spindle, ci gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by engineer-in-charge. 70 material and labour for construction of brick masonary valve pit chamber size 90 x90 x90 cm (internal dimension) using sub class b bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, pcc (1:3:6) type c-2 using 40 mm graded stone aggregate in foundation, coping on top in pcc (1:2:4) type b-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, ms sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer and embeded portion of ms work duly applying black bitumenous paint before embeded complete all as specified and as directed by engineer-in-charge. 71 subtotal 72 lump sum price worked out by the tenderer for“external electrification and lightning protection works as listed in schedule ‘a’ section - ix (part-i) 73 sch a sec - ix (part-ii), external electrification and lightning protection works 74 supply and fixing lightning arresters ht 11000 v non linear expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, confirming to is 3070 (part-i) 1985 complete all as specified and as directed by engineer-in-charge. 75 supply, installing, commissioning & testing energy efficient transformer suitable for 315 kva (level-2) step down floor mounted outdoor type 11/0.433kv, 3 phase, 50 hz ac, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on hv side and star connected on lv side in accordance with vector symbol dyn-11 (vector group 4) with neutral brought out on lv side with for earthing and having tapping on hv side for constant output so as to alter/vary secondary voltage (tapping range + 5 %to - 10% in equal step of 2.5 % ) changed by means of manually operated off load taps changing gear. the voltage regulation shall be as per is including first fill of transformer oil as per is-335 and including all fittings/accessories. the limit of temperature rise after continuous full load run as specified in is-1180 (part-i) 2014 and bee certified shall be suitably adjusted to suit the maximum ambient temperature of 55 degree centigrade as prevalent complete all as specified and as directed and shall be comprised with the following fittings and accessories :- 76 (a) oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge. (b) silica gel breather with connecting pipe, first fill of dehydrating agent. (c) explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (d) air release valve plug (e) one cable box on lv side (secondary) consisting of 04 nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joints complete all as specified (f) explosive vent (g) 01 no 100 mm dial type thermometer vapor pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc. (h) thermometer pocket on tank cover (j) 04 nos plain solid ci detachable rollers (k) two nos earthing terminals marking plate. (l) rating plate and terminal marking plate(m) extra bushing for neutral outside the cable box brought out on lv side. (n) first filling of oil conforming to is and tested upto 60 kv dielectric strength (o) lifting lugs (p) oil drain valve with plug (q) one cable box on hv side (primary) consisting of 01 cable gland suitable for reception of taking in ht cable including gland joints complete all as specified (r) hand hole of sufficient size to assess interior of tank (s) dehydrating breather with first filling of dehydrating agent (t) two earthing terminal on tank body to facilitate fixing of 32x6mm gi strip. (u) rating plate with terminal marking plate (v) inspection cover. 77 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 78 (a) copper bus bar of 800 amp capacity, 4 strip mounted on porcelain insulators. (b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 500 amp (incomming).(c) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 25 ka, 125 amp - 07 (for 07 blocks).(d)mcb tpn 32 amps -01 nos (for street lights).(e) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(f) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (g) ryb led indicating lamp set of three -01. 79 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 80 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 36 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 32 amp - 16 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-400amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 81 supply, installation, commissioning and testing of factory made (cpri approved) lt panel board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 volts, dust proof, vermin proof made out of crca sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick crca sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of pcc (1:2:4) type b-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for lt with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by engr-in-charge and comprising of following accessories:- 82 (a)aluminium bus bar cap 150 amp capacity with heat shrinkable pvc colour sleeves - 04 nos.(b) mccb 4 pole with thermal magnetic release adjustable type with breaking capacity 16 ka, 100 amp (incomming).(c) mcb spn with thermal magnetic release adjustable type with breaking capacity 16 ka, 20 amp - 07 (outgoing).(d) digital voltmeter 96x96mm flush secure panel mounting type 0-500v with selector switch -01.(e) digital amp meter 96x96mm flush secure panel mounting type 0-100amp with selector switch with ct -01. (f) ryb led indicating lamp set of three -01. 83 supply and fixing cable junction box of size 280mm x 200mm x100mm or any other higher size (suitable for pole mounting) complete with fixing accessories. junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. the polycarbonate junction box shall be environment frinedly, recyclable, uv resistant, halogen and silicon free, anti acid and anti corrosive. the junction box knock out on four side wall and following specifications and all as directed by engr-in-charge :-(a) the junction box shall be rated for degree ofip 65 (ingress protection) in accordance with iec 60529.(b) the gasket material shall be polyurethane or silicon and gasket shall be internally embedded.(c) junction box must meet the provision laid down in iec 60998-1, iec-60695-22, iec 60670-2 to 5 and grey color according to ral-9011/ 7035.(d) the manufacturer of junction box shall submit a copy of iec certificate and glow wire test for 960 degree.(e)junction box shall be fire retardant and self extiguishing in accordance with iec60695-2 to 11, din vde 0304 part-3, ul94 v-2 flammability standard. (f) the impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with en 50298-98 for ik08.(g) junction box shall have 4 pole tinned copper bus bar of size 25mmx3mm complete with one number 20amp mcb sp 10ka (h) manufacturer should submit routine test certificate for junction box. (j) suitable size of mild steel clamps and screws/nut bolt shall be used for fixing of junction box.. 84 material and labour for earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including giearthing strip 32x6mm by means of gi bolts/nuts/washers and protected by 40 mm bore gi light grade pipe upto 7.5 mtr length, fixing with 02 nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore gi medium grade pipe for watering and including funnel, wire mesh, pcc chamber pit made with pcc (1:3:6) type c1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,pit cover 40mm thick made with rcc (1:2:4) type b1 (using 20 mm graded stone aggregate) including tmt reinforcement 8mm dia @ 75mm c/c both way, ms handle 12mm dia, cover rest on ms angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate no. 3 ofssr 2009 (part-i) complete all as specified and as directed by engineer-in-charge.note:- (i) pcc chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) protection pipe and gi earthing strip upto 7.5 mtr from top of earth plate shall be included in the unit rate of this item. (iii) the earth testing arrangement should be done by the contractor as per direction of engineer-in-charge. 85 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 86 s&f for gi steel light grade 32 mm dia bent to shape of offset angle upto 45 degree for fixing of security light fitting gi pipe 1.5 mtrs including ms clamp and nut bolts complete all as specified and as directed by engr-in-charge. 87 subtotal 88 sch a sec - x, fire fighting eqpt works 89 supply and fixing fire hydrant landing valve type a (double head outlet) gunmetal of 65 mm dia with 63 mm dia female outlet complete and 65 mm inlet with rubber blank cap and chain as per is 5290-1983, suitable for brigade hose of 63 mm with couplings conforming to is 903 (for internal hydrant at ground floor to 3rd floor and roof) complete all as specified and as directed. 90 supply, installing, commissioning and testing of fire hose cabinet to be mounted externally near the hydrant post fabricated from 16 swg mssteel of appox size 800 mm x 600 mm x 450 mm with a canopy, door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accommodate one hydrant valve, one branch nozzle and 30 mtrs hose reel, weather proof, finished with and including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer ( sample to be approved prior to entire supply) complete all as specified and as directed. 91 supply, installing, commissioning and testingof wall mounting swinging type first aid firehose reel with drum, hanging bracket, 30 mtr long and20mm dia high pressure hose reel as per is 444 with gunmetal shut off nozzle having 5mm dia orifice. the hose reel shall be conforming to is 884-1985. drum shall be fixed on adjoining wall through anchor fasteners/cement concrete book or ms stand as per site requirement complete all as specified and as directed. 92 supply, installing, commissioning and testing of 63mm dia gun metal, short type, instantaneous pattern branch pipe to suit fire hose delivery coupling of 63 mm size complete with gm nozzle of 20 mm nominal size conforming to is 8090 complete all as specified and as directed. 93 supply, installing, commissioning and testing of gun metal body butterfly valves of size 63mm dia, is:210, pn-16, confirming to is:13095 complete all as specified and as directed. 94 supply, installing, commissioning and testing of booster pump 30 m head, 450lpm discharge, 440 v, 3 phase, 50hz confirming to is- 12469 :1988 with ci casing bronze impeller and stainless steel shaft mounted on heavy duty bearings complete all as specified and as directed. 95 supply, installing, commissioning and testing 65mm nominal bore, wall thickness 6mm, ms heavy duty (c class) flanged pipe, isi marked (is : 1239) with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer complete all as specified and as directed. 96 supply and fixing trolley mounted water stored pressure type fire extinguishers, 9 ltr capacity conforming to is:13386 with extinguishing agent :water+afff and propelling nitrogen gas, wall bracket handle fitted with high pressure flexible discharge hose with discharge throw of 2-5 mtrs.,with isi certification markcomplete all as specified and as directed. 97 supply and fixing carbon-di-oxide 3 kgs capacity fire extinguisher (light weight squeeze grip type) fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn, and cylinder bearing no., confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 98 supply and fixing dry chemical powder fire extinguisher ( abc powder ) 9 kgs capacity stored pressure type, ce mark valve with nrv & safety release provision with epdm rubber hose, the extinguisher is internally coated with epoxy polyester and externally coated with pure polyester powder and confirming to is:15683:2006. fire rating 3a: 89b, isi certification mark complete all as specified and as directed. 99 supply and fixing mechanical foam extinguisher of 9 ltr capacity and confirming to is:15683:2006 complete all as specified and as directed. 100 supply and fixing fire buckets (dry sand)of 7 kg capacity including hanging arrangements complete all as specified and as directed. 101 supply and fixing emergency exit sign board with double side adhesive tape vinyl sticker with forex board (green and white colour) 30 cm x 10 cm complete all as specified and directed. 102 subtotal 103 lump sum price worked out by the tenderer for“lift works as listed in schedule ‘a’ section - xi (part-i) 104 sch a sec - xi (part-ii), (lift works) 105 supply, installing, commissioning and testing 13 passenger lift, having 1.0 m/s car speed, gearless motor suitable for 3- ph, 415 v, 50 hz electric power supply, conforming to is-14665, suitable to serve g + 3 upper floors with ac variable voltage & variable frequency drive (vvvf drive), complete with all standard accessories, simplex full collective operation, centre opening doors with door drive, sliding stainless steel doors, automatic rescue device (ard) system, 2d infrared sensor in full height of door & built in press and speak 3 way intercom. complete all as specified and as directed and shall conform to the following specifications: 106 type of lift : passenger lift 107 capacity of lift : 884 kg, 13 person 108 rise : up to g+3 bldg 109 stop and opening - 04 stops with all opening on the same side 110 controller type : microprocessor based 111 drive : ac vvvf drive 112 power supply : 400/415 volts (3 phase ac) 113 operation : full collective operation 114 car group : simplex type 115 machine : gearless motor located above shaft in machine room 116 traction media : steel rope 117 car finish : rear mid panel, rear corner panel, side mid panels, side corner panels, front panels all are made of stainless steel ss304 with honey comb finish 118 false ceiling finish : stainless steel with hairline finish and with provision for led lights specified here-in-after. 119 ventilation : pvc heavy duty cross flow fans 120 hand rails : stainless steel finish round handrails on rear car panels 121 flooring :20mm thick granite to be provided in the recess car cabin floor and fixing with suitable adhesive over aluminium chequered plate in one piece minimum 3mm thick. 122 car door and landing door finish : stainless steel ss-304, mirror finish outside 123 fire rated doors : fire rating - 60 minutes 124 pit depth: 1600 125 overhead : 4500 126 hoistway dimensions(w x d – mm) : 2500 mm w x 1900 mm d 127 car size (w x d x h - mm) : as per is-14665 (part 3 sec-i) : 2000, height 2200 mm 128 car & hoistway door type : central opening (co) doors 129 door opening (w x h - mm) : 900 mm w x 2000 mm h 130 door operator : vf 131 cop : cop (car operating panel) and lop (landing operating panel) in stainless steel hairline finish with display. 132 car position indicator : dot matrix type 133 hall fixtures : dot matrix type 134 hall fixture face plate : stainless steel hairline finish-ss-304 135 hall button arrangement: hall and call buttons with illumination and braille 136 car and counter weight guide as per oem recommendation 137 terminal buffers metal spring/oil buffer as per oem recommendation 138 standard features :anti-nuisance car call protection, independent service, overload device, nudging, emergency car light unit, infrared curtain door protection, door time protection, emergency alarm button, extra door time of lobby & parking door open/close button, manual rescue operation, auto fan cut off, over speed governor for car 139 also included : emergency firemen’s service, automatic rescue operation, intercom. 140 car enclosure: manufactured with stainless steel frame not less than 1.5mm with honey combfinish (ss-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with led sleek light fittings (as per manufacturer’s instructions, minimum 04 nos) operated on commercial supply and one led light fitting operated on battery with inverter as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection 141 floor announcement system in car cabin 142 signals: (a) combined luminous hall buttons with led hall position indicators at all floors (b) led car position indicator panel of stainless steel (c) car operating panel of stainless steel with luminous buttons in car (d) car direction indicator in car & landing (e) battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (the system shall be separate from ard batteries.) (f) overload warning feature in car cabin (display / announcing type both) (g) one firemans switch to be installed at ground floor near landing door. (h) all signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (j) infrared door sensor safety edge of door for entire height. 143 safety device: (a) automatic rescue device (ard) / automatic landing device operating with maintenance-free batteries having suitable capacity. the batteries must have auto charging facilities. (b) the ard actuation time shall be less than one second after failure of power supply and when ard is operative the car shall stop at the nearest floor and then doors shall open. 144 operation: simplex, full collective automatic operation 145 machine room: located above the hoist way, details as per building drawings 146 hoist way: construction details as per building drawings 147 civil work: necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. 148 one number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. the telephone instrument shall be connected in the telephone db installed in the machine room 149 looking mirror of size 1200x900mm, 5.5mm thick to be provided on rear panel wall (opposite to main door) of car cabin above hand rail 150 provision of suitable size of copper conductor xlpe insulated cable from lift panel installed at ground floor to machine room will deemed to be included the rate quoted by the contractor 151 subtotal 152 lump sum price worked out by the tenderer for“excavation, earthwork and site development works as listed in schedule ‘a’ section - xii 153 schedule a section -xiii (furniture works) 154 almirah small steel as per drawing no. fd-1032 sheet no. 1/1 155 book shelf open (large) steel as per drawing no. fd-69(m) sheet no. 1/1 156 bed hard as per drawing no. fd/e6/map/08(r) sheet no. 1/1 157 chair verandah as per drawing no. fd/e6/map/11 sheet no. 1/1 158 charpoy folding ip with hard top as per drawing no. fd-388(r) sheet no 1/1 159 peg table as per drawing no. fd/map/11 sheet no. 1/1 160 rack shoe steel as per drawing no. fd/e6/map/02(r) sheet no. 1/1 161 table bed side as per drawing no. fd/e6/map/15(r) sheet no. 1/1 162 table centre as per drawing no. fd/map/08 sheet no. 1/1 163 dressing table including stool as per drawing no. fd/map-ii/07 sheet nos 1/2 & 2/2 164 chair dining jcos/ors as per drawing no. fd/map-ii/05 sheet no. 1/1 165 chair easy per drawing no. fd-229 sheet no. 1/1 166 chair writing as per drawing no. fd-280 sheet no. 1/1 167 charpoy with hard top as per drawing no. fd/map-ii/01 sheet no. 1/1 168 mirror dressing(gents) as per drawing no. fd/e6/map/16 sheet no. 1/1 169 table dining 4 persons as per drawing no. fd/map-ii/03 sheet no. 1/1 170 table with drawer (900 mm x 600 mm x 760 mm) as per drawing no. fd-283 sheet no. 1/1 171 chair school with hand board as per drawing no. fd/e6/map/05 sheet no. 1/1 172 note:-quantities of materials given on standard drawings are for guidance only. the contractor shall work out the quantities of materials required for each item of boq and quote his rate accordingly no claim shall be entertained on account of inaccuracy in the quantities of these materials and workman ship which shall be as specified in particular specifications and as approved. the drawing nos mentioned in boq item no 184 to 264 shall form part of tender document which will not be attached with tender document. the tenderers are deemed to be in possession and conversant fully with the drawing shown in standard furniture designs including amendments published by ahq, engineer-in -chief, new delhi. for reference and guidance the tenderer may study and see these drawings in the any office ofgarrison engineer in mes before quoting their rates. no claim shall be entertained regarding misinterpretation of the drawings at a later stage. 173 subtotal 174 lump sum price worked out by the tenderer for“arboriculture works as listed in schedule ‘a’ section - xiv (part-i) 175 schedule a section -xiv (part-ii) (arboriculture works) 176 material and labour for grassing with selection no.1 grass including enough watering and maintance of the lawn till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed including supplying and spreading of neem oil cakes, manure or sludge and chemical required for preparation of the ground for plantation of grass complete all as specified and as directed. 177 supply and planting of hedge and shrubbery (anarmi, ficus and the like) as directed by engineer-in-charge minimum 3 feet above gl including creation of beds by excavating 60 cm deep and 60 cm wide trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio 8:1 (8 part of stacked volume of earth after reduction of 20 % with 1 part of stacked volume of sludge or manure ater reduction by 8%) flooding with water filling with earth if necessary, watering and finally fine dressing leveling etc including stacking and disposal of material declared unserviceable and surplus earth by spreading and leveling as directed within a lead 50 m and lift upto 1.50 m complete all as specified and as directed. 178 supply and laying/fixing 60mm thick factory made chamfered edge cement concrete paver block of m-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by engineer-in-chargenote:- tiles shall be approved by ge before incorporation in the work. 179 material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.note:- (i) punned thickness shall be considered for payment purpose (ii) approved sand free from vegetations, grass and other deleterious substances shall be used. 180 supply and laying factory made kerb stone of size 30x15x45cm of m-25 grade cement concrete laid in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement:3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed by engineer-in-charge 181 supplying following plants in poly bags 0.25 m to 0.30m dia with height 1.20 m to 1.80 m including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 2:1(2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludgeor manure after reduction by 8%) flooding with water and removal of surplus soil, with & including antitermite treatment using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 182 neem tree. 183 canerydate palm 184 gulmohar 185 fruit bearing trees 186 plumeria 187 supplying plants flower like ticoma, rose,motia, chandni, lxora, marigold rose, vinca (any colour) as directed of height not less than 0.60m above gl including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 3:1(one part of manure & 3 part of soil) manure 200 gm per plant ,flooding with water and removal of surplus soil n.exc 1.50 km and depositing where directed with & including using suitable chemicals or pesticides of approved quality, as required and making thaola all as specified and as directed by engineer-in-charge.note :- contractor shall maintain the trees till physical completion of contract.unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 188 supply and fixing precast rcc 1:1.5:3 type a1 lawn bench and backsupport of size 1.50 x 0.60m of maximum three person seating capacity supporting precast rcc type a1 for back and base with including assemble the precast member with suitable nutt & bolt and placing and anchoring with hold fast 350mm - 16mm dia ms bar on concrete base (size 1.20x0.60m for each support) with 100mm thick pcc 1:2:4 type b1 over 150mm thick sub base pcc 1:4:8 type d2 complete all as specified and as directed by engineer-in charge 189 subtotal 190 schedule a section -xv ( maintance) 191 material and labour for the plants/hedge/grass by weeding, hosing, saucer making once in every month for plants/hedge, once in every 15 days for carpet grass/country grass/doob grass, bermuda grass, pruning dired ranches once in every week, depositing the material at place of dead plants of same species and height turning with dods whenever required by replacing the dead patches of grass of any type with same grass as required without any extra cost to the department all as specified and as directed. (plants of various species -678 nos (approx), hedge and shruery - 520 rm (approx) and grass - 4000 sqm( approx) 192 subtotal
  • View Tender
  • Document
  • Bid Support
2 Security Services
image image
Central Government/Public Sector
TRN :49054604 |  13 Jun, 2025
Tender Value : 70.50 Crore
 Kochi - Goa
Tender for tender for provision of cgsd (kochi) at willingdon island, kochi; 1 schedule a part - i (building & structure works)details of prepriced schedule is given in tender documents. 2 schedule a part-ii ( site clearence/development & earth works) details of prepriced schedule is given in tender documents. 3 schedule a part-iii (internal water supply) details of prepriced schedule is given in tender documents. 4 schedule a part-iv (internal electrification) details of prepriced schedule is given in tender documents. 5 schedule a part-v (fire fighting)details of prepriced schedule is given in tender documents. 6 schedule a part-vi (road/path/ hard standing/culvert)details of prepriced schedule is given in tender documents. 7 schedule a part-vii (external water supply) details of prepriced schedule is given in tender documents. 8 schedule a part-viii (external electrification) details of prepriced schedule is given in tender documents. 9 schedule a part-ix (sewage disposal) details of prepriced schedule is given in tender documents. 10 schedule a part-x (area drainage) details of prepriced schedule is given in tender documents. 11 schedule a part-xi (compound wall) details of prepriced schedule is given in tender documents. 12 schedule a part-xii (organic waste converter and smart energy meter) details of prepriced schedule is given in tender documents. 13 schedule a part -xiii (miscellanious items) note:- this schedule is not pre-priced by mes and the pre-priced rate indicated as rs 0.00 under col. e signifies this fact only. 14 internal water supply s & f for 15 mm dia bore cp two way bib cock with cp wall flange (make : jaquar model no. opp15041pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 15 s & f for 15 mm dia bore cp bib cock with cp wall flange (make : jaquar model no. opp15037pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 16 s & f for 20 mm bore concealed stop cock reqular brass body with spindle extnwith exposed part kit of concealed stop cock with fitting sleeve, operating lever & adjustable wall flange (compatible with ald-083cqt & ald-089cqt)(make : jaquar model no. ald 089 cqt/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 17 s & f for 25 mm dia bore concealed stop cock reqular brass body with spindle extn with flush cock & wall flange 25mm ceramic disc cartridge) with plain knob (make : jaquar model no. ald 081/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 18 s & f 20mm bore cp angular stop cock with cp wall flange (make : jaquar model no. cqt 23053 / eqvlt in kohler/grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 s & f for 100 mm overhead shower rose round shape single flow (abs body chrome plated with gray face plate (make : jaquar model no. 1989 with sha 479l300s / eqvlt in kohler/ ess ess) with shower arm ø20mm & 300mm long round shape with 90° bend for wall mounted showers with stainless steel connected to pipe complete all as specified and directed by engr-in-charge. 20 cooling appliancesdesign, supply, installation, testing and commissioning of invertor type floor mounted packaged ac units of specified capacities, combination of energy efficient inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include group controller also asrequired for controlling ac from a single point and timer option for load sharing of ac units complete all as specified and as directed by engineer - in - charge, of following capacities.note: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. (high side (machines))(outdoor unit) 21 a) 22 tr inverter package ac units 22 b) 16.5 tr inverter package ac unit 23 design, supply, installation, testing and commissioning of normal type floor mounted packaged ac units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include support works for outdoor units with necessary catwalk for service access complete all as specified and as directed by engineer - in - charge, of following capacitiesnote: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. low side (machines))(indoor unit) 24 a) 22 tr inverter package ac units 25 b) 16.5 tr inverter package ac unit 26 supply, installation and testing of refrigerant pipingwith necessary clamping (suction & discharge) hard/soft drawn copper tube of suitable sizes, with copper elbows, tees, tubular nitrile insulations etc as required complete all as specified and as directed by engineer - in - charge. 27 s & f control cabling b/w indoor & outdoor units 28 m & l refrigerant gas - r410a 29 supply, installation and testing of hard pvc drain piping. drain piping with tubular nitrile rubber insulation: complete in all respects, well clamped till drain points complete all as specified and as directed by engineer - in - charge. for all units 30 ductingsupply, fabrication, installation, testing of gi rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per is 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by engineer - in - charge. 31 a) using 0.63 mm (24 gauge) gi sheet 32 b) using 0.80 mm (22 gauge) gi sheet 33 c) using 1.00 mm (20 gauge) gi sheet 34 duct insulation & liningsupply and installation of acoustic insulation of ducts using 9mm open cell nitrile rubber, well adhesived, 150 - 180 kg/cm2 complete all as specified and as directed by engineer - in - charge. 35 supply, installation & testing of thermal insulation of ducts using 9mm closed cell nitrile rubber, well adhesived, 40-60 kg/cm2 complete all as specified and as directed by engineer - in - charge. 36 s & f canvas connection 37 air distribution productssupply and fixing of powder coated aluminium grills/ diffusers (supply/ return) complete all as specified and as directed by engineer - in - charge. 38 s & f collar dampers 39 supply and installation of fire dampers complete all as specified and as directed by engineer - in - charge. 40 supply, installation, testing and commissioning of heater bank plus humidistat arrangement complete all as specified and as directed by engineer - in - charge. 41 supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier hima 7 nhc, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, ac power supply with all connecting accessories complete all as specified and directed. 42 supply and fixrefrigerator, electric driven (single phase), 220 v,50 hz, capacity 195 litres, 3 star rated direct cool inverter, single door all as specified and directed by the engineer-in-charge. 43 supply and install, testing and commissioning of split type air conditioner 1.5 tr capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (cooling appliances- qty 4, air conditioning- qty 10) 44 supply and fix voltage stabilizer 3 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% 45 supply and fix voltage stabilizer 4 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% (cooling appliances-qty4, air conditioning- qty 10) 46 air conditioningsupply and install,testing & commissioning of split type air conditioner 2 tr capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 supply and fix voltage stabilizer 5 kva for automatic operation,single phase naturally air cooled indoor type, wall mounted type & designed for input variation between 170 v to 280 v with output voltage stabilized at230 v with accuracy of ± 2.5% 48 internal electrifications & f led mirror light 1 x 5w lumos ecco 1 feet make: luker or equivalent 49 s & f modular mcb dbox 3 pin socket with mcb sp 20 amp, 240 v including plastic enclosure as per manufacturer instruction fixed on wall surface complete for air conditioner all as specified and as directed. (make:-havells, model-dhdmcsn0251016 or equivalent) 50 supply and fix air circulator of 600 mm sweep ac single phase. 230v, 1440 rpm complete all as specified and as directed. (make: havells model, turbo force wall or equivalent) 51 s & fvertical triple pole & neutral (vtpn), double door, 16-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 52 s & fvertical triple pole & neutral (vtpn), double door, 4-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 53 m & l for flame proofmcb distribution board spn 12 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb -10 nos as outgoingcomplete all as specified and as directed. 54 m & l for flame proofmcb distribution board spn 8 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb- 6 nos as outgoingcomplete all as specified and as directed. 55 supply and fix engage light with green & red led complete all as specified and as directed 56 supply and fix of cs mounted high intensity led search light, long range, manually swivel in all direction, 250 w, minimum range 700 meters, single, led efficiency> 140 lm/w, pf> 0.95, cct 5500k - 6500k, optical grade pmma/pc lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti uv, narrow beam 5 degree, die cast lm6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree c, input volt 100-300 vac, 50 hz, pf >0.95, ip-66, confirming to lm79/ lm80 and type tested as per is: 10322/ is: 13383, bis approved and govt lab tested for lux intensity. the search light is completed with manual revolving cs stand d20cm x h15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. model no. cs-lrfll-25pc25 of kalin make or equivalent 57 supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, enystar emptyenclosures, ip-65, weatherproof, corrosion free, halogen and silicon free, frame retardant with opaque lid size-[276 x 546 x 186]mm and transparent hinged lid, completed all as specified and directed. 58 m & l for tv socket module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 59 m & l for telephone jack with module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 60 supply and lay coaxial cable for tv cabledrawn through conduit 61 s & f flame proof exhaust fan 300 mm sweep, single phase, 1440 rpm complete all as specified and as directed. 62 fire fightingsupply and fix foot valve conforming to is 4038, 100 mmdia. 63 supply and fix foot valve conforming to is 4038, 150 mmdia. 64 supply and fix cast iron air valves with single air outlets, conforming to is 14845 of size 100 mm dia bore and fixing up in cast iron water supply mains of size 100 mm dia. 65 s & f sprinkler flexible drop pipe 1 mtr long. 66 s & f sprinkler rossette 25 mm dia. 67 supply and installation, testing and commissioning of analog addressable type active loop repeater (loop power/external power) fire terminal with inbuit turbo isolator, backlit lcd display 6x40 characters display, having controls for reset, mute, accept, silence alarms and self test, with programmable free keys and duly approved byen54/lpcb/vds/fm make: siemens/notifier/bosch 68 m & l for low smoke zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to bs7629-i, bs6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier type lt53 outer sheath confirming to bs 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 staircase signage down of make bajaj cat part no. 111499 model no. dsdwbb 3w double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 s & f wall mounted led emergency exit signage luminaire lit up using regular mains supply comes with a unique rechargeable ni-cd battery capable of emergency back up upto 05 hours(cat no. 220211 make bajaj or equivalent to cg/havells. 71 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board , made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and comprising of the following:- make of mccb/mcb -mds/legrand/l&t/hegger (main fire fighting panel)incoming(i) mccb 4 pole 160 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release - 01 no.(ii) voltmeter digital type 0-500 volts range flush type with selector switch- 01 no(iii) aluminium bus bar tpn - 200 amps- 1setoutgoing(i) mccb 3 pole 125 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release- 01 no.(iii) mcb tpn 32 amp -02 nos(iv) 80 hp s/d starter- 01 nos(v) dol starter 7.5 hp- 01 nos(vi) motor protection relay32-88 amps- 1 no. (vii) motor protection relay2-5.5 amps- 1 no. (viii) on/off/trip indication lamps, 220 v ac- 6 nos.(ix) start/stop push button, 2 no. (x) phase indicating lamps ryb for incoming and each outgoing connection.(xi) digital type ammeter 0- 150 amps with selector switch and ct coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 m & l for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per is-10221.the coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per is specification 73 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board, made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and & directedby engr-in-charge comprising of the following :– ( booster terrace pump panel)incoming:-(a) incoming mccb 40 a 25 ka, 4 pole- 01 no.(b) busbar tpn of size 100 apms - 1 setoutgoings:-(a) mcb 3 pole tpn 32 amps,10 ka-2 nos.(b)dol starter for 7.5 hp pump set-1 nos.(c) ammeter class-1, digital panel mounting type 96mmx96mm l & t cat no wds301fca00 including ct 50x5 amps 3 nos & selector switch-4 nos(d) voltmeter class- 1, digital panel mounting type 96mmx96mm l&t cat no.wds301fev00 & selector switch - 1 no.(e) led type indicator lamp 1 set (set of three for r,y,b)(f) mini protecrionrelay 4-11 amp - 1 nos. 74 fire extinguisher mechanical foam type trolly mouted of 9 liters capacity. ceasefire 9 litrs fire extinguisher afff foam type, external cartridge type, pressure guage gross weight 14.6 kg, empty weight5.6 kg, can height 611 mm, diameter 175 mm, discharge time less than 60 secs controllable discharge mechanism, minimum 6 mtrs, applicable on class a, b, can construction deep down & co2 mig welded valve construction: forging & machining, internal coating of can: epoxy powder coating, external coating of can: epoxy poyster powder coating sheet metal thickness 2.0mm,1 year warranty. make cease fire or equivalent. (pol store) 75 supply, installation,testing & commissioning of carbon dioxide (co2) type fire extinguisher of 4.5 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 76 supply, installation,testing & commissioning ofdry chemical powder (abc) stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 77 supply, installation,testing & commissioning of water mist high pressure stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 78 supply and installation at approved location approved make fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & showel etc, complete. 79 special equipments for storesdesign, manufacture, supply, installation, testing and commissioning of automated storage and retrieval system with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. automated storage and retrieval system shall consist of computer controlled & plc stacker crane driven system for automatically placing & retrieving materials from defined storage locations. the crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 kg (max) complete all as specified and directed by the engineer-in-charge. technical data for design of heavy duty asrs:-(a) dimensions:-height:10 mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)storage capacity:-pallet size: 1300 (w) x 1200(d) x 1250 (h) in mmpallet nos.: 480pallet load capacity: 1125 kgtotal capacity: 540 tons(c) stacker crane: single mast automated stacker crane for handling pallet, size 1300mm(w) x 1200mm (d) x 1250mm (h) and pay load (including pallet self weight) of 1125 kg max. the stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. stacker crane will be mounted on single rail at the bottom to traverse the length of the storage system. a single top rail mounted on the racking system shall also support it.general technical parameters of stacker crane:technical parameters/type- single mast(i) operation mode (networking)- on-line automatic / single automatic (ground/boarding) /manual operation (boarding) / maintenance (ii) communication means- wireless 80 (iii) power supply mode- 380 to 415 v, 50 hz, three phase five wire (iv) addressing mode- horizontal and verticle operation: photo electrical sensor + bar code scanners(v) positioning / reduction accuracy (mm) level- lifting ± 3 - 5, fork : ± 3(vi) fork unit- 1 double deep fork(vii) load unit- ms pallet (viii) total height- 10 mtr(ix) the normal lifting speed (m/min) - 10 mpm(x) the normal running speed (m/min) - 65 mpm(xi) rated load- 1125 kg(xii) receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- conveyor(d) pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 kg at height up to the last loading level in the racking system. it should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.pallet details:-(i) dimensions - 1300mm(w) x 1200mm(d)(ii) pallet height- 1250 mm(e) racking system :- two aisle having two row racking system each with 05 verticle levels for storage of material. racking for double deep type storage of 480 pallet of size 1300mm(w) x 1200mm (d) x 1250mm (h). loaded pallet weight: pay load with pallet 1125 kg max. system details:-working aisle -01 nos. (double deep)store rack -24 nos./rowtotal rack in 1 aisle-24 (left) + 24 (right)= 48 nos.no. of level- 5 nos/racktotal pallet-48 x 5 x 2 = 480 nos.load capacity- 1125 kg/levelsingle mast stacker crane-01 no. 81 (f)aisle equipment:-this will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. the mechanical aisle equipment of bottom rail shall consist of i beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. top rail shall be mounted on the racking. the electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) details of rack members:-the racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) loading- unloading station/ conveyor(i) pallet load 1125 kg max.(ii) bearing- skf equivalent make(iii) motor- seimens/sew euro drive/nord sew/ bonfiglioli or equivalent(iv) gear box- bonfiglioli make or equivalent(v) v.f.d.- yashkawa make or equivalent(j) all steel surface shall be powder coated finish with 8 tank treatment process.(k) maintenence: the annual maintenence of complete asrs system duyring the defect liability period of two years shall be included in the rate quoted for the system and the amc contract duly signed with the manufacturer of the asrs system shall be submitted at the time of handling over the system. the amc shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountnote- 1mechanical safety provision (i) end of aisle shock absorbers / bumpers for stacker crane.(ii) end of travel buffer for the lifting crane.(iii) safety catches on lifting carriage.(iv) anti-tilt mechanism for the stacker crane.(v) continuous rail cleaning brush for floor rail.(vi) adjustable rail clamp to ensure alignment. 82 (vii) resilient rubber pads on adjustable clamps for vibration dampening.(viii) profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. note - 2 electrical safety provision (i) there shall be emergency stop push button at all panels and stations.(ii) optical light beam amd mechanical safety sensor to stop the operation in case of improper storage or obstruction in the operator window either internal or external reasons like operator hand or material placed at edge of the tray.(iii) back up circuitry for proper system operation.(iv) an electromagnetic brake shall be used to avoid the slippage of the hoist.(v) stopper shall be provided for the maintenance door.(vi) load cells shall be provided for the over weight of tray.(vii) automatic door shall be provided for operator safety while machine in operating condition.note - 3 physical safety provision (i) the asrs system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. height of the fencing should be minimum 2.0 meter.(ii) one no. of electromagnetic aisle access door shall be provided. it should cover the complete length of the system on one side.(iii) a manual locking system to restrict the movement of unauthorised personnel shall be provided.note: design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. item no. 13.070 below shall be compatible with this item/ system and both should be integratedmake of asr system:armstrong ltd/ godrej koerber/ kardex india storage solutions pvt ltd/ daifuku india pvt ltd/ addverb technologies ltd/ craftsman automation ltd/ tech-mark 83 supply, installation, testing and commissioning of advance inventory management system with computer hardware with compatible inventory software complete all as specified and directed by the engineer-in-charge. technical specification of the system(i) system height : 6400 (±100) mm(ii) system width : 3150 (±100) mm(iii) system depth : 2300 (±100) mm(iv) system base : 7.24 sq.mtr(v) tray int. size: 300 (h) x 2450(w) x 500 (d) in mm(vi) tray dead weight - 57 kg (approx.)(vii) per tray weight capacity - 300 kgtechnical specification of the system:-(viii) tray quantity : 32 nos.(ix) usable net load - 9.6 ton(x) storage surface area per system - 39.2 sq mtr(xi) door - automatic(xii) power consumption - 3.7 kw(xiii) power supply - 440v, 50/60 hz, 3 phase(xiv) motor 3 phase 1440 rpm - seimens make or equivalent(xv) chain - diamond makeor equivalent(xvi) bearing - skf/ntn make or equivalent(xvii) external cladding - epoxy powder coatedsafety features:1. photo curtain at access port, 2. motor protection relays, 3. limit switch at door, 4. single phase preventer,5. switch mode power supply, 6. 15 min battery backup for plc, 7. noise less than 60db, 8. emergency stop various safety alertsnote: the system and software provided under this item shall be of same make as for item 13.069 or a compatible system and software as recommended by the chosen manufacturer of asr system. this system shall be integrated with asr system. 84 supply, installation and testing of car traffic boom barrier 6 mtr suitable to working on power supply 230 volt, 50 hz, 24v dc electric motor, adjustable with cams, operating ambient temperature from -20 to +55 degree celsius, uses cycle 2000/day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 nm open/close time 2 to 4 sec complete all as specified and as directed by engineer-in- charge.make: faac/parkilo/skidata/bft 85 external water supplysupply and fix foot valve conforming to is,100 mm dia complete all as specified and directed. 86 supply and fix cast iron air release valve with 100 mm bore and two outlets as per is:14845 complete all as specified and directed. 87 supply, installing, testing and commissioning of electrically driven horizontal centrifugal pump set 9.0 lps at 50 meter head as per specification, motor tefc type, 2880 rpm, 415 v, 50 hz, 3 phase, class f insulation, ip 55 protection, starting on suitable star delta starter. the pump shall be horizontal, end suction, top discharge. the pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on rcc (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 lpm at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, pvc insulated copper cable connection from starter to the motor terminals all as specified and directed by the engineer-in-charge.(01 no. working + 01 no stand by)make:- kirloskar brothers/crompton or equivalent. 88 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.0 mm thick crca sheet, cpri approved having, ip 43, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply, bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2.0 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: lt panel for pump house. the lt panel comprising of the following:- 89 incoming:-mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, breaking capacity 36 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 01 sets(b) digital multi function meter - 01 no.(c) cts - 100/5a, cl-1, 15 va - 01 set(d) horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 350 amps for phase and 350 amp for the neutral baroutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 16 ka- 02 no. ics =100% icu -2 nos.(b) mcb, tpn 40 amp, 415 volt, c curve - 02 nos.(c) star delta starter 12.5 hp, 3 phase, 415 volt- 02 nos.(d ) digital ammeter - 2nos.(e) single phase preventer - 2 nos. 90 m & l valve chamber of internal size 0.90m x 0.90m x 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick pcc in 1:4:8 type d2 foundation, brick work in cm 1:6, 15 mm thick rendering in cm 1:4 to internal surfaces and external surfaces upto 150mm depth below gl, pcc 1:3:6 type c1 as in coping, cover with two nos. of hinges and one no. handle made out of ms round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. note:- the quoted rate shall include all earthwork and connected items. 91 m & l earthing complete with galvanized steel earth plate electrode of size 600mmx600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal gl and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in electrical plate no. 3 connecting to earthing test point, including necessary earth work in any type of soil, pcc earth chamber made in pcc 1:3:6 type c1 (using 20mm graded aggregate), common salt, charcoal, ci funnel, earth pit cover in rcc 1:2:4 type b1 (using 20mm graded aggregates), with 8mm ctd bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 external electrificationm & l for ht/lt ms cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm ms strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of pcc 1:4:8 type d-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.note: ht route indicator shall be painted as under:-(i) for ht 11 kv cables - “brown”(ii) for lt cables - “blue” 93 supply and fix compact air insulated bus bar trunking system with copper busbar 1600 amps, 50 ka breaking capacity, ip54 protection, bus duct 1600 a, 415 volt, capacity sandwich type, set rybn complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to lt panel board complete all as specified and directed. 94 supply, install, testing and commissioning of distribution transformer step-down level 2 (previously ee level 3 before amendment no 4 to is 1180), 11kv0.433kv, three phase complying withis: 1180/iec-76(part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 hz system of capacity 800 kva, oil immersed naturally cooled delta connected on ht side and star connected on lt side, vector group dyn11, provided with off load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & half load (50 %) shall not be exceeded 5838 watts & 2147 wattsrespectively as per grlha rating, percentage impedance: 4.5%. losses and impedance are subjected to tolerance as specified in is 1180. the transformers should be supplied with first filling of oil confirming to is 335. the transformer should have both side cable end box with neutral brought out complete all as directed by engineer - in -charge, and installation of transformer shall be carried out as per is-10028and comprising with the following standard fittings/technical specifications:-(a) lifting lug for transformer and tank.(b) earthing terminal rating and diagram plate.(c) air release device.(d) oil filling inlet pipe with plug.(e) drain outlet pipe with brass gate valve.(f) conservator tank with oil level indicator(g) silica jel breather(j) first fill of oil upto level including conservator tank with fresh new oil conforming to is335.(k) type of connection delta/star(l) type of cooling: oil and natural air.(m) vector group: dyn 11.(n) temperature rise over an ambient of 50 °c maximum.(o) cable end box on both side for ht/lt cables of suitable size.(p) provision of thermometer with pocket.(q) provision of oil and winding temperature gauge. 95 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: the lt panel comprising of the following:- main lt panelhorizontal copper busbar for 3 phase, 440 volts, 50 hz, 4 wire system of rating 1600 amps for phases and 1600 amps for neutral. 96 incoming:-incomer:-acb 4 pole, 415 v, 50 ka with thermal magnetic release (manual draw out type) of capacity 1250 ampmetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 1600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, ics =100% icu, breaking capacity 35 ka, ics =100% icu- 02 no. (for dg amf panel & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for apfc panel & fpb 2 near bulk store) (c) mccb, thermal magnetic release, 4 pole, 415 volts, 320/315 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for fpb 1 near adm block) (d) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for existing load)(e) mccb, thermal magnetic release, 4 pole, 415 volts,125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for fpb 3 near auction disposal store)(f) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for mt complex, watch tower no 2, guard room)(g) digital ammeter with suitable ct for each outgoing 97 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (near admn bldg) 98 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral.incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for 2nd floor & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for 1st floor)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for g floor)( d) digital ammeter with suitable ct for each outgoing 99 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.2 (near bulk store) horizontal aluminium busbar for 3 phase,440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral. 100 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for equipment load & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for bulk store)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for watch tower no. 1)( d) digital ammeter with suitable ct for each outgoing 101 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.3 (near auction disposal store) 102 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 200 amps for phases and 200 amps for neutral.incoming:-(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, breaking capacity 25 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 200/5a, cl-1,15 va - 01 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, ics =100% icu breaking capacity 25 ka- 02 no. (for store dispatch complex & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for pol store, auction disposal store, covered hard standing)(c) digital ammeter with suitable ct for each outgoing 103 supply and fixing poly carbonate street light junction boxes ip 66/67 weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitablecable connecting terminals, cable lugs, including provn of one no. mcb sp 6 amps for operating the street light fittings, suitable cable glands as per site requirement, all as directed by the engineer-in-charge. 104 s & f street light bracket made out of gi tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary ms clamp-02 nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core frlsinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.note: phase should be red/yellow/blue, neutral should be black and earthing wire should be green in colour. two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 supply and fixing of led ?ood light, 200w, watt 230 v, ac outdoor type with thermal management in multiple optics and equipped with ip66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power leds and secondary lenses with ip protection incl system efficiency >110/120lpw 10kv spd included energy saving, environmental friendly and general purpose lighting complete all as specified and directed engineer-in-charge. make : make : crompton/philips/wipro 106 supply and fix high mast panel outdoor type, suitable to take load up to 6 kw, conforms to is/iec 60947-4-1, provided with protection degree ip 54, extended wide band (150 vac - 300 vac) coil, frls (fire retardant low smoke) internal wiring, in-built short-circuit protection, class h insulation, 3 phase 415 volts ac with the following accessories:phase : 3 phase, 415 voltsmax load capacity : 6 kwtimer type: astronomicalcontactor rating : 32 a tpmcb rating : 63 a tpnmake : crompton/ philips/wipro 107 supply and laying dwc (double wall corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming is 16205 (part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm st light cable & 16 sqmm cable) 108 aviation obstruction lightsupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one no.10 a, mcb, spn 230 v with fixed enclosure complete all as specified and directed by engineer-in-charge.make:- bajaj cat no bgav 302 led or equivalent in philips/crompton/surya 109 incineratorsupply, fixing and testing of solid waste electric incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°c, stainless steel stack for longevity, fitted with a velocity cowl as standard, chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree celsius mounted on foundation as recommended by oem including electrical control panel with suitable size mccb, relays & contactor recommended by oem complete all as complete all as specified and directed.note:(a) the electrical works including electrical lt panel, internal wiring of the lt panel, suitable size copper wires from panel to solid waste electric incinerator as recommended by oem to operate the solid waste electric incinerator of capacity 100 kg/hr to make solid waste electric incinerator operational is deemed to be included in the rate quoted. (b) all electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed there under and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solid waste electric incinerator of capacity 100 kg/hr all as mentioned above and which is not mentioned or included in this schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) foundation/plinth/base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the solid waste electric incinerator and height of plinth shall not be less than 0.5 m 110 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, breaking capacity 36 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 electric sirensupply and fixing sirens electronic type horizontal double mounting three phase 400/440v, 2800 rpm 50 c/s flame proof, audible range 3.5 km, 2 hp, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 supply and fix advance sirens controller electronic type suitable to operate on 3 phase, 415 volt ac 50 hzcomplete all as specified and directed. 113 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 25 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 solar power plantdesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (on-grid) on roof top of existing bldg of capacity 150 kwp, power evacuation at 415 volt 3 phase system all as per guidelines/norms issued by mnre & indian metrological deptt approved solar radiation data viz direct normal irradiance, global horizontal radiance etc complete comprising with the following solar photo voltaic plant.(a) design, supply, installation, testing and commissioning of solar pv modules capable of generating 150 kwp (ac) electricity at 415 volt 3 phase system. these solar pv modules of 540 watt perc with a modular efficiency of 17-19.84% as per iec and mnre standard or as per approved design parameters with poly/multi crystalline silicon solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to iec 61215, iec 61730, iec 61701. solar pv module should be of approved indian brand only and qualify under the domestic content requirement (dcr) norms of nvvn/seci and testing requirement fixed by mnre. the pv modules shall be warranted for a period of minimum 25 years, solar pv modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of ten years and 80% at the end of twenty five years. each solar pv module must use rf identification tag. the following information must be mentioned in the rfid used in each module:name of manufacture of pv module, name of manufacturer of solar cell, month & year of manufacturer (for solar cell and module), country of origin (lt is mandatory to use cells and modules manufactured in india). i-v curve of the module, wattage, lm, v-m, & ff for the module, unique serial no & model no of the module, date & year of iec pv qualification certificate, name of the test lab issued iec certificate. the pv modules used in the solar power projects must qualify to the latest edition of the following international electro technical commission (iec) p module qualification test or equivalent bis standards. the pv module must be tested and approved by one of the iec authorized test centres. 115 (b) material and labour for module mounting structure (mms) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 kmph wind speed all as per approved design parameters as per mnre standards and to match with the existing site conditions. necessary roof treatment to avoid any seepage in future shall be done by the contractor and the amount included in the rate quoted. the roof tiles shall be dismantled and refixed back in original position. structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) supply, laying & testing of dc cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant is, weather proof uv resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of spv modules to array junction box including suitable size of cable lugs, male & female mc4 connectors & joints etc.(d) supply, installation test and commissioning of protection devices mccb 400 a, isolator and three phase 4 wire lt energy meter, array junction boxes having rating 150 kwp with over voltage protection and surge protection.(e) supply, installation, test and commissioning of grid tie solar power conditioning unit / inverter of minimum capacity 150 kwp(dc to ac 415 v in three phase system) all as per approved design parameters & capable of generating output voltage 415 v ac at rated load condition with efficiency not less than 98 %, conforming to iec 600682-2 nde standards with power reduction, lvrt with protections for anti-islanding, ground fault monitoring, grid monitoring, ac & dc over voltage and under voltage protection, ac & dc short circuit lover current protection and dc reverse polarity protection, graphic display etc. all as specified and as directed.(f) material and labour for earthing for lightning protection for spv modules etc as per ie rule, mnre guide line & bis all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including gl strip 32x6mm size protected with gl medium grade pipe 40mm dia for earth electrode up to test point by means of gi nuts, bolts, check nuts and washers including earth work excavation, pcc (1:3:6) type cl pit and rcc cover ( 1:2:4) type bl and funnel, with necessary charcoal, salt etc complete. 116 (g) supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for spv modules lightning protection upto interconnection between roof top la to ground earthing system. (h) ac cable: supply and laying of 150 sqmm lt xlpe insulated, screened pvc bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to is 150 sqmm x 3.5core as per site requirement.note (i) :-(a) before quoting the bid, contractor or his authorised engineer/consultant must visit the proposed site to study the site condition.(b) before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to accepting officer for approval.note(ii):-(a) the mechanical structures, electrical works and overall workmanship of the grid solar power plant must be warrented for a minimum of 5 years.(b) all mechanical, electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed thereunder and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 kwp (ac) all as mentioned above and which is not mentioned or included in this schedule a but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) contractor shall provide adequate spares/items required for minimum period of 1 year maintenance including dc & ac items under scope of work.note (iii) : design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. 117 dg setsupplying, installing, testing and commissioning, factory assembled silentdiesel engine driven generator set, fully wired alternator ac to give an out put of 400 kva continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 hzsupply, 1500 rpm, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, pcc foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a)diesel engine: liquid cooled turbo charged with after cooler to deliver suitable bhp at 1500 rpm under ntp conditions of bs 5514 and conforming to is 10001/ 10002, din 6271 & iso 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class a1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) radiator with blower fan or heat exchanger with guard.(b) pipe coupling for engine cooling system piping.(c ) corrosion inhibitor coolant(d) paper element filters(i) fuel filter(ii) lube oil filter(iii) by pass(e) fly wheel housing and fly wheel to suit alternator.(f) engine bearing mechanism in fly wheel housing.(g) shut off coil with safeties for llop/hwt/over speed.(h) dry type air cleaners and vacuum indicators.(j) residential silencers.(k) stainless steel exhaust flexible bellows. 118 (l) motor driven priming pump.(m) battery charging alternator.(n) exhaust piping made out of stic c class, ms pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(o) mineral wool insulation 2 inch thick suitable for 400 degree celsius temperature cladded with aluminium sheet o30 gauge for the entire length of exhaust pipe.(p) first fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) interconnecting copper cabling of adequate capacity batteries control.(r ) fuel pipe class stic 1 /1.5 /2 dia - 01 lot(s) self starter 12 volts dc.(t) electric operated electronic governor.(u) fuel injection pump.(v) no of cylinders - 12 no vee(w) electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24v battery. (ii) water temperature.(iii) lubricating oil pressure.(iv) engine speed -1500rpm(v) engine hours(vi) frequency.(vii) voltage.(w) safety control (trip and indication).(i) high water temperature(ii) low lube oil temperature(iii) overspeed stop 119 (x) base frame: sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith avm pads.(y) battery:-24 volts(2x12v battery) dc, 180ah, maintenance free battery conforming to is:14257 with leads & terminals (make- excide/amron).(z) fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick hr/ms sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) isolator panel with 250 amp mccb(ab) auto logic panel for automatic stat(b) alternator: alternator suitable rated for 400 kva, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 hz at 1500 rpm, self excited and self regulated with avr brushless, screen protected, drip proof , insulation class-h, ip -23, voltage regulationgrade - vg 3 self ventilated and conforming to bs: 5000 / is: 4722 suitable for engine as mentioned here-in before, conformig to is: 13364(part-1)make: koel green / stampford/crompten/kirloskar/greaves(c) acoustic enclosure:- m & l for acoustic enclosure for the above 400 kva dg set to reduce noise level to 75 db measured at 1.0 meter distance for audible frequencies as per guide of central pollution control board andmanufacturers specification and comprising of following from authorised goems of gen set manufacturers specified :-(i) sound insulation : 100mm thick rock wool (density 64 kg/cum).(ii) outer body : 1.6mm thick crca(iii) door : 1.6mm thick crca(iv) base frame : ismc 300(v) inside illumination : 1 no.- 1 x 18 watt led fitting of make phillips/ bajaj/ crompton.(d) amf control panel:- factory fabricated cubicle type, free standing, floor mounted, indoor type, ip-43, amf control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick crca sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (e) amf control circuit with 4 pole mccb 630 amps - 2 nos, with ultimate breaking capacity icu-50 ka at 415 volts and microprocessor release conforming to iec 60947 part-i with breaking capacity ics=icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 nos. for main supply & dg set supply with hrc back up fuse complete with all dc control relays/ line voltage monitor (lvm) as per oem specifications incorporating motorised stored energy operating engine start, stop, three attempt starting facility and failure to start etc.(f) digital load manager : three phase 4 wire indicating v,i,pf, kva, kw, f of enercon make with serial communication port model no.em6400 with class 1.0 accuracy meter or equivalent make suitable rating of ct per phase- one no.(iii) indication lamp r, y, b with 3 nos. of 2a hrc fuses-10 sets.(iv) bottom gland plate for incoming and outgoing cables.(v) circuit diagram plate.note :- dg set should be as per cpcb -4 latest norm wef 01 july 2023 of national clean air programme (nacp) act 1981. 121 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (dg panel ) 122 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 800/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for package ac bulk store & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for pump house & fire pump)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 80 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for incianator)(d) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 07 no. (for terrace pump 1, terrace pump 2, power house, high mast 1, high mast 2, street light)(e) digital ammeter with suitable ct for each outgoing(f) astro time switch for 3 phase 20a- 1 no(g) 3 phase power contactor 20 amps, with 230 coil 123 sewage disposalm & l for laying of dwcpe sewage pipes line 200 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 m & l for laying of dwcpe sewage pipes line 150 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 compound walls & f concertina coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm gi wire for securing, coil with fish hook bars, incl necessary welding to ms sections etc all as specified and directed. 126 green building norms(griha concept)supply and install organic waste converter fully automatic having capacity 50kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-type of machine: fulley automatic in-vessel compostercomposting method: 24 hrs. micro-organisms-based compostingmachine type of microganism used: heat resistant thermophilic bacteria final output: dry organic soil conditioner/soil supplementscycle time: 24hrs volume reduction in 24hrs: 80-85% internal tank: stainless steel type main agitator shaft: stainless steel type input voltage: 415vspecial features: vfd as standard across all models, touchscreen standards daily waste processing: 150kgs rated capacity: 7kwpower consumption (kwh par cycle): 13-15length: 1650, width: 850,height: 1455 127 supply, installation, testing and commissioning three phase energy meter with the following specifications: microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (nb-iot) communication that allows it to interact with the head end system (hes) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 volts, 50 hz of range 10-100 amps, complying to is16444:2015 (reaffrimed 2020) and conforming to is 3779 with led display and parameters like voltage, current, frequency, power, power factor, kwh/kva, default in built dual source, inbuilt long range (lorawan) communication suitable for outdoor lora data accumulator and also compatible for prepaid and postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to erp complete with 5 years warranty.note:(a) the contractor would be responsible for removing the existing meter, noting down the reading and depositing it with the mes age e/m store complete all as specified & directed.(b) the energy meter to be capable of running in both prepaid and postpaid mode.(c) the meters to carry 5 year warranty. (for entire system) 128 supplying, fixing, commissioning and testing of configuration of cloud hosted multi user web based software with following modules:(i) head end system (hes): to acquire meter data automatically from dcu sand monitor parameters acquired from meters.(ii) meter data management modulethe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. the system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters cumulative energy. cumulative apparent energy (as applicable), power, current, voltage, power factor and frequency(b) monthly billing survey data for cumulative energy and max demand(iii) billing module: the billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. the billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. it would allow postpaid and prepaid functionality as required.(iv) occupation and vacation module: the system would support occupation/vacation based on the unit catagories. the system would support automatic data capture on occupation and vacation events.(v) website: there would be a dedicated website forage/ge and bso team to view all the data and information alongwith customer portal for use of customer. the designated users in mes would have the admin access to the application. the mes staff would also have the access to the key information on mobile app (androiandios based) for admin use complete all as specified and directed.(vi) customer module: the system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. there shall be consumer app (android and ios based) also to log in and view their own energy/billing data and recharge facility.(vii) communication module :the system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) meter master data: the system would support meter data repository. the system would support meter replacement process.(ix) excel export: the system would support export of metering and billing data in excel and pdf format.(x) energy accounting module: the system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) prepayment/recharging facility:the system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. the system should allow online/digital recharging through consumer app (androidand iosbased) and web portal. the configuration and necessary arrangement for payment gateway and e-mro facility shall be deemed to be included in the quoted rate. the system should sendconnect/disconnect command on the basis of available credit.low credit alarm: the system will give an alarm over the consumer app and sms to the registered mobile number in case the credit in the meter goes down be low apredefined limit.emergency credit: the meter will work even when the credit falls down to zero to prevent disconnection. this limit shall be configurable. the system should support happy hours inorder to prevent disconnection in non working hours and on holidays. the happy hours should be configurable complete all as specified and directed. 130 supply, installation, testing and commissioning of dcus/gateways and the arrangement of sim cards or internet to enable reliable medium for two-way communication between smart meter & hes. the data acquisition (push/pull) frequency shall be, configurable. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. it shall have provision for the cellular, wifi and ethernet communication for the backhaul to hes. it shall be capable to handle data of minimum 1000 nos. of any type of smart meter (1ph/3ph).it shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. communication of the nearest meters with other meters shall be established through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. the equipment shall be weather proof and dust proof (minimum rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 hosting gprs (4g) charges for gateway for five years from the date of completion f including 2 years waranty and 2 years maintinance after warranty) make:-airtel/jio/vodafone 132 supply and installation of digital water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 supply and installation of digital water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 arboriculturem & l for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 all as per item no 13.121 above but pit size 60cm x 60cm x 60cm 136 supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 supplying and planting flower plants(champa/ hybrid hibiscus/ hybrid west indian jasmine/ hybrid plumeria white plant/ panama yellow plant/ oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 supplying and planting song of india flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 supply and planting mexican grass including providing manure as directed. 144 pile foundationboring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.note:- the quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. nothing extra shall be paid on this account. 145 boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using dmc method (direct mud circulation)and getting out & disposal of spoil to any distance outside of md land , complete all as specified and as directedby the engineerin charge 146 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in cast in situ dmc bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 149 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 150 all as per item no 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 m & l for providing pcc (1:4:8) type d-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 m & l for carrying out non destructive integrity test all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 m & l for carrying out initial load test (vertical load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 155 m & l for carrying out initial (lateral load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 156 m & l for carrying out initial load test ( pull outtest) of cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 157 m & l for carrying out routine load test (vertical load)all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 158 testing of piles (initial load test) for 450mm dia cast in situ bored piles all as per is including removing the testing equipments from the site after testing is completed all asspecified and as directed
  • View Tender
  • Document
  • Bid Support
3 Security Services
image image
Central Government/Public Sector
TRN :49055023 |  12 Jun, 2025
Tender Value : 4.85 Crore
 Bengaluru Urban - Karnataka
Tender for tender for provision of deficient smqs at af stn chimney hills; 2 general summary note: schedule ‘a’ part i to xii are prepriced by mes under ser no. 1 to 12. bidders shall insert their lumpsum amount in the green coloured field under col-6 only. 3 lumpsum price worked out by the contractor for “internal water supply” as listed in schedule ‘a’part–ii 4 lumpsum price worked out by the contractor for “internal electric supply as listed in schedule ‘a’part–iii 5 lumpsum price worked out by the contractor for site clearance and development as listed in schedule ‘a’ part - iv . 6 lumpsum price worked out by the contractor for road / path / culvert as listed in schedule ‘a’ part - v . 7 lumpsum price worked out by the contractor for area drainage as listed in schedule ‘a’ part - vi . 8 lumpsum price worked out by the contractor for sewage disposal as listed in schedule ‘a’ part - vii . 9 lumpsum price worked out by the contractor for “fencing” as listed in schedule ‘a’ part – viii. 10 lumpsum price worked out by the contractor for “protective works” as listed in schedule ‘a’ part – ix. 11 lumpsum price worked out by the contractor for “external water supply” as listed in schedule ‘a’ part – x 12 lumpsum price worked out by the contractor for “external electric supply” as listed in schedule ‘a’ part – xi 13 lumpsum price worked out by the contractor for “hot water supply” as listed in schedule ‘a’ part – xii 14 schedule a part - idesign and construction of married accommodation building in 3 storey (ground+2 storey)in framed construction with permanent specifications in rcc of grade as per structural drawings, aac block masonry walls, att, pu based wpt, earthquake resistance as per latest is, green building norms with minimum 3 star griha rating etc complete all as specified and as shown on drawings. 15 design and construction of car and scooter parkingshed in rcc framed construction with permanent specifications in rcc of grade as per structural drawings, aac block masonry walls, pu based wpt, earthquake resistance as per latest is, green building norms with minimum 3 star griha rating etc complete all as specified and as shown on drawings. 16 sch a part - xiii : fittings / fixtures & misc items. internal water supply supply and fix 15mm bore kitchen sink tap, brass chromium plated dual flow pattern with silicon black flexible hose swivel type complete all as specified and as directed. 17 supply and fix 3 in 1 chromium plated wall mixer for mixing hot and cold water (for shower) screwed down for iron pipe and fixed complete all as specified and as directed. 18 internal electric supplysupply and fix modular tv socket, one module all as specified and directed by engineer in charge. 19 supply and fix modular telephone socket, rj-11, one module all as specified and directed by engineer in charge. 20 material and labour for telephone wiring with unarmoured solid annealed bare copper industrial cablein concealed of size 0.5 mm, 3 pair with pvc conduit 25 mm diaall as specified and directed by engineer in charge 21 material and labour for tv wiring with unarmoured coaxial cable, rg-11 in concealedwith pvc conduit 25 mm diaall as specified and directed by engineer in charge . 22 material and labour for mild steel box for telephone wiring including blocks, suitable for 30 pair all as specified and directed by engineer in charge. 23 material and labour for earthing complete with galvanised steel pipe electrode of size 40 mm bore, medium grade, 2.5 meter length, burried directly in ground in bore 350 mm dia vertically to a depth not less 3.2 meter below ground level with top edge of the pipe not less than 60 cm below normal ground level connected to galvanised earth lead wire 4.0mm dia by meanswith bolts, nuts check nuts and washers protected by gl light grade pipe of size 15 mm dia and connecting up with the db as the case may be upto a maximum distance of 7.5m away from the earth electrode including test point junction, excavation, earthwork, pcc chamber, rcc cover(yellow painted) with handle, watering pipe 20mm dia gi medium grade with funnel and wire mesh, charcoal dust , salt, mild steel earth markerwith earthing result, date all as per plate no.2 of ssr 1991 and as directed by engineer in charge. note:-boring charges are included in the above quoted rates 24 smart meter systemdesign, supply, installation, integration, testing and commissioning of smart meter with prepaid metering facility, ac single phase, two wire, 240 volts, 50 hz , 10 to 60 amps all as per bis 16444:2015 (reaffirmed 2020) with plug in type bi- directional communication module (the plug in module shall be field swappable /replaceable), includingnecessary communication infrastructure suitable for integration with approved communication technology gprs/rf/hybrid (gprs+rf) /any other advance technology as per cea /trai regulations etc.easily adaptable for network interface and integration with advance metering infrastructure (ami) of the project area complete in all respect all as specified and as directedby engineer-in-charge. 25 tv & telesupply and fix pvc conduit 25 mm diaconcealed in wall all as specified and directed by engineer in charge . 26 material and labour for tvwiringwith rg-6 solid copper coaxial audio and video cable for tv antenna, satellite, dvr devices, safe for using in door and out door and drawn through pvc conduit upto required length,all as specified and directed by engineer in charge. 27 material and labour for telephonewiringwith 0.4mm pvc telephone switchboardcablefor telephone , safe for using in door and out door and drawn through pvc conduit upto required length, all as specified and directed by engineer in charge. 28 supply and fix telephone distribution box ,junction box with krone module for multiple connection, all as specified and directed by engineer- in- charge. 29 external water supplymaterial and labour for drilling and tapping gi/ci water mains (in position) for branch connection of 150/100mm including all fittings such as bend, elbows, tees, reducers and unions etc all as directed by engineer in charge. 30 supply and fix brass-metal, 100 mm diaglobe gate valves, with iron wheel head, screwed both ends for iron pipe all as specified and directed by engineer in charge 31 material and labour for construction of brick masonary valve chamber of size 900mm x 900mm x 600mm internal size including necessary earth work excavation, pcc 1:4:8 type d2 for foundation, brick work in cement mortar 1:4, pcc 1:2:4 type b1 for coping, 15mm thick rendering in cement mortar 1:4 including provision of mild steel cover 3mm thick on 40 x 40 x6 mm angle iron frame work with 2 coats of synthetic enamel paint over a coat of zinc chrome primer and locking arrangements complete all as specified and as directed. 32 material and labour for construction of brick masonary valve chamber of size 600x600x600mm internal size including necessary earth work excavation, pcc 1:4:8 type d2 for foundation, brick work in cement mortar 1:4, pcc 1:2:4 type b1 for coping, 15mm thick rendering in cement mortar 1:4 including provision of mild steel cover 3mm thick on 40 x 40 x6mm angle iron frame work with 2 coats of synthetic enamel paint over a coat of zinc chrome primer and locking arrangements complete all as specified and as directed. 33 external electric supplymaterial and labour for cutting road / hard standing to depth not exceeding 60 cm and to width not exceeding 45 cm for laying hdpe pipes and making good the disturbed surfacesby 1:3:6 type c1 using 20 mm graded stone aggregate complete all as specified and as directed. 34 supply, install, testing and commissioning of cpri approved lt panel outdoor type of size 1.5x1.2x0.60 mtr suitable size recommended by manufacturercubical floor mounted type (ip-65 degree of protection ) made out of 3 mm thick ms sheet duly painted with two coats of synthetic enamel paint powder coated, bus bar 200 amps rating made of aluminium strip (40x5mm) duly drilled holes for connections and mounted on epoxy based post insulatorsfor 3 phase 4 wire 415 volts 50 hz ac supply ,hibling , cable entry boxes , cable gland incl 50x50x6 mm frame (bottom portion of the panel), grouted by using foundation 1:2:4 type c1 with 20 mm graded stone aggregates totally tested as per iec 61439-i with the following accessories. 35 incomingmccb 125 amps 25 ka adjustable type 4 pole -01 no@ as in/comingoutgoing(i) mccb 63 amps 25 ka adjustable type 4 pole -03 nos@ as out/going (working-02 , spare-01)(ii) mcb 32 ampstpnamps adjustable type as per - 03 nos@ as out /going(working-02 , spare-01)(iii)multifunctional digital type timer switch230v 50 hz, single phase40amps cap with bay pass system including power cotactor suitable 40 amp mcb 40amps toggle switch cut out of40amps. (iv) powercontactor for rex timer switch 4 pole 40 amps -01 no(v)multifunctional digital type adwancedthree phase meter volt/amp/kva/kw/ +/- 1.0% rated current, auto and manual scrooling,site selectable ct/pt ratios 80/5 etc.housing in ms sheet 1.6 mm thick duly painted with enameled paint over a coat of primer complete in all respect all as directed & specified(vi) phase indicators led type set of 3 - r,y,b -o1 setnote :- foundationfor fixing of lt/feeder pillerboard in ground floor pcc (1:4:8) type b-1 using 20mm graded stone aggregate, measured and paid separately 36 supply and fix smc loop in loop out pvc water proofjunction box of internal size 200 x 140 x 95 mmincluding mcb 6 amps,b class ,connector necessary ms clamps, nuts & bolts with washers etc required at site all as specified and as directed. 37 material and labour for pvc insulated, pvc round sheathed multicore industrial cable of size 3 core,1.5 sqmmfor voltage grade upto 1100 v, as per is 694 all as specified and directed by engineer in charge. 38 returning and filling in two parts (i) using riddled soil obtain from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. note:- excavated soil shall be riddled by using sieve to separate composite particles etc as per is 1255 1983 and refilling in trenches as in cable cushioning. 39 supply and fix gi bracket made out of light grade pipe of size 40 mm dia 1.2 mtr long bent to shape including ms clamp of suitable size nut bolt washer for fixed along the wall/pcc pole with ms clamp etc complete all as specified and as directed. 40 supply and fix mccb 3 pole, 415 v, adjustable type, 125 amps with breaking capacity 25 ka, at existing lt panel and making good connectionwith nut bolts and washers and wire connections etc. to be fixed in theexisting tr panel complete all as specified and as directed. 41 m & l for earthing complete with gi earth plate electrode 60 cm x 60 cm x 6 cm thick buried directly in ground vertically at a depth not less than 2.25 m belownormal ground level with top level of earth plate at depth not less than 1.5 m below normal ground level surrounded form all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using 25x4mm gi stripby means of bolts, nuts, check nuts and washers of galvanized iron upto test pointand protected by gi pipe light grade 40 mm bore up to 7.5 mtr connected to a main switch board or main control board and gi pipe light grade 20 mm bore for watering and including funnel, wire mesh, 80 mm thick pre-cast rcc 1:2:4, type b-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 kg/sqm in lieu of ci cover, pcc 1:3:6 type c2 pit / chamber including all necessary excavation and earth work, disposal of surplus soil to a distance not exceeding 50 m all as specified and as shown in electrical plate no3 of mes schedule part – i of 2009.
  • View Tender
  • Document
  • Bid Support
4 Agriculture
image image
Government Departments
TRN :49063260 |  13 May, 2025
Tender Value : 0
 Bilaspur - Uttar Pradesh
Tender for supply of general electric goods items for season 2025-26 , supply of general electrical goods , alluminium cable lugs all mm size longtail , amp meter c.i. 4x4 0 to 100 ( siemens) l&t / hevells / c&s make , amp meter c.i. 4x4 0 to 150 ( siemens) l&t / hevells / c&s make , amp meter c.i. 4x4 0 to 300 ( siemens) l&t / hevells / c&s make , amp meter c.i. 4x4 0 to 400 ( siemens) l&t / hevells / c&s make , ampere meter size 6x6 3000/5 , anchor make flash type switch 15 amp combind / havells / great white make , anchor make flash type switch 5 amp combind / havells / great white make , angle holder 5 amp anchor / great white make , bakalite sheet 10x12 , bakalite sheet 2x4 , bakalite sheet 8x10 , bare copper wire 4 swg for cane unloader , battery terminal in copper , batton holder 5 amp anchor / great white make , bch make coil , bch make vaccum type meter/timer 110 v (30 sec) , bectrol gray ( dr. back make) 1 ltr , bectrol red ( dr. back make) 1 ltr , bed switch 6 amp anchor / great white make , box spanner set taparia make , brass holder 100x20x20 mm kirloskar / siemens make , brasso 100ml , cable griping paste ( dowells make ) make , capacitor 10 mfd ( falcon / cosco / halcap / havells ) make , capacitor 3.5 mfd( falcon / cosco / halcap / havells ) make , capacitor 4 mfd( falcon / cosco / halcap / havells ) make , capacitor 6 mfd ( falcon / cosco / halcap / havells ) make , carben brush double tail 50x32x22 setkirloskar make , carben brush for cane unloder size set 100x20x20mm kirloskar make , carbon brush 38x22x95 jyoti make , carbon brush 50x25x16 jyoti make , carbon brush 50x40x20 jyoti make , carbon brush holder125,150,250,350 kirloskar make , carbon bush 16x32x40 mm jyoti make / kirloskar make , carbon bush 20x32x42 mm jyoti make , carbon bush 20x32x48 mmjyoti make , carbon bush 20x32x52mm jyoti make , changeover switchtype fp 32 amp, 440 volt , changeover switch 100 amp4 pole l&t / havells / siemens make , changeover switch 320 amp 4 pole l&t / havells / siemens make , changeover switch 400 amp 4 pole , changeover switch 630 amp 4 pole , capacitor2.5 mfd cosco / falcom / halcap / havells make , combination plier 8 tapana / bosch make , connection plate for motor 10 hp kel make , connection plate for motor 100 hp ngef make , connection plate for motor 15 hp kel make , connection plate for motor 150 hp ngef make , connection plate for motor 20 hp kel make , connection plate for motor 25 hp kel make , connection plate for motor 40 hp kel/bbl make , connection plate for motor 60 hp kec with utype make , connection plate for motor 70 hp ngef make , connection plate for motor 75 hp ngef make , cooler pump submersible type khaitan / crompton / easyway / digicod make , copper cable lugs all size longtail , copper conductor for cane unloader , cotton tape 1/2 , cotton tape 3/4 , crc 2-26 415 ml bharat bijke , digital energy meter 400 volt , digital multimeter 0-10000 ac/dc , digital rpm meter with sensor hand oprated , drum controller for box crane , dyno drive 40 hp eddy current controller maqke tranzil engineers , dyno drive controller for 50hp tranzil engineers make , ebonite rod 2 , ebonite rod 3 , end shield 6.3 amp fuse , english electric fuse 50 amp , english electric make hrc fuse 100 a , english electric make hrc fuse 16 a , english electric make hrc fuse 200 a , english electric make hrc fuse 32 a , english electric make hrc fuse 63 a , exhaust fan 12 bajaj / havells / usha make , exhaust fan 18bajaj / havells / usha make , exhaust fan 24bajaj / havells / usha make , fiber glass sleeve 10mm becco kianpathy , fiber glass sleeve 12mm becco kianpathy , fiber glass sleeve 16 amp becco kianpathy , fiber glass sleeve 60 amp becco kianpathy , fiber glass sleeve 8 mm becco kianpathy , film leatherised paper (black) , fix arching contact for ocb met make 200 amp , fix arching contact for ocb met make 400 amp , fix contact for ocb met make 200 amp , foot switch complete for bag stitching machine , foot switch for stitching machine , fuse tinned copper wire 32 amp bharat / goyal / electronijy , fuse wire 10 amp , fuse wire 63 amp , gi bolt 10mm x 75mm f.t , gi bolt 12mm x 100mm f.t , gi bolt 12mm x 50mm f.t , gi bolt 6mm x 25mm f.t , gi bolt 6mm x 75mm f.t , gi bolt 8mm x 200mm f.t , gi bolt 8mm x 50mm f.t , gi bolt 8mm x 75mm f.t , gi nut 10mm , gi nut 12mm , gi nut 6 mm , gi nut 8mm , gi washer 10mm , gi washer 12mm , gi washer 8mm , gi washer 6mm , glass fuse 30 a , glass fuse 5 a , glass fuse 6 a , hrc fuse ns type 63 amp , hylam sheet 6mm thick , ignitor 0-400 watt , insulating varnish ( dr. back make) , insulating varnish (other brand) , insulator for resistance box for 150 hp mei , leather isi paper good quality , led bulb 15 w phillips/syska 230 v , led bulb 20 wphillips/syska 230 v , led street light 200 w syska / bajaj 230 v , led street light 50 w syska / bajaj 230 v , led tube light 100w phillips/syska 230 v , led tube light 50w phillips/syska 230 v , led tube road 20 w phillips/syska 230 v , led tube road 50 w phillips/syska 230 v , m.c.b. 10 amp single pole , m.c.b. 16 amp single pole , m.c.b. 6 amp single pole , magger hd 500v with wire , motor cooling fan (plastic) 10 hp , motor cooling fan (plastic) 12.5 hp , motor cooling fan (plastic) 15 hp , motor cooling fan (plastic) 20 hp , motor cooling fan (plastic) 25 hp , motor cooling fan (plastic) 30 hp , motor cooling fan (plastic) 40 hp , motor cooling fan (plastic) 5 hp , motor cooling fan (plastic) 50 hp , motor cooling fan (plastic) 7.5 hp , moving coil type amp meter 0-10a for dc supply 4x4 , moving contact for ocb met make 200 amp , pendent holder 5 amp , pin type lugx 20 mmcable , pin type lugx 50 mm cable , pin-3 plug top 15 amp , pin-3 plug top 5 amp , pressure switch for negative pressure (dentos) make up to 5 kg. nov adjusting type , pt bulb 100 watt , push button element 1 no , push button station , pvc aluminum wire 2 core, 1 mmpolycab / grandley / vidhut , pvc copper u/s237/ 76 flexible wire 2 core polycab / grandley / vidhut , pvc copper w/shop40/ 76 flexible wire 2 core polycab / grandley / vidhut , pvc copper wire (national/bidut/havells make) 1.00 mm 2 core 1 , pvc copper wire (national/bidut/havells make) 1.50 mm 2 core 1 , pvc copper wire (national/bidut/havells make) 2.0 mm 2 core 1 , pvc copper wire (national/bidut/havells make) 2.50 mm 2 core 1 , pvc flexble cable 6 core copper wire 140/33 , pvc tapesteel gripb / anchor make 3/4 , sliping for 10 hp ngfe motor , sliping for 125 hp kec motor , sliping for 150 hp kec motor , sliping for 180 hp kec motor , sliping for 250 hp kec motor , sliping for 350 hp kec motor , sliping for jyoti make power turbine alternater 1.5 mw , slipring block assembly for 250 hp kirlosker motor , slipring holder 125 hp motor , slipring holder 150 hp motor , slipring holder 180 hp motor , slipring holder 250 hp motor , slipring holder 350 hp motor , slipring induction motor startor with resistanc box for slipring motor 150hp-50 hz p complete ocb , slipring induction motor startor with resistenc box 150 hpx960 rpm mei/crompton make , slipring motor starter resistance box 400amp 250 hp , socket 2 pin anchor , socket 5 pin anchor , step down transformer with enclose input 240 v out put 24 volt , sunmica sheet any size , taflon rod 2x12 , tape for techo meter reading , u type air heater 100 watt 230 volt , u type air heater 2000 watt 230 volt 990mm length , volt meter squire type 4(0-500 v) , volt meter squire type 6(0.500 v) , voltmeter0 to 500 4x4 round , voltmeter0 to 500 6x6 round , white plastic modular pvc multi-socket electric switch board
  • View Tender
  • Document
  • Bid Support
5 Power
image image
State Government
TRN :49021281 |  22 May, 2025
Tender Value : 9.49 Crore
 Jaipur - Rajasthan
Tender for tender for nib for purchase of 245kv scpi on rate contract for 2 years under bn-9016002502 nib for purchase of 5392 stack of 245kv scpi on rate contract for 2 years under bn-9016002502 , electrical items : , 245kv solid core post insulator
  • View Tender
  • Document
  • Bid Support
6 Construction
image image
State Government
TRN :49022956 |  13 May, 2025
Tender Value : 0
 Shahjahanpur - Uttar Pradesh
Tender for tender for electrical pole shifting from km 13 to garhiya rangeen (odr) of mdr-104 in distt shahjahanpur. - pcc pole 8.5 mtr long 2 st pole 11.0 mtr long 3 concreting of pole 4 acsr weasel conductor 5 11-kv disc insulator - 45kn 6 disc fitting 45 kn 7 11-kv pin insulator 8 11-kv pin with nut 9 11 kv cross arm ms angle v type 10 cross arm holding clamps 11 11 kv top channel with clamp 12 m.s. t- off channel for 11 kv 13 11kv cross bracing m.s. angle with 4 clamp 14 g.i. wire 6 swg 15 g.i. wire 8 swg 16 11 kv stay set 17 concreting of stay 18 stay wire(3.15 mm) 7/8 swg 19 stay wire(4.0 mm) 7/10 swg 20 earthing of pole 21 m.s. earthing rod of 20*2540 mm 22 earth wire clamp 23 danger board with clamp,nut and bolt 24 bolt,nut and washer all sizes 25 guarding angle 26 guarding angle clamp for st pole 27 clamp with bolts and nuts. 28 dead end clamp 29 stone pad 300*300*75 mm 30 labour & cartage charges @20%
  • View Tender
  • Document
  • Bid Support
7 Sugar
image image
Co-operative
TRN :49023911 |  20 May, 2025
Tender Value : 0
 Powayan - Uttar Pradesh
Tender for supply of general electrical items for season 2025-26 , description , remote bell , tong tester meco make 1000 amp a.c./d.c. , manual control fan regulater 4 steps, single module , mcb din rail channel, 35mm width , air heater heating element 1 meter single , amp.meter 4x4 ,0 - 600 amp ctr 600/5 , amp.meter 4x4 ,0 - 800 amp ctr 800/5 , amp.meter 4x4 ,0 - 1000 amp ctr 1000/5 , amp.meter 96x96mm , ctr 100/5 , amp.meter 4x4 ,0 - 50 amp ctr 50/5 , amp.meter 4x4 ,direct 0-10 amp & 0-20 amp , amp.meter 96x96mm, 150/5 , amp.meter 4x4 , 300/5 , amp.meter 4x4 , 400/5 , ct 50/5,60/5,100/5,150/5,300/5,400/5,600/5,500/5 , ct ae make 1000/5 , piller assambly for 800 amp , ct630/800 amp for acb , operating handle on/off 800 amp , dn 1 release , cable tie 4 , cable tie 6 , soldring paste , change over switch 400 amp in ss hpl /sucomake , indicator led 220 volt red , volt.meter 4 0 - 500 volt , contactor 6 way 30 amp. l&t/schneider/switch gean , amp. meter 0 - 15 amp 4 , amp. meter 0 -160 amp 4150/5 a/e / rc , power contactor 3ta22 230 volt , mcb single pole 32 ampschneider /l&t / abb , mcb double pole 16 amp schneider /l&t / abb , mcb double pole 20 amp schneider /l&t / abb , mcb dboule pole 32 amp schneider /l&t / abb , mcb triple pole 16 amp schneider /l&t / abb , mcb triple pole 20 amp schneider /havells , mcb triple pole 32 amp schneider /havells , mcb triple pole 63 amp schneider /havells , distribution board 12 way spn (mcb box) schneider /havells , digital energy meter 3 phase 4 wirectr 200/5 l&t , transfarmer 1 kva 230 volt , sambersibleflexible flat copper cable (35mm x3 core) , change over switch 800 amp 4 pole hewlls make l&t , change over switch 400 amp 4 pole hewlls make l&t , pvc copper cable660/1100 volt for unloder 1.5mm 16 core , carbon bush 50x32x32 usha/bosch , volt meter 4 0-100 volt a/e , oil resistance box 250 hp rb450 ra 146 oil immersed , dinodrive electronic controllereddy current control , pvc copper flat sambersible cable 6mm 3 core , electronic blower wolf make /eastman , spray gun h.duty , digital rpm meter 0-500 rpm wantran , fuse base nsh 20 amp , indicating lamp 240 volt complete hack/jigo , push button element 1 no , push button element 1 nc , mcb box 4 pole l&t , indicating lampr y b , piston drill machine complete wolf make bosh , hand lamp , push button element 1 no+1nc teknic , ct 30/5 , pvc coolling fan 5 hp 1440 rpm ke make simenss , pvc coolling fan 7.5 hp 1440 rpm ke make simenss , pvc coolling fan 10 hp 1440 rpm ke make simenss , motor fan cover ke make 5 hp 1440 rpm ke/ simenss , motor fan cover ke make7. 5 hp 1440 rpmke/simenss , motor fan cover ke make 10 hp 1440 rpm ke/simenss , allu. imhibiting crosen cable compound ke/simenss , hydraulic cable crimpingmachine upto 400 mm complte taparia , hydrauliccable crimping machine upto 95 mm compltetaparia , p t bulb 24 volt , slipring 90 hp 67 kwframe size lcw 250 , slipring250 hpframe size rw 10539 , slipring250 hp1480 rpm , carbon brush holder90hp lcw 250 , carbon brush holder150 kw rw 10539 , carbon brush holder370kw , spare for oil immersed star delta starter , a- moving arching contact with guttka , b- fix finger contact big , c- fix finger contact small , amp meter 72x72mm 30/5 , amp meter 72x72mm 100/5 , cannector element 35mm , connector element 50mm jigo/rc , connectorelement 70mm , electronic timer 415 volt 36-120 secd. simenss /l&t , g.i.g.o.l. varnised crodium nut & bolt with washers , ………………………………do…………………………….12x50mm , ………………………………do…………………………….10x50mm , ………………………………do…………………………….8x50mm , ………………………………do…………………………….6x50mm , ………………………………do…………………………….12x65mm , ………………………………do…………………………….10x65mm , ………………………………do…………………………….8x65mm , ………………………………do…………………………….6x65mm , ………………………………do…………………………….12x75mm , ………………………………do…………………………….10x75mm , ………………………………do…………………………….8x75mm , ………………………………do…………………………….6x75mm , drill machineh.duty bosch , v.s.f. treding tape 1/4 , v.s.f. treding tape 1/16 , v.s.f. treding tape 3/8 , v.s.f. treding tape 1/2 , v.s.f. treding tape 5/8 , v.s.f. treding tape 3/4 , control transfarmer input 415 volt a.c. output 230 volt d,.c. 0.5 kva wnton,gromption , geyser 25 ltr gromption/havells , change over switch 250 amp ss havells/l&t , cooling fan 75 hp bharat bijli/simenss , cooling fan 60 hp bharat bijli/simenss , cooling fan 40 hp bharat bijli/simenss , cooling fan 15 hp bharat bijli/simenss , cooling fan cover 75 hp ke make simenss/bharat bijli/kirloskar , cooling fan cover 60 hp ke make simenss/bharat bijli/kirloskar , cooling fan cover 10hp ke make simenss/bharat bijli/kirloskar , terminal plate 75 hp ke makesimenss/bharat bijli/kirloskar , terminal plate 7.5 hp ke make simenss/bharat bijli/kirloskar , terminal box 15 hp 160 kh simenss/bharat bijli/kirloskar , terminal box 7.5 hp kh 132simenss/bharat bijli/kirloskar , carbon brush 16x32x38 jyoti/bosch , carbon bush 10x22x38 , carbon brush 20x40x50 , carbon holder jyoti make jyoti , copper rod 1.5x18,long , g.i.g.o.l. varnised crodium nut & bolt with washer---- , …………………………..do………………………….16x50 , …………………………..do………………………….16x75 , …………………………..do………………………….18x50 , …………………………..do………………………….18x75 , …………………………..do………………………….15x50 , …………………………..do………………………….15x75 , …………………………..do………………………….15x26 , …………………………..do………………………….12x25 , …………………………..do………………………….10x100 , …………………………..do………………………….12x100 , …………………………..do………………………….10x20 , …………………………..do………………………….10x25 , …………………………..do………………………….8x25 , …………………………..do………………………….6x25 , mcb box3 pole havells /anchor , hrc fuse tia 32 amp simens/l&t , hrc fuse tis 63 amp simens/l&t , terminal plate 60 hp ke/simens/bhart bijli , cooling fan 3 hp , slipring resistance box 3 step 7.5 hp r v 140-170 volt , slipring resistance box 3 step 10 hp r v 206 volt , highvoltage syenthetic insulation electric make suitable for , upto 33 kv isi 15652 thk 12mm length 1x2 mtr , spare for 300 amp ocb------ , a- moving arching contactl typetulip/ , b- v bar , c- fix arching contact , d-fix moving contact , amp.96x96mm direct 0-15,amp , ct 90/5ae/l&t , infrared thermo meter max.output1mm 670 mm lenth ledger type , ct 120/5 ae/l&t , ct 180/5 ae/l&t , indicating light lead red 220voltjigo/ae , terminal plate 10 hp , overload reley 25-40 amp simens , stater for 150 hp /110 kw sliparing motor with housing , slipring resistence box 3 step 150 hp r v 330 volt oil immersed , archute 800 ampl&t , amp.meter 120/5 ae/rc/jigo , amp.meter 180/5 ae/rc/jigo , d.spanner set taparia , ring spanner set , box spanner set , contimoty tester with cell , indicating bulb 7 watt 20 volt , change over switch onload 630 amp in ss 4 pole hewlls/semens , auxillary contanct block 3ta24/3ta28 , hexa blead fram h.duty with blaed bosch , nut & bolt with double washer 1/8x1(1 sut) , nut & bolt with double washer 1/8x2(1 sut) , nut & bolt with double washer 1/12x1(1.5 sut) , nut & bolt with double washer 1/12x1-1/2(1.5 sut) , h.duty batterycharger with incloser , musroom push bottan red , h.duty fut switch teknic/jigo , fut switch element l&t/switch , water resistance box for 300 hp , oneway switchhavells/anchor , electronic regulater dinospeed ed currenthavells/anchor , digital magger meco make modle-dit 99 c , clamp meter modle-3690 rishi/mecho , fibre glass tape1” , empire tape 3/4 , c.r.c.2.26 spray bottle, 400 gram ml , fibreglass tape 3/4 , ferrule 25mm2,0-9/0-mm2 , copper strip 2” widthx1/4 , cable gland 3x240mm , g.i. wire 4 swg , cable gland 3x195 mm/185 , bus bar insulator size ½”x8” suman/lby/wingwan , allu bus bor strip 10x5mm2 , hrc fuse n.s. type 16 amp. , glass sleeve size 1mm , glass sleeve but size 2mm , glass sleeve butsize 3mm2 , glass sleeve butsize 4mm2 , glass sleeve butsize 5mm2 , glass sleeve butsize 6mm2 , glass sleeve butsize 7mm2 , glass sleeve butsize 8mm2 , glass sleeve butsize 9mm2 , glass sleeve butsize 10mm2 , h.t.tape size ¾” , h.t.tape but size 1 , battery terminal 12 vote , phase testertaparia make , wooden board 8”x10” , porceline pipe ¾ “x12” , angle holder anchor makehavells , ceiling rose anchor make havells , saddle size ¾ “ , wooden board with sunmica top 9”x12” , power condenser 2.5mfd havells/gc , do but 4 mfd , -----d0------but 4mfd , -----d0------- but 6 mfd , ----- d0------ but 8 mfd , ----- d0------ but 33 mfd , -----d0------- but 100 mfd , c.t.c. , pendent holder k-555 , tube holder bajaj/anchor/havells , condenser 15 mfd,440v/anchor/havells , cotton tape 1” , araldite 180 grms tube , porcelisne s.t. holder 250 , ----- do------ prut 70 watt. , hand lamp complete with lamp , heater &element 150 watt. surya , cotton tape ¾ , s.t. holder 100 watt k-555 , petroleum jolly , exhaust fan,1440 rpm 18 ke / havells , condenser 12 mfd/ lo mfd 250 volt usha make , ----- do--- but 20 mfd , ----- do--- but 30 mfd , soldering wire 18 swg, , white patrol , film paper 10 mile , screw driver set taparia/jhalani , screw driver no.839 taparia/jhalani , screw driver no.832 taparia/jhalani , screw driver no.829 taparia/jhalani , g.i. strip 1/8”x2” ici markedtaparia/jhalani , screw driver no.829 taparia/jhalani make , screw driver no.929 , nose plair size 8” , soldering iron 250 watt. havells/gompton , insulating plair size 8”taparia make , soldering iron 35 watt. wala/mcare , cable 4 loud50 mm2 , ------ d0---- but 120 mm2 , ----- d0------but 185 mm 2 , black tape ¾ , flash type switeh & socket combimed 15 amp.anchor make , s.c.holder 60/100 watt jyoti make , button holder anchor make havells , flash type switch 5 amp anchor mak , flash type switch 5 amp anchor make , metallie carbon bush with tail,grade e-15 size 3/8”x7/8”x1.5” , do but 16x31x40,mm , ----d0—but 12x171x30 mm , ----d0—but 15x20x65 mm , air dry insulatingvarnish dr back make , bactrol gray vanish dr back make , thinner for varnish , tumbler switch porclinebase 15amp.kay make , ---d0----- but 5 amp. , plug top 5 amp. anchor make havells rk , ---d0----- but 15 amp. , metallic carbon bush without tail grade-15 sige ¾”x1”x3” , carbon bus holder brass base for cane unloader dewalt , nicrome wire 20 swg , nicrome wire 23 swg , dioide forward polarity 321,150,ratan shah make jyoti , ---d0---but 321 um100g , flexible pvc capper twin twisted 23/26 2 core vidyut / hemtron national make coil & 91.44 mtr , ---- d0--- but 40/76 , pvccopper wire/lore3/22 nationalmake havells , pvccopper wire/lore3/20 nationalmake havells , pvc copper wire lore3/22 national/vidyut/havells , ---- d0--- but 3/20 , ---- d0--- but 7/20 , ---- d0--- but 7/22 , pvc copper wire,1core7/18 national/vidyut/hemtrox make(coil of 91.44mtrs) , ----do----but 7/20 , workshop flexible wire2 core,40/76,national/vidyut/hemtrox make(coil of 91.44 mtrs) , -----do----but 23/76 , push button switch with element 3-11] 1not 1nc , limit switch type lt/lrgr.no.7-13 ac-11415v 1.5 amp d.c.-11,vaishvion make , multi meter sanwa make small size micho/rishi , limit switch type c.s. 100v, 1nc, 10a,500a ]ac.vaishnomake , proximityswitch as per sample stronger , electronic timer et-100 semens /l&t , ag timer 0-110 sec. terminal l 1+2controlsupply 3+4 instant hours 5+6 delay ete ,double relay , ----- do---- but 0-50 sec. , fuse base & carrir cutout backalite 50a , ----- d0--- but 63 amp , ----- do--- but 15/16 amp , glass fuse 5 amp , indicating lamp pin/serew type 50 voltjigo/ae , holder for indicating lamplamp 3 watt. jigo/ae , mataliecarbon bush with out tail ¾”x1”x3” , ---- d0--- but 8x20x35mm , --- d0—but 16x32x40mm , do---- but.19 x 40 x 50 mm , --- d0--- but 22x32x45mm , pvc flexible copper wire 1-5 mm2yudyt make havells , pvc copper wire 6lare 120/76 double visulated national/anchor , solenoid coil 230 v a/c for s.d. machinerotox/rutork , multi core copper cable 12x115sq mm national/vidyut/hewtron make , power capacitor universal/lot/siemeus make , slipring carbon holder brass frame lcw -250kw-67, rpm-1630, v-rotor v-2287 for spray pond , fixed & moving kit mei make starter type n-2 suitablefor 200 hp motor rating 300/%a 415 v , fix & moving kit for sliring motor startertype osr-10-8 hp-120, v-415] mb1 make , fusebase with cap & gagu ring 63 amp tp. for d.z. type fuse b.l. make , d.z . type fuse 63 amp. , d.ztype ring 63 amp , ------ d0---- but 25 amp , dztype fuse link 63 amp l&t, semens , copper wire swg havells/anchor/polycab , copper wireswg , fuse cop 25/35 amp , fuse cop 63 amp , hrc fuse link d2 type 25amp , -------- d0---but 62 amp , kit kat porciline unit 16 amp , ---- d0---32 amp , d.p. main switch 16 amp 415. standerd makehavells/l&t , ------ d0—but 32 amp , fixed & moving contact rs-15 kilburn make , ----- d0--- but 5d -15 , carbon bush 1.5”1/3/8”) , dztype fuse base tripple pole 415v,63 amp , ------ d0----- 35/25 amp , dz type guagering 35 amp , d2 type fuse 25/35 amp , corbon buse holder for500 hp motor , do for 210hp motor , motor terminal connection plate 40 hp (kec) make , ------- do--- but 60 hp , ---- do---- but 15/25 hp , ---- do---- but 15 hp , moving iron amp meter flash type dia ct operated 600/5 amp aemake , c.t. 600/5 amp af2 make l&t , amp meter pedastal type 0-30 amp to 60 amp , amp meter 300/5 amp size 144x144ae make , volt meter 0-600 amp , amp meter 200/5 amp 96:96 ae make erh/rc , volt meter o-150 size 144x144 ae make , amp meter square mounted 75x75 mm2400 /5 amp ct operated ae make , hylimerod ½ “/ ¾” , mcb 6 amp. mps/ ind.copp 10 amp , k.w. meter range 0-300 ct-400/5 amp 3 pole 415 volt size 144x144 , stay wire , stay insulator ¾”x4” , terminal connector 2-5 mm elemex make , a.c.s.r. conductor , digital multimeter frequency meter make- ae/abb/ l & t. , carbonbushsize100x20x20 mm , ------- d0 ------ but 20x20x20 mm , digital multimeter electronic , model 9a, dmm-18,meea meter pvt ltd. , baokelite fuse (cut-out)63 amp .standard make , ------- do---- but 16 amp , fuse for a.v.r. , slipring 150 kw/100 hpmake ke/l&t , bengin , meggarr 1100 volt motwani i make , hylumsheet ½” , switchgear items itemmake meeho , super enamalled copper wire devidayal/htp/bic , cables lugs dowell’s make , condenser80mfd asian/usha make , fiber glass sheet all size , cotton tape size ½”steel grip , d.c.c. allu wire all size , change over switch 63 amp standard makel & t , -------d0--- but 100 amp , hrc fuse type gsa 50 amp , spare kit sd-15 kilburn make , serew driver 12” taparia male , ------ do---- but 10” , film paper 14 miles lrs/ uokho , soldering iron 65 wattom/rc , soldering wire 21 swg , fixed & moving contract kit r-5,50 hp, 460 v , magnetic coil for spare kit make gikfun / hoby magnet , s.t. holder 300/500 watt jyoti make , pvc copper unarmoured flexible cable 1.5mm*15crore,500v national make 151mark , twin twist copper wire 14/76 2crore 151mark each coil of 91.44mtrs , pvc allu wire 2.5mm 2crore 151mark (coil of 91.44mtrs , lamps &tubescrompton/bajaj make/ ancher , fittings& accessoriies crompton /bajaj make/ ancher , hn type fuse base 630 amp e.e. make om/rc , ------ d0---- but 400 amp , t.p. fuse base d~ type 500 v. 63 amp, bch make , --------- d0------------ but 25 amp , fuse cap for above 63 amp bch. make , ---------- do--- but 25 amp , guage ringfor above 63amp , tpn switch 32 amp havells make/crompton , ------- do------ but 63 amp , power contactor 20 amp 415 v.bch. make , -------- d0------ but 25 amp , --------- d0 ----- but 40amp , no volt coil 20 amp bch. make , ------- d0----- 40 amp , o.l. relay 8 to 13.5 amp bchmake , ------- d0 ---- but 13.5 to 20 amp , slipring assembly asi make for 170 hp motor , heater element 2000 watt best quality , motor cannectionlead , fuse wire 20/25 amp , compensatingcablek type , leatheriesed paper , porcilinkitkat 100 amp , diode w-400,d-170 forwand for weling machine , p.t.bulb 100 watt crompton/ phillips , urica wire 10 sws , amp motor 144x144,0-5 amp dc-75 mv. , amp motor 21/2,0-5 amp dc. , volt meter 21/2x21/2 0-150 vdc , suppressor superstar for 1500 kw alternator , combination plier-8 make taparia , screw driver-8 , crc-226 ml-300/ 400 , multi meter meco , slipring id-73 od-205lenth-142 , proximitly switch 30 vdc , p.t. holderanchor , st holder 100 wattanchor , pvc tape 3/4steelgrip , condensor 2.5 mfd havells , condensor 3.15 mfd havells , condensor 4 mfd havells , condensor 6 mfd havells , proximitly switchdia 18 mm 200 ma/ stronger , smps 240 volt input-24 volt d.c.2.5 amp. omron , push bottan station10 way make ae , condensor 10 mfd havells , glass tape steelgrip , volt meter 4 500 volt , amp meter 4 150/8 amp0 ctr , c.t. 60/5 amp ae/l&t , c.t. 30/5 amp , c.t. 800/5 amp , amp meter 4 60/5 amp ae/rc make , diod 321 farward ruttonsha/ axeit make , diod 321 reverse ruttonsha/ axeit make , clamp meter a/c d/c 1000 amp. , potentio meter 10 k make rc , amp.meter dc-6 0-10 amp. , glass fuse-30 mm 10 mm with fuse , remote push botton set complet. make kamcon , heavy dutty magger 500 watt yokins/ risabh , teflon tape champion , soldring iron 25 watt , amp meter ctr 600/5 amp dia-3.5 ae/rc , carbon brush copper- 21.5 x 32 x 52 , continiuty tester with celltaparia , phase tester taparia , mcb 10 amp. dpanchor/ abb , mcb 10 amp. sp anchor/ abb , mcb 32 amp. tp anchor/ abb , mcb 63 amp. tp anchor/ abb , mcb 6 amp. sp anchor/ abb , mcb 6 amp. dp anchor/ abb , hydaulic thruster for cane unloder , pvc copper sumbersible flate cable-35 mm x 3 core , copper flexible wire-23/76 havells/ rr cable , w/s flexible copper wire-23/76 x 2 core havells/ rr cable , copper wire 2.5 mm x 1 core havells/ rr cable , copper wire 4 mm x 1 core havells/ rr cable , copper lug- 16 mm h.d dowells , copper lug- 25 mm h.d dowells , copper lug- 35 mm h.d dowells , copper lug- 50 mm h.d dowells , alu. lugs- 25 mm h.d dowells , alu. lugs- 35 mm h.d dowells , alu. lugs- 50 mm h.d dowells , alu. lugs- 70 mm h.d dowells , alu. lugs- 95 mm h.d dowells , alu. lugs- 150 mm h.d dowells , alu. lugs- 240 mm h.d dowells , sv choke 250 wattbajaj/ philips , sv choke 400 wattbajaj/ philips , pvc copper wire 1 mm x 2 core rrcable/ havells , led light- 14 watt bajaj/ philips/ cropton , pt. bulb 100 watt bajaj/ philips/ cropton , st bulb-100 wattphilips/ cropton , pvc copper wire 1.5 mm x 2 core havells/ rrcable , pvc copper wire 2.5 mm x 2 core havells/ rrcable , pvc copper wire 4 mm x 3 core havells/ rrcable , pvc copper subnersibile flate cable-35 mm x 3 core , copper flexible wire-23/76 , w/s flexible copper wire-23/76 x 2 core , pvc copper wire 2.5 mm x 2 core , ignitor for s.v. lamp bajaj / surya , s.v. lamp 250 watt bajaj , s.v. lamp 400 watt bajaj
  • View Tender
  • Document
  • Bid Support
8 Industrial Development Agencies
image image
corporations/Associations/Others
TRN :49026548 |  27 May, 2025
Tender Value : 15.15 Lacs
 Baghpat - Uttar Pradesh
Tender for tender for providing led street light network in dark zone at iidc baghpat. - supply & fixing 90 w led street light having die cast aluminium body and diffuser with driver set suitable for 90 watt confirming to ip 66 protection complete in all respect with surge protection device. minimum cat aa (crompton/philips with 5 year warrenty against defects,damaged & missing)make: cormpton/philips/bajaj/wipro. 2 supply & fixing steel tubular pole 9.50 metre long designated 410 sp-39 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect. 3 s/f of street light junction box made of smc material complete with 4 way terminal block, cable gland etc. 4 s/f of 6 amp to 32 amp sp mcb (10ka) b curve 5 supply & fixing 32mm dia,1.20m long gi bend pipe with 02 nos. clamp of 50x6mm ms flat suitable for fixing street light on st pole including cost of men and t&p. 6 supply & fixing upsida logo plate(retro-reflective) on st pole including cost of clamp and nut & bolt as per design of e/i. 7 supply & fixing pole earthling of pole by inserting ms rod 20x2500mm in vertically ground level and connecting the pole with the help of 6 swg gi wire including cost of all material, men and t&p. in industrial area as per upsida/uppcl technical specification. 8 s/e of d clamps of 38mm x 6mm flat iron for wall/ roof type service bracket with bolts, nuts etc, complete in all respects including painting with aluminium paint 9 supply & fixing of 100 x 110 mm shackle insulator /100 x 80 mm pin insulator including g.i. bolts/ spindle nuts etc.complete in all respect.as pre uppwd sch. no. 621 10 supply, sagging & tensioning of 6 swg gi earth wire including cost of material, men and t&p 11 suppy,laying & drawing of3x1.5 sq mm pvc insulated copper cable for street/flood lights connection in existing pipe/surface/air as required including cost of material, men and t&p. (havells/polycab/grandlay) 12 supplying and laying of 25 sq.mm 3.5 core aluminium conductor pvc insulated, armoured, served, sheathed cable 1100 v grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand alround and protected with burnt bricks on sides and on top complete in all respects. uppwd sch 510(j)-507 13 supply and laying of 16 sq mm 2 core aluminium conductor pvc insulated , armoured , served ,sheathed cable 1100 v grade in existing pipe/surface/pole etc.( havells/polycab/grandley) schedule 501©-507 14 supply & fixing of 25 sq. mm 3.5 core cable socket/lug with insulated tape in cable termination complete in all respect. 15 supply & fixing of 16 sq. mm 2 core cable socket/lug with insulated tape in cable termination complete in all respect. 16 supply & fixing of 25 sq. mm 3.5 core brass nickle plated compression gland for pvc insulated cable complete in all respect. 17 supply & fixing of 16 sq. mm 2 core brass nickle plated compression gland for pvc insulated cable complete in all respect. 18 providing & fixing 35mm x6mm g.i. earth strip on surface or in recess including cost of gi saddle/al. alloy/cadmium/pvc fastener etc.plated iron screw etc. as required for connections. 19 supply and fixing of ms/gi clamp as per design suitable for fixing shackle insulator, made out for 50x6mm m.s. flat including nut, bolt & washer.(for tun and t-points ) 20 supply , sagging & tensoning of overhead line with insulated acsr weasel conductor including binding etc complete in all respects. 21 supply,sagging,tensioning,jointing and binding of acsr weasel conductor including cost of aluminium tape binding wire and jointing sleeves complete in all respects including materiai,men an t&p for proper completion of work . 22 cleaning & spray painting of st bend pole and power st pole ( upto 7 mtr height in case of shut down) with one coat of red oxide primerand two coat of aliminium paint/pu paint as per direction of engineer incharge including cost of all material, men and hydraulic cran,other t&p ( burger/nerolac/asian mark) 23 painting letter ( pole no. ) 2.5 cmm up to 8.0 cm size complete on street light pole/panel/other electrical properties under upsida including cost of all material , men and t&p. uppwd civilsor sch item mno.817, ch-26 24 supply & fixing of 16 mtr high mast shaft of approved make with rising system hot dip glavanized inside & out sidedip,heavingpolesheetthickness3mm.topdia minium 150 mm, bottom dia 360 mmbase plate 32 mm thicksuitable forwindvelocity asperis 875part 3& havingnocircumferentialweld,withaccessoriesfor highmastsuchasheadframesuitablefor6to12 luminaries&its controlgearboxes 1.5hppowertool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch,including making suitable foundationaspermanufaturedrawing/sitereuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect. (bajaj/philips/wipro/crompton/bp & approved make in uppwd) all respect (bajaj/philips/wipro/bp & approved make in ppwd) with upsida acrylic glow shine prescribed logo 25 supply & fixing of factory wired integral 200 w led flood light luminaries with die cast aluminium housing built with driver set confirming to ip 66 protection complete in all respect, cat.-aa (bajaj/philips/wipro/crompton/approved make in uppwd) with labour. 26 supply and fixing 25a tpn capacity of automatic street light cubicle control panel painted with anticorrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors, hrc fuses, isolating switch metering insteument & instrument box with cts etc. complete in all respect. (with labour) 27 supply and wiring of submain with 2 number 2.5 sqmm frlsh pvc insulated single core multistranded copper conductor cable in existing conduit complete in all respects complete. 28 supplying and laying of 16 sq.mm 4 core aluminium conductor pvc insulated, armoured, served, sheathed cable 1100 v on serface the cable run shall be fixed on ms clamps etc of suitable size or as directed by the e.i. grade at a complete in all respects cable laying in existing pipe. (havells/polycab/grandley) 29 supply & laying of 63 mm hdpe pipe isi marked along with all accessories like socket, bend, couple etc. confirming to is 14930 part il complete with fitting and cutting jointing etc direct in grownd 75 cm below ground level including excavition and refilling the trench but excluding sand cushining and protective covering etc. 30 supply & fixing of 16 sq. mm 4 core brass nickle plated compression gland for pvc insulated cable complete in all respect. 31 supply & fixing of 16 sq. mm size pin or plan type copper tin plated socket/lug to cable leads with insulated tape and making connection to point complete in all respect. 32 supply & fixing of 50 mm dia gi pipe b class for climbing up the cable from ground to over head line lt pole complete with gl fitting including material, labour and t&p as per upsidc sch item no. 25a. 1(ls 6.0 mtr for each hm) 33 supply and laying of 32mm x6mm g.i. earth strip from earth electroded directly in the ground level as required on surface or in recess including cost of gl saddle/al. alloy/cadmium/pvc fastener etc.plated iron screw etc. as required for connections. (5m for each) 34 s/b of 40 mm dia x 4.5 mtr. long g.i. pipe vertically for earthing having 12 mm dia. holes spaced 75 mm apart drilled upto 2 mtr, from the bottom complete with earthing lead of no.6 to 8 swg gi wire in g.i.pipe upto appron upto switch board 30 cm square box with hinged cover masonary enclosure. funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction e/i complete in all respect as per drawing uppwd sch. no. 701 35 supply & erection of stay set at 3.5 metres away from the pole complete with galvanised 19 mm dia x1.80 metre long stay rod, 30 cm x 30 x 6.3 mm anchor plate, thimble stay clamps, stay insulator, 19 mm 600 mm double screw tightener, 7/3.5 mm g.i. stay wire etc. in 1:3:6 cement concrete complete in all respect. 36 supply & fixing of led light strip with driver on street light pole at central verge road no. 1 &2 including cost work t&p men and material complete in all respect. the led strip should be in tri colour as red, white and green (each colour 6 mtr.respectively.) with 01 year warranty against defects/damage/missing. 37 supply and wiring of sub main with 02 nos.of 2.5 sq.mm frlsh pvc insulated 1100 v grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and t&p required for proper completion of work as directed e/i 38 fabrication, supply and fixing of work information board in m.s. frame made by 50mm dia square pipe of stainless steel grade ss-304 & 16 mm thick base plate with back supporting of bracing by ms flat of 25x6mm and 2.85 mtr long supporting leg made from 65mm pipe ss-304 grade with proper grouting arrangement. the board should be retro reflective type in green color with white letters as required and shall be fixed at a height of 1.2 meter from ground by providing 0.45x0.45x0.60 mtr cement concrete stone pad as per drawing enclosed.the borad should be installed within 07 day of signing of contract boand.)
  • View Tender
  • Document
  • Bid Support
9 Security Services
image image
Central Government/Public Sector
TRN :48280497 |  17 May, 2025
Tender Value : 4.14 Crore
 Leh - Ladakh
Tender for tender for provision of central mi room at nimu(job no 01/nimu stn/amwp/2023-24); 1 lump sum price worked out by the contractor for building worksas listed in schedule ‘a’ part-i representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 43 2 lump sum price worked out by the contractor for (site clearance, excavation & earth work)as listed in schedule ‘a’ part-ii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 44 3 lump sum price worked out by the contractor for (internal electrification)as listed in schedule ‘a’ part-iii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 50 4 lump sum price worked out by the contractor for (internal water supply)as listed in schedule ‘a’ part-iv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 52 5 lump sum price worked out by the contractor for (road, path & hardstanding)as listed in schedule ‘a’ part-v representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 54 6 lump sum price worked out by the contractor for (sewage disposal)as listed in schedule ‘a’ part-vi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 55 7 lump sum price worked out by the contractor for (area drainage)as listed in schedule ‘a’ part-vii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 56 8 lump sum price worked out by the contractor for (shed for dg set)as listed in schedule ‘a’ part-viii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 58 9 lump sum price worked out by the contractor for (hot water supply)as listed in schedule ‘a’ part-ix representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 59 10 lump sum price worked out by the contractor for (external electrification)as listed in schedule ‘a’ part-x representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 65 11 lump sum price worked out by the contractor for (external water suplay)as listed in schedule ‘a’ part-xi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 66 12 sch a part - xii (misc b/r & e/m items) (refer boq)note: this schedule is not pre-priced by mes and the rate indicated as rs 0.00 under col 5 signifies this fact only 13 internal electrifications&f double door three phase prewired distribution board vertical db vtpn 8 way with acrylic door made out of crca sheets 1.6 mm thick,phosphatised powder coated with copper bus bar 200 amps, 415 v,ip 43/ik09, earth stud, din rail, polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingmccb4 pole 63 amp rating repturing capacity 16 ka.(note:- single phase mcbs are to be measured and paid for seperately) 14 s&f led building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240v, ip 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long med grade gi pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith ms clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm pvc insulated 3 core wire complete all as directed and specified by engr-in-charge.note - cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 s&f new wall mounted fan of approved make and type complete all as specified and as directed. 16 s&f tv co-axial socket 1 module, complete all as specified and as directed. 17 s&f single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole mcb 20 amps 18 internal water supplys&f single piece vitreous china wash down water closet pan pedestal pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type b-0, as in repairs complete all as spd & directed complete all as specified and directed by engr-in charge.. 19 s&f cp grating including jointing to waste pipe fixed in cement concrete type b-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by engr-in charge. 20 s&f hand shower (health faucet ) with 8mm dia and 1 meter long cp flexible tube and wall hookcomplete all as specified make: cera, jaquar , marc & hindware as per sample and directed by engr -in charge 21 s&f soap dish (s/s), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by engr-in charge. 22 road, path & hard standingm&l for wet mix macadam (wmm) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of morth (ministry of road transport & highways) specification of road and bridge works 2013. manufactured in wmm plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 kn static weight and conslidating required gradient and camber. the finished surface tolerance to be as per table 900-1 of morth specification for road and bridge works 2013 complete all as specified and directed by engr-in-charge. 23 m&l for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to bs 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 m&l for rcc septic tank designed to carry sewage and sullage water, excavation in any type of soil, pcc 1:4:8 below foundation, rcc m-30 design mix in walls , base slab , baffle walls and roof slab including beams etc with vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 m&l for soakage wells excavation, in any type of soil, foundation in pcc 1:3:6, walls of honey combed masonry with top ring of m25 concrete including intercepting chamber and screen chamber made of brick masonary in cm, rcc cover slab in m25/ sfrc cover, interconnecting pipes of rcc/dwc complete filled with brick bats of size 3m dia and 3 m depth. 26 s&f pvc junction boxes ip 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 nos mcb sp 2.5 amp & 4 way industrial connector including clamp made out of ms flat 30x5mm connection from junction box to street light fitting with three single core pvc insulated, pvc sheathed wire 2.5 sqmm copper & pvc conduit 20 mm dia complete all as specified and directed by engr-in-charge. 27 excavation in trenches by cutting of road crossing/pcc hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by engr-in-charge. 28 s&fht/lt ms cable route indicator 4 dia fixed with two nos of nut, bolt and washers and provision of pcc 1 : 4 : 8 type d-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by engr-in-charge. 29 supply, installation, testing and commissinoning lt panel board suitable for working on 3 phase ,4 wire ,415 volts, ac ,50hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick crca sheetduly powder coated and shall be cpri approved and as approved by ge. the panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, copper bus bar duly covered with heat shrink sleeves colour coaded duly fixed ondmc/smc insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing mccbs shall have extended bus bar links and mounted on 50x50x5mm sizems angle iron frame duly painted including pcc 1:2:4 type b1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of age (i) nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) mccb 400 amps, fp, 36 ka, 415 volts, 50hz - 01 no (i/c)(b) mccb 200 amps, fp, 25 ka, 415 volts, 50hz - 02 no ( chs)(c) mccb 125 amps, fp, 18 ka, 415 volts, 50hz - 04 nos (apfc, tpn db -02, spare )(d) mcb spn 40 amps, 10 ka, 220 volts, 50hz - 03 nos (garage,street light, spare-1)(e) on load chengeover 630 amps 4 pole -01 no (f)digital voltmeter, with vss - 01set(g) digital ammeter, with cts & ass - 01 set(h) led phase indication lamps ryb - 01 set(j)single phase rotary automatic light controller nature switch with voltage range 120-440v,ac,20 amps,ip-65,50hz-01 nos(k) copper bus bar tpn 600 amps rating - 01 set 31 labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and gi tubing in soft/loose soil complete all as specified. 32 m&lfor cutting existing gi pipes and insertion of new tee branches of suitable size to take branch connection of 50mm dia pp-r.note : suitable size of tee branch is deemed to be included in the quoted rate. 33 construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingpcc in foundation of the mixture (1:4:8) d-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) ms steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed ms work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in pcc with two coats of black bituminuos paint andall other relevant work complete . 34 m&l for providing tracer/anti freezing cable required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (central heating system)electric hot water generator : supply, installation, testing and commissioning ofpackage type electric hot water generator constructed out of ms sheet having top open-able cover for easy access and removal of heaters. the hwg shall be suitable for indoor mounting. the generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22g aluminium cladding sheet. the generator shall have electrical capacity of 50 kw. the heater shall be electrical resistance type, copper tube with chromium plating. the generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. the generator shall be suitable for 3 phase, 415+ 10% volts, 50 hz. ac supply. the generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 notes:- (i) allneccassary accessories required for the proper fucntioning of hot water genearator are included in price.(ii) the prices should include lifting, shifting and positioning of units at site.(iii) hot water genearator installation to done as per manufacturer recommendation with all installation requirements i.e foundation, vibration isolator,insulationetc as recommended by manufacturer for the ambient temperature of site. odu installation is included in odu price which includes the civil struture, mechanical structureetc as recommended bymanufacturer.(iv) the contractor/oem will shall submit the hot water generator capacity/burner capacity conforming to relevant is code(v) oem should submit the installation and maintenance schedule/ manual for the boiler. 37 glycol circulation centrifugal pumps: supply, installation, testing & commissioning of pn16 ratedaxial split coupled vertical inline water pump set with ci casing, bronze impeller, ss shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with suitable hp, tefc squirrel cage induction motor with ie3 type class f insulation, motor shall be rating of ip 55, operating on 415 ±10% volts, 3 phase, 50hz ac supply. the external flush line must be used for the purpose of heat dissipation from the mechanical seal.pumps with performance characteristics as given below:the internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 degree celcius to 120 degree celcius. vendor shall be provide antivibration arrangement for pumps . 38 the scope also shall include following below mentioned:(i) electrical by pass starter for pump setas recommended by oem. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) pressure gauges 150 mm dia -03 nos (iv) mounting frame with antivibration pads (in case pumps are inline, anti vibration system shall be as per manufacturers recommendation) (v) rcc/cement concrete foundation for the pump unit. (in case pumps are inline, foundation shall be as per manufacturers recommendation).pump capacity are as under:capacityand pump headnot less than flow 25 usgpm , head 20 mtr (refernce model no. : armstrong : series 4300 - 40-150 - 2p - 1.5 kw) each including the triple duty valve and end suction guide. 39 expansion tank and pressurisation unit:supply, installation, testing and commissioning of insulated pressurised closed water expansion tank suitable for total volume ofglycol - water solution, circuit along with necessary accessories such as along with necessary accessories such as 2 nos pumps (1working +1standby) with pressure transmitter andinterconnecting pipe & isolating valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with pressure transmitter andinterconnecting pipe & isolating valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. the tank shall be pre-charged. expansion tank shall be with replaceable heavy duty butyl rubber bladder. the tankconnections should be as per oem recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.the tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. the tank must be constructed in accordance with is-standard 2825-1969 (withlates revision)and rated at pn 16 . the complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.the tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelip55 control panel, pressure transmitter, interconnecting piping & wiring. (tank capacity 500 ltrs). hot glycol - water closed vessel pressurized expansion tank as described above shall be duly insulated with 50 mm thick puf/nitrile rubber insulating material or equivalent u valueinsulating material and cladded with aluminium sheet (20g). electrical by pass starter for pump setas recommended by oem. 40 expansion tank of 500 lts capacity 41 pressurization unit: for pump set -03 nos with control panel and accessories. 42 make up tank: supply, installation, testing and commissioning of factory made make up water tank, rectangular/circular shape, of 4 mm thick ms sheet (is 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of ms and vent with flame arrestor. tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above ffl. service platform shall be provided as per recommendations of oem. the tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. extra high level and extra low level alarm shall be provided. tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.make up water tank as describedabove should beduly insulated with 50 mm thick puf/nitrile rubber insulating material and cladded with aluminium sheet (20g). 43 supply, installation, testing and commissioning ofsteel plate radiator( wall mounted) confirming en- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°c, complete with top grill side cover as standard along with inlet ,outlet valve, air purge valve andwith threaded plug, flow regulator as per oem.the below desired capacity should be calculated at altitude of 3600 mts above sea level. capacity calculation sheet to be provided to engineer in charge. the below mentioned capacity is at inlet temp: 75 degree celcius , outlet temp: 65 degree celcius. referemcwe model series. 44 1.5 kw, type: 33- dkek, length is 1000 mm and height is 600 mm of radiator. 45 2.5 kw, type: 33- dkek, length is 1000 mm and height is 600 mm of radiator. 46 3.5 kw,type: 33- dkek, length is 1600 mm and height is 600 mm of radiator. 47 5 kw,type: 33- dkek, length is 1600 mm and height is 900 mm of radiator. 48 5 kw,type: 33- dkek, length is 2000 mm and height is 600 mm of radiator 49 m & l for pre-insulated ms pipe,class c havingminimum thicknes of puf insulation as mentioned below and of density 36 kg/cum and 26 gauge al cladding complete suitable for above ground as per sizes shown.the pipes should be insulated with closed cell puf of density 36±2 kg/cum of below mentioned thickness. the pipe should be workable in the temp. range of-50 degree celciusto120 degreec celcius. note:-the pipes size 150mm & below shall be m.s. ‘c’ class as per is : 1239 50 80 mm with 36 mm puf thicknes and 26 gauge al cladding. 51 50 mm with 36 mm puf thicknes and 26 gauge al cladding. 52 50 mm with 36 mm puf thicknes and 26 gauge al cladding. 53 40 mm with 36 mm puf thicknes and 26 gauge al cladding. 54 20 mm with 36 mm puf thicknes and 26 gauge al cladding. 55 buried under ground/exposed to ambient:80 mm with 50 mm puf thicknes and hdpe cladding, 26 gauge al cladding. 56 cabel tray :-supplying and installing following size of perforated painted with powder coating m.s. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/ground/wall with m.s. suspenders as per is code including bolts & nuts, painting suspenders etc. as required of size 150 mm width x 50 mm depth x 1.6 mm thickness 57 supplying, fixing, testing and commissioning of following diameter valves (pn-16 rating) (complete with flanges integral or welded, fittings, nuts, bolts & gaskets (pn-16 rating), strainers (complete with flanges integral or welded, fittings, nuts, bolts & gaskets (pn-16 rating), gauges etc for condenser water circulation as per specifications. insulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as specified. butterfly valve ( insulated valves) with ci body ss disc nitrile sheet & o ring, complete with fittings, nuts, bolts & gaskets.butterfly valve ( insulated valves) with ci body ss disc nitrile sheet & o ring, complete with fittings, nuts, bolts & gaskets. 58 80 mm dia butterfly valve 59 65 mm dia butterfly valve 60 50 mm dia butterfly valve 61 supplying, fixing, testing and commissioning of y-strainer (insulated valves) of ductile ci body flanged ends with stainless steel strainer forhot water circulation including insulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as specified of size 50 mm dia y strainer. 62 supplying, fixing, testing and commissioning of non - return valve (insulated valves) with duel plate of ci body ss plates vulcanized nbr seal flanged end & pn 16 pressure rating forhot water circulation includinginsulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as sepcified of size 50 mm dia nrv. 63 supplying, fixing, testing and commissioning of automatic air purge valves forhot water circulation headeras specified of size automtic air purge valve 20 mm dia. 64 supplying, fixing, testing and commissioning of air separator compleate allas specified of size 50 mm dia. 65 supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and ss tubing, socket.range (0-50) / (0-100) as required by engineer in charge. 66 supplying, fixing, testing and commissioning of mercury in glass industrial thermometer in ss-304 casing with 0.5 c least count, range 0-50 c. brass oil filled thermowell of 1/2 size as required by engineer in charge. 67 electrical distribution panel supply, installation, commissioning and testing of factory made, chs plant, indoor type made out of crca sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with ms angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 phase4 wire, 415 volts, 50 hz, ac supply system, floor mounted and grounting the legs of panel in pcc foundation 1:4:8 complete as all directed suitable for and including the following :- 68 incomers(i) bus bar tpn al extensible type main bus bars of minimum of 600 a capacity (as per capacity of corresponding incoming / bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c smc bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50ka .(ii)mccb 400 amps, 415 volt, 36 ka, 4 pole,microprocessor release- 01 no for incoming (extended rotary operating handle, phase spreader links and phase barriers ) make: legrand/schenider/simensoutgoings(i) 3nos- 125a ,25 ka tpnmccb/acbwith microprocessor release (3# hot water generator)(ii) mcb 10 amp,tpn,10ka, c curve - 06, 3 nos for pumps , 2 nos for pumps ,01 nos for glycol transfer pump(iii) led phase indication lamps (01 set) with 2amp back up mcb,breaker on/off indicating light with 2a mcb, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 set (iv) digital ammeter with in built ass,metering c.t.scast resin type, 15va, and accuracy class-1of 800/5a for measuring current in each phase - 01 set.(v) all accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per manufacturers recommendations all as directed by engnr-in-charge.note : contractor will submit the drawing for approval of panel to ge before execution. 69 lt cables : supply & laying/ fixing of following size xlpe insulated and pvc sheathed copper conductor armoured cable/unarmoured as required of 1.1 kv grade complete as require (isi marked) (in ground/in pipe/in duct/on surface/on cable tray) 70 3.5 core x 70 sq.mm. (electric hot water generator) 71 4.0 core x 10 sq.mm. (pump) and (pressurization unit) 72 2 core x 10 sq.mm. (pump) 73 2 core x 6 sq.mm (pressurization unit) 74 earthing complete with copperearth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long gi pipe connected to main controlboard and gi pipe light grade 20mm bore for watering and including funnel, wire mesh, rcc pit cover 50mm thick and pcc chamber pit with pcc 1:2:4 type c2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate no 3 of ssr part-i 2009 complete all as specified & directed by engr-in-charge 75 s&f rubber matting conforming to is-15652-2006 complete as required. of size2m x 1m x 25 mm 76 glycol - water solutionsupplying of ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.note;- (i) the glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. the glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 degree celcius (ii) first charge of glycol is included in the quoted rate. first charge include charge in chs pipe linestorage tank. (glycol 45 % ,water 55 %) 77 for chs 78 supply of gycol for running of plant for 12 months 79 glycol circulating pump: supply, erection, testing and commissioning oftransfer pumps for the capacity of 5 lpm 5 meter head for glycol fluidtransfer with base frame foundation, bolts coupling coupling guard,tefc, (oem design hp for the required flowand head ) andother accessories for proper function of the pump. 80 oxygen gas manhold : supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, nrv and essab make 10x14 regulator complete all as specified and directed by engr in charge . 81 supply , installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by engr in charge . 82 supply , installation , testing and commission automatic control panel with analog display 02 for oxygen complete all as specified and directed by engr in charge. 83 s&f of copper tubing of size 15 mm od, en -13348 grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by engr in charge. 84 s&f of copper tubing of size 12 mm od, en -13348 grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by engr in charge. 85 s&f bs type gas outle with probe for oxygen for medical compleate all as specified and directed by engr in charge 86 s&f 1/2 brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by engr in charge. 87 s&f bpc flow meter (0-15 lpm) including humidfire bottle complete all as specified and directed by engr in charge . 88 s&f 3/8 brass ball valveincluding all fittings for complete all as specified and directed by engr in charge. 89 stand by dg set : supply,install, test and commissioning of silent diesel engine generating set 415 volts, 3 phase, 4 wireengine as per is08528 conforming to cpcb norms iv, and alternator as per is08528 of capacity 400 kva at ntp with control panel having meters, sound proof canopy etc with foundation (as per oem design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- ac generator should be suitable for ambient conditions at nimu leh area. 90 (a) alternator : standard design alternator rated at 400 kva (320kw)net output at power factor 0.8, ac, 3 phase 4 wire, 415 v, 50 cycles/second, 1500 rpm self excited, self regulated, screen protected, drip proof ip 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (b)diesel engine : vertical diesel engine of suitable capacity, water cooled, closed circuit as per bs-649 or is-1002 direct injection type turbo charged, electric starting system having rated speed 1500 rpm. the dg set shall be capable for running with 10% over loading for 01 hour in every 12 hours as perbs-5514/bs-649. engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following specifications.(a) fly wheel with housing (i) common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) cooling system (i) radiator with fan & belts & guard, rubber hoses and thermostat. (ii) cooling water pump centrifugal type . 91 (c) governer : electronic governer (d) electric starting system : electric self starter , 24 volts dc(12 volt, 150 ah battery 2 nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2x12 volt 150 ah capacity. (e) generator monitoring panel : comprising of following :- (i) microprocessor based genset controller for metering, monitoring, governing and protection. (ii) engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) accessories:avm pads built or separately mounted to manufacturer base frames. (g) coupling arrangements: fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) exhaust system : should have equipped with emission control device as per latest govt norms. silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) fuel tank: daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (c)acoustic enclosure : all as per cpcb norms iv and oem of dg sets design.(d)amf panel : supply, install, testing and commissioning of amf panel outdoor type, cubical body,dust and vermin proofmade up of crca sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to ip 45 with front and rear opening with louvers andmounted on floor with pcc pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) microprocessor based panel -01 no(ii) power contactor heavy duty suitable for generator and mains (iii) over load relay for genset (iv) suitable rating isolating switch mccb for both dg & main supply.(v) multi functioning meter to indicate voltage, current, frequency, p f, kw & kwh etc (vi) emergency stop push button.(vii)set of indicaters : - (a)low lube oil pressure (b) dg set over load(viii) push button to start, stop (ix) mode selector switch i.e auto/manual/test/ off.(x) set of instrument fuse (xi)set of aluminium bus bar of 600 amps capacity 3 ph, 4 wire system (xii) automatic battery charging unit with dc voltmeter, ammeter and selector switch for trickle/ boost charging.(xiii) by pass arrangement of main supply when amf circuit fail due to any fault with provision of suitable rating change overs and switches. 93 the following items are deemed to be included in the rate quoted for all dg sets:- (i) dhpp for testing purpose shall be supplied by the contractor without any extra cost to department. (ii)the contractor shall arrange for artificial load (water load/electrical load) for testing for final testing of dg set at site and the cost is deemed to be including in above offer. (iii) testing of sound level should carried out at the site in presence of engineer-in-charge(iv) one set of latest spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) all civil works including foundation for dgset as per manufacturers drawing/ specification, foundation for amf panel shall deemed to be included in the quoted rate.(vi) the rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
  • View Tender
  • Document
  • Bid Support
  • 1
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : electrical insulator
  • Ceramic Fiber Tape Tenders ,
  • Insulation Sheet Scrap Tenders ,
  • Insulation Foil Tenders ,
  • Insulation Oil Tenders ,
  • Insulation Services Tenders ,
  • String Insulator Tenders ,
  • Piston Insulator Tenders ,
  • Insulation Board Tenders ,
  • Under Deck Insulation Tenders ,
  • Porcelain Insulator Tenders

Get electrical insulator Tender Alert...

900321

Related Searched Keywords : electrical insulator

  • Tiles Flooring Tenders From Maharashtra
  • Water Sump Well Tenders From Delhi
  • Rcc Roofing Tenders From West-Bengal
  • Wire Fence Tenders From -Tamil-Nadu
  • Lift Irrigation Service Tenders From Andhra-Pradesh
  • Vinayl Flooring Tenders From Gujarat
  • Piling Tenders From Karnataka
  • Desalting Tenders From Uttar-Pradesh
  • Plastering Tenders From Rajasthan
  • Wall Work Tenders From Madhya-Pradesh

Read More


Tender Document

271741

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Subways Tenders
  • Infrastructures Work Tenders
  • Horizontal Boring Machine Tenders
  • Civil Infrastructure Work Tenders
  • Lift Irrigation Project Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App