Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Chain Link Fencing Panel
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of chain-link-fencing-panel Tenders

List of latest chain-link-fencing-panel Tenders in Indian Tenders. Click on any chain-link-fencing-panel Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for chain-link-fencing-panel Tenders.

Advance Search
  • All-Tenders (20)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
1 Railway Transport
image image
Central Government/Public Sector
TRN :49051353 |  15 May, 2025
Tender Value : 0
 Halisahar - West Bengal
Tender for auction sale of p.l. no. 98057054. scrap melting gr-d consisting of cutting sol bar, fall plate, head stock, cutting outside panel, trough floor, cab window assly. trolley, plate cutting, angle cutting, iron axle with pipe, cover of tail light head light flasher etc. tie bar fencing, pipe cutting, structure cutting, cut pieces of rod, damage emu door down rod for celling fan, mvmt,tmb,emu,mvsi impeller,mvsi duct, air duct, fan chamber, electrical pillar box, compression spring of bk cylinder, inter/after cooler tube type, lid of grease drums, partition frame, cattle guard, ms base, l.t. panel box ferrous, electrode holder, tap changer, expanded metal, vsb packing, bs door, iron window, ms rod , fire extinguisher, dip lorry, gate, nut , bolt, washer, wick felt carriers, pin, angle frame with or without net, r.s. joint, ms iron plate, angle, door shutter, cutting chain, net box, fencing wire and such materials fit for melting gr-d, except p-way materials , rail, fish plate and non ferrous etc. qty-175mt. location-north of link road, east of inner boundary wall. condition-cutting is allowed for loading purpose only. delivery to be made in actual weighment basis through lorry.
  • View Tender
  • Document
  • Bid Support
2 Rural Development
image image
Local Bodies
TRN :49054292 |  26 May, 2025
Tender Value : 2.96 Crore
 Firozabad - Uttar Pradesh
Tender for tender for construction work of theme park with in municipal corporation firozabad. - art work 2 shree banke bihari temple - the structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 20 feet. minimum width – 15 feet. minimum length – 28 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 3 cow - minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 8 feet. minimum width – 8 feet. minimum length – 12 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 4 krishna jhoola - minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 8 feet. minimum width – 5 feet. minimum length – 10 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 5 sheshnag - minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 12 feet. minimum width – 15 feet. minimum length – 30 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 6 morpankh- minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 15 feet. minimum width – 2 feet. minimum length – 6 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 7 pot- minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 10 feet. minimum width – 10 feet. minimum length – 12 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 8 fluite- minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 8 feet. minimum width – 2 feet. minimum length – 20 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 9 goverdhan parvat.- minimum area as per below details, using the scrap/waste material available at the sites . minimum height – 20 feet. minimum width – 6 feet. minimum length – 20 feet.foundation/base specs if requires–brickwork all around the platform as a base for the platform on which installation shall be placed pcc below the concrete slab rcc m - 25 if required. with vacuum dewatering external pavers / stone tiles on top of rcc slab, if required. designing, fabrication,installation of to be made from scrap/waste material. the miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. for finishing while installation of miniatures / sculptures applying primer coats (two or more coats) of approved quality primer, painting with p.u. coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 10 external lighting work 11 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63mm dia (od- 63 mm andid 51 mm) 12 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90mm dia (od- 90 mm andid 76 mm) 13 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 120 mm dia ((od- 120 mm andid 103 mm) 14 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required. 15 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a )25 mm 16 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required . 17 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required . 18 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required . a)single pole 19 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required .b)single pole and neutral 20 supplying and fixing following rating ,four pole (three phase and neutal),415 volts, residual current circuit breaker (rccb) having a sensitivity current 30 ma in the existing mcb db complete with connections,testing and commissioning etc.as required.40a 21 supplying and fixing following rating ,four pole (three phase and neutal),415 volts, residual current circuit breaker (rccb) having a sensitivity current 30 ma in the existing mcb db complete with connections,testing and commissioning etc.as required.63 a 22 providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required . b) 125 a,36ka,fpmccb 23 supplying, instalaltion, testing & commissioning of1.1 grade, 3x1.5sqmm frls pvc insulated flexible copper conductor, single core cable in the existing surface/recessed steel/ pvc conduit as required. 24 supplying, instalaltion, testing & commissioning1.1 grade, 3x2.5sqmm frls pvc insulated flexible copper conductor, single core cable in the existing surface/recessed steel/ pvc conduit as required. 25 supplying, installation, testing & commissioning of following cable al. conductor xlpe insulated pvc tape inner sheathed for multi core cables , armoured as per is,pvc type st to sheathed 650/1100v grade as per is 7098 (part 1)19884cx4 sqmm 26 supplying, installation, testing & commissioning of following cable al. conductor xlpe insulated pvc tape inner sheathed for multi core cables , armoured as per is,pvc type st to sheathed 650/1100v grade as per is 7098 (part 1)19884cx6 sqmm 27 supplying, installation, testing & commissioning of following cable al. conductor xlpe insulated pvc tape inner sheathed for multi core cables , armoured as per is,pvc type st to sheathed 650/1100v grade as per is 7098 (part 1)19884cx10 sqmm 28 supplying, installation, testing & commissioning of following cable al. conductor xlpe insulated pvc tape inner sheathed for multi core cables , armoured as per is,pvc type st to sheathed 650/1100v grade as per is 7098 (part 1)19884cx16 sqmm 29 supplying, installation, testing & commissioning of following cable al. conductor xlpe insulated pvc tape inner sheathed for multi core cables , armoured as per is,pvc type st to sheathed 650/1100v grade as per is 7098 (part 1)19884cx25 sqmm 30 supplying, installation, testing & commissioning of following cable al. conductor xlpe insulated pvc tape inner sheathed for multi core cables , armoured as per is,pvc type st to sheathed 650/1100v grade as per is 7098 (part 1)19883.5c x 70 sqmm 31 supply, installation, testing and commissioning of 50 watt led floodlight luminaire 3000k colour temp. cri>70, led life 50000 burning hours 50° temp. surge protection up to 3kv, ip65 and ik 06 with die-cast aluminium housing, powder-coated finish, of following wattage.luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 v ac, 50 hz with power factor > 0.9 .luminaire shall be conforming to bis (is 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . 32 supply, installation, testing and commissioning of 30 watt led floodlight luminaire 3000k colour temp. cri>70, led life 50000 burning hours 50° temp. surge protection up to 3kv, ip65 and ik 06 with die-cast aluminium housing, powder-coated finish, of following wattage.luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 v ac, 50 hz with power factor > 0.9 .luminaire shall be conforming to bis (is 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . 33 supply, installation, testing and commissioning of 90 -100 watt led floodlight luminaire 3000k colour temp. cri>70, led life 50000 burning hours 50° temp. surge protection up to 3kv, ip65 and ik 06 with die-cast aluminium housing, powder-coated finish, of following wattage.luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 v ac, 50 hz with power factor > 0.9 .luminaire shall be conforming to bis (is 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . 34 supply,installation,testing and commissioning of 25-30 watt warm white ledlinear wall washer luminaire cct 3000k ± 250k for illuminate 3d wall painting with aluminium extruded housing. length of the luminaire shall be 1000mm in size.luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270vac ,50hz , powerfactor>0.9. fixture shall be suitable to operate at ambient temperature range of-5°cto+50°c and shall be ip65 and ik06 rated. lifetime should be at least l70:50000 burning hours at 50°c. luminaire shall be conforming to bis and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required engineer-in-charge. the branding name shall be embossed on the housing of the fixture. the minimum warranty shall be for 2 years. 35 supply,installation,testing and commissioning of 40-45 watt warm white ledlinear wall washer luminaire cct 3000k ± 250k for illuminate 3d wall painting with aluminium extruded housing. length of the luminaire shall be 1000mm in size.luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270vac ,50hz , powerfactor>0.9. fixture shall be suitable to operate at ambient temperature range of-5°cto+50°c and shall be ip65 and ik06 rated. lifetime should be at least l70:50000 burning hours at 50°c. luminaire shall be conforming to bis and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required engineer-in-charge. the branding name shall be embossed on the housing of the fixture. the minimum warranty shall be for 2 years. 36 sitcjunction boxes outdoor type supply made of thermoplastic polycaronateboxes mini. size 93 x 93 x 62 mm in black colour. the junction box should be ip 67/69 ( iec 60529 ) thermoplastic pc weatherproof with multi level knockouts on four side for cable entry in different sizes . lid fasteners shall not have screws but shall be with quarter turn locking knobs – which is well visible ( open – locked), and they will be sealable without any accessories. the box should be uv resistant in accordance with iec 61 439-1, clause no 8.4.4. the joint box should be weatherproof : rainwater proof, temperature resistant, connecting box as per iec 60670-22 and iec 60695 – 2 – 11 : flame – retardant & self-extinguishing. glow wire tested at minimum 750 deg c. the box shall have elongated holes inside and suitable brackets outdoor fixing them for wall/pole mounting provision with suitable terminals . the junction box with nut bolts complete all as per manufacturer’s instructions.make : cat part :- kf 0202 b of hensel/siemens/ge power/schneider/ l&t/abb. manufacturer should submit test certificate as per above standard. 37 sitcjunction boxes outdoor type supply made of thermoplastic polycaronateboxes mini. size 205 x 255 x 112 mm in black colour. the junction box should be ip 67/69 ( iec 60529 ) thermoplastic pc weatherproof with multi level knockouts on four side for cable entry in different sizes . lid fasteners shall not have screws but shall be with quarter turn locking knobs – which is well visible ( open – locked), and they will be sealable without any accessories. the box should be uv resistant in accordance with iec 61 439-1, clause no 8.4.4. the joint box should be weatherproof : rainwater proof, temperature resistant, connecting box as per iec 60670-22 and iec 60695 – 2 – 11 : flame – retardant & self-extinguishing. glow wire tested at minimum 750 deg c. the box shall have elongated holes inside and suitable brackets outdoor fixing them for wall/pole mounting provision with suitable terminals . the junction box with nut bolts complete all as per manufacturer’s instructions.make : cat part :- kf 02525 b of hensel/siemens/ge power/schneider/ l&t/abb. manufacturer should submit test certificate as per above standard. 38 providing and fixing of flexible led strip fixtures suiatable for rated voltage 220 volts, 50 hz supply in white /green/red/warm white color including all accessories like connectors, endcap,holding cap and connector pins but excluding integrated led adoptor etc as required. 39 providing and fixing of integrted led adaptor forflexibleled strip fixtures suiatable for rated voltage 220 volts, 50 hz supply etc as required. 40 horticulture 41 horticulture ficus benjamina (green) height 150-165 cm., bushy with healthy branches and lush green foliage in big size hdpe bag 42 supply of ficus panda of height 45-60 cm. with 6-7 branches and healthy foliage in polybag of size 25 cm as per diraction of officer-in-charge 43 supply of rhapis palm having ht. 45 cm to 60 cm with 5 to 7 suckers, well developed,full of fresh andhealthy leaves in 25 cm size of earthen pot / plastic pot. as per direction of the officer-in-charge 44 supply of areca palm having ht. 1.80 m to 2.10 m with 8 to 10 suckers, well developed, fresh and healthy with lush green foliage in hdpe bag as per direction of the officer-in-charge 45 supply of wadelia trilobata,full of leaves in 15 cm size in plastic bag as per direction of the officer-in-charge 46 supply of syngonium (butterfly) variegated with 2-3 suckers healthy foliage in earthen pot/ plastic pot of size 25 cmas per direction of the officer-in-charge 47 supply of iresine herbstii, of height 25-30 cm., full of branches well developed in 15 cm size of earthen pot / plastic pot. as per direction of officer-in-charge 48 providing and fixing furcaria variegated hybrid well developed with fresh & healthy foliage 20 and above attractive leaves in 35 cm cement pot as per direction of the officer-in-charge. 49 providing and displaying topiary of ficus panda well developed with fresh & healthy foliage with 3 to 4 ball and 60 to 75 cm spread each ball, 135 to150 cm ht., in 35 cm hdpe bags /cement pot as per direction of theofficer-in-charge. 50 providing and displaying cyprus golden conical shape 150 to 165 cm ht., with fresh and healthy golden colour foliage in 35cm cement pot as per direction of the officer-in-charge. 51 providing and stacking of ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge. 52 providing and stacking of plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size hdpe bags as per direction of the officer-in-charge. 53 providing and displaying cycus revoluta in 35 cm challi, specimen , having 30 to 40 with fresh and healthy, leaves having 25cm to 30cm circumfrance of base stem well developed as per direction of the officer-in-charge. 54 providing and displaying bismarckia palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm cement pot as per direction of the officer-in-charge. 55 providing and fixing fishtail palm ht. 240cm bottom girth 40-50 cm well developed in big hdpe bag 56 civil work 57 earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by engineer-in- charge:all kind of soil 58 construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mix plant at omc, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of engineer-in-charge.with material conforming to grade-i (size range 75 mm to 0.075 mm) having cbr value-30 59 providing and laying at or near ground level factory made kerb stone of m-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of engineerin- charge (length of finished kerb edging shall be measured to calculate volume for payment). (precast c.c. kerb stone shall be approved by engineer-in-charge). 60 providing and laying 60 mm thick faciory made cement concrete interlocking paver block of m -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of engineer-in-charge. 61 constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand)cluding 500x450 mm pre-cast r.c.c. horizontal grating with frame complete as per standard design : 19.27.1 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 62 providing and fixing g.i chain link fabric fencing of required width in mesh size 50x50mm including strengthining with 2mmdia wire or nuts,bolts and washer as required 63 steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required.in gratings, frames, guard bar, ladder, railings, brackets, gatesand similar works 64 cc for flooring provision and laying in position cement concrete of specified grade excluding and cost of centering and shuttering. allwork upto plinth level in cc 1:3:6 (1 cement: 3coarse sand: 6 graded stone aggregate 20 mm nominal size) 65 brick work with common burnt clay modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand). 66 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand) 67 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
  • View Tender
  • Document
  • Bid Support
3 Security Services
image image
Central Government/Public Sector
TRN :49055122 |  29 May, 2025
Tender Value : 40.00 Lacs
 Palam - Delhi
Tender for comprehensive maintenance and certain misc b/r works in tech area at af stn palam under ge (af) palam, delhi cantt - 10; 1.00 taking down cement plaster on brick, stone or concrete surfaces of walls etc incl racking out joints hacking for key scrubbing down with water etc and removing the debris from site to out site mod land complete all as specified and directed by engr-in-charge . 2.00 m&l for 10mm thick rendering of ready mix mortar of approved make on brick work or concrete surfaces on internal walls, finished the surface even and smooth without using extra cement as on wall as whole or in patch etc complete all as specified and as directed. make- birla (hil) or its equilent. 3.00 m&l for 15mm thick rendering of ready mix mortar of approved make on brick work or concrete surfaces on external walls, finished the surface even and fair without using extra cement by using dr. fixit (wpc) @ 3% of wt of cement content complete all as specified and as directed. note:- water proofing compound shall be measured and paid seprately. 4.00 m&l for 5mm thick cement plater of ready mix mortar of approved make as on ceiling & plastering to be finished even & smooth without using extra cement complete all as specified and as directed. make- birla (hil) or its equilent. 5.00 supply only integral water proofing compound complete all as specified and as directed. 6.00 m&l for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkalic resistent primer complete all as specified and as directed 7.00 m&l for applying two coats of 100% premium acrylic emulsion paint having voc less than 50 gm/ltr and uv resistance as per is 15489-2004, alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.9 litre /10 sqm over new surfaces complete all as specified and as directed. 8.00 m&l for preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of alkalic resistent primer complete all as specified and as directed. 9.00 m&l for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster (1:4) (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and as directed. note:- payment for providing grooves shall be measured and paid separately. 10.00 m&l for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications complete all as specified and as directed. 11.00 demolition of cement concrete (un reinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) and removing the debris from site to out site mod land complete all as specified and as directed. 12.00 m & l for 75mm thick cement concrete (1:3:6) type c2 (using 40mm graded stone aggregate) as in plinth protection, finished even and smooth without using extra cement, including making joints 12 mm wide to the full depth of pcc at every 3 metres and at every change of direction and filling the same with & including bitumen 85/25 and sand in the proportion of (1:3 ) by weight complete all as specified and as directed. 13.00 m&l for 75mm thick pcc (1:3:6) type c2 (using 40mm graded stone aggregate) as in path and paving, finished even and smooth without using extra cement complete all as specified and as directed. 14.00 m&l for 25 mm thick pcc (1:2:4) type b1 (using 20mm graded stone aggregate) as in floor, finished even and smooth with using extra cement complete all as specified and as directed. 15.00 m&l for plain cement concrete (1:3:6) type c1 (using 20 mm graded stone aggregate) as in surface channel/drain complete all as specified and as directed. 16.00 extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and as directed. 17.00 supply and fixing in repairs, sfrc drain cover any size, 75mm thick laid over existing drain complete all as specified and as directed by engr-in-charge. notes: - (i) make of sfrc manhole/drain cover and frame : (a) m/s ps concrete.(b) m/s kk manhole.(c) or equivalent as approved by ge. (ii) contractor will provide manufacturer test certificate of sfrc cover . 18.00 dismantling wall and ceiling boards ( fibre, pulp, insulation etc.) or insulation boards / slabs / blankets, any thickness, including fillets complete all as specified and as directed. 19.00 m & l for provding false ceiling of 12mm thick fine fissure board sharped finished mineral fiber accountic false ceiling tiles with back of the duly sanded and finshed with a coat of protective paint and front duly finished false system of size (600x600) mm having noise reduction co-efficient of 0.55 light reflection of 80% thermal conductivity k=0.057 w/wwc and humidity resistance of 95% fixed to true look pvc die kl -24 suspension system (hot dipped aglvanised steel section) of exposed t section consisting of perimeter wall angle of size (24x24) mm of thickness 0.45 of mm c/c universal main runner of t shape with double rotary siticing of size (38x25) mm of lenght 1200mm made from 0.33gs steel of lenght 3.60 mtr to be spced at 600x 600mm size) c/c cro runner t shape wtih double rotary siticing of size (30x24)mm of length 1200mm made 0.25 thick gs sheet spaced @ 600mm c/c (600mm 600mm) size complete all as specified and directed by engineer -in- charge. 20.00 taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 sqm each including cutting holes in walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified and as directed. 21.00 taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size exceeding 1.50 sqm but n. exc 4.0sqm each including cutting holes in walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified and as directed. 22.00 taking down shutters of any description of size n. exc 1 sqm each complete all as specified and as directed. 23.00 taking down shutters of any description of size exc 1 sqm and n exc 2 sqm each complete all as specified and as directed. 24.00 taking down shutters of any description exc 1 sqm and n exc 2 sqm each and re-fixing in the same opening after necessary repairing viz shifting of hinges/tower bolt / handle position etc complete all as specified and as directed. note:- cost of screws/nails and minor items shall be deemed to be included in the unit quoted rates. 25.00 s&f anodised aluminium powder coated frame for door, windows, ventilators, partition wall with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed 26.00 s&f anodised aluminium powder coated door shutter, aluminium section wt 0.55 kg/m including neccesary joining cleats, glazing clips, rubber neoprene packing, aluminium handle 2 nos in each door, hinges, anodised aluminium snap beading screw etc. complete all as specified and as directed. 27.00 s&f anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised, handle 2 nos in each window, aluminium fittings such as peg stays150mm long (1 no.), hinges type b-21100mm long (2 no.), suitable handle (1no.) complete all as specified and as directed. 28.00 s&f aluminium anodised with powder coating (minimum thickness of powder coating 50 micron) grill of design and parttern as approved by ge including aluminium beading complete all as specified and as directed. 29.00 s&f 5.50mm thick tinted, sheet glass of selected quality fixed to aluminium frame work complete all as specified and as directed. 30.00 m&l for 12mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination & fixed with screws to timber/aluminium frame complete all as specified and as directed 31.00 s & f door closer hydraulically regulated designation no 3 universal type suitable for door shutter of 851 to 1000 mm in width of aluminum body (die cast) weight between 61 to 80 kg complete all as specified and as directed. 32.00 m&l double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminum alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other party made of mild steel heavy duty complete all as specified and as directed. 33.00 s & f mild steel mortic lock vertical type size 100mm 4 levers complete all as specified and as directed. 34.00 s&f aluminium tower bolt of extruded section, 150mm length of bolt and fixed with screws complete all as specified and as directed. 35.00 s&f aluminium door stopper double legged with rubber shoe 75mm long fixed to door shutters complete all as specified and as directed. 36.00 m & l 2nd class hard wood plain, solid, straight chowkhats, and frame wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed. 37.00 s&f for 30mm thick factory made flush shutter, solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and as directed. 38.00 s&f for factory made single extruded wpc (wood polymer composit) solid door/window and other frames/chowkhat of size 50x100 mm comprising of virgin pvc polymer of k value 58-60 (suspension grade) calcium carbonte and natural fibers (wood powder/rice husk/wheat husk) and non toxic aditives(maximum toxicity index of 12 for 100 gms) fabricated with full body threaded star headed ss screws having minimum frame density of 750 kg/cum screw withdrawl strength of 2200 n(face) & 1100n(edge) minimum compressive strength of 58 n/sqmm modules of ealsticity 900 n/sqmm and resistance to spread of flame of class a category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with ms hold fast/ lugs/ss dash fasteners of required dia and length complete as per direction of enger-in-charge. make- m/s rajshree plastiwood ltd or its equivalent as per list of make. 39.00 s&f for factory made single extruded wpc (wood polymer composit) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of k value 58-60 (suspension grade) calcium carbonte and natural fibers (wood powder/rice husk/wheat husk) and non toxic aditives(maximum toxicity index of 12 for 100 gms) fabricated with full body threaded star headed ss screws having minimum frame density of 650 kg/cum screw withdrawl strength of 1800 n(face) & 900n(edge) minimum compressive strength of 50 n/sqmm modules of ealsticity 850 n/sqmm and resistance to spread of flame of class a category with property of being termite/borer proof, water/moisture proof and fire retardant. wpc to be laminated with pvc foil of minimum 14 microns thick of approved design pasted with hotmelt adhesiv on both faces of shutter and fixing with stailess steel butt hinges of required size with necessary full body threaded star headed counter sunk ss screws all as direction of enger-in-charge. make:- m/s rajshree plastiwood ltd or its equivalent as per list of makes. 40.00 dismantling of floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles and rubbish off the premises complete all as specified and as directed. 41.00 m&l for vitrified ceramic tiles 8-10 mm thick, 1st quilaty (square/rectuangular) polished, double charge shade, area of each tiles exceeding 0.36 sqm but not exc. 0.42 sqm, as in floors etc. set and jointed with neat cement slurry and pointed in white or coloured cement to match with and including over15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. 42.00 description all as per srl item no. 39.00 bove but as in skirting over 10mm thick plastering with cm (1:4) complete all as specified and as directed. 43.00 m &l for ceramic coloured/ printed non-skid tiles of size 7 to 8 mm thick( square / rectangular) area of each tile exceeding 0.06 sqm but n exc 0.16 sqm laid as in floors, set and jointed with neat cement slurry with and including over 15 mm thick screed bedding layers of cement sand mortar (1:4) and pointed with coloured cement to match with surfaces of tiles complete all as specified and as directed. 44.00 m&l for glazed ceramic coloured tiles (colour & shade as approved) of size (450x350)mm x 7mm thick as in vertical surfaces as in skirting and dado, set and jointed in neat cement slurry with amd including over 15mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified and as directed. 45.00 s&f in repair wash hand basin, vitreous china, flat back (550x400)mm size, white including pvc waste coupling 32mm size, pvc waste pipe 32mm bore, pair of brackets of mild steel (35 x 35 x 6)mm size including one mixer cast copper alloy 15mm bore, one brass stop valve 15mm bore and one pvc connection15mm size with ptmt nuts of length 450mm long complete all as specified and as directed by engineer-in-charge. 46.00 supply & fixing in repair vitreous china ewc super constellation including flushing cistern of size (83x37x66)cm with s trap complete all as specified and as directed. 47.00 supply & fixing in repair vitreous china urinal pot white including partition, waste pipe, screw with wall fixing complete all as specified and as directed. 48.00 s&f in repairs two way wall mixer with popup waste system, hot and cold facilites and 450 mm long braidaed hoses chromium plated complete all as specified and as directed . 49.00 s&f in repair health faucet with double lock 1 meter brass plated stainless steel flexible hose and wall hook complete all as specified and as directed. 50.00 s & f in repair copper alloy cp toilet paper holder complete all as specified and as directed. 51.00 m&l for replacement of 100mm ci floor/nahani trap with grating including jointing and breaking/ dismantling any type of floor and making good cement concrete type b-1 (1:2:4) and testing after repairs and taking down existing trap etc complete all as specified and as directed. 52.00 s&f in repair, brass chromium plated tubular towel rail, 20mm dia, d type, 60cm long between flanges complete all as specified and as directed. 53.00 taking up or down 15mm steel tubing and connections in walls, ceilins, floors, etc including cleaning for refixing or removal to store complete all as specified and as directed. 54.00 m&l for gi tubing, 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors etc complete all as specified and as directed. 55.00 m&l for cutting chases, pinning in making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc, and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good cutting not exc 10 cm girth as in wall complete all as specified and as directed. 56.00 s&f in repair 15mm bore cast copper alloy, cp angle cock, screwed down, high pressure, with crutch or butterfly handles, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. 57.00 s&f in repair pvc connections 15mm size with ptmt nuts of length 450mm and fixed complete all as specified and as directed. 58.00 s&f in repairs pvc connections 15mm size with ptmt nuts of length 600 mm and fixed complete all as specified and as directed. 59.00 s&f in repair cast copper alloy cp soap dish complete all as specified and directed. 60.00 s&f in repair bib taps with wall flange 15mm bore, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. 61.00 s&f in repair pillar cock, foam flow cast copper alloy, chromium plated, fancy type, 15 mm dia, capastan heads, screwed down high pressure complete all as specified and as directed. make:- cat no 8304 of make prayyag or equivalent as per list of makes. 62.00 s&f in repair plastic water closet seat cover, white/black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. 63.00 s&f in repair pvc valveless, syphonic action type, flushing cistern low level, 10 litre capacity , white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed. 64.00 s&f in repair 610 mm long pvc waste pipe flexible type 25 mm dia suitable for couplings 32 mm / 40 mm dia complete all as specified and as directed. 65.00 s&f in repair (600 x450) mm fancy type or bevelled edge mirror of selected quality glass, mounted on 6mm thick ac building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. 66.00 s&f in repairs 15 mm bore bib taps standard of ptmt any colour high pressure screwed for iron pipe and fixed complete all as specified and as directed. (minimum weight 90 gms). 67.00 s&f in repairs 15 mm two in one angle valve cast copper alloy, chromium plated with wall flange and fancy type with high pressure screwed down and with cp flange of same make complete all as specified and as directed . 68.00 m&l for 18-20mm thick granite (of jet black ) work (table rubbed and polished ) in steps, jambs, pillars, window cills, cooking plateforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. note:- the cost of half round moulding shall be deemed to be included in unit rate. 69.00 dismantalling water tanks and removal from site of capacity exc 250 ltr and not exc 500 ltr complete all as specified and as directed. 70.00 m &l for 500 litres capacity rotational moulded polyethene water storage tank (cylindrical vertical with closed top), white, three layers, hoisted and fixed in position complete all as specified and as directed. 71.00 supply and fixed ball brass valve high pressure with polythene float and fly nut complete to bore of pipe 20mm complete all as specified and as directed. 72.00 demolition of brick work or stone buillder built in cement mortar of any description complete all as specified and as directed. 73.00 m&l for brick work with sub class b works, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete complete all specified and as directed. 74.00 dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. 75.00 s&f mild steel work such as angle iron post, flat iron in fencing including cutting as making doubble swan neck i.e. y shaped including welding with proper overlapping & welding ms plate with angle iron bottom as directed, drilling holes notching for wire etc embedded in concrete fixed vertically conforming to fe 290 grade e-165 complete all as specified and as directed. note:- embedded portion of angle iron post shall be treated with tar of coat of tar black paint and cost of the same shall be deemed to be included in unit rate. 76.00 m&l for preparation of newly steel surfaces of any description over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer of any height complete all as specified and as directed. 77.00 s&f for concertina coil with punched tape of 600 mm dia (when stretched), centre core wire of minimum 2.5 mm dia of mild steel wire conforming to is 280-2006 with galvanised coating of steel concertina coil as per requirements laid down for medium coated wire in is : 4826 hot dipped galvainsed coating of round steel wires. conretina coil shall be fixed in diamond shape with the help of dovetail two handle and spikes shall be fixed at both end of coil,minimum straight length of the wire 150 rm for 10 rm of work ,minimum weight 13.5 kg for 10 rm of work including dismantling of existing concertina coil complete all as specifed and directed by engr-in-charge. (note:- the actual weight of concertina coil brought by the contractor at site shall be ascertained by boo as ordered by ge). 78.00 s&f for concertina coil with punched tape of 900 mm dia (when stretched), centre core wire of minimum 2.5 mm dia of mild steel wire conforming to is 280-2006 with galvanised coating of steel concertina coil as per requirements laid down for medium coated wire in is : 4826 hot dipped galvainsed coating of round steel wires. conretina coil shall be fixed in diamond shape with the help of dovetail two handle and spikes shall be fixed at both end of coil,minimum straight length of the wire 180 rm for 10 rm of work ,minimum weight 16.5 kg for 10 rm of work including dismantling of existing concertina coil complete all as specifed and directed by engr-in-charge. (note:- the actual weight of concertina coil brought by the contractor at site shall be ascertained by boo as ordered by ge). 79.00 dismantling of fencing wire, barbed wire any type and description complete all as specified and as directed. 80.00 supply and fixing galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2 mm dia barbed of 75mm spacing and straining and fixing to any type of standard rail, straining bolt including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc as directed (each line wire to be measured) complete all as specified and as directed. 81.00 m&l for cuting holes in brick walls exc half brick but n.exc one brick, built in cement mortar for fixing holdfasts in jambs of existing opening and making good complete all as specified and as directed. 82.00 m&l pcc (1:3:6) type c1 (using 20 mm graded stone aggregates) as in hold fast block including necessary form work complete all as specified and as directed. 83.00 s&f mild steel work framed such as grill, gratings, etc with ends of bars shouldered and /or riveted, or forged into spikes, framed guard bars barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to fe.290.gde-e-165. complete as specified and as directed. 84.00 dismantling of fencing wire mesh, any type of any description complete as specified and as directed. 85.00 fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete as specified and as directed. 86.00 supply only chain link ms galvanised fencing, 4mm dia gi wire mesh size 100mm x 100mm complete as specified and as directed. 87.00 s&f mild steel screw bolts 12 mm dia (machine made) with hexagonal heads at one end and screwed other end to be fitted with washers (02 nos.) and one hexagonal nut, length of bolt exe 5 cm and n exe 10 cm complete as specified and as directed. 88.00 s&f mild steel fabricated round bars 10mm dia as in horizontal bars for chain link fencing incl necessary hooking at ends all as complete as specified and as directed. 89.00 excavation in post hole (or similar holes) each n.exc 0.50 cum getting out returning, filling in and ramming earth around in layers n. exc 25cm watering and removed surplus soil to a distance n. exc 50m and making good surface in soft/loose soil complete as specified and as directed. 90.00 supply and fixing in repairs, pre cast cement concrete jallies, 35 mm thick, type b0 1:2:4 (using 12.5 mm graded crushed stone aggregate) including wire fabric set and jointed in cement mortar (1:4) complete as specified and as directed. 91.00 s&f in repair aluminium composit panel (acp) sheet with 1x1.5 aluminium tube over the framed/ beam of gates. acp shall meet under mentioned technical requirements:- (i) coating on front : high quality polymer resin.(ii) core : fr core (fire retardant)(iii) thickness : 4mm(0.5 mm+3.0mm+0.5mm) (iv) weight : 7.50kg/sqm(v) width: 1200mm(vi) length: 1200 to 2400mm(vii) structure: aluminium panel are protective film,clear coating pvdf,primer coating,antirust layer,aluminium skin and polyethylene.(viii) temp resistance : between -50c to +80c(note:- the quoted rate is deemded to be included necessaryy scaffolding required and joint sealing) 92.00 s & f in repair 12mm thick toughened glass fixed with double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminum alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other party made of mild steel heavy duty and stainless steel handle purpose made on both side with locking machanism and with necessary stopper etc complete all as specified and as directed. 93.00 demolition and breaking up drain pipe 75/100mm dia ( salt glazed ware, ac or pvc) of any type complete all as specified and as directed. 94.00 s&f 75 mm dia pvc (swr) pipes single socketed in any length with rubber ring joints fixed to walls including suitable clamps after every one meter of interval complete all as specified and as directed. 95.00 s&f 110 mm dia pvc (swr) pipes single socketed in any length with rubber ring joints fixed to walls including suitable clamps after every one meter of interval complete all as specified and as directed. 96.00 s&f in repairs pvc(swr) bends any radius, 75 mm bore complete all as specified and as directed. 97.00 s&f in repairs pvc(swr) bends any radius, 110 mm bore complete all as specified and as directed. 98.00 hacking out old broken glass (any thickness, size, quality or description) from wooden frames or steel, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed. 99.00 s&f sheet glass 4mm thick ordinary quality and glazing with oil putty or rubeer bedding in square n. exc 0.5 sqm in each pane complete all as specified and as directed. 100.00 s&f in repairs of sink with drainage board, made out of stainless steel 1mm thick, kitchen or laboratory with plugs, washes and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever bracket and connecting union to pipe over all size (915x460)mm with bowl size (410x330x160)mm complete all as specified and as directed. 101.00 s&f in repair brass chromium plated shower rose,125 mm size fixed to 15 mm bore iron pipe complete all as specified and as directed. 102.00 s&f in repair water closet vitreous china squatting pan, orissa pattern size (580x440)mm white with integral foot rests (excluding flushing cistern and flush pipe) and including with p or s trap complete including provison of lime concrete bedding fixed in repair complete all as specified and as directed. 103.00 m&l for gunniting work to rcc work in column, flooring, side walls, beam, slab, etc by removing loose concrete cover etc, cleaning of surface with wire brush and applying epoxy paint to rusted reinforcement and s&f welded wire mesh fabric or wire net less than 95 x 95x 3 mm tied to existing reinforcement with nails,adhesive plaster grade for concrete and providing gunniting pressure 2.0/2.5kg/sqm with admixture 1 part of cement and 3.5 part of sand with average thickness 40 mm and making the surface even including 15mm thick plastering in cm 1:4 on brick or concrete surfaces including finishing the surfaces even and smooth, without using extra cement including necessary form work to be carried out,complete all as specified.(note.- wherever reinforcement required shall be measured and paid seperately) 4. structural steel steel authority of india limited (sail) brand: sail / rashtriya ispat nigam limited (rinl) brand: rinl / tata iron & steel company (tisco, or tata steel) brand: tata / m/sjindal steels and power ltd. brand: jindal 5 factory made paneled/ glazed /gauged door shutters m/s mp wood product indore, m/s jain doors pvt ltd sonipat, goyal industiral corporation new delhi, shri krishna industries, panchkula, 6 factory made flush door shutters m/s green ply industries, m/s centuary ply, m/s dura ply. mysore chip board, archid, swastik ply wood, m/s jain doors pvt ltd 7 pvc door frame/shutters sintex, rajshri plastiwood ltd, m/s dura plast extraction pvt ltd, m/s fenesta, ecocell,accucell 8 frp door frame and shutter selected products co., sintex, rajshri plastiwood ltd, accure polytec pvt ltd ,ecocell, fiberways 9 upvc window/doors fenesta, ncl veka, madhu industries, h2o solutions, yashpoly,accucel, okotech, aseco (m/s ashish industries) 10 iron mongery mowjee, m/s kitch architectural product pvt ltd, rs industries. 11 hydraulic door closer everest, universal, godrej 12 particle board(veneered & unveneered laminated)/ block board kitply, nova pan industries, new delhi, m/s green ply industries ltd, archid ply, bhutan board, dura board mysore chip board ltd 13 plywood for general purposes dura ply, archid ply, bhutan board,archid board, century, durian, mysore chip board ltd 14 decorative laminates archid lam, sunmica, merino, lam, mysore chip board,greelam 15 terrazzo tiles ntc, nitco, eurocon, duracrete 16 glazed ceramic/non skid wall/floor tiles kajaira, johnson, agl, qutone , somany, nitco, orient bell ,vitero, sunhearrt ceramik, varmora 17 vitrified tiles (polished, unpolished & glazed, normal/ anti skid) kajaira, johnson, agl, qutone , somany, nitco, orient bell,vitero,sunhearrt ceramik, varmora 18 hdpe storage water tanks sintex, supreme,plasto,polycon 19 sanitary appliances /fittings(chinaware) hindware,parryware,cera,jaquar, kohler, prayag aproyale,somany 20 water closet seats and cover (solid bakelite) thermostat moulded toilet seat cover parryware, jaquar, prayag somani,commander,cera,neycer 21 pvc flushing cisterns hindware, commander, parryware, cera ,jaquar, johnson pedar, neycer 22 stainless steel kitchen sink with or without draining board, plate rack nirali,cera,diamond,jainco,shakti prayag, (silver shine) m/s bluestar sanitary industries 23 ball valves (horzontal plunger type) dripless faucets india, flowjet , ball valves inida. 24 shower roses chromium plated (swivel type) gem,jaquar, jal 25 bath room fancy fittings jaquar,gem,marc, jalangi 26 bib taps and stop taps (cp),pillar tap, fancy fittings jaquar, parko, gem, marc 27 bathroom cabinets jaquar, cera, commander, parryware .... more in document
  • View Tender
  • Document
  • Bid Support
4 Power
image image
State Government
TRN :49057999 |  23 May, 2025
Tender Value : 0
 Ghaziabad - Uttar Pradesh
Tender for tender for construction of civil works for increasing capacity from (1x500 plus 2x315 mva) to (2x500 plus 1x315 mva) at 400 k.v. sub-station-ist muradnagar ghaziabad. - earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) all kinds of soil including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by engineer-in-charge. 2 excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also includingramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all 3 providing and laying in position cement concrete of specified grade 1:4:8 (1 cement : 4 coarse sand (zone-iii) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)excluding the cost of centering and shuttering - all work up to plinth level : 4 providing and laying in position cement concrete of specified grade 1:5:10 (1 cement : 5 coarse sand (zone-iii) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)excluding the cost of centering and shuttering - all work up to plinth level : 5 providing and laying in position cement concrete of specified grade1:1½:3 (1 cement: 1½ coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - all work up to plinth level : 6 providing and laying in position specified grade of reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources), excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level : 7 centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete 8 centering and shuttering including strutting, propping etc. and removal of form for walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 9 centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platform 10 centering and shuttering including strutting, propping etc. and removal of form for columns, pillars, piers, abutments, posts and struts. 11 providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 12 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. thermo-mechanically treated bars of grade fe-500d or more. 13 brick work in foundation & plinth with old dismantled bricks (supplied by department free of cost) and coarse sand mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,t&p etc complete . 14 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand). 15 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in cement mortar 1:6 (1 cement : 6 coarse sand). 16 dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with jamuna sand, with common burnt clay non modular bricks 17 supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer-in-charge . 18 structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 19 mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record, racks roof workgates etc. wrought to required form including holes rivetting or welding where necessary and also fixingin proper position and alignment but when steel is to be provided by the department . 20 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand). 21 extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. 22 extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 23 neat cement punning 24 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 25 demolishing cement concrete (nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)) manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 26 demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 27 dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. 28 demolishing r.c.c. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. 29 dismantling of existing pale / security / chain link fencing including post and stacking properly as per direction of the engineer - in - charge. including all labour and t&p etc. required for proper completion of the work 30 disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 31 supply of 25 mm. dia m.s. anchor bolts (conforming to is 266)500 mm. long with base plate (50x50x6mm) welded with anchor boltsincluding its threading upto a length of 10cm. and also supplyof a pair of galvanized standard nuts with threading including supply of 5 mm thick washer and cost of labour, material & t&p for proper completion of work 32 fixing and grouting 25 mmand below dia m.s. anchor bolt in proper alignment level and setout with the help of a template including supply of all labour t&p etc. reqd. for proper completion of the work. (labour rates only) . 33 grouting of 90/105 lbs m.s. railincluding cost of all materials,labour & t&p for fixing of rail in proper alignment, leveland position in transformer plinth foundation etc. as perdirection of eng i/c. (rail to be supplied by thedept.)(labour rates only) . 34 s/f in position 105 lbs m.s. rail for transformer plinth including cost of all labour, material and t&p etc. required for proper completion of the work. 35 fixing and grouting of trench edging in proper level and alignment including cost of all labour, and t&p etc. required for proper completion of the work but excluding cost of c.c. (labour rates only) . 36 fixing of template in position level and alignment for groutingof anchor bolt in auxiliary gantry (labour rate only). 37 fixing of cable trench racks in proper position and alignment including cost of all labour, material and t&petc. required for proper completion of the work (labour rate only). 38 fabrication of template forauxiliary foundation including cost of all labour, and t&p etc. required for proper completion of the work. steel shall be arranged by contractor free of cost. this template shall be property of contractor.(labour rate only). 39 4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm gradedapproved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement andmarble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels ifany and giving them a uniform finish including supply of all materials, labour and t&p etc, required forproper completion of the work. without base cc 40 placing of trench cover of all size in proper position including transportation from different places withinthe s/s area including all labour, t&p etc. required for proper completion of the work as per direction ofengineer - in - charge. 41 preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. 42 providing and laying swr, pvc ( finolex or equivalent ) pipe including cost of excavation, c.c etc including its jointing and connection, all materials, labour and t&p etc. required for proper completion of the work (110mm dia pipe) 43 providing and laying design mix cement concrete of m-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy m.s. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of engineer-incharge (item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).cement concrete manufactured in automatic batching plant (rmc plant) i/c transportation to site in transit mixer 44 providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood pre-laminated one side decorative lamination and other side balancing lamination grade i, type ii, is : 12823 marked, including priming coat on unexposed arrangement and screws etc. complete : (12mm thick partical board) 45 hiring of beldar(labour).
  • View Tender
  • Document
  • Bid Support
5 Security Services
image image
Central Government/Public Sector
TRN :49068734 |  28 May, 2025
Tender Value : 40.00 Lacs
 Bikaner - Rajasthan
Tender for tender for certain repair to buildings of wsa at af stn nal; 1 demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for allas specified and directed. 2 m&l for cement concrete type d2 (1:4:8) ( 40 mm graded crushed stone aggreagte) as filling and mass concretecomplete all as specified and directed. 3 m&l for laying 100mm thick cement concrete type b-1(1:2:4) ( 20 mm graded crushed stone agg)as in floor and paving surfaces all as specified and directed. 4 demolition of brick workor stone/boulders masonary, built in cement mortar or cement lime mortar including all quions, arches, pillars etc. and rubbish materials remove from site all as specified and directed 5 m&l for brick work with sub class b bricks (old size) straight or curved on plan exc 6m mean radius built in cm (1:6) complete all as specified and directed by engr-in-charge. 6 taking down cement plaster of any description on brick/stone walll incl raking out joints hacking for keyscrubbing down water all as speicifed. 7 m&l for rendering 15 mm thickin cement plaster (1:6) on fair faces of brick/concrete surface, finishing even and smooth w/o using extra cement etc. 8 m&l for rendering 15mm thick in cement mortar (1:4) on brick or concrete wall surface finished even and smooth without using extra cement. 9 m&l for preparing newly plastered wall surfaces and applying two coats of weather proof exterior emulsion over and including one coat of primer complete all as specified and directed by engr-in-charge. 10 m&l for preparation of newly plastered surfaces of wallsand applying two coats of oil bound distemper over and including a coat of primer incl etc. complete all as specified and as directed. 11 m&l for preparation of old decorated surfaces of walls (plastered or un plastered) including cornices, pilaster etc by brooming down with steel wire brushing, scrapping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc including filling the depressions with cement based wall care putty and applying one coat of oil bound distemper complete all as specified and directed. 12 m&l for preparation of old painted surface ofwall surface and applying one coat ofweather proof exterior emulsion in camouflage pattern to match the existing pattern complete all as specified and diricted by engineer-in-chare. 13 rough excavation not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified . 14 removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed at a level n.exc 1.5m above starting point complete all as specified and directed by engr-in-charge. 15 forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base complete all as specified and directed by engr-in-charge. 16 allas per item no-15 (here-in-before) but 1.5m to 3m height from base completeall as specified and directed by engineer-in-charge. 17 allas per item no-15 (here-in-before) but 3m to 4.5m height from base completeall as specified and directed by engineer-in-charge. 18 allas per item no-15 (here-in-before) but 4.5m and above height from base completeall as specified and directed by engineer-in-charge. 19 dismantling posts or struts in natural ground (wood, steel or r.c.c.) any section, including taking out embedded portion and making good disturbed groundcomplete all as specified and directed by engr -in-charge. 20 excavation in post holes(or similar holes) each in not exc. 0.50 cum getting out returning,filling in an ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm watering and removing surplus soil out of defence land and making good surface all as specified & directed. 21 m&l for pcc(1:3:6) type c2 (40mm graded crushed stone aggregate) filling in post holes, foundation,and other similar work complete all as specified and as directed. 22 s & f hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to fe 410-0 or fe 310-0 23 dismantling fencing wire mesh, any type etc, complete all as specified and as directed. 24 s&f in repair galvanised 2 strand , steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixingto any type of standard railsstraining bolts, including securing ortyping at crossingswith andprovision of galvasnised mild steel wire, staples or steel pins, etc as directed (each line wire to be measured), complete all as specified and as directed. 25 fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire 26 supply only galvanised mild steel chain link fencing, size wire and mesh as approved complete all as specified and directed.note:- the payment for chain link fencing shall be made on the basis of weight of chain link fencing per square metre ascertained by a board of officer convened by ge, by getting minimum 3 samples of each lot . 27 m&l for preparation of new steel surfaces of any description, not otherwise described over 10cm width or girth and applied two coats of synthetic enamel paint over and including a coat of red oxide zinc chrome primer complete all as specified and directed by engr -in-charge. 28 dismantling timber scantlings 40 sq. cm and over in section, in any position in framed section etc., complete all as specified and as directed. 29 dismantling of wrought iron or mild steel work of any description not ohterwise provided for complete all as specified and directed. 30 m&l for ms work in roof trusses (framed), trussed, purlins, crane gantries, rails, posts and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.including special shaped washer etc. complete and including all necessary drilling or cutting holes in brick/ concrete surfaces and making good by pcc and cement plaster, welding work, bolting or reveting/fastening with fastner etc and similar work conforming to fe-290 gde e-165 complete and all as specified 31 s&f ms plain plates, square cut, with riveted, bolted or welded attachment fe-410-w (gde-e-250) quality a as specifed 32 s&f mild steel screw bolts (machine made) with hexabonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n.exc 5cm long, diameter of neck in 5 to 10mm. 33 dismantling asbestos cement (corrugated,semicorrugated, etc.) sheets in roofcoverings including ridges complete all as specified & directed. 34 s & f pre- painted galvalume aluminum zinc coating gi based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. 35 dismantling plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof covering etc. 36 s & f 1mm thic plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters,(joints should be water tight) drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 etc. 37 supply and laid in repairs 110mm bore pvc (swr) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors etc. 38 s& f in repairs pvc (swr) bends for 110mm bore pipe etc. 39 taking up or down 15 mm dia steel tubing & connections or removal to store etc. 40 s & f 15mm bore of tube medium grade galvanized with and including all fittings & fixed complete to walls & ceiling or laid in floors complete all as specified and directed. 41 dismantling water tanks any type of capacityexc 1000 but n.exc 2000 liters 42 dismantling water tanks any type of capacityexc 250 but not exc 500ltr 43 s&f 1000 liter capacity rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) tripple layered white, hoisted and fixed in position with and including 20 mm bore ball valves high pressure of ptmt with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and directed. 44 s&f 500 liter capacity rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) tripple layered white, hoisted and fixed in position with and including 20 mm bore ball valves high pressure of ptmt with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and directed. 45 s&f in repair 15mm bib taps quarter turn, cast copper alloy , with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed etc. 46 taking down door shutters of any description exc 2sqm complete all as specified. 47 taking down old wooden doors (single/double shutter ) of exc 4sqm n.exc 6sqm any position with complete accessories including chowkhat or frame all as specified and directed by eic. 48 taking down chowkhats or frames or ventilator not exc. 1.5 sq. m each etc. 49 s & f framed work as in doors, gates and ventilators of angle or other sectionfe-410 w (gde e-250) quality a with gusset plates, ms plain black sheet for door, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. 50 s & f expanded metal, weight not exc 4kg per sqm cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members 51 s & f mild steel flat iron as in hold fast 400mm long embeded in pcc block with splitted ends and in braces in diagonal hand made sliding bolts, clamp hooks and similar worklike banks, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; largehasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to fe410-0 or fe 310-0 52 m & l for pcc (1:2:4)type b1 (20mm graded stone aggregate )asin lintels upto 1..5 m clear span, cills, hold fast for door, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directing 53 s&f 35 mm thick 2nd class hardwood, plain, framed, factory made panelled shutters (any number of panels), in with panels of timber flat on both sides (feather edged), of 12 mm bwp commercial ply with commercial veneering on both faces; supplied and fitted to chowkats 54 material and labour for preparation of new wood surfaces of any description not other described over 10cm width or girth and applying twocoats of synthetic enamel paintover and including a coat of pink primer complete all as specified and directed. 55 supply and fixing in repair mild steel butt hinges medium weight, cold rolled, 100mm, isi marked, fixed with stainless steel screws complete all as specified and directed. 56 supply and fixing 150mm aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. 57 supply and fixing 150 mm size extruded aluminium alloy handels fabricated type, anodised fixed with stainless steel screws complete all as specified and directed. 58 supply and fixing 300mm aluminium alloy, anodised sliding door bolt with hasp staple (bolt type) fixing clips of sheet, cast or extruded setions and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed with stainless steel screws complete all as specified and directed. 59 m&l for providing post construction anti termite treatment to soil under existing floors using chemicalemulsion @ one litre per hole, 300 mm apart along the junction of floor and wall including drilling 12 mm dia holes and plugging with cement sand mortar (1:2) using pigment wherever required, to match the existing floor surfaces complete all as specified and directed.note :-any crack which is developed during execution of att in the floor shall be repaired to match the surface.the cost of this aspect shall deemed to be included in the rates quoted by the contractor 60 m&l for providing post construction anti termite treatment by specified firm along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre i.e. holes @300mm interval including drilling and plugging holes etc in apron/plinth protection and making good the surfaces to match complete all as specified and directed. 61 m&l for providing post construction anti termite treatment by specified firm to voids in masonry using chemical @ one litre per holes at 300 mm intervals by drilling holes at downward angle of 45 degree and replugging them with cement mortar 1:2 to match the existing surface complete all as specified and directed. 62 s&f in repair vitreous china wash down water closet pan pedestal pattern ( type white including pvc seat cover , connection to waste pipe and flushing pipe complete etc. 63 s & f in repair 10 ltr capacity pvc valveless syphonic action type flushing cistern low level white with inlet ball valve and brackets,float and handle, l-bend complete all as specified and directed 64 s&f in repairs vitreous china wash basin, white, flat back, size 580x450mm excluding taps waste, chain and plug and porcelain stopper but including bracket complete all as specified and directed 65 s & fvitreous china urinals, bowl type (back or corner wall type),complete including providing and fixing plugs, bedding urinal against wall in cement mortar1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets,flush pipe, grating and union for discharge pipe.fixed in repairs complete all as specified and directed. 66 s & f urinal spreader of ptmt any colour for fixing with 15 mm dia pipe. (minimum weight 60gms) 67 s & f health faucet (abs body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and abs wall hook including making connections and fixed in position complete in all respect as specified. 68 s & f in repair long body stop valve 15mm bore(quarter turn) fancy type chromium plated screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions. 69 s&f in repairs 15mm bore pvc connection pipe 450mm long with ptmt nuts at both ends etc.
  • View Tender
  • Document
  • Bid Support
6 Security Services
image image
Central Government/Public Sector
TRN :48475497 |  17 May, 2025
Tender Value : 37.70 Crore
 Jaipur - Rajasthan
Tender for tender for provision of klp (ph-ii of two phases) for engr regt at jaipur mil stn; 1 lump sum price worked out by the contractor for building worksas listed in schedule ‘a’ part-i representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 2 lump sum price worked out by the contractor for internal water supply as listed in schedule ‘a’ part-ii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 3 lump sum price worked out by the contractor for internal electrificationas listed in schedule ‘a’ part-iii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 4 lump sum price worked out by the contractor for road, path and culvertas listed in schedule ‘a’ part-iv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 5 lump sum price worked out by the contractor for sewage disposalas listed in schedule ‘a’ part-v representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 6 lump sum price worked out by the contractor for area drainage as listed in schedule ‘a’ part-vi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 7 lump sum price worked out by the contractor for rain water harwestingas listed in schedule ‘a’ part-vii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes 8 lump sum price worked out by the contractor for external water supplyas listed in schedule ‘a’ part-viii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the mes 9 lump sum price worked out by the contractor for external electrificationas listed in schedule ‘a’ part-ix representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the mes 10 lump sum price worked out by the contractor for parade ground of size 137 m x 91 m, footbal/hockey 02 nos, basketball courts 02 nos, volley ball courts 02 nos, hardstanding & badminton court 01 noas listed in schedule ‘a’ part-x representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the mes 11 lump sum price worked out by the contractor for compound wall, chain link fencing and gate as listed in schedule ‘a’ part-xi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 12 lump sum price worked out by the contractor for hot water supplyas listed in schedule ‘a’ part-xii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 13 lump sum price worked out by the contractor for refrigeration and cold water supplyas listed in schedule ‘a’ part-xiii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 14 lump sum price worked out by the contractor for site clearance, site developmentand earth workas listed in schedule ‘a’ part-xiv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 15 lump sum price worked out by the contractor for addn/altn of existing buildings & structures (b/r)as listed in schedule ‘a’ part-xv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 16 lump sum price worked out by the contractor for addn/altn of existing buildings & structures (e/m)as listed in schedule ‘a’ part-xvi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 17 lump sum price worked out by the contractor for demolition of buildings & shedsas listed in schedule ‘a’ part-xvii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes 18 sch a part-xviii misc items (to be quoted by contractor) notes:(i) this schedule is not pre-priced by mes and the pre-priced rate indicated as rs 0.00 under column 5 signifies this fact only. (ii) excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under sch a part-xiv (site clearance, site developmentand earth work schedule). 19 pop ealse ceiling for sch a part i building work (officers mess & adm block)m&lforpop false ceilingof approveddesignconsisting of 10mm thick plaster of paris ceiling (gyspsum anhydrous) board including gi frame work for 12mm seamless ceiling comprising of gi perimeter channel of 0.55 mm thick with two unequal flange of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre intermediate channel 0.5 mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900 mm centre to centre with gi cleat and tee, expansion fasteners with and including ceiling section (not exc 1.2m length)of 0.55mm thickness having curved web of 50mm and flange of 26mm each with clips of 10.5mm fixed to intermediate channel with connectingclips across the intermediate channel of 457 mm centre to centre complete. 20 internal water supply (sch a part-ii) s & f 15mm bore angle valve/cock cast copper alloy fancy type screwed down high pressure with cructh or butterfly handle screwed both ends for iron pipe or brass ferrule fixed. make - cera-f1012201, jaquar - ari- chr-39053, kohler - k-80154in-4-cp 21 s & f wall mixer/diverter with diverter plate of bathroom 3 in 1 system with provision for both hand & over head shower with 115mm long bend pipe ( for mixer) connecting legs & wall flangs complete all as specified. make: cera-f1022403, jaquar-flr-chr-5281n, hindware-flora f280022 22 s & f chromium plated brass bath tub spout with wall flange(fancy type) suitable for 15mm bore pipe complete all as specified and directed. make- cera-f1012661, jaquar-spj-chr-429, hindware-f-520009 23 internal electrification (sch a part-iii)supply and fixing sp 63 amp rating, 240v, 10 ka c curve miniature circuit breaker (mcb) of following poles and current carrying capacity in the mcb db complete with connection testing and commissioning complete all as specified and as directed. 24 supply and fix tv coaxial,1 module socket complete all as specified and as directed. 25 s&f telephone socket(jack type) ,1 module rj11 with shutter complete all as specified and as directed. 26 m&l for electrolyte grade solid annealed copper conductor,jelly field,aluminium foiled and aluminium wire braided, rg59 (foam). cat part no. whojttkarg59make- havells or equivalent in as mentioned in appx b of particular specification 27 m&l for pvc insulated telephone cables for indoor applications confirming to technical specification g/wir06/02 cat part no.whttatea1p40 make-havells or equivalent in as mentioned in appx b of particular specification 28 s & f for highly efficient led bulbs, 9 watt complete all as specified and directed. make bajaj/havells/hpl 29 s & f blanking plate complete all as specified and directed. 30 s & f of sheet metal enclosure distribution board vtpn ,4 way, 415 volt, double door powder coated, protection class ip-54, isolated neutral bar, mechanical impact strength ik 09 suitable for mounting mcb & mccb dbs confirming to is-13032, is-8632,bs5484 with min 200 amp raiting copper bus bar and grouting, fixing on wall with nut boldts washers proper with pcc works complete all as specified and directed 31 rain water harwesting(sch a part-vii)borewell for rain water harvesting all as specified and shown on drg : (a) provision of trail bore by drilling with reverse rotary system550mm bore upto 52 m depth incl all works pertaining to boring complete in all respect in aluvium soil/ strata incl hard stone / boulder etc.(b)m&l for 150mm bore cpvc pipe assembly jointing, lowering in any position upto the reqd depth below given level incl jointing the pipe by solvent & screwing 04 nos screws in each joint complete all as directed.(c) ditto as item (b) above but slotted pipe(d) m& l for packing with pea gravel of 4.6 mm to 8mm size of approved quality as ordered to pack arround the casing / slooted pipe in borewell all as directed.(e) m&l 25 mm bore perforated cpvc pipe 52 mtr long for vent pipe 32 external water supply(sch a part-viii). m& l for cutting of existing pipeline of 100/150/80 mm dia for taking branch connection alongwith insertion of di tee and connecting material such as joint, nut bolts, etc all as required at site. 33 m&l for construction ofbrick stone masonary valve pit / chamber of size 900 mm x 600 mm x 1000 mm (internal dimensions) all as shown in drawing no td-573, including necessary excavation and earth work, pcc, plaster in cm 1:6 on inside and outside (above ground), ms angle iron 40 x 40x6.0 mm thick complete all as specified and directed and shown on drawings. 34 all as per item no 33.00 but chamber size 450 mm x 450 mm x 600 mm (internal dimensions) complete all as specified and directed 35 supply and fix stop valves 63mm dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed 36 external electrification . (sch a part-ix)supply and fixing led street light fitting 36 wattefficacy greater than 100 lumen/watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 65/66 protection complete all as specified and directed. make : phillips, cat no brp046 led 36 cw mr s1 psu gr 9405 or equivalent in as mentioned in appx b of particular specification 37 supply and fixing poly carbonatejunction box , weather and vermin proof of size 250x250x160 including provn of 4 nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators,including one no. mcb sp 6 amps for light control,drilling of holes.provn of suitable size of gi nuts, bolts, double washer and fi clamps ofsuitable sizefor taking connections and fixing on lt steel tubular poles complete with locking arrangement complete all as specified and directed. 38 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-(main ltp no-01 ) 39 incoming :-(a) mccb 4 pole 320 amp thermal magnetic protection type, 36kamake : legrand, cat no - 4220-06, dpx3 630- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc.(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100outgoing :-(a) mccb 3 pole 160amps thermal magnetic protection type, 36 ka, make : legrand, cat no - 4200-87, dpx 160- 01 nob) mccb 3 pole 200amps thermal magnetic protection type, 36 ka, make : legrand, cat no - 4202-08, dpx 250- 01 no (c) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(d) analog time switch, make- legrand, cat no 4127-80 for sl control 40 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -4. 41 incoming:- (a) mccb 4 pole 160 amps thermal magnetic protection type, 25 ka, make : legrand, cat no - 4200-57, dpx 160- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going:- (a) mccb 3 pole 63 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-43 - 02 no (single offr accn + ltp - 08)(b) mccb 3 pole 40 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-42 - 02 no ( servant qtr + sl)(c) mccb 3 pole 125 a thermal magnetic protection type, 25 ka dpx3 160, legrand, cat no 4200-06 - 01 (offr mess)(d) mcb dp 16amp - 01 no ( garage)(e) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(f) analog time switch, make- legrand, cat no 4127-80 for sl control 42 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp - 8incoming(a) mccb 4 pole 63 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-13 - 01 no 43 (b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 10 no 44 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -3. 45 incoming(a) mccb 4 pole 200 amps thermal magnetic protection type, 25 ka, make : legrand, cat no - 4202-18, dpx 250- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mccb 3 pole 100 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-45 - 01 no(ltp - 06)(b) mccb 3 pole 160 a thermal magnetic protection type, 25 ka dpx3 160, legrand, cat no 4200-47 - 01 (adm bldg)(c) mccb 3 pole 40 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-02 - 02 no (saa stores + old guard house)(d) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 03 no(e) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider (f) analog time switch, make- legrand, cat no 4127-80 for sl control 46 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -6 47 incoming(a) mccb 4 pole 100 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-55 - 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out goingm(a) mccb 3 pole 63 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-43 - 01 no (b) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 05 no 48 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -7 49 incoming(a) mccb 4 pole 63 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-53 - 01 no (b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mccb 3 pole 40 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-02 - 02 no ( bch + mt office)(b) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 13 no (garage) (c) mcb 3 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-55 - 02 no (car washing + longe wala gate) 50 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:- (main ltp no-02 ) 51 incoming (a) mccb 4 pole 400 amp thermal magnetic protection type, 36kamake : legrand, cat no - 4220-07, dpx3 630- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100outgoing (a) mccb 3 pole 200amps thermal magnetic protection type, 36 ka, make : legrand, cat no - 4202-08, dpx 250- 01 no(ltp -02)(b) mccb 3 pole 160amps thermal magnetic protection type, 36 ka, make : legrand, cat no - 4200-87, dpx 160- 01 no (ltp - 01)(c) mccb 3 pole 40 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-42 - 01 no(ltp - 5)(d) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(e) analog time switch, make- legrand, cat no 4127-80 for sl control 52 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -1 53 incoming(a) mccb 4 pole 160amps thermal magnetic protection type, 25 ka, make : legrand, cat no - 4200-57, dpx3 160- 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mccb 3 pole 40 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-42 - 01 no ( ltp -5)(b) mccb 3 pole 25 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-01 - 02 no ( fwc + ori )(c) mccb 3 pole 16 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-00 - 02 no ( religious hall + unit shop)(d) mccb 3 pole 80 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-44 - 01 no ( trademen shop)(e) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider (f) analog time switch, make- legrand, cat no 4127-80 for sl control 54 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated over two coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -5incoming(a) mccb 4 pole 40 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-12 - 01 no(b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100 55 out going(a) mccb 3 pole 16 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-00 - 01 no ( drying & ironing)(b) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 4 no (car shed - 01 no + scooter shed - 01 no + dhobi ghat - 02 nos) (c) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(d) analog time switch, make- legrand, cat no 4127-80 for sl control 56 supply install,testing and commissioning lt paneloutdoortype, dust and vermin proof totally enclosed floor mounted factory made, kiosk type with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. the construction of panel board shall be dust, vermin proof, ip 54 standard double shutter gears front and rear frame work and 3.15 mm thick ms sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in floor the panel suitable for 415 volts, 50 c/s 3 phase and nutral system 57 and shall be completed with aluminium bus bar of size ( current ratingnot less than 1.5 times of incoming mccb ) with bus bar chamber,internal wiring with suitable size of pvc insulated copper cable comprising of following accessories:-. for ltp -2incoming(a) mccb 4 pole 200amps thermal magnetic protection type, 25 ka, make : legrand, cat no - 4202-18, dpx3 250- 01 no (b) indicating lamp - 3 nos , make : schneider cat no xa2evq1lc to 8lc(c) led multifunctional meter (make: l&t) -01 no cat no : dm6100out going(a) mccb 3 pole 25 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-41 - 02 no (s/l jco)(b) mccb 3 pole 16 amp thermal magnetic protection type, 16 ka dpx3 160 legrand, cat no 4200-00 - 04 no ( s/l 01 jco + engr store + def store + old bldg)(c) mccb 3 pole 80 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-44 - 01 no ( jcos mess)(d) mccb 3 pole 63 amp thermal magnetic protection type, 25 ka dpx3 160 legrand, cat no 4200-43 - 01 no (mi room)(e) mcb 2 pole 16 amp, ccurve, 10 ka, legrand, cat no 4086-33 - 4 nos (car shed - 01 no + scooter shed - 01 no + garage for amb - 01 no +car shed/scooter shed - 01 no ) (f) 3 pole power contactor, frame - 1, ac rating 12 a cat no - lc1e1210 make - schneider(g) analog time switch, make- legrand, cat no 4127-80 for sl control 58 taking down old cable xlpe insulated ,screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor off sizes from existing site 59 dismentling street light bracket off sizes complete all as specified and directed 60 dismantling and taking down lt feeder pillar box off size complete all as specified and directed 61 dismantling and taking down outdoor distribution box off size complete all as specified and directed 62 dismantling and taking down transformers 160 kva to 500 kva and deposit to mes store yard or keeping in safe custody for re-installation complete all as specified and directed 63 parade ground of size 137 m x 91 m, footbal/hockey 02 nos, basketball courts 02 nos, volley ball courts 02 nos, hardstanding & badminton court 01 no (sch a part-x (synthetic floor / mat for basket ball & volley ball courts) m & l for antifungal, anti microbial and u/v resistant comprising of pvc wear resisting coat thickness of 3.5mm to 8mm over of fiber-glass reinforced layer with pvc foaming buffer layer of thickness 4.5mm for good performance in rebounding & absorbing shock complete all as specified and directed 64 refrigeration and cold water supply(sch a part -xiii)supply and fix refrigerator, electric driven (single phase),direct cool single door 5 star refrigeratorwith base drawer with smart inverter compressorcapacitynot less than 185 litrescomplete all as specified and directed 65 supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of ± 2.5% and of capacity not less than 2.0kva complete all as specified and directed 66 supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 cum per hour (or nearest size) steel body complete all as specified and directed 67 addn/altn of existing buildings & structures (b/r) : schedule a part -xvm & l for providing 5-7mm thick screed bed ofchemical adhresive of approved make for laying floor finishes i,e floor tile etc. complete all as specified and directed. 68 taking down existing water proofing roof treatment of any description cleaning the surface by hacking to received plaster complete all as specified and removing demolised material outside mod land. 69 s & f fibre reinforced uv resistant elastomeric liquid applied waterproofing & heat reflective coating with acrylic polymers and polyester/glass fibres after scraping and properly cleaning the surface to remove loose perticles with wire brushes complete or as directed water proofing treatment shall be in three coats over a coat of primer and as per manufacturers instructions complete all as specified and directed. 70 m & l for retrieving vegetation growth/plants from wall roofs, chajja upto double storey height incl taking out deep roots and pouring hcl acid and making good the distrubance surfaces with cm 1:4 incl all means required at site complete all as specified and directed 71 addn/altn of existing buildings & structures (e/m) : schedule a part -xvitaking down of existing unsv sub main wiring any size incl pvc/steel conduit complete and making good to disturbed surfaces complete all as specified and directed. 72 taking down of existing unsv dbs any size complete all as specified and directed 73 supply & fixing of mcbs, 10 ka rupturing capacity, is-8828 marked,dp 10 ampsand fixing in dbs complete all as specified and directed(note:- dbs shall be measured and paid separately in respective item) 74 all as per items no 63.00 butdp 20 amps 75 all as per items no no 63.00 but 4p 25 amps 76 all as per items no no 63.00 but sp 6 amps 77 all as per items no no 63.00 but sp 10 amps 78 all as per items no no 63.00 but sp 20 amps 79 demolition of buildings & sheds : schedule a part -xvii taking down carefully by carefully unscrewing serviceable/unserviceable dbs,any sizes 415 volt complete with bus bar and rails for easy mounting of mcbs complete with from boards and disconnecting from incoming and outgoing complete all as specified and directed 80 taking down sub main wiring of any sizes complete all as specified and directed 81 arbouriculture work laying of lawns including ploughing leveling breaking of clods manuring & removal of stones etc. (cost of manure or extra good earth to be paid separately) maintenance of lawns for 30 days more till the grass forms a thick lawns free from weeds & fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost. in rows 5 cms. apart in either direction 82 supply of different flower plants 900mm to 1500mm at site including loading / unloading & transportation etc.complete all as specified and directed 83 supply of different varieties of shrubs 600mm to 900mm at site including loading / unloading & transportation etc.complete all as specified and directed 84 supply of different varieties of climbers 900mm to 1500mm at site including loading / unloading & transportation etc.complete all as specified and directed 85 supply of different varieties of palms in polyethylene bags / earthen pots according to height growth & age of the plant at site including loading / unloading & transportation etc .complete all as specified and directed 86 supply & planting of shady plants (neem, peepal, goolar, jamun, imli or other specified) along including the following activities :-(a)preparation of soil including & removing of unwanted shrubs removal of stones & garbage.(b) supply of plant at site of two years of age & height more than 1.50mtr.(c)supply of dry manure (farm yard manure.(d)supply of insecticides.(e)digging of pits size 60x60x60 cms. 87 supply & planting of ornamental plants (kachnar, amaltas, gulmohar, arjun, jacranda etc. or other specified) along including the following activities :-(a)preparation of soil including cleaning & removing of unwanted shrubs removal of stones & garbage.(b)supply of plant at site oftwo years of age & height more than 1.50mtr.(c)supply of dry manure (farm yard manure organic).(d)supply of insecticides.(e)digging of pits size 60x60x60 cms. including removal of stones, manu-ring application of insecticides & watering at least15 liter per plant after planting.(f)watering to plants.
  • View Tender
  • Document
  • Bid Support
7 Security Services
image image
Central Government/Public Sector
TRN :49054604 |  13 Jun, 2025
Tender Value : 70.50 Crore
 Kochi - Goa
Tender for tender for provision of cgsd (kochi) at willingdon island, kochi; 1 schedule a part - i (building & structure works)details of prepriced schedule is given in tender documents. 2 schedule a part-ii ( site clearence/development & earth works) details of prepriced schedule is given in tender documents. 3 schedule a part-iii (internal water supply) details of prepriced schedule is given in tender documents. 4 schedule a part-iv (internal electrification) details of prepriced schedule is given in tender documents. 5 schedule a part-v (fire fighting)details of prepriced schedule is given in tender documents. 6 schedule a part-vi (road/path/ hard standing/culvert)details of prepriced schedule is given in tender documents. 7 schedule a part-vii (external water supply) details of prepriced schedule is given in tender documents. 8 schedule a part-viii (external electrification) details of prepriced schedule is given in tender documents. 9 schedule a part-ix (sewage disposal) details of prepriced schedule is given in tender documents. 10 schedule a part-x (area drainage) details of prepriced schedule is given in tender documents. 11 schedule a part-xi (compound wall) details of prepriced schedule is given in tender documents. 12 schedule a part-xii (organic waste converter and smart energy meter) details of prepriced schedule is given in tender documents. 13 schedule a part -xiii (miscellanious items) note:- this schedule is not pre-priced by mes and the pre-priced rate indicated as rs 0.00 under col. e signifies this fact only. 14 internal water supply s & f for 15 mm dia bore cp two way bib cock with cp wall flange (make : jaquar model no. opp15041pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 15 s & f for 15 mm dia bore cp bib cock with cp wall flange (make : jaquar model no. opp15037pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 16 s & f for 20 mm bore concealed stop cock reqular brass body with spindle extnwith exposed part kit of concealed stop cock with fitting sleeve, operating lever & adjustable wall flange (compatible with ald-083cqt & ald-089cqt)(make : jaquar model no. ald 089 cqt/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 17 s & f for 25 mm dia bore concealed stop cock reqular brass body with spindle extn with flush cock & wall flange 25mm ceramic disc cartridge) with plain knob (make : jaquar model no. ald 081/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 18 s & f 20mm bore cp angular stop cock with cp wall flange (make : jaquar model no. cqt 23053 / eqvlt in kohler/grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 s & f for 100 mm overhead shower rose round shape single flow (abs body chrome plated with gray face plate (make : jaquar model no. 1989 with sha 479l300s / eqvlt in kohler/ ess ess) with shower arm ø20mm & 300mm long round shape with 90° bend for wall mounted showers with stainless steel connected to pipe complete all as specified and directed by engr-in-charge. 20 cooling appliancesdesign, supply, installation, testing and commissioning of invertor type floor mounted packaged ac units of specified capacities, combination of energy efficient inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include group controller also asrequired for controlling ac from a single point and timer option for load sharing of ac units complete all as specified and as directed by engineer - in - charge, of following capacities.note: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. (high side (machines))(outdoor unit) 21 a) 22 tr inverter package ac units 22 b) 16.5 tr inverter package ac unit 23 design, supply, installation, testing and commissioning of normal type floor mounted packaged ac units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include support works for outdoor units with necessary catwalk for service access complete all as specified and as directed by engineer - in - charge, of following capacitiesnote: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. low side (machines))(indoor unit) 24 a) 22 tr inverter package ac units 25 b) 16.5 tr inverter package ac unit 26 supply, installation and testing of refrigerant pipingwith necessary clamping (suction & discharge) hard/soft drawn copper tube of suitable sizes, with copper elbows, tees, tubular nitrile insulations etc as required complete all as specified and as directed by engineer - in - charge. 27 s & f control cabling b/w indoor & outdoor units 28 m & l refrigerant gas - r410a 29 supply, installation and testing of hard pvc drain piping. drain piping with tubular nitrile rubber insulation: complete in all respects, well clamped till drain points complete all as specified and as directed by engineer - in - charge. for all units 30 ductingsupply, fabrication, installation, testing of gi rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per is 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by engineer - in - charge. 31 a) using 0.63 mm (24 gauge) gi sheet 32 b) using 0.80 mm (22 gauge) gi sheet 33 c) using 1.00 mm (20 gauge) gi sheet 34 duct insulation & liningsupply and installation of acoustic insulation of ducts using 9mm open cell nitrile rubber, well adhesived, 150 - 180 kg/cm2 complete all as specified and as directed by engineer - in - charge. 35 supply, installation & testing of thermal insulation of ducts using 9mm closed cell nitrile rubber, well adhesived, 40-60 kg/cm2 complete all as specified and as directed by engineer - in - charge. 36 s & f canvas connection 37 air distribution productssupply and fixing of powder coated aluminium grills/ diffusers (supply/ return) complete all as specified and as directed by engineer - in - charge. 38 s & f collar dampers 39 supply and installation of fire dampers complete all as specified and as directed by engineer - in - charge. 40 supply, installation, testing and commissioning of heater bank plus humidistat arrangement complete all as specified and as directed by engineer - in - charge. 41 supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier hima 7 nhc, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, ac power supply with all connecting accessories complete all as specified and directed. 42 supply and fixrefrigerator, electric driven (single phase), 220 v,50 hz, capacity 195 litres, 3 star rated direct cool inverter, single door all as specified and directed by the engineer-in-charge. 43 supply and install, testing and commissioning of split type air conditioner 1.5 tr capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (cooling appliances- qty 4, air conditioning- qty 10) 44 supply and fix voltage stabilizer 3 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% 45 supply and fix voltage stabilizer 4 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% (cooling appliances-qty4, air conditioning- qty 10) 46 air conditioningsupply and install,testing & commissioning of split type air conditioner 2 tr capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 supply and fix voltage stabilizer 5 kva for automatic operation,single phase naturally air cooled indoor type, wall mounted type & designed for input variation between 170 v to 280 v with output voltage stabilized at230 v with accuracy of ± 2.5% 48 internal electrifications & f led mirror light 1 x 5w lumos ecco 1 feet make: luker or equivalent 49 s & f modular mcb dbox 3 pin socket with mcb sp 20 amp, 240 v including plastic enclosure as per manufacturer instruction fixed on wall surface complete for air conditioner all as specified and as directed. (make:-havells, model-dhdmcsn0251016 or equivalent) 50 supply and fix air circulator of 600 mm sweep ac single phase. 230v, 1440 rpm complete all as specified and as directed. (make: havells model, turbo force wall or equivalent) 51 s & fvertical triple pole & neutral (vtpn), double door, 16-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 52 s & fvertical triple pole & neutral (vtpn), double door, 4-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 53 m & l for flame proofmcb distribution board spn 12 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb -10 nos as outgoingcomplete all as specified and as directed. 54 m & l for flame proofmcb distribution board spn 8 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb- 6 nos as outgoingcomplete all as specified and as directed. 55 supply and fix engage light with green & red led complete all as specified and as directed 56 supply and fix of cs mounted high intensity led search light, long range, manually swivel in all direction, 250 w, minimum range 700 meters, single, led efficiency> 140 lm/w, pf> 0.95, cct 5500k - 6500k, optical grade pmma/pc lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti uv, narrow beam 5 degree, die cast lm6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree c, input volt 100-300 vac, 50 hz, pf >0.95, ip-66, confirming to lm79/ lm80 and type tested as per is: 10322/ is: 13383, bis approved and govt lab tested for lux intensity. the search light is completed with manual revolving cs stand d20cm x h15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. model no. cs-lrfll-25pc25 of kalin make or equivalent 57 supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, enystar emptyenclosures, ip-65, weatherproof, corrosion free, halogen and silicon free, frame retardant with opaque lid size-[276 x 546 x 186]mm and transparent hinged lid, completed all as specified and directed. 58 m & l for tv socket module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 59 m & l for telephone jack with module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 60 supply and lay coaxial cable for tv cabledrawn through conduit 61 s & f flame proof exhaust fan 300 mm sweep, single phase, 1440 rpm complete all as specified and as directed. 62 fire fightingsupply and fix foot valve conforming to is 4038, 100 mmdia. 63 supply and fix foot valve conforming to is 4038, 150 mmdia. 64 supply and fix cast iron air valves with single air outlets, conforming to is 14845 of size 100 mm dia bore and fixing up in cast iron water supply mains of size 100 mm dia. 65 s & f sprinkler flexible drop pipe 1 mtr long. 66 s & f sprinkler rossette 25 mm dia. 67 supply and installation, testing and commissioning of analog addressable type active loop repeater (loop power/external power) fire terminal with inbuit turbo isolator, backlit lcd display 6x40 characters display, having controls for reset, mute, accept, silence alarms and self test, with programmable free keys and duly approved byen54/lpcb/vds/fm make: siemens/notifier/bosch 68 m & l for low smoke zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to bs7629-i, bs6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier type lt53 outer sheath confirming to bs 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 staircase signage down of make bajaj cat part no. 111499 model no. dsdwbb 3w double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 s & f wall mounted led emergency exit signage luminaire lit up using regular mains supply comes with a unique rechargeable ni-cd battery capable of emergency back up upto 05 hours(cat no. 220211 make bajaj or equivalent to cg/havells. 71 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board , made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and comprising of the following:- make of mccb/mcb -mds/legrand/l&t/hegger (main fire fighting panel)incoming(i) mccb 4 pole 160 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release - 01 no.(ii) voltmeter digital type 0-500 volts range flush type with selector switch- 01 no(iii) aluminium bus bar tpn - 200 amps- 1setoutgoing(i) mccb 3 pole 125 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release- 01 no.(iii) mcb tpn 32 amp -02 nos(iv) 80 hp s/d starter- 01 nos(v) dol starter 7.5 hp- 01 nos(vi) motor protection relay32-88 amps- 1 no. (vii) motor protection relay2-5.5 amps- 1 no. (viii) on/off/trip indication lamps, 220 v ac- 6 nos.(ix) start/stop push button, 2 no. (x) phase indicating lamps ryb for incoming and each outgoing connection.(xi) digital type ammeter 0- 150 amps with selector switch and ct coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 m & l for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per is-10221.the coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per is specification 73 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board, made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and & directedby engr-in-charge comprising of the following :– ( booster terrace pump panel)incoming:-(a) incoming mccb 40 a 25 ka, 4 pole- 01 no.(b) busbar tpn of size 100 apms - 1 setoutgoings:-(a) mcb 3 pole tpn 32 amps,10 ka-2 nos.(b)dol starter for 7.5 hp pump set-1 nos.(c) ammeter class-1, digital panel mounting type 96mmx96mm l & t cat no wds301fca00 including ct 50x5 amps 3 nos & selector switch-4 nos(d) voltmeter class- 1, digital panel mounting type 96mmx96mm l&t cat no.wds301fev00 & selector switch - 1 no.(e) led type indicator lamp 1 set (set of three for r,y,b)(f) mini protecrionrelay 4-11 amp - 1 nos. 74 fire extinguisher mechanical foam type trolly mouted of 9 liters capacity. ceasefire 9 litrs fire extinguisher afff foam type, external cartridge type, pressure guage gross weight 14.6 kg, empty weight5.6 kg, can height 611 mm, diameter 175 mm, discharge time less than 60 secs controllable discharge mechanism, minimum 6 mtrs, applicable on class a, b, can construction deep down & co2 mig welded valve construction: forging & machining, internal coating of can: epoxy powder coating, external coating of can: epoxy poyster powder coating sheet metal thickness 2.0mm,1 year warranty. make cease fire or equivalent. (pol store) 75 supply, installation,testing & commissioning of carbon dioxide (co2) type fire extinguisher of 4.5 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 76 supply, installation,testing & commissioning ofdry chemical powder (abc) stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 77 supply, installation,testing & commissioning of water mist high pressure stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 78 supply and installation at approved location approved make fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & showel etc, complete. 79 special equipments for storesdesign, manufacture, supply, installation, testing and commissioning of automated storage and retrieval system with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. automated storage and retrieval system shall consist of computer controlled & plc stacker crane driven system for automatically placing & retrieving materials from defined storage locations. the crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 kg (max) complete all as specified and directed by the engineer-in-charge. technical data for design of heavy duty asrs:-(a) dimensions:-height:10 mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)storage capacity:-pallet size: 1300 (w) x 1200(d) x 1250 (h) in mmpallet nos.: 480pallet load capacity: 1125 kgtotal capacity: 540 tons(c) stacker crane: single mast automated stacker crane for handling pallet, size 1300mm(w) x 1200mm (d) x 1250mm (h) and pay load (including pallet self weight) of 1125 kg max. the stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. stacker crane will be mounted on single rail at the bottom to traverse the length of the storage system. a single top rail mounted on the racking system shall also support it.general technical parameters of stacker crane:technical parameters/type- single mast(i) operation mode (networking)- on-line automatic / single automatic (ground/boarding) /manual operation (boarding) / maintenance (ii) communication means- wireless 80 (iii) power supply mode- 380 to 415 v, 50 hz, three phase five wire (iv) addressing mode- horizontal and verticle operation: photo electrical sensor + bar code scanners(v) positioning / reduction accuracy (mm) level- lifting ± 3 - 5, fork : ± 3(vi) fork unit- 1 double deep fork(vii) load unit- ms pallet (viii) total height- 10 mtr(ix) the normal lifting speed (m/min) - 10 mpm(x) the normal running speed (m/min) - 65 mpm(xi) rated load- 1125 kg(xii) receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- conveyor(d) pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 kg at height up to the last loading level in the racking system. it should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.pallet details:-(i) dimensions - 1300mm(w) x 1200mm(d)(ii) pallet height- 1250 mm(e) racking system :- two aisle having two row racking system each with 05 verticle levels for storage of material. racking for double deep type storage of 480 pallet of size 1300mm(w) x 1200mm (d) x 1250mm (h). loaded pallet weight: pay load with pallet 1125 kg max. system details:-working aisle -01 nos. (double deep)store rack -24 nos./rowtotal rack in 1 aisle-24 (left) + 24 (right)= 48 nos.no. of level- 5 nos/racktotal pallet-48 x 5 x 2 = 480 nos.load capacity- 1125 kg/levelsingle mast stacker crane-01 no. 81 (f)aisle equipment:-this will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. the mechanical aisle equipment of bottom rail shall consist of i beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. top rail shall be mounted on the racking. the electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) details of rack members:-the racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) loading- unloading station/ conveyor(i) pallet load 1125 kg max.(ii) bearing- skf equivalent make(iii) motor- seimens/sew euro drive/nord sew/ bonfiglioli or equivalent(iv) gear box- bonfiglioli make or equivalent(v) v.f.d.- yashkawa make or equivalent(j) all steel surface shall be powder coated finish with 8 tank treatment process.(k) maintenence: the annual maintenence of complete asrs system duyring the defect liability period of two years shall be included in the rate quoted for the system and the amc contract duly signed with the manufacturer of the asrs system shall be submitted at the time of handling over the system. the amc shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountnote- 1mechanical safety provision (i) end of aisle shock absorbers / bumpers for stacker crane.(ii) end of travel buffer for the lifting crane.(iii) safety catches on lifting carriage.(iv) anti-tilt mechanism for the stacker crane.(v) continuous rail cleaning brush for floor rail.(vi) adjustable rail clamp to ensure alignment. 82 (vii) resilient rubber pads on adjustable clamps for vibration dampening.(viii) profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. note - 2 electrical safety provision (i) there shall be emergency stop push button at all panels and stations.(ii) optical light beam amd mechanical safety sensor to stop the operation in case of improper storage or obstruction in the operator window either internal or external reasons like operator hand or material placed at edge of the tray.(iii) back up circuitry for proper system operation.(iv) an electromagnetic brake shall be used to avoid the slippage of the hoist.(v) stopper shall be provided for the maintenance door.(vi) load cells shall be provided for the over weight of tray.(vii) automatic door shall be provided for operator safety while machine in operating condition.note - 3 physical safety provision (i) the asrs system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. height of the fencing should be minimum 2.0 meter.(ii) one no. of electromagnetic aisle access door shall be provided. it should cover the complete length of the system on one side.(iii) a manual locking system to restrict the movement of unauthorised personnel shall be provided.note: design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. item no. 13.070 below shall be compatible with this item/ system and both should be integratedmake of asr system:armstrong ltd/ godrej koerber/ kardex india storage solutions pvt ltd/ daifuku india pvt ltd/ addverb technologies ltd/ craftsman automation ltd/ tech-mark 83 supply, installation, testing and commissioning of advance inventory management system with computer hardware with compatible inventory software complete all as specified and directed by the engineer-in-charge. technical specification of the system(i) system height : 6400 (±100) mm(ii) system width : 3150 (±100) mm(iii) system depth : 2300 (±100) mm(iv) system base : 7.24 sq.mtr(v) tray int. size: 300 (h) x 2450(w) x 500 (d) in mm(vi) tray dead weight - 57 kg (approx.)(vii) per tray weight capacity - 300 kgtechnical specification of the system:-(viii) tray quantity : 32 nos.(ix) usable net load - 9.6 ton(x) storage surface area per system - 39.2 sq mtr(xi) door - automatic(xii) power consumption - 3.7 kw(xiii) power supply - 440v, 50/60 hz, 3 phase(xiv) motor 3 phase 1440 rpm - seimens make or equivalent(xv) chain - diamond makeor equivalent(xvi) bearing - skf/ntn make or equivalent(xvii) external cladding - epoxy powder coatedsafety features:1. photo curtain at access port, 2. motor protection relays, 3. limit switch at door, 4. single phase preventer,5. switch mode power supply, 6. 15 min battery backup for plc, 7. noise less than 60db, 8. emergency stop various safety alertsnote: the system and software provided under this item shall be of same make as for item 13.069 or a compatible system and software as recommended by the chosen manufacturer of asr system. this system shall be integrated with asr system. 84 supply, installation and testing of car traffic boom barrier 6 mtr suitable to working on power supply 230 volt, 50 hz, 24v dc electric motor, adjustable with cams, operating ambient temperature from -20 to +55 degree celsius, uses cycle 2000/day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 nm open/close time 2 to 4 sec complete all as specified and as directed by engineer-in- charge.make: faac/parkilo/skidata/bft 85 external water supplysupply and fix foot valve conforming to is,100 mm dia complete all as specified and directed. 86 supply and fix cast iron air release valve with 100 mm bore and two outlets as per is:14845 complete all as specified and directed. 87 supply, installing, testing and commissioning of electrically driven horizontal centrifugal pump set 9.0 lps at 50 meter head as per specification, motor tefc type, 2880 rpm, 415 v, 50 hz, 3 phase, class f insulation, ip 55 protection, starting on suitable star delta starter. the pump shall be horizontal, end suction, top discharge. the pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on rcc (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 lpm at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, pvc insulated copper cable connection from starter to the motor terminals all as specified and directed by the engineer-in-charge.(01 no. working + 01 no stand by)make:- kirloskar brothers/crompton or equivalent. 88 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.0 mm thick crca sheet, cpri approved having, ip 43, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply, bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2.0 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: lt panel for pump house. the lt panel comprising of the following:- 89 incoming:-mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, breaking capacity 36 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 01 sets(b) digital multi function meter - 01 no.(c) cts - 100/5a, cl-1, 15 va - 01 set(d) horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 350 amps for phase and 350 amp for the neutral baroutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 16 ka- 02 no. ics =100% icu -2 nos.(b) mcb, tpn 40 amp, 415 volt, c curve - 02 nos.(c) star delta starter 12.5 hp, 3 phase, 415 volt- 02 nos.(d ) digital ammeter - 2nos.(e) single phase preventer - 2 nos. 90 m & l valve chamber of internal size 0.90m x 0.90m x 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick pcc in 1:4:8 type d2 foundation, brick work in cm 1:6, 15 mm thick rendering in cm 1:4 to internal surfaces and external surfaces upto 150mm depth below gl, pcc 1:3:6 type c1 as in coping, cover with two nos. of hinges and one no. handle made out of ms round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. note:- the quoted rate shall include all earthwork and connected items. 91 m & l earthing complete with galvanized steel earth plate electrode of size 600mmx600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal gl and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in electrical plate no. 3 connecting to earthing test point, including necessary earth work in any type of soil, pcc earth chamber made in pcc 1:3:6 type c1 (using 20mm graded aggregate), common salt, charcoal, ci funnel, earth pit cover in rcc 1:2:4 type b1 (using 20mm graded aggregates), with 8mm ctd bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 external electrificationm & l for ht/lt ms cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm ms strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of pcc 1:4:8 type d-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.note: ht route indicator shall be painted as under:-(i) for ht 11 kv cables - “brown”(ii) for lt cables - “blue” 93 supply and fix compact air insulated bus bar trunking system with copper busbar 1600 amps, 50 ka breaking capacity, ip54 protection, bus duct 1600 a, 415 volt, capacity sandwich type, set rybn complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to lt panel board complete all as specified and directed. 94 supply, install, testing and commissioning of distribution transformer step-down level 2 (previously ee level 3 before amendment no 4 to is 1180), 11kv0.433kv, three phase complying withis: 1180/iec-76(part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 hz system of capacity 800 kva, oil immersed naturally cooled delta connected on ht side and star connected on lt side, vector group dyn11, provided with off load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & half load (50 %) shall not be exceeded 5838 watts & 2147 wattsrespectively as per grlha rating, percentage impedance: 4.5%. losses and impedance are subjected to tolerance as specified in is 1180. the transformers should be supplied with first filling of oil confirming to is 335. the transformer should have both side cable end box with neutral brought out complete all as directed by engineer - in -charge, and installation of transformer shall be carried out as per is-10028and comprising with the following standard fittings/technical specifications:-(a) lifting lug for transformer and tank.(b) earthing terminal rating and diagram plate.(c) air release device.(d) oil filling inlet pipe with plug.(e) drain outlet pipe with brass gate valve.(f) conservator tank with oil level indicator(g) silica jel breather(j) first fill of oil upto level including conservator tank with fresh new oil conforming to is335.(k) type of connection delta/star(l) type of cooling: oil and natural air.(m) vector group: dyn 11.(n) temperature rise over an ambient of 50 °c maximum.(o) cable end box on both side for ht/lt cables of suitable size.(p) provision of thermometer with pocket.(q) provision of oil and winding temperature gauge. 95 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: the lt panel comprising of the following:- main lt panelhorizontal copper busbar for 3 phase, 440 volts, 50 hz, 4 wire system of rating 1600 amps for phases and 1600 amps for neutral. 96 incoming:-incomer:-acb 4 pole, 415 v, 50 ka with thermal magnetic release (manual draw out type) of capacity 1250 ampmetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 1600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, ics =100% icu, breaking capacity 35 ka, ics =100% icu- 02 no. (for dg amf panel & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for apfc panel & fpb 2 near bulk store) (c) mccb, thermal magnetic release, 4 pole, 415 volts, 320/315 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for fpb 1 near adm block) (d) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for existing load)(e) mccb, thermal magnetic release, 4 pole, 415 volts,125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for fpb 3 near auction disposal store)(f) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for mt complex, watch tower no 2, guard room)(g) digital ammeter with suitable ct for each outgoing 97 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (near admn bldg) 98 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral.incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for 2nd floor & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for 1st floor)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for g floor)( d) digital ammeter with suitable ct for each outgoing 99 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.2 (near bulk store) horizontal aluminium busbar for 3 phase,440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral. 100 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for equipment load & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for bulk store)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for watch tower no. 1)( d) digital ammeter with suitable ct for each outgoing 101 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.3 (near auction disposal store) 102 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 200 amps for phases and 200 amps for neutral.incoming:-(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, breaking capacity 25 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 200/5a, cl-1,15 va - 01 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, ics =100% icu breaking capacity 25 ka- 02 no. (for store dispatch complex & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for pol store, auction disposal store, covered hard standing)(c) digital ammeter with suitable ct for each outgoing 103 supply and fixing poly carbonate street light junction boxes ip 66/67 weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitablecable connecting terminals, cable lugs, including provn of one no. mcb sp 6 amps for operating the street light fittings, suitable cable glands as per site requirement, all as directed by the engineer-in-charge. 104 s & f street light bracket made out of gi tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary ms clamp-02 nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core frlsinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.note: phase should be red/yellow/blue, neutral should be black and earthing wire should be green in colour. two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 supply and fixing of led ?ood light, 200w, watt 230 v, ac outdoor type with thermal management in multiple optics and equipped with ip66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power leds and secondary lenses with ip protection incl system efficiency >110/120lpw 10kv spd included energy saving, environmental friendly and general purpose lighting complete all as specified and directed engineer-in-charge. make : make : crompton/philips/wipro 106 supply and fix high mast panel outdoor type, suitable to take load up to 6 kw, conforms to is/iec 60947-4-1, provided with protection degree ip 54, extended wide band (150 vac - 300 vac) coil, frls (fire retardant low smoke) internal wiring, in-built short-circuit protection, class h insulation, 3 phase 415 volts ac with the following accessories:phase : 3 phase, 415 voltsmax load capacity : 6 kwtimer type: astronomicalcontactor rating : 32 a tpmcb rating : 63 a tpnmake : crompton/ philips/wipro 107 supply and laying dwc (double wall corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming is 16205 (part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm st light cable & 16 sqmm cable) 108 aviation obstruction lightsupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one no.10 a, mcb, spn 230 v with fixed enclosure complete all as specified and directed by engineer-in-charge.make:- bajaj cat no bgav 302 led or equivalent in philips/crompton/surya 109 incineratorsupply, fixing and testing of solid waste electric incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°c, stainless steel stack for longevity, fitted with a velocity cowl as standard, chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree celsius mounted on foundation as recommended by oem including electrical control panel with suitable size mccb, relays & contactor recommended by oem complete all as complete all as specified and directed.note:(a) the electrical works including electrical lt panel, internal wiring of the lt panel, suitable size copper wires from panel to solid waste electric incinerator as recommended by oem to operate the solid waste electric incinerator of capacity 100 kg/hr to make solid waste electric incinerator operational is deemed to be included in the rate quoted. (b) all electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed there under and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solid waste electric incinerator of capacity 100 kg/hr all as mentioned above and which is not mentioned or included in this schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) foundation/plinth/base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the solid waste electric incinerator and height of plinth shall not be less than 0.5 m 110 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, breaking capacity 36 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 electric sirensupply and fixing sirens electronic type horizontal double mounting three phase 400/440v, 2800 rpm 50 c/s flame proof, audible range 3.5 km, 2 hp, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 supply and fix advance sirens controller electronic type suitable to operate on 3 phase, 415 volt ac 50 hzcomplete all as specified and directed. 113 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 25 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 solar power plantdesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (on-grid) on roof top of existing bldg of capacity 150 kwp, power evacuation at 415 volt 3 phase system all as per guidelines/norms issued by mnre & indian metrological deptt approved solar radiation data viz direct normal irradiance, global horizontal radiance etc complete comprising with the following solar photo voltaic plant.(a) design, supply, installation, testing and commissioning of solar pv modules capable of generating 150 kwp (ac) electricity at 415 volt 3 phase system. these solar pv modules of 540 watt perc with a modular efficiency of 17-19.84% as per iec and mnre standard or as per approved design parameters with poly/multi crystalline silicon solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to iec 61215, iec 61730, iec 61701. solar pv module should be of approved indian brand only and qualify under the domestic content requirement (dcr) norms of nvvn/seci and testing requirement fixed by mnre. the pv modules shall be warranted for a period of minimum 25 years, solar pv modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of ten years and 80% at the end of twenty five years. each solar pv module must use rf identification tag. the following information must be mentioned in the rfid used in each module:name of manufacture of pv module, name of manufacturer of solar cell, month & year of manufacturer (for solar cell and module), country of origin (lt is mandatory to use cells and modules manufactured in india). i-v curve of the module, wattage, lm, v-m, & ff for the module, unique serial no & model no of the module, date & year of iec pv qualification certificate, name of the test lab issued iec certificate. the pv modules used in the solar power projects must qualify to the latest edition of the following international electro technical commission (iec) p module qualification test or equivalent bis standards. the pv module must be tested and approved by one of the iec authorized test centres. 115 (b) material and labour for module mounting structure (mms) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 kmph wind speed all as per approved design parameters as per mnre standards and to match with the existing site conditions. necessary roof treatment to avoid any seepage in future shall be done by the contractor and the amount included in the rate quoted. the roof tiles shall be dismantled and refixed back in original position. structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) supply, laying & testing of dc cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant is, weather proof uv resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of spv modules to array junction box including suitable size of cable lugs, male & female mc4 connectors & joints etc.(d) supply, installation test and commissioning of protection devices mccb 400 a, isolator and three phase 4 wire lt energy meter, array junction boxes having rating 150 kwp with over voltage protection and surge protection.(e) supply, installation, test and commissioning of grid tie solar power conditioning unit / inverter of minimum capacity 150 kwp(dc to ac 415 v in three phase system) all as per approved design parameters & capable of generating output voltage 415 v ac at rated load condition with efficiency not less than 98 %, conforming to iec 600682-2 nde standards with power reduction, lvrt with protections for anti-islanding, ground fault monitoring, grid monitoring, ac & dc over voltage and under voltage protection, ac & dc short circuit lover current protection and dc reverse polarity protection, graphic display etc. all as specified and as directed.(f) material and labour for earthing for lightning protection for spv modules etc as per ie rule, mnre guide line & bis all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including gl strip 32x6mm size protected with gl medium grade pipe 40mm dia for earth electrode up to test point by means of gi nuts, bolts, check nuts and washers including earth work excavation, pcc (1:3:6) type cl pit and rcc cover ( 1:2:4) type bl and funnel, with necessary charcoal, salt etc complete. 116 (g) supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for spv modules lightning protection upto interconnection between roof top la to ground earthing system. (h) ac cable: supply and laying of 150 sqmm lt xlpe insulated, screened pvc bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to is 150 sqmm x 3.5core as per site requirement.note (i) :-(a) before quoting the bid, contractor or his authorised engineer/consultant must visit the proposed site to study the site condition.(b) before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to accepting officer for approval.note(ii):-(a) the mechanical structures, electrical works and overall workmanship of the grid solar power plant must be warrented for a minimum of 5 years.(b) all mechanical, electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed thereunder and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 kwp (ac) all as mentioned above and which is not mentioned or included in this schedule a but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) contractor shall provide adequate spares/items required for minimum period of 1 year maintenance including dc & ac items under scope of work.note (iii) : design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. 117 dg setsupplying, installing, testing and commissioning, factory assembled silentdiesel engine driven generator set, fully wired alternator ac to give an out put of 400 kva continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 hzsupply, 1500 rpm, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, pcc foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a)diesel engine: liquid cooled turbo charged with after cooler to deliver suitable bhp at 1500 rpm under ntp conditions of bs 5514 and conforming to is 10001/ 10002, din 6271 & iso 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class a1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) radiator with blower fan or heat exchanger with guard.(b) pipe coupling for engine cooling system piping.(c ) corrosion inhibitor coolant(d) paper element filters(i) fuel filter(ii) lube oil filter(iii) by pass(e) fly wheel housing and fly wheel to suit alternator.(f) engine bearing mechanism in fly wheel housing.(g) shut off coil with safeties for llop/hwt/over speed.(h) dry type air cleaners and vacuum indicators.(j) residential silencers.(k) stainless steel exhaust flexible bellows. 118 (l) motor driven priming pump.(m) battery charging alternator.(n) exhaust piping made out of stic c class, ms pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(o) mineral wool insulation 2 inch thick suitable for 400 degree celsius temperature cladded with aluminium sheet o30 gauge for the entire length of exhaust pipe.(p) first fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) interconnecting copper cabling of adequate capacity batteries control.(r ) fuel pipe class stic 1 /1.5 /2 dia - 01 lot(s) self starter 12 volts dc.(t) electric operated electronic governor.(u) fuel injection pump.(v) no of cylinders - 12 no vee(w) electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24v battery. (ii) water temperature.(iii) lubricating oil pressure.(iv) engine speed -1500rpm(v) engine hours(vi) frequency.(vii) voltage.(w) safety control (trip and indication).(i) high water temperature(ii) low lube oil temperature(iii) overspeed stop 119 (x) base frame: sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith avm pads.(y) battery:-24 volts(2x12v battery) dc, 180ah, maintenance free battery conforming to is:14257 with leads & terminals (make- excide/amron).(z) fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick hr/ms sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) isolator panel with 250 amp mccb(ab) auto logic panel for automatic stat(b) alternator: alternator suitable rated for 400 kva, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 hz at 1500 rpm, self excited and self regulated with avr brushless, screen protected, drip proof , insulation class-h, ip -23, voltage regulationgrade - vg 3 self ventilated and conforming to bs: 5000 / is: 4722 suitable for engine as mentioned here-in before, conformig to is: 13364(part-1)make: koel green / stampford/crompten/kirloskar/greaves(c) acoustic enclosure:- m & l for acoustic enclosure for the above 400 kva dg set to reduce noise level to 75 db measured at 1.0 meter distance for audible frequencies as per guide of central pollution control board andmanufacturers specification and comprising of following from authorised goems of gen set manufacturers specified :-(i) sound insulation : 100mm thick rock wool (density 64 kg/cum).(ii) outer body : 1.6mm thick crca(iii) door : 1.6mm thick crca(iv) base frame : ismc 300(v) inside illumination : 1 no.- 1 x 18 watt led fitting of make phillips/ bajaj/ crompton.(d) amf control panel:- factory fabricated cubicle type, free standing, floor mounted, indoor type, ip-43, amf control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick crca sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (e) amf control circuit with 4 pole mccb 630 amps - 2 nos, with ultimate breaking capacity icu-50 ka at 415 volts and microprocessor release conforming to iec 60947 part-i with breaking capacity ics=icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 nos. for main supply & dg set supply with hrc back up fuse complete with all dc control relays/ line voltage monitor (lvm) as per oem specifications incorporating motorised stored energy operating engine start, stop, three attempt starting facility and failure to start etc.(f) digital load manager : three phase 4 wire indicating v,i,pf, kva, kw, f of enercon make with serial communication port model no.em6400 with class 1.0 accuracy meter or equivalent make suitable rating of ct per phase- one no.(iii) indication lamp r, y, b with 3 nos. of 2a hrc fuses-10 sets.(iv) bottom gland plate for incoming and outgoing cables.(v) circuit diagram plate.note :- dg set should be as per cpcb -4 latest norm wef 01 july 2023 of national clean air programme (nacp) act 1981. 121 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (dg panel ) 122 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 800/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for package ac bulk store & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for pump house & fire pump)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 80 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for incianator)(d) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 07 no. (for terrace pump 1, terrace pump 2, power house, high mast 1, high mast 2, street light)(e) digital ammeter with suitable ct for each outgoing(f) astro time switch for 3 phase 20a- 1 no(g) 3 phase power contactor 20 amps, with 230 coil 123 sewage disposalm & l for laying of dwcpe sewage pipes line 200 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 m & l for laying of dwcpe sewage pipes line 150 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 compound walls & f concertina coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm gi wire for securing, coil with fish hook bars, incl necessary welding to ms sections etc all as specified and directed. 126 green building norms(griha concept)supply and install organic waste converter fully automatic having capacity 50kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-type of machine: fulley automatic in-vessel compostercomposting method: 24 hrs. micro-organisms-based compostingmachine type of microganism used: heat resistant thermophilic bacteria final output: dry organic soil conditioner/soil supplementscycle time: 24hrs volume reduction in 24hrs: 80-85% internal tank: stainless steel type main agitator shaft: stainless steel type input voltage: 415vspecial features: vfd as standard across all models, touchscreen standards daily waste processing: 150kgs rated capacity: 7kwpower consumption (kwh par cycle): 13-15length: 1650, width: 850,height: 1455 127 supply, installation, testing and commissioning three phase energy meter with the following specifications: microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (nb-iot) communication that allows it to interact with the head end system (hes) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 volts, 50 hz of range 10-100 amps, complying to is16444:2015 (reaffrimed 2020) and conforming to is 3779 with led display and parameters like voltage, current, frequency, power, power factor, kwh/kva, default in built dual source, inbuilt long range (lorawan) communication suitable for outdoor lora data accumulator and also compatible for prepaid and postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to erp complete with 5 years warranty.note:(a) the contractor would be responsible for removing the existing meter, noting down the reading and depositing it with the mes age e/m store complete all as specified & directed.(b) the energy meter to be capable of running in both prepaid and postpaid mode.(c) the meters to carry 5 year warranty. (for entire system) 128 supplying, fixing, commissioning and testing of configuration of cloud hosted multi user web based software with following modules:(i) head end system (hes): to acquire meter data automatically from dcu sand monitor parameters acquired from meters.(ii) meter data management modulethe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. the system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters cumulative energy. cumulative apparent energy (as applicable), power, current, voltage, power factor and frequency(b) monthly billing survey data for cumulative energy and max demand(iii) billing module: the billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. the billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. it would allow postpaid and prepaid functionality as required.(iv) occupation and vacation module: the system would support occupation/vacation based on the unit catagories. the system would support automatic data capture on occupation and vacation events.(v) website: there would be a dedicated website forage/ge and bso team to view all the data and information alongwith customer portal for use of customer. the designated users in mes would have the admin access to the application. the mes staff would also have the access to the key information on mobile app (androiandios based) for admin use complete all as specified and directed.(vi) customer module: the system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. there shall be consumer app (android and ios based) also to log in and view their own energy/billing data and recharge facility.(vii) communication module :the system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) meter master data: the system would support meter data repository. the system would support meter replacement process.(ix) excel export: the system would support export of metering and billing data in excel and pdf format.(x) energy accounting module: the system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) prepayment/recharging facility:the system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. the system should allow online/digital recharging through consumer app (androidand iosbased) and web portal. the configuration and necessary arrangement for payment gateway and e-mro facility shall be deemed to be included in the quoted rate. the system should sendconnect/disconnect command on the basis of available credit.low credit alarm: the system will give an alarm over the consumer app and sms to the registered mobile number in case the credit in the meter goes down be low apredefined limit.emergency credit: the meter will work even when the credit falls down to zero to prevent disconnection. this limit shall be configurable. the system should support happy hours inorder to prevent disconnection in non working hours and on holidays. the happy hours should be configurable complete all as specified and directed. 130 supply, installation, testing and commissioning of dcus/gateways and the arrangement of sim cards or internet to enable reliable medium for two-way communication between smart meter & hes. the data acquisition (push/pull) frequency shall be, configurable. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. it shall have provision for the cellular, wifi and ethernet communication for the backhaul to hes. it shall be capable to handle data of minimum 1000 nos. of any type of smart meter (1ph/3ph).it shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. communication of the nearest meters with other meters shall be established through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. the equipment shall be weather proof and dust proof (minimum rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 hosting gprs (4g) charges for gateway for five years from the date of completion f including 2 years waranty and 2 years maintinance after warranty) make:-airtel/jio/vodafone 132 supply and installation of digital water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 supply and installation of digital water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 arboriculturem & l for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 all as per item no 13.121 above but pit size 60cm x 60cm x 60cm 136 supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 supplying and planting flower plants(champa/ hybrid hibiscus/ hybrid west indian jasmine/ hybrid plumeria white plant/ panama yellow plant/ oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 supplying and planting song of india flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 supply and planting mexican grass including providing manure as directed. 144 pile foundationboring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.note:- the quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. nothing extra shall be paid on this account. 145 boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using dmc method (direct mud circulation)and getting out & disposal of spoil to any distance outside of md land , complete all as specified and as directedby the engineerin charge 146 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in cast in situ dmc bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 149 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 150 all as per item no 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 m & l for providing pcc (1:4:8) type d-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 m & l for carrying out non destructive integrity test all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 m & l for carrying out initial load test (vertical load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 155 m & l for carrying out initial (lateral load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 156 m & l for carrying out initial load test ( pull outtest) of cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 157 m & l for carrying out routine load test (vertical load)all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 158 testing of piles (initial load test) for 450mm dia cast in situ bored piles all as per is including removing the testing equipments from the site after testing is completed all asspecified and as directed
  • View Tender
  • Document
  • Bid Support
8 Non Classified
image image
State Government
TRN :49025685 |  20 May, 2025
Tender Value : 0
 Deoghar - Jharkhand
Tender for tender for expression of interest fob ai-based integrated mela control room (imcr) for shravani mela 2025 part - a 1. cameras 2. drones 3. rfid bands 4. complete infra structure for control room 5. integration with police control room (ccr) 6. led screens part - 2 1. crowd management 2. data integration 3. incident automation 4. live mela updates 5. chatbot ai system 6. biometric/gps fenced attendance system
  • View Tender
  • Document
  • Bid Support
9 Environment And Forests
image image
Government Departments
TRN :48880687 |  17 May, 2025
Tender Value : 70.00 Lacs
 Sidhi - Madhya Pradesh
Tender for supply chain link fencing and barbed wire chain link fencing and barbed wire , laying and jointing pvc pipe. heading , ?????? ???? (????????? / barbed wire) galvanized steel barbed wire - line wire - galvanised steel wire of 2.5 mm diameter point wire - galvanised steel wire of 2.5 mm diameter barbs - distance betbeen two barbs 75mm, the barbs shall have four points and shall be formed by twisting two point wire each two turns, tightly around both the line wire making altogether four complete turns. standard - conforming to is 278:2009 certificate compulsory , galvanized steel chain link fence galvanized steel chainlink fence fabric- size 100x100 mm, dia 4.00 mm mesh wire and 4.50 mm dia line wire 2 nos. upto 2mtr. width and 3 nos. above 2mtr. standard - conforming to is 2721:2003 certificate compulsory
  • View Tender
  • Document
  • Bid Support
10 Road Work
image image
Central Government/Public Sector
TRN :34434981 |  16 May, 2025
Tender Value : 0
 Lower Dibang Valley - Arunachal Pradesh
Tender for gem bids for weld mesh panel , omega clamp with profile cover plate , mushroom head bolt nut with security nuts for omega clamp , inter panel binder , mushroom head bolt nut with security nuts for inter panel binder , fence post , straining y arm , fitting accessory for straining y arm , intermediate y arm , fitting accessory for intermediate y arm , punched tape concertina coil ptcc , galvanised steel barbed wire , hog rings , eye bolt for straining y arm , anchor rod , tie wire , steel gate big size 5.23 x 2.70 m including wicket small gate.
  • View Tender
  • Document
  • Bid Support
  • 1
  • 2
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : chain link fencing panel
  • Wall Fencing Tenders ,
  • Fence Post Tenders ,
  • Aluminium Fencing Tenders ,
  • Barbed Wire Fence Tenders ,
  • Rcc Fencing Tenders ,
  • Fencing Wall Tenders ,
  • Electric Fencing Item Tenders ,
  • Fencing Mesh Tenders ,
  • Fencing Work Tenders ,
  • Fancing Tenders

Get chain link fencing panel Tender Alert...

644947

Related Searched Keywords : chain link fencing panel

  • Disilting Work Tenders From Maharashtra
  • Tube Well Tenders From Delhi
  • Bridge Work Tenders From West-Bengal
  • Subways Tenders From -Tamil-Nadu
  • Compound Wall Tenders From Andhra-Pradesh
  • Ceiling Tenders From Gujarat
  • Lift Irrigation Service Tenders From Karnataka
  • False Ceiling Repair Tenders From Uttar-Pradesh
  • False Celling Tenders From Rajasthan
  • Civil Work Tenders From Madhya-Pradesh

Read More


Tender Document

233967

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Buildings Repair Tenders
  • Underground Sewer Tenders
  • Bridges Tenders
  • Culvert Wall Tenders
  • Borewell Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App