Thetenders.com
  +91 92760 83333 / +91 92743 15555
  • Indian Tenders
  • |
  • Global Tenders
  • |
  • Projects
  • |
  • Tender Awarded
  • |
  • Sub-Contractor
  • Pay Online
  • Register now
  • Login
  • Indian Tenders Tender information of India
  • Global Tenders International Tender information
  • Projects Project information of India
  • Tender Awarded Tender awarded information
  • Sub-Contractor Vendor information of India
  • Pay Online
  • Register now
  • Login
  • Contact Info All India : 9276083333 / 9274315555 South India : 9274315555
TheTenders
»
Indian Tenders
»
Keyword Tenders
»
Anti Static
Filters
  • » By Keywords
  • » By Cities
  • » By States
  • » By Agencies
  • » By Sectors
  • » By Ownerships
  • Tender Value

List of anti-static Tenders

List of latest anti-static Tenders in Indian Tenders. Click on any anti-static Tenders to view BOQ, NIT and Tender Documents. Get GeM Registration and Bidding Support, Vendor Registration for anti-static Tenders.

Advance Search
  • All-Tenders (10)
  • |
  • Today's-Tenders
  • |
  • Active-Tenders
  • |
  • Closed-Tenders
1 Housing Urban And Rular Development
image image
Government Departments
TRN :49054357 |  29 May, 2025
Tender Value : 3.08 Crore
 Aurangabad - Bihar
Tender for tender for special repair & maintenance work at jnv baroon. - structural repair & retrofitting 3 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 4 50 mm average thickness 5 25 mm average thickness 6 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 7 bars upto 12 mm diameter 8 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 9 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 10 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 11 25mm thick in grade m 25 with cement content not less than 330 kg per cum 12 50mm thick in grade m 25 with cement content not less than 330 kg per cum 13 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 14 repairs to roof 15 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 16 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 17 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 18 dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of: 19 asbestos cement sheet 20 providing ridges or hips of width 60 cm overall width plain g.s. sheet fixed with polymer coated j or l hooks, bolts and nuts 8 mm dia g.i. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m* 21 providing and fixing 15 cm wide, 45 cm overall semi-circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m* 22 providing corrugated g.s. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m* 23 providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main t runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross t of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main t at 600 mm center to center to form a grid of 1200x600 mm and secondary cross t of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main t runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer-in-charge. 24 gi metal ceiling lay in plain tegular edge global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of g i sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. 25 repair to plaster and plinth protection 26 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 27 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 28 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 29 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 30 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 31 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 32 with cement mortar 1:4 (1cement: 4 coarse sand) 33 12mm cement plaster of mix : 34 1:6 (1 cement : 6 course sand) 35 6mm cement plaster to ceiling of mix : 36 1:3 ( 1 cement : 3 fine sand) 37 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 38 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 39 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 40 old work (one or more coats) 41 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 42 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 43 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 44 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 45 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 46 repairs to door / windows 47 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 48 of area 3 sq. metres and below 49 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 50 of area 3 sq. metres and below 51 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 52 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 53 renewal of old putty of glass panes (length) 54 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 55 using flats 30x6mm for diagonal braces and central cross piece 56 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 57 35 mm thick including isi marked stainless steel butt hinges with necessary screws 58 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 59 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 60 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 61 300 mm weighing not less than 200gms. 62 250 mm weighing not less than 150gms. 63 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 64 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 65 300 x 10mm 66 150 x 10mm 67 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 68 with 12 mm mild steel u beading 69 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 70 125 mm 71 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 72 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 73 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 74 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 75 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 76 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 77 4.0 mm thick glass panes 78 applying priming coat : 79 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 80 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 81 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 82 two or more coats on new work 83 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 84 one or more coats on old work 85 flooring 86 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 87 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 88 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 89 25 mm thick 90 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 91 25mm wooden planking, tongued and grooved in flooring including fixing with iron screws complete with : second class teak wood 92 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x 600 mm 93 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x 600 mm 94 miscellaneous 95 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. 96 in cement mortar 97 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 98 cement mortar 1:6 (1 cement : 6 coarse sand) 99 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 100 cement mortar 1:4 (1 cement :4 coarse sand 101 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 102 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 103 providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia m.s. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with m.s. tubes, m.s. tube challies, m.s. clamps and m.s. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .the scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of engineerin-charge .the elevational area of the scaffolding shall be measured for payment purpose .the payment will be made once irrespective of duration of scaffolding.note: - this item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. 104 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 105 75 to 80 mm dia pipe 106 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 107 110 mm diameter 108 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 109 a) coupler 110 110 mm 111 b) bend 87.5° 112 110 mm bend 113 electrical work 114 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 115 group c 116 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 117 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 118 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 119 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 120 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 121 2 x 1.5 sq. mm 122 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 123 25 mm 124 32 mm 125 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 126 100 mm x 100 mm x 60 mm deep 127 150 mm x 75 mm x 60 mm deep 128 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 129 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 130 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 131 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 132 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 133 6 way, double door 134 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 135 4 way (4 + 12), double door 136 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 137 single pole 138 single pole and neutral 139 triple pole 140 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 141 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 142 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 143 upto 450 mm sweep 144 supply of 15w surface mounted round led with all accessories as per standard item.. 145 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 146 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 147 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 148 supply of 30w led recess mounted fixturemake-philips cat no.rc380b led30s-6500 l60w60 psd od s1 or equivalent. 149 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 150 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 151 450 mm sweep 1400 rpm 152 staff qtrs type-iii . (24 nos. i.e. 6 blocks of four unit each) g+1 153 structural repair & retrofitting 154 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 155 50 mm average thickness 156 25 mm average thickness 157 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 158 bars upto 12 mm diameter 159 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 160 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 161 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 162 25mm thick in grade m 25 with cement content not less than 330 kg per cum 163 50mm thick in grade m 25 with cement content not less than 330 kg per cum 164 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 165 repairs to roof 166 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 167 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 168 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 169 repair to toilets 170 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 171 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 172 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 173 providing and fixing ist quality glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 174 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. this layer will be allowed to air cure for 4 hours. b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 175 providing and filling of cinder in sunken portions. 176 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 177 75 to 80 mm dia pipe 178 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 179 15 mm to 40 mm nominal bore 180 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 181 up to 150 mm diameter 182 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 183 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 184 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 185 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 186 up to 150 mm diameter 187 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 188 rectangular manhole 90x80 cm and 45 cm deep 189 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 190 110 mm diameter 191 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 192 a) coupler 193 110 mm 194 b) bend 87.5° 195 110 mm bend 196 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 197 75 mm diameter pipes 198 100 mm diameter pipes 199 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 200 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 201 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 202 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 203 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 204 kitchen sink without drain board 205 610x510 mm bowl depth 200 mm 206 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 207 a) 32mm dia (for wash basin) 208 b) 40mm dia (for sink and urinal) 209 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 210 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 211 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 212 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 213 waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 214 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 215 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 216 110 mm dia (wall thickness - 3.2 to 3.8 mm) 217 75 mm dia (wall thickness - 3.2 to 3.8 mm) 218 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 219 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 220 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 221 p-trap type floor trap 110 x 75 mm 222 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 223 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 224 providing and fixing 100 mm sand cast iron grating for gully trap. 225 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 226 providing & fixing soil, waste and vent pipes. 227 a) 100mm dia centrifugally cast iron s & s pipe. 228 b)75mm dia centrifugally cast iron s & s pipe. 229 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 230 a) for 100mm dia pipe. 231 b) for 75mm dia pipe. 232 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 233 a) 100mm 234 sand cast iron s&s as per is - 3989 235 b) 75mm 236 sand cast iron s&s as per is- 3989 237 providing and fixing plaincast iron s & s sanitary bend. 238 a) 100mm 239 sand cast iron s&s as per is - 1729 240 b) 75mm 241 sand cast iron s&s as per is - 3989 242 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 243 a) 100x100x100mm 244 b) 75x75x75mm 245 providing and fixingcast iron terminal guard. 246 a) 100mm 247 b) 75mm 248 providing & fixingcast iron coller. 249 a)100 mm 250 sand cast iron s&s as per is - 3989 251 b)75mm dia. 252 sand cast iron s&s as per is - 3989 253 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 254 a) 100mm 255 b) 75mm 256 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 257 a) 100mm inlet & 75mm outlet. 258 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 259 15 mm nominal outer dia pipes 260 20 mm nominal outer dia pipes 261 25 mm nominal outer dia pipes 262 32 mm nominal outer dia pipes 263 providing and fixing brass stop cock of approved quality. 264 15 mm nominal bore 265 providing and fixing gun metal gate valve with wheel of approved quality. 266 a) 25mm dia nominal bore 267 b) 32mm dia nominal bore 268 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 269 a) 25mm. nominal bore 270 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 271 a) 15mm nominal bore 272 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 273 a) 15mm nominal bore 274 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 275 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 276 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 277 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 278 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 279 providing & fixing cp brass bib cock of approved quality conforming to is 8931 280 a) 15mm nominal bore 281 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 282 a) 15mm nominal bore 283 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 284 a) 15mm nominal bore 285 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 286 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 287 25mm nominal bore, weighing not less than 62 gms 288 cutting holes up to 30x30 cm in walls including making good the same: 289 with common burnt clay f.p.s. (non modular) bricks 290 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 291 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 292 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 293 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 294 repair to plaster and plinth protection 295 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 296 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 297 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 298 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 299 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 300 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 301 with cement mortar 1:4 (1cement: 4 coarse sand) 302 12mm cement plaster of mix : 303 1:6 (1 cement : 6 course sand) 304 6mm cement plaster to ceiling of mix : 305 1:3 ( 1 cement : 3 fine sand) 306 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 307 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 308 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 309 old work (one or more coats) 310 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 311 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 312 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 313 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 314 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 315 repairs to door / windows 316 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 317 of area 3 sq. metres and below 318 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 319 of area 3 sq. metres and below 320 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 321 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 322 renewal of old putty of glass panes (length) 323 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 324 35 mm thick including isi marked stainless steel butt hinges with necessary screws 325 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 326 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 327 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 328 300 mm weighing not less than 200gms. 329 250 mm weighing not less than 150gms. 330 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 331 100x58x1.90 mm 332 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 333 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 334 300 x 10mm 335 150 x 10mm 336 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.granite stone slab colour black, cherry/ruby red area of slab upto 0.50 sqm. 337 providing and fixing to existing door frames. 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (puf)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 338 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 339 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 340 with isi marked stainless steel butt hinges of required size 341 kiln seasoned and chemically treated hollock wood 342 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 343 with 12 mm mild steel u beading 344 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 345 125 mm 346 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 347 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 348 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 349 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 350 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 351 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 352 4.0 mm thick glass panes 353 applying priming coat : 354 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 355 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 356 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 357 two or more coats on new work 358 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 359 one or more coats on old work 360 flooring 361 miscellaneous 362 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 363 cement mortar 1:6 (1 cement : 6 coarse sand) 364 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 365 cement mortar 1:4 (1 cement :4 coarse sand 366 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 367 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 368 electrical work 369 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 370 group b 371 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 372 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 373 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 374 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 375 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 376 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 377 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 378 group b 379 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 380 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 381 2 x 1.5 sq. mm 382 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 383 25 mm 384 32 mm 385 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 386 100 mm x 100 mm x 60 mm deep 387 150 mm x 75 mm x 60 mm deep 388 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 389 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 390 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 391 s/f light plug point modular type accessories :- 392 supply and fixing of suitable size gi box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 393 s/f power plug point modular type accessories :- 394 supply and fixing of suitable size gi box with modular plate and cover in frlsont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 395 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 396 supplying and fixing brass batten/ angle holder including connection etc. as required. 397 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 398 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 399 6 way, double door 400 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 401 4 way (4 + 12), double door 402 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 403 single pole 404 single pole and neutral 405 triple pole 406 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 407 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 408 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 409 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 410 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 411 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 412 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 413 supply of 15w surface mounted round led with all accessories as per standard item.. 414 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 415 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 416 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 417 cost of staff qtrs type-iii . (2 blocks of 2 unit each) g 418 structural repair & retrofitting 419 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 420 50 mm average thickness 421 25 mm average thickness 422 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 423 bars upto 12 mm diameter 424 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 425 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 426 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 427 25mm thick in grade m 25 with cement content not less than 330 kg per cum 428 50mm thick in grade m 25 with cement content not less than 330 kg per cum 429 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 430 repairs to roof 431 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 432 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 433 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 434 repair to toilets 435 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 436 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 437 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 438 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. size of tile 600 x 600 mm 439 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 440 75 to 80 mm dia pipe 441 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 442 15 mm to 40 mm nominal bore 443 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 444 up to 150 mm diameter 445 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 446 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 447 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 448 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 449 up to 150 mm diameter 450 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 451 rectangular manhole 90x80 cm and 45 cm deep 452 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 453 110 mm diameter 454 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 455 a) coupler 456 110 mm 457 b) bend 87.5° 458 110 mm bend 459 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 460 75 mm diameter pipes 461 100 mm diameter pipes 462 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 463 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 464 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 465 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 466 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 467 kitchen sink without drain board 468 610x510 mm bowl depth 200 mm 469 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 470 a) 32mm dia (for wash basin) 471 b) 40mm dia (for sink and urinal) 472 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 473 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 474 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 475 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 476 waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 477 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 478 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 479 110 mm dia (wall thickness - 3.2 to 3.8 mm) 480 75 mm dia (wall thickness - 3.2 to 3.8 mm) 481 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 482 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 483 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 484 p-trap type floor trap 110 x 75 mm 485 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 486 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 487 providing and fixing 100 mm sand cast iron grating for gully trap. 488 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 489 providing & fixing soil, waste and vent pipes. 490 a) 100mm dia centrifugally cast iron s & s pipe. 491 b)75mm dia centrifugally cast iron s & s pipe. 492 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 493 a) for 100mm dia pipe. 494 b) for 75mm dia pipe. 495 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 496 a) 100mm 497 sand cast iron s&s as per is - 3989 498 b) 75mm 499 sand cast iron s&s as per is- 3989 500 providing and fixing plaincast iron s & s sanitary bend. 501 a) 100mm 502 sand cast iron s&s as per is - 1729 503 b) 75mm 504 sand cast iron s&s as per is - 3989 505 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 506 a) 100x100x100mm 507 b) 75x75x75mm 508 providing and fixingcast iron terminal guard. 509 a) 100mm 510 b) 75mm 511 providing & fixingcast iron coller. 512 a)100 mm 513 sand cast iron s&s as per is - 3989 514 b)75mm dia. 515 sand cast iron s&s as per is - 3989 516 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 517 a) 100mm 518 b) 75mm 519 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 520 a) 100mm inlet & 75mm outlet. 521 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 522 15 mm nominal outer dia pipes 523 20 mm nominal outer dia pipes 524 25 mm nominal outer dia pipes 525 32 mm nominal outer dia pipes 526 providing and fixing brass stop cock of approved quality. 527 15 mm nominal bore 528 providing and fixing gun metal gate valve with wheel of approved quality. 529 a) 25mm dia nominal bore 530 b) 32mm dia nominal bore 531 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 532 a) 25mm. nominal bore 533 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 534 a) 15mm nominal bore 535 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 536 a) 15mm nominal bore 537 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 538 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 539 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 540 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 541 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 542 providing & fixing cp brass bib cock of approved quality conforming to is 8931 543 a) 15mm nominal bore 544 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 545 a) 15mm nominal bore 546 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 547 a) 15mm nominal bore 548 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 549 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 550 25mm nominal bore, weighing not less than 62 gms 551 cutting holes up to 30x30 cm in walls including making good the same: 552 with common burnt clay f.p.s. (non modular) bricks 553 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 554 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 555 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 556 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 557 repair to plaster and plinth protection 558 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 559 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 560 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 561 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 562 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 563 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 564 with cement mortar 1:4 (1cement: 4 coarse sand) 565 12mm cement plaster of mix : 566 1:6 (1 cement : 6 course sand) 567 6mm cement plaster to ceiling of mix : 568 1:3 ( 1 cement : 3 fine sand) 569 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 570 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 571 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 572 old work (one or more coats) 573 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 574 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 575 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 576 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 577 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 578 repairs to door / windows 579 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 580 of area 3 sq. metres and below 581 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 582 of area 3 sq. metres and below 583 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 584 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 585 renewal of old putty of glass panes (length) 586 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 587 35 mm thick including isi marked stainless steel butt hinges with necessary screws 588 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 589 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 590 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 591 300 mm weighing not less than 200gms. 592 250 mm weighing not less than 150gms. 593 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 594 100x58x1.90 mm 595 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 596 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 597 300 x 10mm 598 150 x 10mm 599 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.granite stone slab colour black, cherry/ruby red area of slab upto 0.50 sqm. 600 providing and fixing to existing door frames. 601 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 602 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 603 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 604 with isi marked stainless steel butt hinges of required size 605 kiln seasoned and chemically treated hollock wood 606 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 607 with 12 mm mild steel u beading 608 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 609 125 mm 610 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 611 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 612 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 613 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 614 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 615 4.0 mm thick glass panes 616 applying priming coat : 617 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 618 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 619 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 620 two or more coats on new work 621 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 622 one or more coats on old work 623 flooring 624 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 625 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 626 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 627 25 mm thick 628 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 629 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x 600 mm 630 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x 600 mm 631 miscellaneous 632 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 633 cement mortar 1:6 (1 cement : 6 coarse sand) 634 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 635 cement mortar 1:4 (1 cement :4 coarse sand 636 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 637 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 638 electrical work of type-iii (g) 639 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 640 group b 641 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 642 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 643 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 644 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 645 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 646 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 647 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 648 group b 649 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 650 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 651 2 x 1.5 sq. mm 652 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 653 25 mm 654 32 mm 655 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 656 100 mm x 100 mm x 60 mm deep 657 150 mm x 75 mm x 60 mm deep 658 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 659 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 660 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 661 s/f light plug point modular type accessories :- 662 supply and fixing of suitable size gi box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 663 s/f power plug point modular type accessories :- 664 supply and fixing of suitable size gi box with modular plate and cover in frlsont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 665 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 666 supplying and fixing brass batten/ angle holder including connection etc. as required. 667 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 668 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 669 6 way, double door 670 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 671 4 way (4 + 12), double door 672 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 673 single pole 674 single pole and neutral 675 triple pole 676 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 677 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 678 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 679 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 680 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 681 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 682 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 683 supply of 15w surface mounted round led with all accessories as per standard item.. 684 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 685 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 686 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 687 type - 4 688 structural repair & retrofitting 689 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 690 50 mm average thickness 691 25 mm average thickness 692 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 693 bars upto 12 mm diameter 694 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 695 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 696 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 697 25mm thick in grade m 25 with cement content not less than 330 kg per cum 698 50mm thick in grade m 25 with cement content not less than 330 kg per cum 699 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 700 repairs to roof 701 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 702 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 703 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 704 repair to toilets 705 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 706 for thickness of tiles 10 mm to 25 mm 707 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. glazed vitrified floor tiles polished finish of sizesize of tile 600 x 600 mm 708 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 709 75 to 80 mm dia pipe 710 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 711 15 mm to 40 mm nominal bore 712 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 713 up to 150 mm diameter 714 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 715 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 716 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 717 dismantling of flushing cistern of all types (c.i./pvc/vitrious china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 718 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 719 up to 150 mm diameter 720 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 721 rectangular manhole 90x80 cm and 45 cm deep 722 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 723 110 mm diameter 724 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 725 a) coupler 726 110 mm 727 b) bend 87.5° 728 110 mm bend 729 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 730 75 mm diameter pipes 731 100 mm diameter pipes 732 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 733 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 734 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : 735 w.c. pan with isi marked white solid plastic seat and lid 736 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 737 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 738 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 739 kitchen sink without drain board 740 610x510 mm bowl depth 200 mm 741 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 742 a) 32mm dia (for wash basin) 743 b) 40mm dia (for sink and urinal) 744 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 745 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 746 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 747 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 748 providing & fixing c.p. brass waste coupling for pvc waste pipe. 749 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 750 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 751 110 mm dia (wall thickness - 3.2 to 3.8 mm) 752 75 mm dia (wall thickness - 3.2 to 3.8 mm) 753 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 754 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 755 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 756 p-trap type floor trap 110 x 75 mm 757 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 758 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 759 providing and fixing 100 mm sand cast iron grating for gully trap. 760 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 761 providing & fixing soil, waste and vent pipes. 762 a) 100mm dia centrifugally cast iron s & s pipe. 763 b)75mm dia centrifugally cast iron s & s pipe. 764 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 765 a) for 100mm dia pipe. 766 b) for 75mm dia pipe. 767 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 768 a) 100mm 769 sand cast iron s&s as per is - 3989 770 b) 75mm 771 sand cast iron s&s as per is- 3989 772 providing and fixing plaincast iron s & s sanitary bend. 773 a) 100mm 774 sand cast iron s&s as per is - 1729 775 b) 75mm 776 sand cast iron s&s as per is - 3989 777 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 778 a) 100x100x100mm 779 b) 75x75x75mm 780 providing and fixingcast iron terminal guard. 781 a) 100mm 782 b) 75mm 783 providing & fixingcast iron coller. 784 a)100 mm 785 sand cast iron s&s as per is - 3989 786 b)75mm dia. 787 sand cast iron s&s as per is - 3989 788 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 789 a) 100mm 790 b) 75mm 791 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 792 a) 100mm inlet & 75mm outlet. 793 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 794 15 mm nominal outer dia pipes 795 20 mm nominal outer dia pipes 796 25 mm nominal outer dia pipes 797 32 mm nominal outer dia pipes 798 providing and fixing brass stop cock of approved quality. 799 15 mm nominal bore 800 providing and fixing gun metal gate valve with wheel of approved quality. 801 a) 25mm dia nominal bore 802 b) 32mm dia nominal bore 803 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 804 a) 25mm. nominal bore 805 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 806 a) 15mm nominal bore 807 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 808 a) 15mm nominal bore 809 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 810 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 811 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 812 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 813 providing & fixing cp brass bib cock of approved quality conforming to is 8931 814 a) 15mm nominal bore 815 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 816 a) 15mm nominal bore 817 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 818 a) 15mm nominal bore 819 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 820 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 821 25mm nominal bore, weighing not less than 62 gms 822 cutting holes up to 30x30 cm in walls including making good the same: 823 with common burnt clay f.p.s. (non modular) bricks 824 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 825 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 826 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 827 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 828 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 829 repair to plaster and plinth protection 830 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 831 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 832 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 833 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 834 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 835 with cement mortar 1:4 (1cement: 4 coarse sand) 836 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 837 15mm cement plaster on rough side of single or half brick wall of mix 838 1:6 (1 cement : 6 course sand) 839 6mm cement plaster to ceiling of mix : 840 1:3 ( 1 cement : 3 fine sand) 841 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 842 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 843 distempering with 1st quality acrylic distemper (ready made) having voc content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturers specification. 844 one or more coats on old work 845 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 846 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 847 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 848 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 849 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 850 repairs to door / windows 851 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 852 of area 3 sq. metres and below 853 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 854 of area 3 sq. metres and below 855 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 856 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 857 renewal of old putty of glass panes (length) 858 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 859 35 mm thick including isi marked stainless steel butt hinges with necessary screws 860 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 861 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete fixed to steel windows by welding 862 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 863 300 mm weighing not less than 200gms. 864 250 mm weighing not less than 150gms. 865 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 866 100x58x1.90 mm 867 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 868 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 869 300 x 10mm 870 150 x 10mm 871 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 872 125 mm 873 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 874 twin rubber stopper 875 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.granite stone slab colour black, cherry/ruby red area of slab upto 0.50 sqm. 876 providing and fixing to existing door frames. 877 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, castedmonolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 878 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 879 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 880 with isi marked stainless steel butt hinges of required size 881 kiln seasoned and chemically treated hollock wood 882 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 883 with 12 mm mild steel u beading 884 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 885 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 886 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 887 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 888 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 889 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 890 4.0 mm thick glass panes 891 applying priming coat : 892 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 893 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 894 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 895 over an under coat of suitableshadewithordinarypaint of approved brand and manufacture 896 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 897 one or more coats on old work 898 repairs to flooring 899 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 900 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 901 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 902 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural ources) 903 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 904 25 mm thick 905 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 906 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 907 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x 600 mm 908 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x 600 mm 909 miscellaneous 910 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 911 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 912 cement mortar 1:6 (1 cement : 6 coarse sand) 913 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 914 cement mortar 1:4 (1 cement :4 coarse sand 915 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 916 electrical work of guest house 917 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 918 group b 919 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 920 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 921 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 922 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 923 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 924 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 925 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 926 group b 927 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 928 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 929 2 x 1.5 sq. mm 930 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 931 25 mm 932 32 mm 933 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 934 100 mm x 100 mm x 60 mm deep 935 150 mm x 75 mm x 60 mm deep 936 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 937 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 938 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 939 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 940 supplying and fixing brass batten/ angle holder including connection etc. as required. 941 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 942 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 943 6 way, double door 944 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 945 4 way (4 + 12), double door 946 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 947 single pole 948 single pole and neutral 949 triple pole 950 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 951 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 952 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 953 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 954 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 955 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 956 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 957 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 958 upto 450 mm sweep 959 supply of 15w surface mounted round led with all accessories as per standard item.. 960 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 961 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 962 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 963 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 964 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 965 300 mm sweep 1300 rpm 966 guest house 967 structural repair & retrofitting 968 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 969 50 mm average thickness 970 25 mm average thickness 971 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 972 bars upto 12 mm diameter 973 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 974 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 975 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 976 25mm thick in grade m 25 with cement content not less than 330 kg per cum 977 50mm thick in grade m 25 with cement content not less than 330 kg per cum 978 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 979 repairs to roof 980 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete. tear strength in longitudinal and transverse direction as 60/80n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick: 981 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 982 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 983 repair to toilets 984 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 985 for thickness of tiles 10 mm to 25 mm 986 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. glazed vitrified floor tiles polished finish of size size of tile 600 x 600 mm 987 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 988 75 to 80 mm dia pipe 989 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 990 15 mm to 40 mm nominal bore 991 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 992 up to 150 mm diameter 993 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 994 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 995 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 996 dismantling of flushing cistern of all types (c.i./pvc/vitrious china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 997 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 998 up to 150 mm diameter 999 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 1000 rectangular manhole 90x80 cm and 45 cm deep 1001 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1002 110 mm diameter 1003 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1004 a) coupler 1005 110 mm 1006 b) bend 87.5° 1007 110 mm bend 1008 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1009 75 mm diameter pipes 1010 100 mm diameter pipes 1011 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1012 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1013 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 1014 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 1015 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1016 kitchen sink without drain board 1017 610x510 mm bowl depth 200 mm 1018 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 1019 a) 32mm dia (for wash basin) 1020 b) 40mm dia (for sink and urinal) 1021 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 1022 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 1023 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 1024 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1025 providing & fixing c.p. brass waste coupling for pvc waste pipe. 1026 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 1027 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1028 110 mm dia (wall thickness - 3.2 to 3.8 mm) 1029 75 mm dia (wall thickness - 3.2 to 3.8 mm) 1030 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 1031 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 1032 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 1033 p-trap type floor trap 110 x 75 mm 1034 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 1035 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1036 providing and fixing 100 mm sand cast iron grating for gully trap. 1037 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 1038 providing & fixing soil, waste and vent pipes. 1039 a) 100mm dia centrifugally cast iron s & s pipe. 1040 b)75mm dia centrifugally cast iron s & s pipe. 1041 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 1042 a) for 100mm dia pipe. 1043 b) for 75mm dia pipe. 1044 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1045 a) 100mm 1046 sand cast iron s&s as per is - 3989 1047 b) 75mm 1048 sand cast iron s&s as per is- 3989 1049 providing and fixing plaincast iron s & s sanitary bend. 1050 a) 100mm 1051 sand cast iron s&s as per is - 1729 1052 b) 75mm 1053 sand cast iron s&s as per is - 3989 1054 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1055 a) 100x100x100mm 1056 b) 75x75x75mm 1057 providing and fixingcast iron terminal guard. 1058 a) 100mm 1059 b) 75mm 1060 providing & fixingcast iron coller. 1061 a)100 mm 1062 sand cast iron s&s as per is - 3989 1063 b)75mm dia. 1064 sand cast iron s&s as per is - 3989 1065 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1066 a) 100mm 1067 b) 75mm 1068 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1069 a) 100mm inlet & 75mm outlet. 1070 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1071 15 mm nominal outer dia pipes 1072 20 mm nominal outer dia pipes 1073 25 mm nominal outer dia pipes 1074 32 mm nominal outer dia pipes 1075 providing and fixing brass stop cock of approved quality. 1076 15 mm nominal bore 1077 providing and fixing gun metal gate valve with wheel of approved quality. 1078 a) 25mm dia nominal bore 1079 b) 32mm dia nominal bore 1080 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 1081 a) 25mm. nominal bore 1082 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 1083 a) 15mm nominal bore 1084 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 1085 a) 15mm nominal bore 1086 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1087 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 1088 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1089 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 1090 providing & fixing cp brass bib cock of approved quality conforming to is 8931 1091 a) 15mm nominal bore 1092 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1093 a) 15mm nominal bore 1094 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 1095 a) 15mm nominal bore 1096 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 1097 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 1098 25mm nominal bore, weighing not less than 62 gms 1099 cutting holes up to 30x30 cm in walls including making good the same: 1100 with common burnt clay f.p.s. (non modular) bricks 1101 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1102 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 1103 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 1104 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 1105 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1106 repair to plaster and plinth protection 1107 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1108 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1109 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1110 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1111 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 1112 with cement mortar 1:4 (1cement: 4 coarse sand) 1113 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1114 15mm cement plaster on rough side of single or half brick wall of mix 1115 1:6 (1 cement : 6 course sand) 1116 6mm cement plaster to ceiling of mix : 1117 1:3 ( 1 cement : 3 fine sand) 1118 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1119 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 1120 distempering with 1st quality acrylic distemper (ready made) having voc content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturers specification. 1121 one or more coats on old work 1122 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1123 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 1124 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1125 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 1126 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1127 repairs to door / windows 1128 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1129 of area 3 sq. metres and below 1130 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1131 of area 3 sq. metres and below 1132 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1133 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1134 renewal of old putty of glass panes (length) 1135 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1136 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1137 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1138 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete fixed to steel windows by welding 1139 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 1140 300 mm weighing not less than 200gms. 1141 250 mm weighing not less than 150gms. 1142 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1143 100x58x1.90 mm 1144 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1145 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1146 300 x 10mm 1147 150 x 10mm 1148 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1149 125 mm 1150 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 1151 twin rubber stopper 1152 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.granite stone slab colour black, cherry/ruby red area of slab upto 0.50 sqm. 1153 providing and fixing to existing door frames. 1154 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, castedmonolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 1155 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 1156 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 1157 with isi marked stainless steel butt hinges of required size 1158 kiln seasoned and chemically treated hollock wood 1159 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 1160 with 12 mm mild steel u beading 1161 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1162 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1163 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1164 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1165 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1166 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1167 4.0 mm thick glass panes 1168 applying priming coat : 1169 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 1170 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1171 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1172 over an under coat of suitableshadewithordinarypaint of approved brand and manufacture 1173 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1174 one or more coats on old work 1175 repairs to flooring 1176 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1177 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1178 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 1179 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural ources) 1180 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1181 25 mm thick 1182 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1183 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 1184 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x 600 mm 1185 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x 600 mm 1186 miscellaneous 1187 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 1188 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 1189 cement mortar 1:6 (1 cement : 6 coarse sand) 1190 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 1191 cement mortar 1:4 (1 cement :4 coarse sand 1192 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 1193 electrical work of guest house 1194 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 1195 group b 1196 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 1197 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 1198 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 1199 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 1200 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 1201 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 1202 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1203 group b 1204 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 1205 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 1206 2 x 1.5 sq. mm 1207 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1208 25 mm 1209 32 mm 1210 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1211 100 mm x 100 mm x 60 mm deep 1212 150 mm x 75 mm x 60 mm deep 1213 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1214 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 1215 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1216 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1217 supplying and fixing brass batten/ angle holder including connection etc. as required. 1218 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1219 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1220 6 way, double door 1221 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1222 4 way (4 + 12), double door 1223 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1224 single pole 1225 single pole and neutral 1226 triple pole 1227 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 1228 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1229 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1230 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 1231 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 1232 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 1233 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1234 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1235 upto 450 mm sweep 1236 supply of 15w surface mounted round led with all accessories as per standard item.. 1237 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1238 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1239 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1240 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00, air delivery minimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 1241 supplyof ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc.complete 1242 300 mm sweep 1300 rpm 1243 staff qtrs type-ii . 1244 structural repair & retrofitting 1245 chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of engineer-in-charge 1246 50 mm average thickness 1247 25 mm average thickness 1248 cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of engineer-in-charge. 1249 bars upto 12 mm diameter 1250 cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of engineer in charge. 1251 shotcreting r.c.c. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by engineerin- charge 1252 note: rates shall include the providing necessary ground wires etc. the levelling gauges, if used, shall be paid for separately. payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1253 25mm thick in grade m 25 with cement content not less than 330 kg per cum 1254 50mm thick in grade m 25 with cement content not less than 330 kg per cum 1255 re-baring of ms bar 10 mm dia with fisher chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of engineer-in-charge. 1256 repairs to roof 1257 providing and laying app (atactic polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°c, 0.87-0.89 kg/ litre and viscocity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc, and preparing the surface complete.the vital physical and chemical parameters of the membrane shall be as under : joint strength in longitudinal and transverse direction at 23°c as 650/ 450n/ 5cm. tear strength in longitudinal and transverse direction as 300/250n. softening point of membrane not less than 150°c. cold flexibility shall be upto -2°c when tested in accordance with astm, d - 5147. the laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1258 extra for covering top of membrane with geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by butane torch as per manufactures recommendation. 1259 grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1260 repair to toilets 1261 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1262 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1263 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/antiskid finish of size of tile 600 x 600 mm 1264 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. glazed vitrified floor tiles polished finish of size size of tile 600 x 600 mm 1265 dismantling c.i. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1266 75 to 80 mm dia pipe 1267 dismantling g.i. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer-in-charge : 1268 15 mm to 40 mm nominal bore 1269 dismantling c.i. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of engineer-in-charge: 1270 up to 150 mm diameter 1271 taking out c.i. cover with frame from r.c.c. top slab of manholes of various sizes including demolishing of r.c.c. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of engineer-in-charge. 1272 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1273 dismantling w.c. pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of engineer-in- charge. 1274 dismantling of c.i. sluice valve including stacking of useful materials within a lead of 50 metres 1275 up to 150 mm diameter 1276 dismantling of manhole including r.c.c. top slab, c.i. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of engineer- charge : 1277 rectangular manhole 90x80 cm and 45 cm deep 1278 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1279 110 mm diameter 1280 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1281 a) coupler 1282 110 mm 1283 b) bend 87.5° 1284 110 mm bend 1285 painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1286 75 mm diameter pipes 1287 100 mm diameter pipes 1288 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1289 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1290 providing & fixing white vitreous china wash basin with c.i. brackets painted white, 15mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mmc.p. brass waste of standard pattern including cutting & making good the walls wherever required. 1291 a)flat back wash basin size 550x400 mm with single 15mm c.p. brass pillar tap. 1292 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1293 kitchen sink without drain board 1294 610x510 mm bowl depth 200 mm 1295 providing and fixing flexible p.v.c. waste pipe for sink or wash basin including pvc waste fittings complete. 1296 a) 32mm dia (for wash basin) 1297 b) 40mm dia (for sink and urinal) 1298 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 1299 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 1300 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 1301 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1302 waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1303 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type-b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 1304 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1305 110 mm dia (wall thickness - 3.2 to 3.8 mm) 1306 75 mm dia (wall thickness - 3.2 to 3.8 mm) 1307 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 1308 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 1309 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 1310 p-trap type floor trap 110 x 75 mm 1311 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 1312 providing & fixing of ss floor cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1313 providing and fixing 100 mm sand cast iron grating for gully trap. 1314 providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with c.p. brass screws and washers. 1315 providing & fixing soil, waste and vent pipes. 1316 a) 100mm dia centrifugally cast iron s & s pipe. 1317 b)75mm dia centrifugally cast iron s & s pipe. 1318 providing & fixing m.s. holder bat clamps of approved design to sand cast iron/centrifugally cast (spun) iron s & s pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).including cost of cutting holes & making good the walls etc. 1319 a) for 100mm dia pipe. 1320 b) for 75mm dia pipe. 1321 providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1322 a) 100mm 1323 sand cast iron s&s as per is - 3989 1324 b) 75mm 1325 sand cast iron s&s as per is- 3989 1326 providing and fixing plaincast iron s & s sanitary bend. 1327 a) 100mm 1328 sand cast iron s&s as per is - 1729 1329 b) 75mm 1330 sand cast iron s&s as per is - 3989 1331 providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1332 a) 100x100x100mm 1333 b) 75x75x75mm 1334 providing and fixingcast iron terminal guard. 1335 a) 100mm 1336 b) 75mm 1337 providing & fixingcast iron coller. 1338 a)100 mm 1339 sand cast iron s&s as per is - 3989 1340 b)75mm dia. 1341 sand cast iron s&s as per is - 3989 1342 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1343 a) 100mm 1344 b) 75mm 1345 providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1346 a) 100mm inlet & 75mm outlet. 1347 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1348 15 mm nominal outer dia pipes 1349 20 mm nominal outer dia pipes 1350 25 mm nominal outer dia pipes 1351 32 mm nominal outer dia pipes 1352 providing and fixing brass stop cock of approved quality. 1353 15 mm nominal bore 1354 providing and fixing gun metal gate valve with wheel of approved quality. 1355 a) 25mm dia nominal bore 1356 b) 32mm dia nominal bore 1357 providing and fixing ball valve (brass) of approved quality complete.(high or low pressure with plastic floats). 1358 a) 25mm. nominal bore 1359 providing and fixing 30 cm long unplasticised pvc connection pipe with brass unions. 1360 a) 15mm nominal bore 1361 providing and fixing 45 cm long unplasticised pvc connection pipe with brass unions. 1362 a) 15mm nominal bore 1363 constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with c. i. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1364 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 1365 constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with c.i. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and rcc top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1366 with common burnt clay f.p.s.(non modular) bricks ofclass designation 7.5 1367 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1368 providing & fixing cp brass bib cock of approved quality conforming to is 8931 1369 a) 15mm nominal bore 1370 providing & fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1371 a) 15mm nominal bore 1372 providing & fixing c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is 8931 1373 a) 15mm nominal bore 1374 providing and fixing c.p. brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of engineer-in-charge. 1375 providing and fixing ptmt extension nipple for water tank pipe, fittings of approved quality and colour. 1376 25mm nominal bore, weighing not less than 62 gms 1377 cutting holes up to 30x30 cm in walls including making good the same: 1378 with common burnt clay f.p.s. (non modular) bricks 1379 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1380 making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing g.i. pipe etc. 1381 raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole to be paid separately) : 1382 rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade ld - 2.5 1383 providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1384 repair to plaster and plinth protection 1385 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1386 nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1387 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1388 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1389 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1390 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of engineer-in-charge. 1391 with cement mortar 1:4 (1cement: 4 coarse sand) 1392 12mm cement plaster of mix : 1393 1:6 (1 cement : 6 course sand) 1394 6mm cement plaster to ceiling of mix : 1395 1:3 ( 1 cement : 3 fine sand) 1396 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1397 new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre 1398 distempering with 1st quality acrylic distemper (ready mixed) having voc (volatile organic compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 old work (one or more coats) 1399 old work (one or more coats) 1400 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1401 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 1402 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1403 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade 1404 old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1405 repairs to door / windows 1406 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1407 of area 3 sq. metres and below 1408 taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1409 of area 3 sq. metres and below 1410 renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1411 float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1412 renewal of old putty of glass panes (length) 1413 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1414 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1415 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1416 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coatwith approved steel primer all complete. fixed to steel windows by welding 1417 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete 1418 300 mm weighing not less than 200gms. 1419 250 mm weighing not less than 150gms. 1420 providing and fixing is : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1421 100x58x1.90 mm 1422 providing & fixing stainless steel sliding door bolts isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1423 providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1424 300 x 10mm 1425 150 x 10mm 1426 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.granite stone slab colour black, cherry/ruby red area of slab upto 0.50 sqm. 1427 providing and fixing to existing door frames. 1428 30 mm thick fiberglass reinforced plastic (f.r.p.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick frp laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam puf)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of f.r.p. laminate conforming to table - 3 of is: 14856, complete as per direction of engineer-in-charge. 1429 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 1430 30 mm thick shutterswith isi marked m.s. butt hinges with necessary screws 1431 with isi marked stainless steel butt hinges of required size 1432 kiln seasoned and chemically treated hollock wood 1433 providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 1434 with 12 mm mild steel u beading 1435 providing and fixing bright /matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1436 125 mm 1437 providing and fixing t-iron frames for doors, windows and ventilators of mild steel tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1438 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1439 fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1440 providing and fixing m.s. tubular frames for doors, windows, ventilators and cupboard with rectangular/ l-type sections, made of 1.60 mm thick m.s. sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1441 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1442 providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1443 4.0 mm thick glass panes 1444 applying priming coat : 1445 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1446 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1447 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1448 two or more coats on new work 1449 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1450 one or more coats on old work 1451 flooring 1452 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 1453 nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1454 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1455 25 mm thick 1456 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1457 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x 600 mm 1458 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x 600 mm 1459 miscellaneous 1460 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : 1461 cement mortar 1:6 (1 cement : 6 coarse sand) 1462 half brick masonry with common burnt clay f.p.s. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor v level. 1463 cement mortar 1:4 (1 cement :4 coarse sand 1464 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 1465 providing and fixing 16 mm m.s. fan clamps of standard shape and size in existing r.c.c. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 1466 electrical work of type-ii (g) 1467 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc as required. 1468 group b 1469 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. 1470 wiring for light/ power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no 4 sq. mm fr pvc insulated copper conductor single core cable for loop earthing as required. 1471 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 1472 2x1.5 sq. mm + 1 x 1.5 sq. mm earth wire 1473 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 1474 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 1475 rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable and 1.5 sq.mm. fr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1476 group b 1477 rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required. 1478 supplying and drawing following sizes of fr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 1479 2 x 1.5 sq. mm 1480 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1481 25 mm 1482 32 mm 1483 supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1484 100 mm x 100 mm x 60 mm deep 1485 150 mm x 75 mm x 60 mm deep 1486 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1487 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 1488 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1489 s/f light plug point modular type accessories :- 1490 supply and fixing of suitable size gi box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 1491 s/f power plug point modular type accessories :- 1492 supply and fixing of suitable size gi box with modular plate and cover in frlsont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 1493 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1494 supplying and fixing brass batten/ angle holder including connection etc. as required. 1495 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1496 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1497 6 way, double door 1498 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1499 4 way (4 + 12), double door 1500 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1501 single pole 1502 single pole and neutral 1503 triple pole 1504 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 1505 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1506 earthing with g.i. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1507 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re-filling as required. 1508 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 1509 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 1510 installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1511 supply of 15w surface mounted round led with all accessories as per standard item.. 1512 supply of 20w surface mounted round led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1513 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1514 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1515 sewerage system 1516 excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : 1517 all kinds of soil 1518 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 1519 pipes, cables exceeding 300 mm dia but not exceeding 600 mm dia 1520 providing and laying non-pressure np2 class (light duty) r.c.c. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 1521 150 mm dia. r.c.c. pipe 1522 450 mm dia. r.c.c. pipe 1523 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-iii): 10 graded stone aggregate 40 mm nominal size) 1524 150 mm diameter s.w.pipe (l*.35*.10) 1525 450 mm diameter s.w.pipe (l*.6*.15 ) 1526 constructing brick masonry manholein cement mortar 1 : 4 (1 cement : 4 coarse sand) with rcc top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4gradestone aggregate 20mm nominal size); foundation concrete 1:4:8 mix(1 cement : 4 coarse sand : 8 gradedstoneaggregate40 mm nominalsize) insideplastering 12 mm thickwith cementmortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and makingchannels incementconcrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat ofneatcement completeasper standard design 1527 inside size 90 x 80 cm & 45 cmdeep including ci cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover & frame to be not lessthan 38 kg (weight of cover 23 kg and weight of frame 15 kg) 1528 with common burnt clay f.p.s.(non modular) bricks of classic designation 7.5 1529 extra for depth for manholes: 1530 size 90 x 80 cm 1531 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 1532 constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top with fps bricksclass designation 75in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand :6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. 1533 0.91m deep with sfrc cover and frame (heavy duty hd-20 grade designation) 560mm internal diameter conforming to i.s:12592, total weight of cover and frame to be not less than 182kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) 1534 with common burnt clay f.p.s.(non module) brick of class designation 7.5 1535 extra depth for circuler type manholes 0.91 m internal dia ( at bottom ) beyond 0.91m to 1.67 m . 1536 with common burnt clay f.p.s.(non module) brick of class designation 7.5 1537 providing and fixing square mouths. w. gully trapclass sp-1 complete with c.i. gratingbrickmasonry chamber with water tight ci cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 1538 180 x 150 mm. size p type 1539 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 1540 providing m.s. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 1541 with 20x20 mm square bar 1542 cleaning of chocked sewer line by diesel running vehicle mountinghydraulic operated high pressure suction cum jetting sewer cleaningmachine fitted with pump having 4000 litres suction capacity and6000 litres water jetting tank capacity including skilled operator,supervising engineer etc. for cleaning and partial desilting of manholesand dechocking of sewer lines. dechocking and flushing of sewerline from one manhole to another by high pressure jetting system of2200 psi for sewer line from 150mm dia upto 300mm 1543 cleaning and desilting of gully trap chamber, including removal ofrubbish mixed with earth etc. and disposal of same, all as per thedirection of engineer-in-charge. 1544 septic tank 1545 size of tank = 5.00 x 2.00 x 1.24 mtr 1546 excavation work by mechanical means (hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. 1547 all kinds soil 1548 take 50 % qty of items 1.a 1549 ordinary rock 1550 take 50 % qty of items 1.a 1551 excavation work by mechanical means (hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. 1552 earth work in excavation 1.50-3.00 mtr 1553 all kinds soil 1554 take 50 % qty of items 2.a 1555 ordinary rock 1556 take 50 % qty of items 2.a 1557 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 1558 20 % of excavation of items (1.a.1+2.a.1) 1559 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 1560 1:5:10 (1 cement : 5 coarse sand (zone-iii): 10 graded stone aggregate 40 mm nominal size). 1561 providing and laying in position machine batched and machine mixed design mix m-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer-in-charge.“(note :- cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 1562 upto plinth level 1563 centering and shuttering including strutting, propping etc. and removal of form for: 1564 foundations, footings, bases of columns, etc. for mass concrete. 1565 walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 1566 lintels, beams, plinth beams, girders, bressumers and cantilevers. 1567 rcc bend beam 1568 suspended floors, roofs, landings, balconies and access platform. 1569 edges of slabs and breaks in floors and walls. 1570 under 20 cm wide 1571 providing and fixing tie bolt, spring coil and plastic cone in wall shuttering complete as per the direction of engineer-in-charge. 1572 reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete. 1573 thermo-mechanically treated bars. 1574 up to plinth 1575 52 mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume. hardening compound is mixed @ 2 litre per 50kg of cement or as per manufactures specifications. this includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 1576 for maintaining slope 1577 6 mm cement plaster on rough side of single or half brick wall of mix: 1578 1:3 (1 cement: 3 fine sand) 1579 providing and fixing in position pre-cast r.c.c. manhole cover and frame of required shape and approved quality 1580 hd-20 1581 circular shape 560 mm internal diameter 1582 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910 on 12mm dia steel bar conforming to is : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 1583 providing and fixing soil, waste and vent pipes 1584 100 mm dia. 1585 centrifugally cast (spun) iron socketed pipe as per is: 3989. 1586 providing and fixing terminal guard : 1587 100 mm 1588 sand cast iron s&s as per is - 3989 1589 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and s.w. drain pipe 100 mm diameter, 1.8m long complete as per standard design.with f.p.s. bricks 1590 estimate of externalelectrical works 1591 subhead - i - main boards 1592 meter boards 1593 supply, installation, testing and commissioning of m.v. cubical type totally enclosed dust, dump and vermin proof meter bords complete with bus bars, mv danger notice plate, on surface isi marked electronic kwh meter, indication lamps, cts, interconnection with suitable capacity aluminium strips / rods, door covers, seperate compartment for each meter, glass inspection window, connection of incoming and outgoing cables with thimbles, powder coated having following incoming and outgoingmcbs mccbs and kwh meters complete as required. 1594 meter boards - type-iii (6 nos) & warden residence ( 2 nos) & type-ii(1nos) 1595 incomer 1596 1 no.63 amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 1597 metering & indication 1598 1 set of r,y,b phase indicating lamps 1599 digital multifunction meter for voltage, current & kw with selector switch. each with 3nos. of 2a sp mcb & 3nos 63/5a cts (63a/500v) rating 1600 1 sets of breaker on-off-trip, spring charged indication lamps as required. 1601 bus-bar 1602 1 set of 100a tpn aluminium bus bar with colour coded pvc sleeves 1603 out going: 1604 4 nos. 40a tpn mcb of 10ka 1605 2 nos. 40a dp mcb of 10ka. 1606 supplying,receiving, fixing, testing & commissioning ofabove described panel 1607 meter boards - principle residence & guest house. 1608 1 no.40amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 1609 panel -mp hall 1610 incomer 1611 1 no.63 amp fp mccb, 15 ka breaking capacity with thermal release and adjustable setting and with rotary handle. 1612 metering & indication 1613 1 set of r,y,b phase indicating lamps 1614 digital multifunction meter for voltage, current & kw with selector switch. each with 3nos. of 2a sp mcb & 3nos 63/5a cts (63a/500v) rating 1615 1 sets of breaker on-off-trip, spring charged indication lamps as required. 1616 bus-bar 1617 1 set of 100a tpn aluminium bus bar with colour coded pvc sleeves 1618 out going: 1619 4 nos. 40a tpn mcb of 10ka 1620 3 no. 40a dp mcb of 10ka. 1621 supplying,receiving, fixing, testing & commissioning ofabove described panel 1622 subhead - ii - earthing 1623 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 1624 earthing with cu. earth plate 600mm x 600mm x 3mm thick includingaccesssories, and providingmasonary enclosurewith cover plate (ci heavy duty) having locking arrangement and watering pipe pipe of 2.7 mtr long etc. with charcoal or coke and salt) as required. 1625 supplying and laying 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode, including connection with g.i. nut, bolt, spring, washer excavation and refilling etc. as required. 1626 providing and fixing 25 mm x 5 mm copper strip in 40 mm dia g.i. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. 1627 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required.
  • View Tender
  • Document
  • Bid Support
2 Security Services
image image
Central Government/Public Sector
TRN :49054604 |  13 Jun, 2025
Tender Value : 70.50 Crore
 Kochi - Goa
Tender for tender for provision of cgsd (kochi) at willingdon island, kochi; 1 schedule a part - i (building & structure works)details of prepriced schedule is given in tender documents. 2 schedule a part-ii ( site clearence/development & earth works) details of prepriced schedule is given in tender documents. 3 schedule a part-iii (internal water supply) details of prepriced schedule is given in tender documents. 4 schedule a part-iv (internal electrification) details of prepriced schedule is given in tender documents. 5 schedule a part-v (fire fighting)details of prepriced schedule is given in tender documents. 6 schedule a part-vi (road/path/ hard standing/culvert)details of prepriced schedule is given in tender documents. 7 schedule a part-vii (external water supply) details of prepriced schedule is given in tender documents. 8 schedule a part-viii (external electrification) details of prepriced schedule is given in tender documents. 9 schedule a part-ix (sewage disposal) details of prepriced schedule is given in tender documents. 10 schedule a part-x (area drainage) details of prepriced schedule is given in tender documents. 11 schedule a part-xi (compound wall) details of prepriced schedule is given in tender documents. 12 schedule a part-xii (organic waste converter and smart energy meter) details of prepriced schedule is given in tender documents. 13 schedule a part -xiii (miscellanious items) note:- this schedule is not pre-priced by mes and the pre-priced rate indicated as rs 0.00 under col. e signifies this fact only. 14 internal water supply s & f for 15 mm dia bore cp two way bib cock with cp wall flange (make : jaquar model no. opp15041pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 15 s & f for 15 mm dia bore cp bib cock with cp wall flange (make : jaquar model no. opp15037pm / eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 16 s & f for 20 mm bore concealed stop cock reqular brass body with spindle extnwith exposed part kit of concealed stop cock with fitting sleeve, operating lever & adjustable wall flange (compatible with ald-083cqt & ald-089cqt)(make : jaquar model no. ald 089 cqt/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 17 s & f for 25 mm dia bore concealed stop cock reqular brass body with spindle extn with flush cock & wall flange 25mm ceramic disc cartridge) with plain knob (make : jaquar model no. ald 081/ eqvlt in kohler/grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for cpvc pipes or for union and fixed complete all as specified and directed by engr-in-charge. 18 s & f 20mm bore cp angular stop cock with cp wall flange (make : jaquar model no. cqt 23053 / eqvlt in kohler/grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 s & f for 100 mm overhead shower rose round shape single flow (abs body chrome plated with gray face plate (make : jaquar model no. 1989 with sha 479l300s / eqvlt in kohler/ ess ess) with shower arm ø20mm & 300mm long round shape with 90° bend for wall mounted showers with stainless steel connected to pipe complete all as specified and directed by engr-in-charge. 20 cooling appliancesdesign, supply, installation, testing and commissioning of invertor type floor mounted packaged ac units of specified capacities, combination of energy efficient inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include group controller also asrequired for controlling ac from a single point and timer option for load sharing of ac units complete all as specified and as directed by engineer - in - charge, of following capacities.note: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. (high side (machines))(outdoor unit) 21 a) 22 tr inverter package ac units 22 b) 16.5 tr inverter package ac unit 23 design, supply, installation, testing and commissioning of normal type floor mounted packaged ac units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like hp/lp cutout, single phase preventor, overload relays, r-410a gas, vibration isolation pads etc. suitable to work till 50 deg ambient, blue fin condensor and corrosion resistant body, wide voltage range 360v - 440v, the quoted rate shall include support works for outdoor units with necessary catwalk for service access complete all as specified and as directed by engineer - in - charge, of following capacitiesnote: design report shall be submitted before execution of work at site by the contractor to ge for his scruitiny/comments and further submitted to ao for his approval.make: blue star/daikin/haeir/godrej/voltas/equivalent. low side (machines))(indoor unit) 24 a) 22 tr inverter package ac units 25 b) 16.5 tr inverter package ac unit 26 supply, installation and testing of refrigerant pipingwith necessary clamping (suction & discharge) hard/soft drawn copper tube of suitable sizes, with copper elbows, tees, tubular nitrile insulations etc as required complete all as specified and as directed by engineer - in - charge. 27 s & f control cabling b/w indoor & outdoor units 28 m & l refrigerant gas - r410a 29 supply, installation and testing of hard pvc drain piping. drain piping with tubular nitrile rubber insulation: complete in all respects, well clamped till drain points complete all as specified and as directed by engineer - in - charge. for all units 30 ductingsupply, fabrication, installation, testing of gi rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per is 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by engineer - in - charge. 31 a) using 0.63 mm (24 gauge) gi sheet 32 b) using 0.80 mm (22 gauge) gi sheet 33 c) using 1.00 mm (20 gauge) gi sheet 34 duct insulation & liningsupply and installation of acoustic insulation of ducts using 9mm open cell nitrile rubber, well adhesived, 150 - 180 kg/cm2 complete all as specified and as directed by engineer - in - charge. 35 supply, installation & testing of thermal insulation of ducts using 9mm closed cell nitrile rubber, well adhesived, 40-60 kg/cm2 complete all as specified and as directed by engineer - in - charge. 36 s & f canvas connection 37 air distribution productssupply and fixing of powder coated aluminium grills/ diffusers (supply/ return) complete all as specified and as directed by engineer - in - charge. 38 s & f collar dampers 39 supply and installation of fire dampers complete all as specified and as directed by engineer - in - charge. 40 supply, installation, testing and commissioning of heater bank plus humidistat arrangement complete all as specified and as directed by engineer - in - charge. 41 supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier hima 7 nhc, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, ac power supply with all connecting accessories complete all as specified and directed. 42 supply and fixrefrigerator, electric driven (single phase), 220 v,50 hz, capacity 195 litres, 3 star rated direct cool inverter, single door all as specified and directed by the engineer-in-charge. 43 supply and install, testing and commissioning of split type air conditioner 1.5 tr capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (cooling appliances- qty 4, air conditioning- qty 10) 44 supply and fix voltage stabilizer 3 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% 45 supply and fix voltage stabilizer 4 kva for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 v to 280 v with output voltage stabilized at 230 v with accuracy of ± 2.5% (cooling appliances-qty4, air conditioning- qty 10) 46 air conditioningsupply and install,testing & commissioning of split type air conditioner 2 tr capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 supply and fix voltage stabilizer 5 kva for automatic operation,single phase naturally air cooled indoor type, wall mounted type & designed for input variation between 170 v to 280 v with output voltage stabilized at230 v with accuracy of ± 2.5% 48 internal electrifications & f led mirror light 1 x 5w lumos ecco 1 feet make: luker or equivalent 49 s & f modular mcb dbox 3 pin socket with mcb sp 20 amp, 240 v including plastic enclosure as per manufacturer instruction fixed on wall surface complete for air conditioner all as specified and as directed. (make:-havells, model-dhdmcsn0251016 or equivalent) 50 supply and fix air circulator of 600 mm sweep ac single phase. 230v, 1440 rpm complete all as specified and as directed. (make: havells model, turbo force wall or equivalent) 51 s & fvertical triple pole & neutral (vtpn), double door, 16-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 52 s & fvertical triple pole & neutral (vtpn), double door, 4-way metallic modular distribution board conforming to iec 61439-3, suitable for flush / surface mounting with provision for fpmccb as incomer and tpn/sp mcbs as outgoing, reversible metal door, 200 a copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having ik 09 & ip 43 protection complete all as specified and directed. 53 m & l for flame proofmcb distribution board spn 12 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb -10 nos as outgoingcomplete all as specified and as directed. 54 m & l for flame proofmcb distribution board spn 8 way, with case iron body, powder painted, with 200 amps rated bus bar etc. including provision of one 32 amps spn mcb as incoming and 6 amps sp mcb- 6 nos as outgoingcomplete all as specified and as directed. 55 supply and fix engage light with green & red led complete all as specified and as directed 56 supply and fix of cs mounted high intensity led search light, long range, manually swivel in all direction, 250 w, minimum range 700 meters, single, led efficiency> 140 lm/w, pf> 0.95, cct 5500k - 6500k, optical grade pmma/pc lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti uv, narrow beam 5 degree, die cast lm6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree c, input volt 100-300 vac, 50 hz, pf >0.95, ip-66, confirming to lm79/ lm80 and type tested as per is: 10322/ is: 13383, bis approved and govt lab tested for lux intensity. the search light is completed with manual revolving cs stand d20cm x h15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. model no. cs-lrfll-25pc25 of kalin make or equivalent 57 supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, enystar emptyenclosures, ip-65, weatherproof, corrosion free, halogen and silicon free, frame retardant with opaque lid size-[276 x 546 x 186]mm and transparent hinged lid, completed all as specified and directed. 58 m & l for tv socket module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 59 m & l for telephone jack with module metal flushed including flushed box cover plate box for 2 way module complete all as specified. 60 supply and lay coaxial cable for tv cabledrawn through conduit 61 s & f flame proof exhaust fan 300 mm sweep, single phase, 1440 rpm complete all as specified and as directed. 62 fire fightingsupply and fix foot valve conforming to is 4038, 100 mmdia. 63 supply and fix foot valve conforming to is 4038, 150 mmdia. 64 supply and fix cast iron air valves with single air outlets, conforming to is 14845 of size 100 mm dia bore and fixing up in cast iron water supply mains of size 100 mm dia. 65 s & f sprinkler flexible drop pipe 1 mtr long. 66 s & f sprinkler rossette 25 mm dia. 67 supply and installation, testing and commissioning of analog addressable type active loop repeater (loop power/external power) fire terminal with inbuit turbo isolator, backlit lcd display 6x40 characters display, having controls for reset, mute, accept, silence alarms and self test, with programmable free keys and duly approved byen54/lpcb/vds/fm make: siemens/notifier/bosch 68 m & l for low smoke zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to bs7629-i, bs6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier type lt53 outer sheath confirming to bs 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 staircase signage down of make bajaj cat part no. 111499 model no. dsdwbb 3w double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 s & f wall mounted led emergency exit signage luminaire lit up using regular mains supply comes with a unique rechargeable ni-cd battery capable of emergency back up upto 05 hours(cat no. 220211 make bajaj or equivalent to cg/havells. 71 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board , made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and comprising of the following:- make of mccb/mcb -mds/legrand/l&t/hegger (main fire fighting panel)incoming(i) mccb 4 pole 160 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release - 01 no.(ii) voltmeter digital type 0-500 volts range flush type with selector switch- 01 no(iii) aluminium bus bar tpn - 200 amps- 1setoutgoing(i) mccb 3 pole 125 amp 50 hz, 415 v with reputing capacity 35 ka with microprocessor based release- 01 no.(iii) mcb tpn 32 amp -02 nos(iv) 80 hp s/d starter- 01 nos(v) dol starter 7.5 hp- 01 nos(vi) motor protection relay32-88 amps- 1 no. (vii) motor protection relay2-5.5 amps- 1 no. (viii) on/off/trip indication lamps, 220 v ac- 6 nos.(ix) start/stop push button, 2 no. (x) phase indicating lamps ryb for incoming and each outgoing connection.(xi) digital type ammeter 0- 150 amps with selector switch and ct coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 m & l for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per is-10221.the coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per is specification 73 supply, installation, test and commissioning cpri approved factoryfabricated, indoor type, lt panel board, made out of 2 mm thick crca sheetsingle door withboth side opening including neoprene rubber gasket, suitable for 440 volt 3 phase 4 wire system, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeddedwith 50x50x6mm mild steel angle iron frame and 750 mm above the normal ground level complete withinternal connection with suitable size of cable, cable lugs and cable glandspcc foundation in cement concrete 1:3:6 (20 mm graded stone aggregate) and testing after installation includingcomplete all as specified and & directedby engr-in-charge comprising of the following :– ( booster terrace pump panel)incoming:-(a) incoming mccb 40 a 25 ka, 4 pole- 01 no.(b) busbar tpn of size 100 apms - 1 setoutgoings:-(a) mcb 3 pole tpn 32 amps,10 ka-2 nos.(b)dol starter for 7.5 hp pump set-1 nos.(c) ammeter class-1, digital panel mounting type 96mmx96mm l & t cat no wds301fca00 including ct 50x5 amps 3 nos & selector switch-4 nos(d) voltmeter class- 1, digital panel mounting type 96mmx96mm l&t cat no.wds301fev00 & selector switch - 1 no.(e) led type indicator lamp 1 set (set of three for r,y,b)(f) mini protecrionrelay 4-11 amp - 1 nos. 74 fire extinguisher mechanical foam type trolly mouted of 9 liters capacity. ceasefire 9 litrs fire extinguisher afff foam type, external cartridge type, pressure guage gross weight 14.6 kg, empty weight5.6 kg, can height 611 mm, diameter 175 mm, discharge time less than 60 secs controllable discharge mechanism, minimum 6 mtrs, applicable on class a, b, can construction deep down & co2 mig welded valve construction: forging & machining, internal coating of can: epoxy powder coating, external coating of can: epoxy poyster powder coating sheet metal thickness 2.0mm,1 year warranty. make cease fire or equivalent. (pol store) 75 supply, installation,testing & commissioning of carbon dioxide (co2) type fire extinguisher of 4.5 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 76 supply, installation,testing & commissioning ofdry chemical powder (abc) stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 77 supply, installation,testing & commissioning of water mist high pressure stored pressure type fire extinguisher of 9 kg confirm to is: 15683, with isi marked/tac approved fitted with required accessories including wall suspension brackets. 78 supply and installation at approved location approved make fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & showel etc, complete. 79 special equipments for storesdesign, manufacture, supply, installation, testing and commissioning of automated storage and retrieval system with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. automated storage and retrieval system shall consist of computer controlled & plc stacker crane driven system for automatically placing & retrieving materials from defined storage locations. the crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 kg (max) complete all as specified and directed by the engineer-in-charge. technical data for design of heavy duty asrs:-(a) dimensions:-height:10 mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)storage capacity:-pallet size: 1300 (w) x 1200(d) x 1250 (h) in mmpallet nos.: 480pallet load capacity: 1125 kgtotal capacity: 540 tons(c) stacker crane: single mast automated stacker crane for handling pallet, size 1300mm(w) x 1200mm (d) x 1250mm (h) and pay load (including pallet self weight) of 1125 kg max. the stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. stacker crane will be mounted on single rail at the bottom to traverse the length of the storage system. a single top rail mounted on the racking system shall also support it.general technical parameters of stacker crane:technical parameters/type- single mast(i) operation mode (networking)- on-line automatic / single automatic (ground/boarding) /manual operation (boarding) / maintenance (ii) communication means- wireless 80 (iii) power supply mode- 380 to 415 v, 50 hz, three phase five wire (iv) addressing mode- horizontal and verticle operation: photo electrical sensor + bar code scanners(v) positioning / reduction accuracy (mm) level- lifting ± 3 - 5, fork : ± 3(vi) fork unit- 1 double deep fork(vii) load unit- ms pallet (viii) total height- 10 mtr(ix) the normal lifting speed (m/min) - 10 mpm(x) the normal running speed (m/min) - 65 mpm(xi) rated load- 1125 kg(xii) receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- conveyor(d) pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 kg at height up to the last loading level in the racking system. it should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.pallet details:-(i) dimensions - 1300mm(w) x 1200mm(d)(ii) pallet height- 1250 mm(e) racking system :- two aisle having two row racking system each with 05 verticle levels for storage of material. racking for double deep type storage of 480 pallet of size 1300mm(w) x 1200mm (d) x 1250mm (h). loaded pallet weight: pay load with pallet 1125 kg max. system details:-working aisle -01 nos. (double deep)store rack -24 nos./rowtotal rack in 1 aisle-24 (left) + 24 (right)= 48 nos.no. of level- 5 nos/racktotal pallet-48 x 5 x 2 = 480 nos.load capacity- 1125 kg/levelsingle mast stacker crane-01 no. 81 (f)aisle equipment:-this will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. the mechanical aisle equipment of bottom rail shall consist of i beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. top rail shall be mounted on the racking. the electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) details of rack members:-the racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) loading- unloading station/ conveyor(i) pallet load 1125 kg max.(ii) bearing- skf equivalent make(iii) motor- seimens/sew euro drive/nord sew/ bonfiglioli or equivalent(iv) gear box- bonfiglioli make or equivalent(v) v.f.d.- yashkawa make or equivalent(j) all steel surface shall be powder coated finish with 8 tank treatment process.(k) maintenence: the annual maintenence of complete asrs system duyring the defect liability period of two years shall be included in the rate quoted for the system and the amc contract duly signed with the manufacturer of the asrs system shall be submitted at the time of handling over the system. the amc shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountnote- 1mechanical safety provision (i) end of aisle shock absorbers / bumpers for stacker crane.(ii) end of travel buffer for the lifting crane.(iii) safety catches on lifting carriage.(iv) anti-tilt mechanism for the stacker crane.(v) continuous rail cleaning brush for floor rail.(vi) adjustable rail clamp to ensure alignment. 82 (vii) resilient rubber pads on adjustable clamps for vibration dampening.(viii) profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. note - 2 electrical safety provision (i) there shall be emergency stop push button at all panels and stations.(ii) optical light beam amd mechanical safety sensor to stop the operation in case of improper storage or obstruction in the operator window either internal or external reasons like operator hand or material placed at edge of the tray.(iii) back up circuitry for proper system operation.(iv) an electromagnetic brake shall be used to avoid the slippage of the hoist.(v) stopper shall be provided for the maintenance door.(vi) load cells shall be provided for the over weight of tray.(vii) automatic door shall be provided for operator safety while machine in operating condition.note - 3 physical safety provision (i) the asrs system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. height of the fencing should be minimum 2.0 meter.(ii) one no. of electromagnetic aisle access door shall be provided. it should cover the complete length of the system on one side.(iii) a manual locking system to restrict the movement of unauthorised personnel shall be provided.note: design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. item no. 13.070 below shall be compatible with this item/ system and both should be integratedmake of asr system:armstrong ltd/ godrej koerber/ kardex india storage solutions pvt ltd/ daifuku india pvt ltd/ addverb technologies ltd/ craftsman automation ltd/ tech-mark 83 supply, installation, testing and commissioning of advance inventory management system with computer hardware with compatible inventory software complete all as specified and directed by the engineer-in-charge. technical specification of the system(i) system height : 6400 (±100) mm(ii) system width : 3150 (±100) mm(iii) system depth : 2300 (±100) mm(iv) system base : 7.24 sq.mtr(v) tray int. size: 300 (h) x 2450(w) x 500 (d) in mm(vi) tray dead weight - 57 kg (approx.)(vii) per tray weight capacity - 300 kgtechnical specification of the system:-(viii) tray quantity : 32 nos.(ix) usable net load - 9.6 ton(x) storage surface area per system - 39.2 sq mtr(xi) door - automatic(xii) power consumption - 3.7 kw(xiii) power supply - 440v, 50/60 hz, 3 phase(xiv) motor 3 phase 1440 rpm - seimens make or equivalent(xv) chain - diamond makeor equivalent(xvi) bearing - skf/ntn make or equivalent(xvii) external cladding - epoxy powder coatedsafety features:1. photo curtain at access port, 2. motor protection relays, 3. limit switch at door, 4. single phase preventer,5. switch mode power supply, 6. 15 min battery backup for plc, 7. noise less than 60db, 8. emergency stop various safety alertsnote: the system and software provided under this item shall be of same make as for item 13.069 or a compatible system and software as recommended by the chosen manufacturer of asr system. this system shall be integrated with asr system. 84 supply, installation and testing of car traffic boom barrier 6 mtr suitable to working on power supply 230 volt, 50 hz, 24v dc electric motor, adjustable with cams, operating ambient temperature from -20 to +55 degree celsius, uses cycle 2000/day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 nm open/close time 2 to 4 sec complete all as specified and as directed by engineer-in- charge.make: faac/parkilo/skidata/bft 85 external water supplysupply and fix foot valve conforming to is,100 mm dia complete all as specified and directed. 86 supply and fix cast iron air release valve with 100 mm bore and two outlets as per is:14845 complete all as specified and directed. 87 supply, installing, testing and commissioning of electrically driven horizontal centrifugal pump set 9.0 lps at 50 meter head as per specification, motor tefc type, 2880 rpm, 415 v, 50 hz, 3 phase, class f insulation, ip 55 protection, starting on suitable star delta starter. the pump shall be horizontal, end suction, top discharge. the pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on rcc (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 lpm at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, pvc insulated copper cable connection from starter to the motor terminals all as specified and directed by the engineer-in-charge.(01 no. working + 01 no stand by)make:- kirloskar brothers/crompton or equivalent. 88 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.0 mm thick crca sheet, cpri approved having, ip 43, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply, bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2.0 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: lt panel for pump house. the lt panel comprising of the following:- 89 incoming:-mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, breaking capacity 36 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 01 sets(b) digital multi function meter - 01 no.(c) cts - 100/5a, cl-1, 15 va - 01 set(d) horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 350 amps for phase and 350 amp for the neutral baroutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 16 ka- 02 no. ics =100% icu -2 nos.(b) mcb, tpn 40 amp, 415 volt, c curve - 02 nos.(c) star delta starter 12.5 hp, 3 phase, 415 volt- 02 nos.(d ) digital ammeter - 2nos.(e) single phase preventer - 2 nos. 90 m & l valve chamber of internal size 0.90m x 0.90m x 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick pcc in 1:4:8 type d2 foundation, brick work in cm 1:6, 15 mm thick rendering in cm 1:4 to internal surfaces and external surfaces upto 150mm depth below gl, pcc 1:3:6 type c1 as in coping, cover with two nos. of hinges and one no. handle made out of ms round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. note:- the quoted rate shall include all earthwork and connected items. 91 m & l earthing complete with galvanized steel earth plate electrode of size 600mmx600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal gl and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in electrical plate no. 3 connecting to earthing test point, including necessary earth work in any type of soil, pcc earth chamber made in pcc 1:3:6 type c1 (using 20mm graded aggregate), common salt, charcoal, ci funnel, earth pit cover in rcc 1:2:4 type b1 (using 20mm graded aggregates), with 8mm ctd bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 external electrificationm & l for ht/lt ms cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm ms strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of pcc 1:4:8 type d-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.note: ht route indicator shall be painted as under:-(i) for ht 11 kv cables - “brown”(ii) for lt cables - “blue” 93 supply and fix compact air insulated bus bar trunking system with copper busbar 1600 amps, 50 ka breaking capacity, ip54 protection, bus duct 1600 a, 415 volt, capacity sandwich type, set rybn complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to lt panel board complete all as specified and directed. 94 supply, install, testing and commissioning of distribution transformer step-down level 2 (previously ee level 3 before amendment no 4 to is 1180), 11kv0.433kv, three phase complying withis: 1180/iec-76(part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 hz system of capacity 800 kva, oil immersed naturally cooled delta connected on ht side and star connected on lt side, vector group dyn11, provided with off load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & half load (50 %) shall not be exceeded 5838 watts & 2147 wattsrespectively as per grlha rating, percentage impedance: 4.5%. losses and impedance are subjected to tolerance as specified in is 1180. the transformers should be supplied with first filling of oil confirming to is 335. the transformer should have both side cable end box with neutral brought out complete all as directed by engineer - in -charge, and installation of transformer shall be carried out as per is-10028and comprising with the following standard fittings/technical specifications:-(a) lifting lug for transformer and tank.(b) earthing terminal rating and diagram plate.(c) air release device.(d) oil filling inlet pipe with plug.(e) drain outlet pipe with brass gate valve.(f) conservator tank with oil level indicator(g) silica jel breather(j) first fill of oil upto level including conservator tank with fresh new oil conforming to is335.(k) type of connection delta/star(l) type of cooling: oil and natural air.(m) vector group: dyn 11.(n) temperature rise over an ambient of 50 °c maximum.(o) cable end box on both side for ht/lt cables of suitable size.(p) provision of thermometer with pocket.(q) provision of oil and winding temperature gauge. 95 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. andcomprising as under: the lt panel comprising of the following:- main lt panelhorizontal copper busbar for 3 phase, 440 volts, 50 hz, 4 wire system of rating 1600 amps for phases and 1600 amps for neutral. 96 incoming:-incomer:-acb 4 pole, 415 v, 50 ka with thermal magnetic release (manual draw out type) of capacity 1250 ampmetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 1600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, ics =100% icu, breaking capacity 35 ka, ics =100% icu- 02 no. (for dg amf panel & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for apfc panel & fpb 2 near bulk store) (c) mccb, thermal magnetic release, 4 pole, 415 volts, 320/315 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for fpb 1 near adm block) (d) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 01 no. (for existing load)(e) mccb, thermal magnetic release, 4 pole, 415 volts,125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for fpb 3 near auction disposal store)(f) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for mt complex, watch tower no 2, guard room)(g) digital ammeter with suitable ct for each outgoing 97 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, ms angle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables. providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (near admn bldg) 98 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral.incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for 2nd floor & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for 1st floor)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for g floor)( d) digital ammeter with suitable ct for each outgoing 99 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.2 (near bulk store) horizontal aluminium busbar for 3 phase,440 volts, 50hz, 4 wire system of rating 600 amps for phases and 600 amps for neutral. 100 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type)- 1 sets(b) digital multi function meter - 01 no.(c) cts - 600/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for equipment load & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for bulk store)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for watch tower no. 1)( d) digital ammeter with suitable ct for each outgoing 101 supply, install, test and commissioning of lt panel, outdoor type, powder coated, 3.00 mm thick crca sheet, cpri approved having, ip 54, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 2 mm thick crca sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, crack resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.3 (near auction disposal store) 102 horizontal aluminium busbar for 3 phase, 440 volts, 50hz, 4 wire system of rating 200 amps for phases and 200 amps for neutral.incoming:-(b) mccb, thermal magnetic release, 4 pole, 415 volts, 125 amps, breaking capacity 25 ka- 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 200/5a, cl-1,15 va - 01 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 100 amps, ics =100% icu breaking capacity 25 ka- 02 no. (for store dispatch complex & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 03 no. (for pol store, auction disposal store, covered hard standing)(c) digital ammeter with suitable ct for each outgoing 103 supply and fixing poly carbonate street light junction boxes ip 66/67 weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitablecable connecting terminals, cable lugs, including provn of one no. mcb sp 6 amps for operating the street light fittings, suitable cable glands as per site requirement, all as directed by the engineer-in-charge. 104 s & f street light bracket made out of gi tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary ms clamp-02 nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core frlsinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.note: phase should be red/yellow/blue, neutral should be black and earthing wire should be green in colour. two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 supply and fixing of led ?ood light, 200w, watt 230 v, ac outdoor type with thermal management in multiple optics and equipped with ip66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power leds and secondary lenses with ip protection incl system efficiency >110/120lpw 10kv spd included energy saving, environmental friendly and general purpose lighting complete all as specified and directed engineer-in-charge. make : make : crompton/philips/wipro 106 supply and fix high mast panel outdoor type, suitable to take load up to 6 kw, conforms to is/iec 60947-4-1, provided with protection degree ip 54, extended wide band (150 vac - 300 vac) coil, frls (fire retardant low smoke) internal wiring, in-built short-circuit protection, class h insulation, 3 phase 415 volts ac with the following accessories:phase : 3 phase, 415 voltsmax load capacity : 6 kwtimer type: astronomicalcontactor rating : 32 a tpmcb rating : 63 a tpnmake : crompton/ philips/wipro 107 supply and laying dwc (double wall corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming is 16205 (part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm st light cable & 16 sqmm cable) 108 aviation obstruction lightsupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one no.10 a, mcb, spn 230 v with fixed enclosure complete all as specified and directed by engineer-in-charge.make:- bajaj cat no bgav 302 led or equivalent in philips/crompton/surya 109 incineratorsupply, fixing and testing of solid waste electric incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°c, stainless steel stack for longevity, fitted with a velocity cowl as standard, chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree celsius mounted on foundation as recommended by oem including electrical control panel with suitable size mccb, relays & contactor recommended by oem complete all as complete all as specified and directed.note:(a) the electrical works including electrical lt panel, internal wiring of the lt panel, suitable size copper wires from panel to solid waste electric incinerator as recommended by oem to operate the solid waste electric incinerator of capacity 100 kg/hr to make solid waste electric incinerator operational is deemed to be included in the rate quoted. (b) all electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed there under and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solid waste electric incinerator of capacity 100 kg/hr all as mentioned above and which is not mentioned or included in this schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) foundation/plinth/base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the solid waste electric incinerator and height of plinth shall not be less than 0.5 m 110 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 200 amps, breaking capacity 36 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 electric sirensupply and fixing sirens electronic type horizontal double mounting three phase 400/440v, 2800 rpm 50 c/s flame proof, audible range 3.5 km, 2 hp, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 supply and fix advance sirens controller electronic type suitable to operate on 3 phase, 415 volt ac 50 hzcomplete all as specified and directed. 113 supply & fixing mccb, thermal magnetic release, 4 pole, 415 volts, 63 amps, breaking capacity 25 ka- 01 no.ics =100% icu with sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 solar power plantdesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (on-grid) on roof top of existing bldg of capacity 150 kwp, power evacuation at 415 volt 3 phase system all as per guidelines/norms issued by mnre & indian metrological deptt approved solar radiation data viz direct normal irradiance, global horizontal radiance etc complete comprising with the following solar photo voltaic plant.(a) design, supply, installation, testing and commissioning of solar pv modules capable of generating 150 kwp (ac) electricity at 415 volt 3 phase system. these solar pv modules of 540 watt perc with a modular efficiency of 17-19.84% as per iec and mnre standard or as per approved design parameters with poly/multi crystalline silicon solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to iec 61215, iec 61730, iec 61701. solar pv module should be of approved indian brand only and qualify under the domestic content requirement (dcr) norms of nvvn/seci and testing requirement fixed by mnre. the pv modules shall be warranted for a period of minimum 25 years, solar pv modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of ten years and 80% at the end of twenty five years. each solar pv module must use rf identification tag. the following information must be mentioned in the rfid used in each module:name of manufacture of pv module, name of manufacturer of solar cell, month & year of manufacturer (for solar cell and module), country of origin (lt is mandatory to use cells and modules manufactured in india). i-v curve of the module, wattage, lm, v-m, & ff for the module, unique serial no & model no of the module, date & year of iec pv qualification certificate, name of the test lab issued iec certificate. the pv modules used in the solar power projects must qualify to the latest edition of the following international electro technical commission (iec) p module qualification test or equivalent bis standards. the pv module must be tested and approved by one of the iec authorized test centres. 115 (b) material and labour for module mounting structure (mms) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 kmph wind speed all as per approved design parameters as per mnre standards and to match with the existing site conditions. necessary roof treatment to avoid any seepage in future shall be done by the contractor and the amount included in the rate quoted. the roof tiles shall be dismantled and refixed back in original position. structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) supply, laying & testing of dc cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant is, weather proof uv resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of spv modules to array junction box including suitable size of cable lugs, male & female mc4 connectors & joints etc.(d) supply, installation test and commissioning of protection devices mccb 400 a, isolator and three phase 4 wire lt energy meter, array junction boxes having rating 150 kwp with over voltage protection and surge protection.(e) supply, installation, test and commissioning of grid tie solar power conditioning unit / inverter of minimum capacity 150 kwp(dc to ac 415 v in three phase system) all as per approved design parameters & capable of generating output voltage 415 v ac at rated load condition with efficiency not less than 98 %, conforming to iec 600682-2 nde standards with power reduction, lvrt with protections for anti-islanding, ground fault monitoring, grid monitoring, ac & dc over voltage and under voltage protection, ac & dc short circuit lover current protection and dc reverse polarity protection, graphic display etc. all as specified and as directed.(f) material and labour for earthing for lightning protection for spv modules etc as per ie rule, mnre guide line & bis all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including gl strip 32x6mm size protected with gl medium grade pipe 40mm dia for earth electrode up to test point by means of gi nuts, bolts, check nuts and washers including earth work excavation, pcc (1:3:6) type cl pit and rcc cover ( 1:2:4) type bl and funnel, with necessary charcoal, salt etc complete. 116 (g) supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for spv modules lightning protection upto interconnection between roof top la to ground earthing system. (h) ac cable: supply and laying of 150 sqmm lt xlpe insulated, screened pvc bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to is 150 sqmm x 3.5core as per site requirement.note (i) :-(a) before quoting the bid, contractor or his authorised engineer/consultant must visit the proposed site to study the site condition.(b) before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to accepting officer for approval.note(ii):-(a) the mechanical structures, electrical works and overall workmanship of the grid solar power plant must be warrented for a minimum of 5 years.(b) all mechanical, electrical works shall be carried out as per relevant bis/ls equivalent standard norms only and also in accordance with the latest edition of the indian electricity act / rules formed thereunder and as amended from time to time.(c) any other works (mechanical, electrical & civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 kwp (ac) all as mentioned above and which is not mentioned or included in this schedule a but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) contractor shall provide adequate spares/items required for minimum period of 1 year maintenance including dc & ac items under scope of work.note (iii) : design report shall be submitted before execution of work at site by the contractor toge for his scrutiny / comments and futher submitted to ao for obtaining approval. 117 dg setsupplying, installing, testing and commissioning, factory assembled silentdiesel engine driven generator set, fully wired alternator ac to give an out put of 400 kva continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 hzsupply, 1500 rpm, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, pcc foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a)diesel engine: liquid cooled turbo charged with after cooler to deliver suitable bhp at 1500 rpm under ntp conditions of bs 5514 and conforming to is 10001/ 10002, din 6271 & iso 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class a1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) radiator with blower fan or heat exchanger with guard.(b) pipe coupling for engine cooling system piping.(c ) corrosion inhibitor coolant(d) paper element filters(i) fuel filter(ii) lube oil filter(iii) by pass(e) fly wheel housing and fly wheel to suit alternator.(f) engine bearing mechanism in fly wheel housing.(g) shut off coil with safeties for llop/hwt/over speed.(h) dry type air cleaners and vacuum indicators.(j) residential silencers.(k) stainless steel exhaust flexible bellows. 118 (l) motor driven priming pump.(m) battery charging alternator.(n) exhaust piping made out of stic c class, ms pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(o) mineral wool insulation 2 inch thick suitable for 400 degree celsius temperature cladded with aluminium sheet o30 gauge for the entire length of exhaust pipe.(p) first fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) interconnecting copper cabling of adequate capacity batteries control.(r ) fuel pipe class stic 1 /1.5 /2 dia - 01 lot(s) self starter 12 volts dc.(t) electric operated electronic governor.(u) fuel injection pump.(v) no of cylinders - 12 no vee(w) electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24v battery. (ii) water temperature.(iii) lubricating oil pressure.(iv) engine speed -1500rpm(v) engine hours(vi) frequency.(vii) voltage.(w) safety control (trip and indication).(i) high water temperature(ii) low lube oil temperature(iii) overspeed stop 119 (x) base frame: sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith avm pads.(y) battery:-24 volts(2x12v battery) dc, 180ah, maintenance free battery conforming to is:14257 with leads & terminals (make- excide/amron).(z) fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick hr/ms sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) isolator panel with 250 amp mccb(ab) auto logic panel for automatic stat(b) alternator: alternator suitable rated for 400 kva, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 hz at 1500 rpm, self excited and self regulated with avr brushless, screen protected, drip proof , insulation class-h, ip -23, voltage regulationgrade - vg 3 self ventilated and conforming to bs: 5000 / is: 4722 suitable for engine as mentioned here-in before, conformig to is: 13364(part-1)make: koel green / stampford/crompten/kirloskar/greaves(c) acoustic enclosure:- m & l for acoustic enclosure for the above 400 kva dg set to reduce noise level to 75 db measured at 1.0 meter distance for audible frequencies as per guide of central pollution control board andmanufacturers specification and comprising of following from authorised goems of gen set manufacturers specified :-(i) sound insulation : 100mm thick rock wool (density 64 kg/cum).(ii) outer body : 1.6mm thick crca(iii) door : 1.6mm thick crca(iv) base frame : ismc 300(v) inside illumination : 1 no.- 1 x 18 watt led fitting of make phillips/ bajaj/ crompton.(d) amf control panel:- factory fabricated cubicle type, free standing, floor mounted, indoor type, ip-43, amf control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick crca sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (e) amf control circuit with 4 pole mccb 630 amps - 2 nos, with ultimate breaking capacity icu-50 ka at 415 volts and microprocessor release conforming to iec 60947 part-i with breaking capacity ics=icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 nos. for main supply & dg set supply with hrc back up fuse complete with all dc control relays/ line voltage monitor (lvm) as per oem specifications incorporating motorised stored energy operating engine start, stop, three attempt starting facility and failure to start etc.(f) digital load manager : three phase 4 wire indicating v,i,pf, kva, kw, f of enercon make with serial communication port model no.em6400 with class 1.0 accuracy meter or equivalent make suitable rating of ct per phase- one no.(iii) indication lamp r, y, b with 3 nos. of 2a hrc fuses-10 sets.(iv) bottom gland plate for incoming and outgoing cables.(v) circuit diagram plate.note :- dg set should be as per cpcb -4 latest norm wef 01 july 2023 of national clean air programme (nacp) act 1981. 121 supply, install, test and commissioning of lt panel, indoor type, powder coated, 2.00 mm thick crca sheet, cpri approved having, ip 43, msangle iron section of 50x50x6 mm frame, suitable for 3 phase 415 volts 50 hz, ac supply,bus bar chamber with horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air.the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. the inner shell be made out of 1.6 mm thick crca sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing mccbs/mcbs and metering devices and suitable busbar chamber for passing and connecting ug cables.providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size f class insulators made on non hygroscopic, non combustile, track resistant, high strength frp/smc/dmc material at an interval of not more than 300 mm through out the length of the tpn bus bar all as specified and directed by the engr-in-charge. feeder panel no.1 (dg panel ) 122 incoming:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 630 amps, breaking capacity 36 ka - 01 no. ics =100% icumetering unit:- (a) r y b indications (led type) - 1 sets(b) digital multi function meter - 01 no.(c) cts - 800/5a, cl-1,15 va - 1 setoutgoing:-(a) mccb, thermal magnetic release, 4 pole, 415 volts, 400 amps, ics =100% icu breaking capacity 36 ka- 02 no. (for package ac bulk store & spare)(b) mccb, thermal magnetic release, 4 pole, 415 volts, 160 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for pump house & fire pump)(c) mccb, thermal magnetic release, 4 pole, 415 volts, 80 amps, ics =100% icu breaking capacity 25 ka- 01 no. (for incianator)(d) mccb, thermal magnetic release, 4 pole, 415 volts, 32 amps, ics =100% icu breaking capacity 25 ka- 07 no. (for terrace pump 1, terrace pump 2, power house, high mast 1, high mast 2, street light)(e) digital ammeter with suitable ct for each outgoing(f) astro time switch for 3 phase 20a- 1 no(g) 3 phase power contactor 20 amps, with 230 coil 123 sewage disposalm & l for laying of dwcpe sewage pipes line 200 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 m & l for laying of dwcpe sewage pipes line 150 mmdia borepipe sftiffnessclass sn 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 compound walls & f concertina coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm gi wire for securing, coil with fish hook bars, incl necessary welding to ms sections etc all as specified and directed. 126 green building norms(griha concept)supply and install organic waste converter fully automatic having capacity 50kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-type of machine: fulley automatic in-vessel compostercomposting method: 24 hrs. micro-organisms-based compostingmachine type of microganism used: heat resistant thermophilic bacteria final output: dry organic soil conditioner/soil supplementscycle time: 24hrs volume reduction in 24hrs: 80-85% internal tank: stainless steel type main agitator shaft: stainless steel type input voltage: 415vspecial features: vfd as standard across all models, touchscreen standards daily waste processing: 150kgs rated capacity: 7kwpower consumption (kwh par cycle): 13-15length: 1650, width: 850,height: 1455 127 supply, installation, testing and commissioning three phase energy meter with the following specifications: microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (nb-iot) communication that allows it to interact with the head end system (hes) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 volts, 50 hz of range 10-100 amps, complying to is16444:2015 (reaffrimed 2020) and conforming to is 3779 with led display and parameters like voltage, current, frequency, power, power factor, kwh/kva, default in built dual source, inbuilt long range (lorawan) communication suitable for outdoor lora data accumulator and also compatible for prepaid and postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to erp complete with 5 years warranty.note:(a) the contractor would be responsible for removing the existing meter, noting down the reading and depositing it with the mes age e/m store complete all as specified & directed.(b) the energy meter to be capable of running in both prepaid and postpaid mode.(c) the meters to carry 5 year warranty. (for entire system) 128 supplying, fixing, commissioning and testing of configuration of cloud hosted multi user web based software with following modules:(i) head end system (hes): to acquire meter data automatically from dcu sand monitor parameters acquired from meters.(ii) meter data management modulethe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. the system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters cumulative energy. cumulative apparent energy (as applicable), power, current, voltage, power factor and frequency(b) monthly billing survey data for cumulative energy and max demand(iii) billing module: the billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. the billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. it would allow postpaid and prepaid functionality as required.(iv) occupation and vacation module: the system would support occupation/vacation based on the unit catagories. the system would support automatic data capture on occupation and vacation events.(v) website: there would be a dedicated website forage/ge and bso team to view all the data and information alongwith customer portal for use of customer. the designated users in mes would have the admin access to the application. the mes staff would also have the access to the key information on mobile app (androiandios based) for admin use complete all as specified and directed.(vi) customer module: the system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. there shall be consumer app (android and ios based) also to log in and view their own energy/billing data and recharge facility.(vii) communication module :the system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) meter master data: the system would support meter data repository. the system would support meter replacement process.(ix) excel export: the system would support export of metering and billing data in excel and pdf format.(x) energy accounting module: the system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) prepayment/recharging facility:the system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. the system should allow online/digital recharging through consumer app (androidand iosbased) and web portal. the configuration and necessary arrangement for payment gateway and e-mro facility shall be deemed to be included in the quoted rate. the system should sendconnect/disconnect command on the basis of available credit.low credit alarm: the system will give an alarm over the consumer app and sms to the registered mobile number in case the credit in the meter goes down be low apredefined limit.emergency credit: the meter will work even when the credit falls down to zero to prevent disconnection. this limit shall be configurable. the system should support happy hours inorder to prevent disconnection in non working hours and on holidays. the happy hours should be configurable complete all as specified and directed. 130 supply, installation, testing and commissioning of dcus/gateways and the arrangement of sim cards or internet to enable reliable medium for two-way communication between smart meter & hes. the data acquisition (push/pull) frequency shall be, configurable. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. it shall have provision for the cellular, wifi and ethernet communication for the backhaul to hes. it shall be capable to handle data of minimum 1000 nos. of any type of smart meter (1ph/3ph).it shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. communication of the nearest meters with other meters shall be established through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. the equipment shall be weather proof and dust proof (minimum rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 hosting gprs (4g) charges for gateway for five years from the date of completion f including 2 years waranty and 2 years maintinance after warranty) make:-airtel/jio/vodafone 132 supply and installation of digital water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 supply and installation of digital water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 arboriculturem & l for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 all as per item no 13.121 above but pit size 60cm x 60cm x 60cm 136 supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 supplying and planting flower plants(champa/ hybrid hibiscus/ hybrid west indian jasmine/ hybrid plumeria white plant/ panama yellow plant/ oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 supplying and planting song of india flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 supply and planting mexican grass including providing manure as directed. 144 pile foundationboring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.note:- the quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. nothing extra shall be paid on this account. 145 boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using dmc method (direct mud circulation)and getting out & disposal of spoil to any distance outside of md land , complete all as specified and as directedby the engineerin charge 146 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in cast in situ dmc bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 m & l reinforced cement concrete of grade m-35 design mix (rmc) as per is-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 149 providing tmt bars (crs/hcrm/crm) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia ms wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (fe-500d). 150 all as per item no 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 m & l for providing pcc (1:4:8) type d-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 m & l for carrying out non destructive integrity test all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 m & l for carrying out initial load test (vertical load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 155 m & l for carrying out initial (lateral load test) cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 156 m & l for carrying out initial load test ( pull outtest) of cast in situ piles of 600 mm dia as per is 2911 (part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(note :- providing and installing test piles shall measured and paid separately) 157 m & l for carrying out routine load test (vertical load)all as per is 2911 (part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 158 testing of piles (initial load test) for 450mm dia cast in situ bored piles all as per is including removing the testing equipments from the site after testing is completed all asspecified and as directed
  • View Tender
  • Document
  • Bid Support
3 Construction
image image
State Government
TRN :49065891 |  14 May, 2025
Tender Value : 7.52 Lacs
 Solapur - Maharashtra
Tender for a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshiras supplying, instarting testing and commissioning of 1 hp capoty ac/dc solar 104076.00 j water pump (bpv pumps, comprising of men. 1 kwp capacity muls crystalline spv modules mounted on gi /ms seucture with necessary hardware with controler, soltable size hdpe delivery water pipe tine up to 60mer length inside or above water tank/boreweit with necessary control valves and necessary power supply cable of appropriate size complete with 5 years on site performance wamanty as per specification no. esd-swps , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras , a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshirasproviding & fixing of special water chamber for dual pump , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras , a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshirasproviding & fixing garware wire rope 10 mm (market plate) (market rate) , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras , a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshirasexcavation for foundation/pipe trenches in hard murum including removing the excavated material upto a distance of 50 m and lifts as below, stacking and spreading as directed by engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras , a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshiras refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras , a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshiras providing and laying in situ cement concrete m-15 of trap/ granite/quartzite/gneiss metal for foundation and bedding including balling out water, form work, compaction, cuning, etc, complete (cement 5.90 bags/cum) , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras , a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshiras ball cock for 25mm dia , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras , a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshiras providing and fuxing on walls/ceiling/floor 25 mm dia, upvc pipe with necessary fittings, remaking good the demolished portion etc. complete. including removing existing pipe line if necessary and conveying and stacking the same in pwd chowky or as directed etc. complete , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras , a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshiras supplying and erecting high density polythene pipe isi mark 32 mm dia, suitable for pressure of 6 kg/cm2 connected to jet/submersible pump with required material complete , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras , a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshiras providing structural steel work in brusses, other similar trussed purlins and members with all bracing gusset plates, etc as per detailed design and drawing or as directed by engineer-in-charge including cuting, fabricating hoisting, erecting and fixing in position, making riveted bolted/welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc complete , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras , a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshiras providing and fixing h.d.p.e. container syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras , a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshiras for outlet of tank: providing and fixing on walls/ceiling/floor 50 mm dia. upvc pipe with necessary fittings, remaking good the demolished portion etc. complete. , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras providing & constructing two taps stand post as per type design with excavation 15 cm thick pcc 1:3:6 bedding 20mm thick pcc 1:4 concrete for platform of 1.75 m.dia with side curb and bucket rest, 80 mm dia, hevay duty gl pipe central post duly folled therein with cc 1:2:4, 5m. long 20mm dia. medium gl pipe from point of tapping to standpost, additional 20 mm dia gl pipe fixed vertically upto 15mm dia. self closing water taps, one brass, ferrule, etc.complete together with all labour and material charges as per drawing and as directed by engineer-in-charge when good foundation is available. rate excluding draining arrangement by excavating open gutters. , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras for outlet of tank: providing and fixing on walls/ceiling/floor 50 mm dia. upvc pipe with necessary fittings, remaking good the demolished portion etc. complete. , a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshiras for outlet of tank supplying and erecting isi mark g.l.pipe 50 mm dia.bclass at position with accessories. as per specification no.cw-plb/gp , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras , a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshiras ball valves for 50mm dia. (brass/gun metal) , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras , a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshiras supplying & erecting water lavel controller 230/415v ac., four way for under ground & over head tank operation , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras , a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshiras supplying, erecting, testing and commissioning of flat flexible 3 core 4 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras , a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshiras information board of scheme providing structural steel work in trusses other similar trussed purlins and members with bracing gusset plates etc. as per detailed design and drawing or as directed by engineer in charge including cutting fabricating hoisting erecting and fixing in position making riveted bolted welded connections and one coat of anti corrosive paint and over it two coats of oil painting etc. complete , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras , a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshiras material & labour for vinyl painting of matter given by dept. in diff. colour as per r.c , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras , a) implementation of solar energy based dual pump mini water supply scheme z p school surwasewasti at falwani tal malshiras add gst 18% , b) implementation of solar energy based dual pump set and other allied work z p school surwasewasti at falwani tal malshiras , c)supplying, installing, testing and commissioning of 1 kwp on-grid solar pv system/plantz.p.school, aasabe wasti, at falwani, taluka: malshiras.on grid solar pv system supplying installing, testing and commissioning of 1kwp on grid solar pv system/plant consisting solar pv poly crystalline panel (335 wp x 00 nos) and solar on-grid inverter of similar capacity (thd-31%) with interconnecting wires/cables up to solar on grid inverter, proper base plate, canopy box to house livener and necessary accessories l. acdb/dcdb, mcb ets wiring up to solar inverter in casing and capping display board, sign board, two distinct sathing, lightning armester, liaisoning charges, remote monitoring system with maintaining card/chip for 5 years including net charges for rms rystem, complete up to net meter installation and export to the grid with 5 year on-site warranty and fully comprehensive maintenance contract as per specification no. esd-rt-ong , supplying and erecting single phase 10 to 60 a net meter of accuracy class 1.0,240v, 50 hz, with backlit lcd display, optical port (measures import kwh export wh, net kw, v, 1 kw, 12 months history of energy) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. , supplying and erecting static energy meter with 240v 50 hz. ac supply 10 to 60 a, isi mark, accuracy class 1.0 with backlit lcd display, (measuring and display kwh, kvah, v,lpf, frequency, kw, kva, six months history of energy & md in kw & kva) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weat proof pvc wires duly tested by electric supply company. , supplying and erecting pvc insulated pvc round sheathed 4 sq mm (56 no.x0.30 mm dia 13 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv , providing and laying in situ cement concrete m-15 of trap/ granite/quartzite/greiss metal for foundation and bedding including balling out water, form work, compaction, curing, etc. complete (cement 5.90 bags/cum) b) in pcc m-150 , providing structural steel work in trusses, other similar trussed purlins and members with all tracing gusset plates, etc. as per detailed design and drawing or as directed by engineer-in-charge including cutting, fabricating, hoisting, erecting and fixing in position, making riveted bolted/welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc complete , supplying, installing, testing and commissioning solar street light pole comprising of 12w led luminaire, 12.8v-30ah li battery, with 75wp solar panel, ms powder coated battery box weatherproof, mounted on 75/80 mm dia bgrade gi pole of mir. height (5m above ground & im below ground), 12w led chip of luminaire should be in compliance to ies: lm-80 & performance parameters of luminaire shall be as per ies lm-79.2008 or 15 16106: 2012), along with brackets, foundation, earthing and necessary accessories complete. , information board of scheme material and labour for painting of matter given by dept , add gst 18% , d)installing ele. pump and distribution pipe line etc.mane wasti anganwadi at falwani tal malshiras supplying, erecting, testing and commissioning of minimum three & above star rated submersible pumpset of 1.125 kw1.5 hp with 230 v, single phase, 50 hz, a.c. supply suitable for 100 mm dia, borewell with 10 to 100 ipm discharge at 137 to 40 m head & discharge & delivery pipe of size-32 mm dia, with a necessary h type clamps as per specification no. wp-smp. , supplying, erecting, testing and commissioning of d.o.l starter suitable for 250 v, single phase 50 hz with overload element with necessary materials and connected to supply upto 3 hp. , providing & fixing garware wire rope 12 mm (market rate) , ball cock for 25mm dia , providing and fixing on walls/celling/floor 25 mm dia upvc pipe with necessary fittings, remaking good the demolished portion etc. complete. including removing existing pipe line if necessary and conveying and stacking the same in pwd chowky or as directed etc. complete. , supplying and erecting high density polythene pipe isi mark 32 mm dia suitable for pressure of 6 kg/cm2 connected to jet/submersible pump with required material complete. , supplying and erecting mains with 2x4 sq mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. wg-ma/bw , m5 box for starter , material & labour for vinyl painting of matter given by dept, in diff, colour as per rc , add gst 18% , e)providing,supplying and comissioning of reverse osmosis system 250 litre magaswargiy wasti at falwani tal malshiras
  • View Tender
  • Document
  • Bid Support
4 Crude Oil/Natural Gas/Mineral Fuels
image image
Central Government/Public Sector
TRN :49020788 |  21 May, 2025
Tender Value : 0
 Manali - Tamil Nadu
Tender for procurement of anti-static additive for atf (7254 kg - single delivery) , anti static additive for atf , (i)in case of igst supplies, the applicable igst(%) shall be indicated clearly against sl.no. 14 , (ii)in case of cgst & sgst, applicable cgst(%) & sgst(%) shall be indicated clearly against sl.no. 12 & 13 respectively.
  • View Tender
  • Document
  • Bid Support
5 Security Services
image image
Central Government/Public Sector
TRN :34439631 |  16 May, 2025
Tender Value : 0
 Nasikcity - Maharashtra
Tender for gem bids for 6 pcs mini pliers set , 3 pcs pliers set , rubber hammer , rubber plastic hammer , combination spanner set , 14 pcs screwdriver set , mini hacksaw , 9 pcs hex key , 6 inch adj wrench , 8 inch adj wrench , 6 pcs needle file set , electricians scissors , 115 pcs tools set drill , 12 pcs 1 4 inch socket set , flexible screwdriver set 12 pcs , hacksaw frame big , 4v cordless screwdriver , snap off and cutter blade , tool box plastic 16 inch , tool box metal 18 inch , wire stripper , 55 pcs screwdriver bits set , tweezer set 10 pcs anti static , 9 pcs hex key set , cordless blower 20v , cordless vacuum cleaner 20v , cordless mini cut-off tool 20v , grinder cordless , laminate router trimmer 500w , finishing sander , air compressor 24 lit , air spray gun , 5 pcs extractor set , high pressure washer 1200w , soldering station 60w , digital multimeter , lithium ion battery pack 2.0 ah 20 volt , lithium ion battery pack 4.0 ah 20 volt , mini grinder , jig saw , jig saw blade set , 7 pcs pliers set , thermocol foam cutting machine , f clamps 50x 250mm , f clamps 50x150mm , cg clamps 6 inch , cg clamps 4 inch , grinding wheel 4 inch set of 10
  • View Tender
  • Document
  • Bid Support
6 Security Services
image image
Central Government/Public Sector
TRN :34413160 |  13 May, 2025
Tender Value : 0
 Visakhapatnam - Andhra Pradesh
Tender for gem bids for procurement and installation for upliftment of office space for static test facility 3d mural work with department silhouette , plaque for commissioning crew , acrylic poster 24 18 with stud fitting , acrylic motivational wall posters of 18 12 with stud fitting , pleated acoustic wall paneling with medium density fiberboard slants made of melamine laminated finish with perforated groove slants , textured embossing with dual layer putty and single coat primer and dual layer emulsion , texture vinyl layering anti skid double layered with wooden finish , flag post with flags , customized rope light fixtures for ceiling lightning in officer in charge cabin and conference hall , ceiling embossing with gypsum sheet and 18mm channel and finished with dual coat putty , ceiling emulsion dual layering with multi coat finish , customized toughened glass entrance with dept crest etching on both sides , indoor plants for lobby corridor waiting lounger conference room and other areas , name tallies for all cabins rooms , 54inch height toughened glass side wall for open porch area shatter proof and double strengthened for safety , toughened glass white board with waterproof makers 36 48 , toughened glass white board with waterproof makers18 24 , overhead profile ceiling beside visitor area and guard room 14 16 8 8 based on self drilling screw finished with dual coat of anti rust coating , zebra blinds screen roller with nai logo underneath on all windows , 2d mural painting of naval history with dept crest and navy crest on either side 160ft 30ft as per approved design
  • View Tender
  • Document
  • Bid Support
7 Education And Research Institutes
image image
Central Government/Public Sector
TRN :34414414 |  13 May, 2025
Tender Value : 0
 Mysore - Karnataka
Tender for gem bids for soldering station , torque screwdrive set , esd grounding kit anti static wrist strap belt , soldering desk magnifier with light , smoke absorber , component organizer storage box , 58 piece screwdriver set , 110 in 1professional precision screwdriver set , k100ld lead free wire solder , hot air gun , solder flux , hot melt glue gun with glue sticks , wire stripper , desoldering pump , pcb holding hands , anti static tweezers set , ipa isopropyl alcohol 250 ml
  • View Tender
  • Document
  • Bid Support
8 Security Services
image image
Central Government/Public Sector
TRN :34399172 |  10 May, 2025
Tender Value : 0
 Ernakulam - Kerala
Tender for gem bids for 690 anti static flooring mat conductive grade blue brown with grounding arrangement on bus bar
  • View Tender
  • Document
  • Bid Support
9 Housing Urban And Rular Development
image image
Local Bodies
TRN :48606691 |  15 May, 2025
Tender Value : 56.65 Crore
 Prayagraj - Uttar Pradesh
Tender for tender for kareli - nurulla road to askari market road block c and block d housing scheme and nurulla road from mahavir chauraha to karamat ki chowki near sasur khedari river and also till the connecting road - clearing grass and removal of rubbish upto a distance of 30 m outside the periphery of the area as per technical specification clause 201. 3 dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including t&p and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 60 metres as per instructions of e-i-c. (by mechanical means). 4 i) cement concrete 5 ii) reinforced cement concrete/ r.b. 6 dismantling of flexible pavements and disposal of dismantled material up to a lead of 100 m, stacking serviceable and unserviceable materials separately as per technical specification clause 202. bituminous / granular courses (by mechanical means) 7 dismantling of road gully chamber of various sizes including c.i. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 8 removing all type of hume pipes and stacking within a lead of 1000 metres including t&p, earthwork and dismantling of masonry works. 9 (i) up to 600 mm dia 10 removal of telephone / electric poles / street light / lamp post including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately 11 disposal of moorum/building rubbish malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of engineer-in-charge. note- item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. 12 dewatering using 10hp to 70hp diesel engine pump set including hire charges, cost of diesel, engine oil, pump operator, labor charges, conveyance of pump set and fuel to site and back, loading, unloading and any other incidental charges etc., complete. (hire charges for diesel pump set for 10 hp) 13 [b] bill no. 2 - earthworks 14 excavation for road work in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and leading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections and transporting to the embankment location within all lifts and lead upto 1000m 15 removal of unserviceable soil including excavation loading and disposal but excluding replacement by suitable soil which shall be paid separately as per clause 305 16 i) lead upto 1000 m 17 ii) lead upto 8000 m 18 earth work in excavation of foundation of structures as per drawing and technical specification, including setting out construction of shoring and bracing, removal of stumps and other deleterious matter dressing of sides and bottom, backfilling the excavation earth to the extent required and utilizing the remaining earth locally for road work. 19 mechanical means (depth upto 1.5 m) 20 i) excavation 21 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 22 [c] bill no. 3 - development of carriageway 23 stabilization of in-situ (existing pavement crust) or soil or otherwise sub base/ base course up to the required depth by cold in-situ recycling using cement and chemical additives / otherwise: providing pulverizing, spreading, milling and mixing of chemical additives at the appropriate rate as per job mix design in accordance with irc-sp-72-2015 , irc-37-2012 & 2018 and irc sp 89 (part ii) 2018. cementitious additive @ rate of minimum 5 - 7% and ccs/cs additive should be spread on the existing pavement using a mobile truck mounted containerized cement/ additive spreader with micro processor controlled weighing and spreading system. the additive spreader shall have variable working width sufficient to cover whole pavement lane. the in-situ stabilization process shall be carried out by a mobile and self propelled stabilizer / reclaimer of working width of 2.4 m and with minimum engine horse power of 440 kw with a variable working depth up to 50 cm. the resultant stabilized mix then would be profiled to the required grade, level and thickness using motor grader and the mix would be compacted using 20 tonne pad foot roller in combination with smooth wheel roller to achieve desired proctor density as per irc 37-2012 & 2018 and complete in all respect and curing with water as required including all materials, labour and machinery etc. the entire in-situ process would be carried out in single pass with milling and pulverising of damaged asphalt pavement / soil/ aggregates / soil-aggregate mixture to the desired depth and with simultaneous addition of additives and water with machine integrated spray bars fited on the wheeled self-propelled and vibratory pad foot roller to achieve the desired proctor density in all respects. the tandem roller be followed by pneumatic tyre roller. the minimum unconfined compressive strength (ucs) of stabilized sub base/ base should be 4.5 to 7 mpa after 7 / 28 days of curing as per irc-sp- 72-2015 , irc-37-2012 & 2018 . also durability aspects (wet-dry cycles) of stabilized sub base should be satisfied as per irc 37-2012 & 2018 and irc sp 89 (part ii) 2018. the gradation mixes and materials should be as per irc 37-2012 & 2018 and irc sp 89 (part ii) 2018. the train of equipments to be used are binder spreader- water tanker- additive truck- recycler- padfoot roller (20 tonne) + single drum compactor- grader- tandom roller- pneumatic tyreroller (20 tonne) 24 sami layerproviding and laying stress absorbing membrane interlayer (sami)/bitumen impregnated geotextile layer after clearing of the road surface geotextile conforming to physical requirements of claues 703-3, laid over a tack coat of paving grade bitumen 80- 100 penetration, laid at the rate of 1.05 kg per sqm over thoroughly cleaned and repaired surface to provide a water resistance membrane and crack retarding layer paving fabric to be free of wrinkling and folding and to be laid before cooling of tack coat, brooming and rolling of surface with pneumatic roller to maximise paving fabric contact with pavement surface. 25 providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 to 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. (tack coat on bituminous surfaces ) 26 providing and laying 40mmthickbitumencarpete(b.c.) with 100-120 tph hot mix plant producing and average output of 75 tonege par hour using crushed aggregates of specified grading premixed with bitumen binder(vg-30) @ 5.40% of mix as per most specification clause. etc all comp of work. 27 providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from aggregat aggregate natural sources, portland pozzolana/ordinary portland/portland slag cement, admixtures in recommended proportions as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads as per direction of the engineer-in-charge; for the following grades of concrete.note: extra cement up to 10% of the minimum specified cement content in design mix shall. be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 28 m.s. (tor steel or plain) in plain work such as rcc or rb work including binding for proper shape and including supply of steel and its wastage bend, hooks and authorized overlapping shall be measured and including cost of binding wire. excluding gst (sor-504). 29 [d] bill no. 4 - pedestrian infrastructure (footpath) 30 sand filling in foundation trenches as per drawing & technical specification and as per direction of engineer-in-charge. (including beneath all paver blocks, cobble areas for levelling purpose, etc.) 31 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. (pcc below all paving area, kerb channel, road edge kerb, table top, property edge beam) 32 construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at omc, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (by mix in place method) 33 i) for grading-i material 34 plain/reinforced cement concrete in open foundation complete as per drawing and technical specifications, pcc grade m30using batching plant transit mixer & manual placing(80 mm thickness) r & manual placingand giving broom finish. (pcc with broom finish thickness 80 mm) 35 providing and laying 75mm thick m-30 grade batch mix cement concrete and applying stamping finish to the top surface of freshly laid plain/ reinforced cement concrete of specified grade in porticos, sidewalks, driveways, pool decks and open yards as per direction of the engineer-in-charge. the process shall include the following:-the concrete shall be placed and screeded to the finished grade, and floated to a uniform surface by using standard finishing techniques. the approved color hardener @ 2.7 kg/sqm shall be applied evenly to the surface of the fresh concrete by the dry shake method by sprinkling in two or more shakes, floated after each shake and trowelled only after the final floating. the approved release agent @ 0.113 kg/sqm shall be applied evenly to the trowelled surface before stamping or the said release agent can be applied to the flexible polyurethane stamp moulds of approved design and in required sizes to achieve final stamped pattern. these stampings shall be placed on the surface of concrete in three to four pieces at a time and tapped gently with rammers of sufficient size & weight to leave proper stamp marks and the process repeated for the remaining concrete surface till the hole surface to be stamped is completed within the time while concrete is in plastic stage of setting.after stamping, the curing shall be done as per manufactures specifications. after initial curing the imprinted joints shall be grouted using cement slurry mixed with color hardener as per theequirement. the surface shall be sealed by applying acrylic based sealer not less than 0.167 litre/sqm.on finished surface.the construction joints shall be provided by groove cutting of size 4mm x 20mm in panel size 3m x 3 m or lesser as per the site conditions and filling the same with 10 mm baker rod and providing and laying (pu) polyurethane based joint sealer of approved make as per manufacturer’s specifications and finished by applying polyurethane resin based top protective clear coat of minimum 80 micron applied with rollers on properly cured and dry clean surface. (cost of concrete for flooring is not included in this item which shall be paid separately.) 36 80 mm thick c.c. paver block of m-35 grade with approved color design and pattern. 37 supply and fixing of tactile indicators made from ss-304 grade stainless steel. warning tactile indicator shall be installed on the walking surface in a raised grid pattern of dots or stud. minimum 36 studs to be placed in 300x300 mm area. dimensions - 35mm outer dia x25mm inner dia, stem dia 8mmx12mm, weight - 28grm.all the indicator will be installed into correctly drilled holes and place any suitable adhesive, all the indicators shall be aligned property, all complete as per direction of engineer-in-charge. 38 supply & fixing of tactile indicators made from ss-304 grade stainless steel. directorial tactile indicator shall be installed on walking surface, consisting of a series of raised bar/strip. min 4 bars/strip to be placed in direction perpendicular to distance of travel in 300x300 mm area. dimensions-280mm l x 35mm w x 4.5mm, stem dia 8mmx12mm, weight - 250grm all the indicator will be installed into correctly drilled holes and place any suitable adhesive, all the indicators shall be aligned property., all complete as per direction of engineer-in-charge. 39 providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to is : 15622 of approved make in all colors and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of engineer-in-charge 40 chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (dsr-11.20) 41 providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of engineer-in-charge. (saucer drain along the road edge, curved kerbs at property entry/exit, curved kerbs at side roads) 42 providing and laying at or near ground level factory made kerb stone of m-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment). (precast c.c. kerb stone shall be approved by engineer-in-charge). 43 cc grade m20 using batching plant transit mixer & manual placing all complete as per direction of e-i-c. 44 [e] bill no. 5 -parking 45 construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at omc, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (by mix in place method) 46 i) for grading-i material 47 supplying and filling in plinth with sand under floors/in trenches, including watering, ramming, consolidating and dressing all complete with material (from source to site), labor and t&p etc. required for proper completion of the work. (including royalty). 48 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days and giving broom finish. (pcc) 49 providing and laying factory made chamfered edge cement concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using pu mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of engineer-in-charge.80 mm thick c.c. paver block of m-35 grade with approved color design and pattern. 50 [f] bill no. 6 -cycle track 51 nil 52 [g] bill no. 7 - traffic signs, markings and other road appurtenances 53 providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow ms tube posts/horizontal members/bracings covered with 1.63mm thick ms sheet. the sheet shall be fixed with 30x5mm ms flat by suitable welding/riveting. the panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. ms channel islc 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long ms angle 40x40x6mm bracing. suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. the work shall be executed as per drawing/direction of engineer-in-charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the engineer-in-charge. the barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. the barricading shall not be removed without prior approval of engineer[1]in-charge.(note :- one time payment shall be made for providing barricading from start of work till completion of work i/c shifting. the barricading provided shall remain to be the property of the contractor on completion of the work). 54 reflective raised pavement markers (cat eye/ road stud) supply and fixing of raised pavement marker with made of plastic body of rpm/ road stud shall be moulded from asa (acrylic styrene acrylonitrile) or hips (high-impact polystyrene) or acrylonitrile butadiene styrene (abs) or any other suitable material approved by the engineer. the marker shall support a load of 13,635 kg tested in accordance with astm d4260. the reflective panels shall consist, of number of lenses containing single or dual prismatic cubes capable of providing total internal reflection of the light entering the lens face. lenses shall be moulded of methyl methacrylate conforming to astm d788 of equivalent. the slop or retro-reflecting surface shall preferably ba 5+/.5 degree lo base and the area of each retro -reflecting surface shall not be less than 13.00 $q.cm. the marker height shall not be less than 10 mm and shall not exceed 20 mm & width shall not exceed 130 mm the base of the marker shall be flat within 1.3 mm all road studs shall be legibly marked with the name trade or other means of identification of the manufacture. epoxy installations, excess adhesive around the edge of the marker, excess adhesive on the pavement and adhesive on the exposed surfaces of the markers shall be immediately removed. the contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel , to the engineer . in addition , a two year warranty for satisfactory infield performance of the finished road marker shall also be given by the contractor who carries out the work of fixing of reflective road markers. in case the markers are, displaced , damaged . get worn out or lose their reflectivity compared to stipulated standards , the contractor would be required to replace all such markers within 15 days of the intimation from the engineer , at his own cost. the rate shall include all materials, labor, t&p, transportation, installation and incidentals all complete as per direction of the engineer-in-charge, 55 rpm with shank 56 solar power road marker the solar studs shall be made of aluminum alloy and polycarbonate material which shall be absolutely weather resistant and strong enough to support to load of 13,635 kg tested in accordance with astm d4280. its color may be white, red, yellow, green or blue or combination as directed by the engineer. its water resistance shall meet the requirements of ip 65 in accordance with is: 12063:1987 category 2 for the protection against water ingress. the dimensions of solar studs shall not be less than 100 mm * 100 mm * 10 mm. it shall have super bright leds so as the provide long visibility from a distance of more than 800 m. its flashing rate shall not be less than 1 hz. its should be able to give the prescribed performance in the temperature range of -40 degree c to +55 degree c. its life shall be not less than 3 years. the rate shall include all material, labor, equipments, fabrication, transportation erection, installation and incidentals all complete as per direction of the engineer-in-charge 57 r.cc work (1:1.5:3) (m-20) with cement course sand &20mm the stone grit including all complete cement concrete with cement sand &20mm gauge stone grit with the proportion of (1:1.5:3)including all complete the work (morth ra-12.8 c, case-ii) 58 m.s. or iron work plain or tor for rcc work including cutting, bending, rivetting or welding etc. where necessary. excluding gst (s.i.no-504) 59 painting two coats on new concrete surfaces - painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces 60 m.s. or iron work of heavy sizes section such as trusses, built up gates, record racks, roof work, gates etc. including rivetting or welding where necessary. excluding gst (s.i.no-503) 61 painting of m.s. grill with enamul paint etc all complete work. (s.i. 15.15 new item no.) 62 providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, t&p, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of engineer-in-charge and accordance with applicable specifications. 63 providing and fixing of retro- reflectorized cautionary, mandatory and informatory sign as per irc :67 made of high intensity grade sheeting type-ivvide clause 801.3, 2mm thick aluminum sheeting, 1.5 mm thick supported on mild steel angle iron post 75mm* 75mm *6mm firmly fixed to the ground by means of properly designed foundation with m15 grade cement concrete 45cm* 45cm*60 cm, 60 cm below ground level as per the approved drawing. the retroreflective sheeting shall be tested for a certificate of having the sheeting coefficient of retro reflection, daytime, color and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoors weathering and its having passed these tests shall be obtained from international/ government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should be also obtained from indian condition within 3 years of launching ofproduct by the manufacturing abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirement from a reputed laboratory in india can be accepted provisionally. in such a situation , the employer/client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of 3 years outdoor weathering of the sheeting as per irc 67:2012 . legends, letters, numerals, and borders etc. should be as per mort&h specification 801.3.7. proof of the same in form of government reports shall be uploaded while quoting tender. 64 90 cm equilateral triangle with diffinitation plate size (20cm x 60 cm) 65 60 cm equilateral triangle with diffinitation plate size (20cm x 60 cm) 66 60 cm circular with diffinitation plate size (20cm x 60 cm) 67 80mm x 60mm rectangularwith diffinitation plate size (20cm x 60 cm) 68 60 mm x 45 mm rectangularwith diffinitationplate size (20cm x 60 cm) 69 60cm x 60cm square with diffinitation plate size (20cm x 60 cm) 70 90 cm high octagon 71 direction and place identification signs up to 0.90 sqm size board providing and erecting direction and place identification retro-reflectorized sign as per irc-67 made of high intensity grade sheeting the retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime color and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from international/government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally. in such a situation, the employer/ client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per irc 67:2012. legends, letters, numerals and borders etc. should be as per mort&h specification no-801.3.7. sheet fixed over aluminum sheeting 2 mm thick with area not exceeding 0.9 sqm. supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with m-15 grade cement concrete 45x45x60cm., below ground level as per approved drawing, complete. 72 direction and place identification signs with size more than 0.90 sqm size boardproviding and erecting direction and place identification retro-reflectorized sign as per irc-67 made of high intensity grade sheeting the retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime color and luminance, shrinkage, flexibility. liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from international/government laboratory/ institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. alternatively, a certificate conforming to astm specification (d4956-09) on artificial accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally. in such a situation, the employer/client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per irc 67:2012. legends, letters, numerals and borders etc. should be as per mort&h specification no-801.3.7. sheet fixed over aluminum sheeting 2 mm thick with area exceeding 0.9 sqm. supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with m-15 grade cement concrete 45x45x60 cm below ground level as per approved drawing, complete. 73 providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans & as per irc :67 74 brick masonry work in cement mortar 1:4 (1cement: 4 coarse sand) in foundation complete with cement concrete bricks procured from c&d waste recycling plant baswar excluding pointing and plastering, as per drawing and technical specifications. 75 struck pointing with cement mortar consisting of 1 part cement and 2 parts of fine sand of 1.25 finerness modulus.sor 2022 si no574 76 12 mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement :3 sand)and as per direction of engineer in charge. 77 finishing walls with ready mixed premium acrylic emulsion paint (company depot tinted) having volatile organic compound (voc)less than 50 gm/liter and uv resistance as per is 15489:2004, alkali, & fungal resistance, dirt resistance exterior paint of required shade with silicon additive(for painting wall, street furniture) new work (two or more coats applied @1.43 liter/10sqm over and including priming coat of exterior primer applied @ 0.90 liter/10 sqm) 78 supplying and fixing of cast iron antique style bench having weight of sides not less than 72 kg (36 kg each) fitted with fibre rectangle strip (should not be less than 50 mm x 25 mm and 1.6mm thick. length of bench should not be less than 6 ft (end to end of castiron support). 79 [h] bill no. 8 - utility and street light cabling 80 plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.(pcc below pipe of storm water, sewer, water, inspection chamber for storm water, telecom chamber, power chamber and sewer) 81 providing and laying non pressure np-3 class (medium duty) r.c.c. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete (storm water, sewer) 82 600 mm dia rcc pipes 83 providing of 7- way 40mm multi ducts with solid permanently solidly lubricated silicone in inner layer for ict fiber cables conforming to astm f 2160, astm d 2444 and /or equivalent indian standard. external sheathshall be in orange colorand shall be free from visual defects like blisters, shrink holes,flaking, scratches, groove lines & surface roughness. the color of the 7 nos. plb hdpe ducts shall be green, blue, yellow, brown, violet, grey , red for differentiation. outer sheet thicknessshall be 1.2mm +/-0.2mm. the inner surface of the multi channel ducts shall be spirally ribbed & shall be of a configuration for faster installation of cables. wall thickness(mm) of each of the ducts excluding rib height shall be 2.9mm +/- 0.3mm. iso requirements- iso 9001, 14001, 18001, complete as per specifications and directions of engineer-in-charge. (7 way multi utility duct for ofc) 84 supply of hdpe pipe of size 110mm for distribution system conformingn to latest/ relevant i.s. 4984/1995 specifications with all jointing materials and specials conforming to latest /relevant i.s. specifications including f.o.r. destination and all taxes and insurance etc. with loading, unloading and carting up to site of work, also including specials for these pipes and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete (including testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches) all complete as per instructions of engineer-in-charge.110mm dia hdpe pipe pn-6 class pe-100 85 supply of hdpe pipe of size 63mm for distribution system conformingn to latest/ relevant i.s. 4984/1995 specifications with all jointing materials and specials conforming to latest /relevant i.s. specifications including f.o.r. destination and all taxes and insurance etc. with loading, unloading and carting up to site of work, also including specials for these pipes and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete (including testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches) all complete as per instructions of engineer-in-charge.63mm dia hdpe pipe pn-6 class pe-100 86 rcc grade m20 using batching plant transit mixer & manual placing ( side wall, bottom slab for all inspection chamber i.e. storm water, telecom, power, sewer, water) 87 supply and installation on site - recessed double seal ofwith a clear opening of750*750 mm di manhole cover and frame(material- ductile iron grade 500/7) of class b125 having minimum load capacity 125 kn load as per en124-2, the top cover( should have 2 no. of keyholes ) as per the design approved by engineer in chargedesign approved by engineer in charge. 88 supply and installation on site - recessed double seal ofwith a clear opening of750*750 mm di manhole cover and frame(material- ductile iron grade 500/7) of class d400 having minimum load capacity 400 kn load as per en124-2, the top cover( should have 2 no. of keyholes ) as per the design approved by engineer in chargedesign approved by engineer in charge. (storm water) 89 supply and fixing gully grates red 048 grh – 300* 750mm d.i. gully grate & frame in d400 load class , as per bs en 124 black bitumen paint, all complete as per direction of engineer-in-charge. 90 constructing rcc rectangular type manholewith a floating coat of neat cement, foundation concrete 1:6:12mix (1 cement : 6 coarse sand : 12 graded brick bats 40 mm nominal size), and making necessary channel in cement concrete of m-25 grade finished with a floating coat of neat cement, all complete as per standard design and instruction of e-i-c. 91 restoration of water pipeline in case of damage 92 [i] bill no. 9 - horticulture / landscaping works 93 trenching in ordinary soil up to required depth including removal and stacking of serviceable materials and then disposing of as directed and spreading earth & neatly levelling, breaking clods etc. and making the trenched area with designed mounds, paths and sitting spaces etc. to proper levels by filling with earth or earth mixed with manure and properly watering complete work in required topography as per drawing & specifications. 94 supplying and stacking of good earth at site including royalty but including carriage1km (earth measusred in stacks will be reduced by 20% for payment). 95 supplying and stacking at site dump manure from approved source,including carriage up to 1 km (manure measured in stacks will be reduced by8% for payment) 96 mixing earth and manure in specified proportion or as directed. 97 rough dressing the trenched ground including breaking the clods. 98 fine dressing the ground 99 spreading ofmixed good earth and manure in specified proportions as above and in required thickness. 100 uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation. 101 providing & laying selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge 102 preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of officer-in-charge. 103 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete. 104 providing and stacking of nauclea cadamba (kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge. 105 providing and stacking of nyctanthes arbor-tristis (hasingar) of ht. 90-105 cm in earthen pots of size 20 cm as per direction of the officer-in-charge. 106 providing and stacking of terminalia arjuna of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. 107 providing and stacking of plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size hdpe bags as per direction of the officer-in-charge. 108 providing and stacking of plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size hdpe bags as per direction of the officer-in-charge. 109 providing and stacking of ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. 110 providing and stacking of ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.. 111 providing and stacking of duranta golden, having ht.15 to 20 cm bushtyshape with fresh and healthy leaves in 15 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge.. 112 providing and stacking of tradescantia zebrina having in 15 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge. 113 providing and stacking of wedelia trilobata,full of leaves in 15 cm size ofpoly bags & as per direction of the officer-in-charge. 114 providing and stacking of asparagus sprengeri of height 30 cm to 45 cm, full of leafy branches in 15 cm size of earthen pot / plastic pot & as per direction of the officer-in-charge.. 115 providing and stacking of ophiopogon jaburan ( variegated ), full of variegated leaves in earthen pot/plastic pot of size 20 cm. as per direction of the officer-in-charge. 116 providing and displaying of croton petra bangalore variety having ht. 60 cm to 75 cm with 4 to 6 branches, well developed, fresh and healthy colorful leaves in 25 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge. 117 providing and fixing ms iron tree guard 60 cm dia and 2 metre high above ground level formed of 4 nos (25 x 6 mm) and 8 nos (25 x 3 mm) vertical ms riveted to 3 nos (25 x 6 mm) iron rings in two halves, bolted together with 8 mm dia and 30 mm long bolts including painting two coats with paint of approved brand over a coat of priming, complete in all respects. 118 street light works (excluding gst) 119 supply & fixing of 9 mtr gi octagonal pole of approved make (top dia 70mm, bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 mtr length) on rcc foundation including the cost of foundation, foundation bolts, excavation & back filling and required t&p complete in all respect 120 supply and fixing of led street light fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 watt. confirming to ip 66 protection complete in all respect. cat: aaa 121 supply and laying of 16 sq.mm. 4 core aluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer-incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 122 supplying and laying 6 swg g.i. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with gi thimble etc. as required. 123 supply and burring of safe earthing electrode t-39 (hot-dip galvanized), length up to 3000mm, outer pipe 76mm inner dia38mm terminal dia 12 mm ,outer gipipe of 16 swg and inner gi pipe of 12 swg withhot dip galvanization up to 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. frame with hinged cover & masonary housing. (from electrode terminal to switch board, cost of 25 x 3 gi. strip will be extra) make: as approved in u.p. p.w.d., & c.p.r.i. certified. 124 making connection of each street light by s/l 1.5 sqmm frlsh copper wire complete as per direction of engineer in charge. 125 supply & fixing of 9 mtr gi octagonal pole of approved make (top dia 70mm, bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with double arm bracket (1 mtr length each ) on rcc foundationincluding the cost of foundation, foundation bolts, excavation & back filling and required t&p completee in all respect. 126 supply & laying of 63 mm dia (od-63 mm & id- 51 mm nominal) dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers, etc. conforming to is 14930, part ii complete with fitting and cutting, jointing, etc. direct in ground (75 cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc, complete as required. 127 supply and fixing for automatic street light cubical control juction box painted with anti-corrosive alkali and acid proof pait consisting of 6 amps mcb (b - curve) complete in all respect 128 supply and fixing of 16 sq.mm plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer-incharge. 129 supply and fixing of 40 amp. capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors, hrc fuses, isolating switch metering instrument & instrument box with cts etc. in case of tpn, complete in all respect. 130 supply and laying of 32 mm x 6 mm g.i. strip from earth electrode directly in the ground as required complete in all respect. 131 supply/ erection of surface mounted decorative pole 4500 mm long having base plate 300x300x12 mm with the bottom dia 139 mm upto 1 mtr long with the thickness of 3.6 mm and the top dia is 76 mm upto 3.5 mtr. log. decorative pole made out of galvanized iron tube with cast aluminium embellishments. the poles are painted with polyturetnane paint. the pole have service window at the bottom on the pole for housing the mcb and terminal strips and as per attached drawings. 132 s/f of single arm decorative bracket 100 mm long made of cast iron/ aluminium embellishments painted with polyturetnane paint. 133 supply of led decorative drop down light made of aluminium housing fitted with polycarbonate diffuser having 500 mm dia with 70 w. 134 supplyandlayingof aluminiumconductorpvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer-incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core 135 supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors, hrc fuses, isolating switch metering instrument & instrument box with cts etc. in case of tpn, complete in all respect. 40 a tpn 136 supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer-incharge. 16 sq. mm 137 supply & laying of 63 mm dia (od-63 mm & id- 51 mm nominal) dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers, etc. conforming to is 14930, part ii complete with fitting and cutting, jointing, etc. direct in ground (75 cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc, complete as required. 138 supply and laying 6 swg g.i. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with gi thimble etc. as required. 139 supply and burring of safe earthing electrode t-39 (hot-dip galvanized), length up to 3000mm, outer pipe 76mm inner dia38mm terminal dia 12 mm ,outer gipipe of 16 swg and inner gi pipe of 12 swg withhot dip galvanization up to 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. frame with hinged cover & masonary housing. (from electrode terminal to switch board, cost of 25 x 3 gi. strip will be extra) make: as approved in u.p. p.w.d., & c.p.r.i. certified. 140 part - b utility shifting (including gst) 141 converstion of lt overhead line by underground lt line 142 lt xlpe insulated cable of size 3.5x400 sqmm. 143 lt xlpe insulated cable of size 3.5x240 sqmm. 144 lt xlpe insulated cable of size 3.5x150 sqmm. 145 lt xlpe insulated cable of size 3.5x70 sqmm. 146 9 mtr long stp 147 hdpe pipe 140mm dia peb0, pn-6 148 hdpe pipe 120 mm dia peb0, pn-6 149 hdpe pipe 75 mm dia p880, pn-6 150 aluminium crimping lugs 400sqmm 151 aluminium crimping lugs 240sqmm 152 aluminium crimping lugs 150sqmm 153 aluminium crimping lugs 70sqmm 154 6 swg g.l. wire for earthing along cables. 155 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x400 sqmm. lt cable 156 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x240 sqmm. lt cable 157 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x150 sqmm. lt cable 158 cable end termination using total double compression brass glands and crimping type cu. thimbles for 3.5x70 sqmm. lt cable 159 main lt panel at sub station- 400 kva (type a-2)lncomer- 1 set of 800 amp. tp mccb with spreader & extended handlemetering on lncomer - 1 set of digital ammeter with ass- 1 set of digatal voltmeter with vss- 1 set of led type phase lndicating light (22.5 mm.)with control mcbsoutgoing- 6 set of 250 amp. tp mccb with spreader & extended handte( 5 nos. + 1 no. for capacitor panel)- 2 set of 100 amp. tp mccb with spreader & extended handle 160 main lt panel at sub statton- 250 kva (type a-2) lncomer- 1 no. 630 amp. tp mdo acb with inbuilt mpr release with i ontoff tnai.ating lightmetering on lncomer - 1 set of digital ammeter with ass- i set oldigital volt-meler wirh vss- 1 set of led type phase indicating light (22.5 mm.j with control mcbs outgoing - 5 set of 250 amp. tp mccb with spreader & exrended handle- 2 set of 100 amp. tp mccb with spreader & extended handle flnstallation oflt distribution boards for lt underground system (type a,b&cj) 161 supply , installation, testing & commissioning of outdoor type feeder pillar panetto be made of 2 mm crca sheet and covers will be j.6mm crca sheet dulypowder coated paint with 300 amps al. busbar. (type-b2)lncomer - 250 amp. tp mccb - 1 no.outgoing - 63 amp. tp mccb - 5 nos.lnstallation of lt distribution boards forlt underground system (type-a, b & c) 162 outdoor type feeder pillar panel to be made of 2 mm crca sheet and covers will be 1.6mm crca sheet duly powder coated paint with 300 amps al. busbar. [type-b3] incomer - 100 amp. tp mccb - 1 no. outgoing - 63 amp. tp mccb - 4 nos.lnstallation of lt distribution boards for lt qnderground system [tvpe-a, b & cl 163 lockable distribution boxes of size 450x400mm with bus bar 100 amp. tpn to feed upto 10 houses (type c) 164 xlpe lt service armoured cable for single phase,2x6 sq. mm.(pvc armoured consumer service cablel 165 xlpe lt service armoured cable for single phase,2x10 sq. mm.(pvc armoured consumer service cablej 166 xlpe lt service armoured cable for three phase,4x10 sq. mm.[pvc armoured consumer service cablel 167 xlpe lt service armoured cable for three phase,4x1.6 sq. mm.(pvc armoured consumer service cablel 168 xlpe lt service armoured cable for three phase,4x25 sq. mm.(pvc armou[ed consumer service cable) 169 pvc pipe 32 mm dia 170 pvc pipe 50 mm dia 171 electronic kwh meter 1px2w with box. for single phase consumer 172 electronic kwh meter 3px4w static meter with box.for three phase consumer 173 carriage , laying of 3.5cx400 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 140 mm dia. 174 carriage, laying of 3.5cx150/240 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 1.20 mm dia. 175 carriage ,laying of 3.5cx70 sq.mm size lt xlpe insulated cable underground in hdpe pipe size 75mm dia. 176 painting of stp incuding paints [2 ltr red oxide and 2 ltr alluminum paint for each pole.l 177 grouting of st pole 178 cartage , erection and dismentling charges 22% of materials cost 179 conversion of 11kv overhead/underground line by 11kv line underground 180 11 kv cable size 3x185 sq.mm xlpe 181 stp 11m-is 410 sp-55 182 g.l pipe 4 dia 183 top channel 100x50x2240 mm 184 hdpe pipe 160 mm dia pe 80, pn-6 185 service clamp o/s 186 clamp for fixing pipe to pole 187 11 kv cable jointing kit size 3x185 sq.mm xlpe o/d 188 11 kv cable jointing kit size 3x185 sq.mm xlpe s/t 189 earthing complete. 190 m.s. nut & bolt with washer 191 bracing angle 65x65x6x2700 mm with clamp 192 stone pad 193 number plates with clamp 194 danger board & clamp with bolts & nuts 195 stay complete 196 g i barbed wire 197 carriage , layrng of 3x185 sq.mm size 11 kv xlpe insulated cable underground in hdpe pipe dia 160 mm. 198 painting of stp incuding paints (2 itr red oxide and z lt. allrn inrm pal,1t for each pole.) 199 grouting of st pole 200 grouting of stay set 201 cartage , erection and dismentling charges 22% of materials cost 202 conversion of 33kv overhead/ underground line by 33kv line underground 203 cable al. 3x300 sq.mm. xlpe 33 kv 204 stp 11m-is 410 sp-55 205 g.l pipe 6 dia 206 m.s.top channel 100x50x2240 mm 207 hdpe pipe 200 mm dia pe 80, pn-6 208 service clamp o/s 209 clamp for fixing pipe to pole 210 bracing angle 65x65x6x4300 mm with clamp 211 33 kv cable jointing kit 3x300 se mm outdoor 212 33 kv cable jointing kit 3x300 se mm straight through 213 earthing of pole by ms earthing rod of 2ox25o0 mm & 6 swg earthr.ng wire etc. 214 m.s. nut & bolt with washer 215 number plates with clamp 216 danger board & clamp with bolts & nuts 217 stay complete (stay rod 15x1800mm, stay wire 5 kg,, stay clamp, boult & nut rvith grouting 218 daner bqard barbed wire includin jumpering 219 carriage , layrng of 3x300 sq.mm size 33 kv xlpe insulated cable underground in hdpe pipe dia 200 mm. 220 painting of stp incuding paints (2 itr red oxide and z lt. allrn inrm pal,1t for each pole.) 221 grouting of st pole 222 grouting of stay set 223 cartage , erection and dismentling charges 22% of materials cost 224 installation of 250 kva transformer on dp for the shifting of 3 no. 250 kva. 9 no.400 kva & 3 no. 630 kva transformer 225 stp 11m-is 410 sp-55 226 ms channel 100x50x2240 mm 227 service clamp for round pole 228 m.s. bolt and nuts off size with washer 229 l.t. cable 3.5ox4oo so m 230 ltxlpe insulated,unarmoured aluminium singlc corc cable,1x240sq. mm.sizc 231 lt xlpe insulatcd,unarmoured aluminium singlc core cablc,1x400 sq. mm.size 232 earthing of 250 kva t/f with g.i. pip[ 233 earthing rod complet. 234 1 1 kv d.o. fi]se sets 235 1 1 kv tpmo 236 d.d. wire 70 qs mm 237 250 kva t/f 238 l.t. cubical b0x complete 239 l,t. cable 3.50x240 sq mm 240 stay set complete, 241 aluminimum lug 70 sqmm 242 aluminimum lug 240 sqmm 243 aluminimum lug 400 sqmm 244 pvc tape 245 t/f bushing connector of copper strip 246 labour , cartage & errection charges and dismentaling of existing t/f 247 dismentling and cartage from site to store charges 7% (other misclenous charges)
  • View Tender
  • Document
  • Bid Support
10 Security Services
image image
Central Government/Public Sector
TRN :48280497 |  17 May, 2025
Tender Value : 4.14 Crore
 Leh - Ladakh
Tender for tender for provision of central mi room at nimu(job no 01/nimu stn/amwp/2023-24); 1 lump sum price worked out by the contractor for building worksas listed in schedule ‘a’ part-i representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 43 2 lump sum price worked out by the contractor for (site clearance, excavation & earth work)as listed in schedule ‘a’ part-ii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 44 3 lump sum price worked out by the contractor for (internal electrification)as listed in schedule ‘a’ part-iii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 50 4 lump sum price worked out by the contractor for (internal water supply)as listed in schedule ‘a’ part-iv representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 52 5 lump sum price worked out by the contractor for (road, path & hardstanding)as listed in schedule ‘a’ part-v representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 54 6 lump sum price worked out by the contractor for (sewage disposal)as listed in schedule ‘a’ part-vi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 55 7 lump sum price worked out by the contractor for (area drainage)as listed in schedule ‘a’ part-vii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 56 8 lump sum price worked out by the contractor for (shed for dg set)as listed in schedule ‘a’ part-viii representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 58 9 lump sum price worked out by the contractor for (hot water supply)as listed in schedule ‘a’ part-ix representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 59 10 lump sum price worked out by the contractor for (external electrification)as listed in schedule ‘a’ part-x representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 65 11 lump sum price worked out by the contractor for (external water suplay)as listed in schedule ‘a’ part-xi representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 66 12 sch a part - xii (misc b/r & e/m items) (refer boq)note: this schedule is not pre-priced by mes and the rate indicated as rs 0.00 under col 5 signifies this fact only 13 internal electrifications&f double door three phase prewired distribution board vertical db vtpn 8 way with acrylic door made out of crca sheets 1.6 mm thick,phosphatised powder coated with copper bus bar 200 amps, 415 v,ip 43/ik09, earth stud, din rail, polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingmccb4 pole 63 amp rating repturing capacity 16 ka.(note:- single phase mcbs are to be measured and paid for seperately) 14 s&f led building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240v, ip 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long med grade gi pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith ms clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm pvc insulated 3 core wire complete all as directed and specified by engr-in-charge.note - cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 s&f new wall mounted fan of approved make and type complete all as specified and as directed. 16 s&f tv co-axial socket 1 module, complete all as specified and as directed. 17 s&f single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole mcb 20 amps 18 internal water supplys&f single piece vitreous china wash down water closet pan pedestal pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type b-0, as in repairs complete all as spd & directed complete all as specified and directed by engr-in charge.. 19 s&f cp grating including jointing to waste pipe fixed in cement concrete type b-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by engr-in charge. 20 s&f hand shower (health faucet ) with 8mm dia and 1 meter long cp flexible tube and wall hookcomplete all as specified make: cera, jaquar , marc & hindware as per sample and directed by engr -in charge 21 s&f soap dish (s/s), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by engr-in charge. 22 road, path & hard standingm&l for wet mix macadam (wmm) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of morth (ministry of road transport & highways) specification of road and bridge works 2013. manufactured in wmm plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 kn static weight and conslidating required gradient and camber. the finished surface tolerance to be as per table 900-1 of morth specification for road and bridge works 2013 complete all as specified and directed by engr-in-charge. 23 m&l for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to bs 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 m&l for rcc septic tank designed to carry sewage and sullage water, excavation in any type of soil, pcc 1:4:8 below foundation, rcc m-30 design mix in walls , base slab , baffle walls and roof slab including beams etc with vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 m&l for soakage wells excavation, in any type of soil, foundation in pcc 1:3:6, walls of honey combed masonry with top ring of m25 concrete including intercepting chamber and screen chamber made of brick masonary in cm, rcc cover slab in m25/ sfrc cover, interconnecting pipes of rcc/dwc complete filled with brick bats of size 3m dia and 3 m depth. 26 s&f pvc junction boxes ip 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 nos mcb sp 2.5 amp & 4 way industrial connector including clamp made out of ms flat 30x5mm connection from junction box to street light fitting with three single core pvc insulated, pvc sheathed wire 2.5 sqmm copper & pvc conduit 20 mm dia complete all as specified and directed by engr-in-charge. 27 excavation in trenches by cutting of road crossing/pcc hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by engr-in-charge. 28 s&fht/lt ms cable route indicator 4 dia fixed with two nos of nut, bolt and washers and provision of pcc 1 : 4 : 8 type d-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by engr-in-charge. 29 supply, installation, testing and commissinoning lt panel board suitable for working on 3 phase ,4 wire ,415 volts, ac ,50hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick crca sheetduly powder coated and shall be cpri approved and as approved by ge. the panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, copper bus bar duly covered with heat shrink sleeves colour coaded duly fixed ondmc/smc insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing mccbs shall have extended bus bar links and mounted on 50x50x5mm sizems angle iron frame duly painted including pcc 1:2:4 type b1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of age (i) nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) mccb 400 amps, fp, 36 ka, 415 volts, 50hz - 01 no (i/c)(b) mccb 200 amps, fp, 25 ka, 415 volts, 50hz - 02 no ( chs)(c) mccb 125 amps, fp, 18 ka, 415 volts, 50hz - 04 nos (apfc, tpn db -02, spare )(d) mcb spn 40 amps, 10 ka, 220 volts, 50hz - 03 nos (garage,street light, spare-1)(e) on load chengeover 630 amps 4 pole -01 no (f)digital voltmeter, with vss - 01set(g) digital ammeter, with cts & ass - 01 set(h) led phase indication lamps ryb - 01 set(j)single phase rotary automatic light controller nature switch with voltage range 120-440v,ac,20 amps,ip-65,50hz-01 nos(k) copper bus bar tpn 600 amps rating - 01 set 31 labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and gi tubing in soft/loose soil complete all as specified. 32 m&lfor cutting existing gi pipes and insertion of new tee branches of suitable size to take branch connection of 50mm dia pp-r.note : suitable size of tee branch is deemed to be included in the quoted rate. 33 construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingpcc in foundation of the mixture (1:4:8) d-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) ms steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed ms work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in pcc with two coats of black bituminuos paint andall other relevant work complete . 34 m&l for providing tracer/anti freezing cable required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (central heating system)electric hot water generator : supply, installation, testing and commissioning ofpackage type electric hot water generator constructed out of ms sheet having top open-able cover for easy access and removal of heaters. the hwg shall be suitable for indoor mounting. the generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22g aluminium cladding sheet. the generator shall have electrical capacity of 50 kw. the heater shall be electrical resistance type, copper tube with chromium plating. the generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. the generator shall be suitable for 3 phase, 415+ 10% volts, 50 hz. ac supply. the generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 notes:- (i) allneccassary accessories required for the proper fucntioning of hot water genearator are included in price.(ii) the prices should include lifting, shifting and positioning of units at site.(iii) hot water genearator installation to done as per manufacturer recommendation with all installation requirements i.e foundation, vibration isolator,insulationetc as recommended by manufacturer for the ambient temperature of site. odu installation is included in odu price which includes the civil struture, mechanical structureetc as recommended bymanufacturer.(iv) the contractor/oem will shall submit the hot water generator capacity/burner capacity conforming to relevant is code(v) oem should submit the installation and maintenance schedule/ manual for the boiler. 37 glycol circulation centrifugal pumps: supply, installation, testing & commissioning of pn16 ratedaxial split coupled vertical inline water pump set with ci casing, bronze impeller, ss shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with suitable hp, tefc squirrel cage induction motor with ie3 type class f insulation, motor shall be rating of ip 55, operating on 415 ±10% volts, 3 phase, 50hz ac supply. the external flush line must be used for the purpose of heat dissipation from the mechanical seal.pumps with performance characteristics as given below:the internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 degree celcius to 120 degree celcius. vendor shall be provide antivibration arrangement for pumps . 38 the scope also shall include following below mentioned:(i) electrical by pass starter for pump setas recommended by oem. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) pressure gauges 150 mm dia -03 nos (iv) mounting frame with antivibration pads (in case pumps are inline, anti vibration system shall be as per manufacturers recommendation) (v) rcc/cement concrete foundation for the pump unit. (in case pumps are inline, foundation shall be as per manufacturers recommendation).pump capacity are as under:capacityand pump headnot less than flow 25 usgpm , head 20 mtr (refernce model no. : armstrong : series 4300 - 40-150 - 2p - 1.5 kw) each including the triple duty valve and end suction guide. 39 expansion tank and pressurisation unit:supply, installation, testing and commissioning of insulated pressurised closed water expansion tank suitable for total volume ofglycol - water solution, circuit along with necessary accessories such as along with necessary accessories such as 2 nos pumps (1working +1standby) with pressure transmitter andinterconnecting pipe & isolating valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with pressure transmitter andinterconnecting pipe & isolating valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. the tank shall be pre-charged. expansion tank shall be with replaceable heavy duty butyl rubber bladder. the tankconnections should be as per oem recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.the tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. the tank must be constructed in accordance with is-standard 2825-1969 (withlates revision)and rated at pn 16 . the complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.the tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelip55 control panel, pressure transmitter, interconnecting piping & wiring. (tank capacity 500 ltrs). hot glycol - water closed vessel pressurized expansion tank as described above shall be duly insulated with 50 mm thick puf/nitrile rubber insulating material or equivalent u valueinsulating material and cladded with aluminium sheet (20g). electrical by pass starter for pump setas recommended by oem. 40 expansion tank of 500 lts capacity 41 pressurization unit: for pump set -03 nos with control panel and accessories. 42 make up tank: supply, installation, testing and commissioning of factory made make up water tank, rectangular/circular shape, of 4 mm thick ms sheet (is 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of ms and vent with flame arrestor. tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above ffl. service platform shall be provided as per recommendations of oem. the tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. extra high level and extra low level alarm shall be provided. tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.make up water tank as describedabove should beduly insulated with 50 mm thick puf/nitrile rubber insulating material and cladded with aluminium sheet (20g). 43 supply, installation, testing and commissioning ofsteel plate radiator( wall mounted) confirming en- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°c, complete with top grill side cover as standard along with inlet ,outlet valve, air purge valve andwith threaded plug, flow regulator as per oem.the below desired capacity should be calculated at altitude of 3600 mts above sea level. capacity calculation sheet to be provided to engineer in charge. the below mentioned capacity is at inlet temp: 75 degree celcius , outlet temp: 65 degree celcius. referemcwe model series. 44 1.5 kw, type: 33- dkek, length is 1000 mm and height is 600 mm of radiator. 45 2.5 kw, type: 33- dkek, length is 1000 mm and height is 600 mm of radiator. 46 3.5 kw,type: 33- dkek, length is 1600 mm and height is 600 mm of radiator. 47 5 kw,type: 33- dkek, length is 1600 mm and height is 900 mm of radiator. 48 5 kw,type: 33- dkek, length is 2000 mm and height is 600 mm of radiator 49 m & l for pre-insulated ms pipe,class c havingminimum thicknes of puf insulation as mentioned below and of density 36 kg/cum and 26 gauge al cladding complete suitable for above ground as per sizes shown.the pipes should be insulated with closed cell puf of density 36±2 kg/cum of below mentioned thickness. the pipe should be workable in the temp. range of-50 degree celciusto120 degreec celcius. note:-the pipes size 150mm & below shall be m.s. ‘c’ class as per is : 1239 50 80 mm with 36 mm puf thicknes and 26 gauge al cladding. 51 50 mm with 36 mm puf thicknes and 26 gauge al cladding. 52 50 mm with 36 mm puf thicknes and 26 gauge al cladding. 53 40 mm with 36 mm puf thicknes and 26 gauge al cladding. 54 20 mm with 36 mm puf thicknes and 26 gauge al cladding. 55 buried under ground/exposed to ambient:80 mm with 50 mm puf thicknes and hdpe cladding, 26 gauge al cladding. 56 cabel tray :-supplying and installing following size of perforated painted with powder coating m.s. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/ground/wall with m.s. suspenders as per is code including bolts & nuts, painting suspenders etc. as required of size 150 mm width x 50 mm depth x 1.6 mm thickness 57 supplying, fixing, testing and commissioning of following diameter valves (pn-16 rating) (complete with flanges integral or welded, fittings, nuts, bolts & gaskets (pn-16 rating), strainers (complete with flanges integral or welded, fittings, nuts, bolts & gaskets (pn-16 rating), gauges etc for condenser water circulation as per specifications. insulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as specified. butterfly valve ( insulated valves) with ci body ss disc nitrile sheet & o ring, complete with fittings, nuts, bolts & gaskets.butterfly valve ( insulated valves) with ci body ss disc nitrile sheet & o ring, complete with fittings, nuts, bolts & gaskets. 58 80 mm dia butterfly valve 59 65 mm dia butterfly valve 60 50 mm dia butterfly valve 61 supplying, fixing, testing and commissioning of y-strainer (insulated valves) of ductile ci body flanged ends with stainless steel strainer forhot water circulation including insulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as specified of size 50 mm dia y strainer. 62 supplying, fixing, testing and commissioning of non - return valve (insulated valves) with duel plate of ci body ss plates vulcanized nbr seal flanged end & pn 16 pressure rating forhot water circulation includinginsulation thickness ofvalves should be equal to the insulation of puf and gi cladding of pipe section as sepcified of size 50 mm dia nrv. 63 supplying, fixing, testing and commissioning of automatic air purge valves forhot water circulation headeras specified of size automtic air purge valve 20 mm dia. 64 supplying, fixing, testing and commissioning of air separator compleate allas specified of size 50 mm dia. 65 supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and ss tubing, socket.range (0-50) / (0-100) as required by engineer in charge. 66 supplying, fixing, testing and commissioning of mercury in glass industrial thermometer in ss-304 casing with 0.5 c least count, range 0-50 c. brass oil filled thermowell of 1/2 size as required by engineer in charge. 67 electrical distribution panel supply, installation, commissioning and testing of factory made, chs plant, indoor type made out of crca sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with ms angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 phase4 wire, 415 volts, 50 hz, ac supply system, floor mounted and grounting the legs of panel in pcc foundation 1:4:8 complete as all directed suitable for and including the following :- 68 incomers(i) bus bar tpn al extensible type main bus bars of minimum of 600 a capacity (as per capacity of corresponding incoming / bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c smc bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50ka .(ii)mccb 400 amps, 415 volt, 36 ka, 4 pole,microprocessor release- 01 no for incoming (extended rotary operating handle, phase spreader links and phase barriers ) make: legrand/schenider/simensoutgoings(i) 3nos- 125a ,25 ka tpnmccb/acbwith microprocessor release (3# hot water generator)(ii) mcb 10 amp,tpn,10ka, c curve - 06, 3 nos for pumps , 2 nos for pumps ,01 nos for glycol transfer pump(iii) led phase indication lamps (01 set) with 2amp back up mcb,breaker on/off indicating light with 2a mcb, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 set (iv) digital ammeter with in built ass,metering c.t.scast resin type, 15va, and accuracy class-1of 800/5a for measuring current in each phase - 01 set.(v) all accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per manufacturers recommendations all as directed by engnr-in-charge.note : contractor will submit the drawing for approval of panel to ge before execution. 69 lt cables : supply & laying/ fixing of following size xlpe insulated and pvc sheathed copper conductor armoured cable/unarmoured as required of 1.1 kv grade complete as require (isi marked) (in ground/in pipe/in duct/on surface/on cable tray) 70 3.5 core x 70 sq.mm. (electric hot water generator) 71 4.0 core x 10 sq.mm. (pump) and (pressurization unit) 72 2 core x 10 sq.mm. (pump) 73 2 core x 6 sq.mm (pressurization unit) 74 earthing complete with copperearth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long gi pipe connected to main controlboard and gi pipe light grade 20mm bore for watering and including funnel, wire mesh, rcc pit cover 50mm thick and pcc chamber pit with pcc 1:2:4 type c2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate no 3 of ssr part-i 2009 complete all as specified & directed by engr-in-charge 75 s&f rubber matting conforming to is-15652-2006 complete as required. of size2m x 1m x 25 mm 76 glycol - water solutionsupplying of ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.note;- (i) the glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. the glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 degree celcius (ii) first charge of glycol is included in the quoted rate. first charge include charge in chs pipe linestorage tank. (glycol 45 % ,water 55 %) 77 for chs 78 supply of gycol for running of plant for 12 months 79 glycol circulating pump: supply, erection, testing and commissioning oftransfer pumps for the capacity of 5 lpm 5 meter head for glycol fluidtransfer with base frame foundation, bolts coupling coupling guard,tefc, (oem design hp for the required flowand head ) andother accessories for proper function of the pump. 80 oxygen gas manhold : supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, nrv and essab make 10x14 regulator complete all as specified and directed by engr in charge . 81 supply , installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by engr in charge . 82 supply , installation , testing and commission automatic control panel with analog display 02 for oxygen complete all as specified and directed by engr in charge. 83 s&f of copper tubing of size 15 mm od, en -13348 grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by engr in charge. 84 s&f of copper tubing of size 12 mm od, en -13348 grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by engr in charge. 85 s&f bs type gas outle with probe for oxygen for medical compleate all as specified and directed by engr in charge 86 s&f 1/2 brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by engr in charge. 87 s&f bpc flow meter (0-15 lpm) including humidfire bottle complete all as specified and directed by engr in charge . 88 s&f 3/8 brass ball valveincluding all fittings for complete all as specified and directed by engr in charge. 89 stand by dg set : supply,install, test and commissioning of silent diesel engine generating set 415 volts, 3 phase, 4 wireengine as per is08528 conforming to cpcb norms iv, and alternator as per is08528 of capacity 400 kva at ntp with control panel having meters, sound proof canopy etc with foundation (as per oem design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- ac generator should be suitable for ambient conditions at nimu leh area. 90 (a) alternator : standard design alternator rated at 400 kva (320kw)net output at power factor 0.8, ac, 3 phase 4 wire, 415 v, 50 cycles/second, 1500 rpm self excited, self regulated, screen protected, drip proof ip 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (b)diesel engine : vertical diesel engine of suitable capacity, water cooled, closed circuit as per bs-649 or is-1002 direct injection type turbo charged, electric starting system having rated speed 1500 rpm. the dg set shall be capable for running with 10% over loading for 01 hour in every 12 hours as perbs-5514/bs-649. engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following specifications.(a) fly wheel with housing (i) common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) cooling system (i) radiator with fan & belts & guard, rubber hoses and thermostat. (ii) cooling water pump centrifugal type . 91 (c) governer : electronic governer (d) electric starting system : electric self starter , 24 volts dc(12 volt, 150 ah battery 2 nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2x12 volt 150 ah capacity. (e) generator monitoring panel : comprising of following :- (i) microprocessor based genset controller for metering, monitoring, governing and protection. (ii) engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) accessories:avm pads built or separately mounted to manufacturer base frames. (g) coupling arrangements: fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) exhaust system : should have equipped with emission control device as per latest govt norms. silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) fuel tank: daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (c)acoustic enclosure : all as per cpcb norms iv and oem of dg sets design.(d)amf panel : supply, install, testing and commissioning of amf panel outdoor type, cubical body,dust and vermin proofmade up of crca sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to ip 45 with front and rear opening with louvers andmounted on floor with pcc pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) microprocessor based panel -01 no(ii) power contactor heavy duty suitable for generator and mains (iii) over load relay for genset (iv) suitable rating isolating switch mccb for both dg & main supply.(v) multi functioning meter to indicate voltage, current, frequency, p f, kw & kwh etc (vi) emergency stop push button.(vii)set of indicaters : - (a)low lube oil pressure (b) dg set over load(viii) push button to start, stop (ix) mode selector switch i.e auto/manual/test/ off.(x) set of instrument fuse (xi)set of aluminium bus bar of 600 amps capacity 3 ph, 4 wire system (xii) automatic battery charging unit with dc voltmeter, ammeter and selector switch for trickle/ boost charging.(xiii) by pass arrangement of main supply when amf circuit fail due to any fault with provision of suitable rating change overs and switches. 93 the following items are deemed to be included in the rate quoted for all dg sets:- (i) dhpp for testing purpose shall be supplied by the contractor without any extra cost to department. (ii)the contractor shall arrange for artificial load (water load/electrical load) for testing for final testing of dg set at site and the cost is deemed to be including in above offer. (iii) testing of sound level should carried out at the site in presence of engineer-in-charge(iv) one set of latest spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) all civil works including foundation for dgset as per manufacturers drawing/ specification, foundation for amf panel shall deemed to be included in the quoted rate.(vi) the rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
  • View Tender
  • Document
  • Bid Support
  • 1
  • Tenders Expired In - 2025
  • Tenders Expired In - 2024
  • Tenders Expired In - 2023
  • Tenders Expired In - 2022
  • Tenders Expired In - 2021
  • Tenders Expired In - 2020
  • Tenders Expired In - 2019
  • Tenders Expired In - 2018
  • Tenders Expired In - 2017
  • Tenders Expired In - 2016
  • Tenders Expired In - 2015
Related Searched Keywords : anti static
  • Tiles Work Tenders ,
  • Interlocking Tile Repair Tenders ,
  • Block Paving Tenders ,
  • Vitrified Tiles Repair Tenders ,
  • Terrazzo Floor Tenders ,
  • Pvc Vinyl Flooring Tenders ,
  • Rubber Interlocking Tiles Repair Tenders ,
  • Interlocking Paver Repair Tenders ,
  • Tile Work Tenders ,
  • Floor Screed Repair Tenders

Get anti static Tender Alert...

146411

Related Searched Keywords : anti static

  • Earth Excavation Tenders From Maharashtra
  • Drainage System Tenders From Delhi
  • Irrigation Tenders From West-Bengal
  • Bore Work Tenders From -Tamil-Nadu
  • Railway Bridge Tenders From Andhra-Pradesh
  • Granite Work Tenders From Gujarat
  • Land Levelling Tenders From Karnataka
  • Stone Cladding Tenders From Uttar-Pradesh
  • Culvert Slab Tenders From Rajasthan
  • Demolishing Work Tenders From Madhya-Pradesh

Read More


Tender Document

427931

State Tenders »

  • Maharashtra Tenders
  • Delhi Tenders
  • West Bengal Tenders
  • Tamil Nadu Tenders
  • Andhra Pradesh Tenders

City Tenders »

  • Hyderabad Tenders
  • Visakhapatnam Tenders
  • Guwahati Tenders
  • Patna Tenders
  • Chandigarh Ut Tenders

Keyword Tenders »

  • Acoustic Panels Tenders
  • Dismantling Tenders
  • Infrastructure Works Tenders
  • Sewer Lines Tenders
  • Sewage Pipeline Tenders

Sector Tenders »

  • Drugs And Pharmaceuticals Tenders
  • Survey Work Tenders
  • Shipping Transport Tenders
  • Scientific Research And Instruments Tenders
  • Security Services Tenders

Ownership Tenders »

  • Central Government And Public Sector Tenders
  • Co Operative Tenders
  • Corporations And Associations And Others Tenders
  • Private Sector Tenders
  • State Government Tenders

Indian Segment

  • State Tenders
  • City Tenders
  • Industry Tenders
  • SubIndustry Tenders
  • Sector Tenders
  • Ownership Tenders
  • Agency Tenders
  • Keyword Tenders
  • Source of Tenders

Browse Tenders

  • RFP-RFQ Tenders
  • Vender Registration Tenders
  • ICB Tenders
  • NCB Tenders
  • Auction Tenders
  • Corrigendum Tenders
  • E Procurement Tenders
  • GeM Tenders (Registration)

Global Segment

  • Middle East Countries Tenders
  • European Countries Tenders
  • African Countries Tenders
  • Asian Countries Tenders
  • Saar Countries Tenders
  • Australia Oceania Countries Tenders
  • South America Countries Tenders
  • North America Countries Tenders

Others

  • Services
  • Sitemap
  • About Us
  • Contact Us
  • Career
  • Tender Consultants

Get in touch with us

  • +91-92760 83333 (In India)
    +91-92743 15555 (South India)

  • sales@thetenders.com / ceo@thetenders.com

W B


Copyright ©2018 - Thetenders.com. Read Policies

Download Mobile App