Notice Inviting Tender (NIT) by the State Government Of Maharashtra for Supply, Installation, Training And Commissioning Of Laboratory Equipments Hardware Specifications-Wavelength Range 190 To 1, 100 Nm,, Spectral Bandwidth 1 Nm 190 To 1, 100 Nm, Wavelength Display 0.1 Nm Increments, Wavelength Scanning Speed 3, 000 To 2 Nm/Min, 29, 000 Nm/Min When Survey Scanning, Lamp Interchange Wavelength Automatic Interchange Linked To Wavelength., The Interchange Wavelength Can Be Set Freely In The Range Of 295 To 364 Nm 0.1 Nm Increments., Stray Light Less Than 0.02% At 220 Nm Nai, Less Than 0.01% At 340 Nm Nano2 Less Than 0.5% At 198 Nm Kcl, Photometric System Double Beam Optics, Photometric Range Absorbance: -4 To 4 Abs, Transmittance: 0% To 400%, Photometric Accuracy ± 0.002 Abs At 0.5 Abs, ± 0.0025 Abs At 1.0 Abs± 0.006 Abs At 2.0 Abs, Measured Using Nist930d/Nist1930 Or Equivalent., Output Device Usb Memory Optional, Data Files Saved In Text Format Or Uvpc Format., Uvpc-Format Files Can Be Read Directly, By Uvprobe And Labsolutionstm Uv-Vis.Pc Compatibility Uvprobe Software Standard Labsolutions Uv-Vis Software Optional, External Control Possible Via Usb., Display 24-Bit Color Touch Screen, Supported Languages Japanese, English, Chinese, Spanish, Mexico, Portuguese Brazil. Software Specificationsphotometric Mode Single-Wavelength Measurement, 1. Photometric Modes: T% Or Abs Fully Automatic Validation Automatic Validation Inspections From Measurement To Evaluation And Printout. Setting Inspection Parameters And Pass/Fail Criteria Authority To Make Changes Can Be Protected By Password Access.Detailed Printout Of Results. Bulk Printout Of Results. Equipped With Method In Accordance With Pharmacopeia Jp, Usp, Ep. Shared Functions :Automatic Setting Of Measurement Mode After Instrument Initialization.It’S Possible To Specify Standby And Parameter Files In The Parameter Setting Window For Each Measurement Mode. Selection Of Displayed Number Of Decimal Places Absorbance: 3 Or 4 Decimal Places Transmittance: 1 Or 2 Decimal Places 3. Number Of Files That Can Be Saved Built-In Memory Measurement Parameters: 100 Files Max. Tabular Data: 15 Files Max. Curve Data: 16 Files Max. Validation Condition: 10 Files Max. Validation Result: 3 Files Max. 4. Setting Of Integration Time For Fixed-Wavelength Measurement 5. Pc Control Spectrophotometer Can Be Controlled By An External Pc. This Function Is Also Used When Performing Operation With The Stanard Uvprobe Software And The Optional Labsolutions Uv-Vis Software Provided. *A Usb Cable Is Required. Optical -Wavelength Range 200–1, 000 Nm, Photometric Methods Single And Dual Wavelength, Monochromator Step Size 1 Nm Bandwidth 5 Nm, Wavelength Accuracy, Minimum ±2.0 Nm, Wavelength Repeatability ±0.2 Nm, Imaging Resolution 0.5, 0.75, 1.0 Mm, Performance-Indication Range 0–4.0 Od, Resolution 0.001 Od, Linearity =2.0%, 0–3.0 Od At 405 Nm, Accuracy ±1.0% Or 0.015, 0–3.0 Od, Reproducibility 96-Well Plate; =1.0% Or 0.005, 0–3.0 Od At 405 Nm, Stability And Drift =0.010 At Od 1 At 490 Nm Read Time 8 Sec/96-Well/Single Wavelength; 15 Sec/384-Well/Single Wavelength; 35 Sec/1, 536-Well/Single Wavelength Physical, Compatible Plates 6- To 1, 536-Well And Custom Microplates, Maximum Plate Height 21 Mm Led Indicator • Energy Efficient & Eco-Friendly • Machine Auto Shuts After The Water Is Over In The Chamber • Comes With Collection Chamber For Easy Storage & Portability • The Distillation Unit Is Essential Laboratory Aid With Easy To Operate & Maintain Process • Exterior Of Machine Is Made Up Of Engineering Plastic & Interior Chamber Is Made Up Of Stainless Steel 304 • Water Tank Capacity 4 Liter • Water Distillation Capacity- 1.5 Liter/Hour • No Wastage Of Water Because Of Continuous Vaporization & Condensation During Distillation Cycle • In-Built Fan Cooling System For Condensation • No Need Of Tap Water Connection • Comes With Detergent For Washing Of Residue Temperature Range & Accuracy 5°C To 60°C, ± 0.5°C 5°C Above Ambient To 60°C, ± 0.5°C Internal Volume Liters 215, Platform Size 580Mm X 600Mm, Maximum Shaking Capacity Volume X No. Of Flasks* 100Ml X 49, 150Ml X 49, 250Ml X 33, 500Ml X 24, 1000Ml X 15, 2000 Ml X 9, Shaking Speed Range Rpm 20 To 250 Shaking Amplitude 25 Mm, Internal Dimensions W X D X H Mm 660 X 765 X 650, External Dimensions W X D X H Mm 800 X 1150 X 1300, Temperature Control Microprocessor With Pt-100 Sensor, Display 4? Lcd Screen, Large Size Display For Ease Of Reading, Power Failure Alarm Audio Visual Alarm, Door Open Alarm Audio Alarm In Case Door Open For Over One Minute, Temperature Variation Alarm Set Temperature ± 2°C, Audio Visual Alarm Illumination 8 Watts Fluorescent Tube, Internal Body Material Stainless Steel – 304 Grade Standard Models, Stainless Steel – 316 Grade Gmp Models, External Body Material Powder Coated Crca Steel Standard Models, Stainless Steel – 304 Grade Gmp Models, Insulation Cfc Free Polyurethane Foam 70 Mm Minimum For Body & 80 Mm For Door, Noise Level Less Than 65 Db A, Recommended Voltage Stabilizer Vs-02 X, Supply: 220-240 Volts, 50 Hz Single Phase. Max. Rotor Capacity: 24 × 1.5/2.0 Ml Vessels, Max. Speed: 21, 130 × G 15, 000 Rpm, Optibowl® Design For Quiet Operation, Even Without A Rotor Lid Soft-Touch One-Finger Lid Closure For Ergonomic Operation, Temperature Range From -10 °C To +40 °C, Eco Power Shut-Off Engages After 8 Hours Of Non-Use To Reduce Energy Consumption 40 % Over Night And Extend Compressor Life Can Be Deactivated, Fasttemp Function For Quick Pre-Cooling Of The Centrifuge, E.G. From ~ 21 °C To 4 °C In Only 8 Minutes, Ensured Temperature Of 4 °C At Maximum Rotational Speed, Built-In Condensation Drain To Eliminate Water Accumulation In The Rotor Chamber The Patented Compressor Technology Reduces Vibrations And Protects Your Samples, Special Features For Centrifuge 5424 R, Temperature Range From -10 °C To +40 °C Guaranteed Temperature Of 4 °C At Maximum Rotational Speed, Fasttemp Function For Quick Pre-Cooling Of The Centrifuge, E.G. From ~ 21 °C To 4 °C In Only 8 Minutes Eco Power Shut-Off Engages After 8 Hours Of Non-Use To Reduce Energy Consumption 40 % Over Night And Extend Compressor Life Can Be Deactivated The Patented Compressor Technology Reduces Vibrations And Protects Your Samples, Built-In Condensation Drain To Eliminate Water Accumulation In The Rotor Chamber Observation Method Brightfield ?, Darkfield ?, Phase Contrast ?, Fluorescence Blue/Green Excitations ?Blue Excitation Only, Simple Polarized Light ?, Illuminator Transmitted Köhler Illuminator Led Lamp ?, Fluorescence Illuminator Led Lamp?, Focus Focusing Mechanism Stage Focus ?, Coarse Handle Stroke15 Mm, Features-Coarse Adjustment Limit Stopper Torque Adjustment For Coarse Adjustment Knob, Revolving Nosepiece Manual Standard 5 Positions ?, Stage Manual Manual Stages With Right-Hand Control Built-In, X: 76 Mm, Y: 52 Mm, Condenser Manual Abbe Conenser Na 1.25 2X–100X, Observation Tubes Standard Fn18 Tilting Binocular ?Standard Fn20 Binocular ?, Trinocular ?, Tube Inclination Angle, Binocular, Trinocular 30°, Tilting Binocular 30°–60°, Trinocular Tube Light Path Selection Camera : Observation 50 % : 50 %, Interpupillary Distance Adjustment, 48–75 Mm, Dimensions W × D × H 211 Mm × 376 Mm × 393 Mm 8.3 In. × 14.8 In. × 15.5 In. Standard Configuration, Weight Approx. 7.3 Kg 16.1 Lb, The Cx43 Microscope System Comes Standard With The Stage And Condenser Included. Dimensions, Mm: 247 X 132 X 48.5D X W X H, Viewing Surface, Mm: 150 X 80 D X W, Wavelength, Nm: 365, Uv Tubes: T5 6 W Uva Power: 12 V, 1.5 A, Weight, Kg: 1.4, Compatible Gel Type: Mini Gels, Compatible Gel Size, Mm: 50 X 60, 105 X 60, 125 X 60 Temperature: Operation 0~40°C, Storage –10~70°C, Humidity: Operation 20~80%, Storage 10~90% Transportation Conditions: Temperature –10~70°C, Humidity 10~90°C, Altitude Conditions: Up To 2, 000 M Voltage 230 Volts A.C, Tubes 3, Efficiency 90%, Wave Length 365 Mm Unit: Tpd-Barc-16Ch, Input Requirement : 230 V, 50 Hz Ac, Weight : Light Weight <2 Kg, Portable, Test Chamber 1 Material : Ss-304, Housing Diameter : 28 Mm, Housing Length : 50 Mm, Sensor Types : Array, Test Chamber 2, Material : Ss-304 Housing Diameter : 81 Mm, Housing Length : 48 Mm, Sensor Types : Individual, Technical Parameters, Resistance Range : M? To O Or G? To K?, Operating Temperature Range : Rt To 300 ± 2°C, Control Software : Labview, Acquisition Type : Simultaneous Data Acquisition Mode And Speed : Adjustable, Maximum 4 Points/Sec, Minimum 1 Point/Sec, Additional Requirement Personal Computer Or Laptop, Labview Licensed Software, Applications Basic Specifications Accuracy Guaranteed For 1 Year, Post-Adjustment Accuracy Guaranteed For 1 Year Measurement Modes Lcr Measurement With Single Condition, Continuous Testing Continuous Measurement Under Saved Conditions, Measurement Parameters Z, Y, T, X, G, B, Q, Rdc Dc Resistance, Rs Esr, Rp, Ls, Lp, Cs, Cp, D Tand, S, ?measurement Range 100 M? To 100 M?, 10 Ranges All Parameters Are Determined According To Z Display Range Z: 0.00 M To 9.99999 G?, Y: 0.000 N To 9.99999 Gs, T: ± 0.000° To 180.000°, Q: ± 0.00 To 9999.99, Rdc: ± 0.00 M To 9.99999 G?, D: ± 0.00000 To 9.99999, ?%: ± 0.000 % To 999.999 %, Or Other Basic Accuracy Z ±0.05% Rdg. T: ±0.03° Representative Value, Measurable Range: 1 M? To 200 M?, Measurement Frequency 4 Hz To 8 Mhz 5 Digits Setting Resolution, Minimum Resolution 10 Mhz, Measurement Signal Level Normal Mode: V Mode/Cv Mode 4 Hz To 1.0000 Mhz: 10 Mv To 5 Vrms Maximum 50 Marms, 1.0001 Mhz To 8 Mhz: 10 Mv To 1 Vrms Maximum 10Marmslow Impedance High Accuracy Mode: V Mode/Cv Mode, 4 Hz To 1.0000 Mhz: 10 Mv To 1 Vrms Maximum 100 Marmsnormal Mode: Cc Mode, 4 Hz To 1.0000 Mhz: 10 ?a To 50 Marms Maximum 5 Vrms, 1.0001 Mhz To 8 Mhz: 10 ?a To 10 Marms Maximum 1 Vrms, Low Impedance High Accuracy Mode: Cc Mode, 4 Hz To 1.0000 Mhz: 10 ?a To 100 Marms Maximum 1 Vrms, Dc Resistance Measurement, Measurement Signal Level: Fixed At 1 V, Dc Bias Measurement Generating Range: Dc Voltage 0 V To 2.50 V 10 Mv Resolution, In Low Z High Accuracy Mode: 0 V To 1 V 10 Mv Resolution, Output Impedance Normal Mode: 100 O, Low Impedance High Accuracy Mode: 10 O, Display 5.7-Inch Color Tft With Touch Panel, Functions Comparator, Bin Measurement 10 Categories For 2 Measurement Parameters, Trigger Function, Open/Short Compensation, Contact Check, Panel Loading/Saving, Memory Function, Interfaces Ext. I/O Handler, Usb, Usb Flash Drive, Lan, Gp-Ib, Rs-232C, Bcd Power Supply 100 To 240 V Ac, 50/60 Hz, 50 Va Max., Dimensions And Mass 330 Mm 12.99 In W × 119 Mm 4.69 In H × 230 Mm 9.06 In D, 4.2 Kg 148.1 Oz, Accessories Power Cord ×1, Instruction Manual ×1, Lcr Application Disc Communications User Manual ×1 Voltage- 230 Volts A. C, Brand- Labline Max Temperature- 1000-1100, 1200-1500, 900-1000, 1100-1200, Working Temperature- 930 C/1130 C, Body Material- Mild Steel Maximum Temperatures 1000 C/1200 C Measuring Range: 0 ... 220 G, - Resolution: 0.1 Mg, - Accuracy: ± 0.5 Mg, - 5 Touchscreen Lcd Display, - Windshield - Rs232 Data Interface, - Calibration: Internal Model-Ps125, Ultrasonic Power-125 Watts, Ultrasonic Frequency-20 Khz, Probe-3 Mm, Sample Volume-1-100Ml Display-Led/Lcd/Touch Screen, Programmable-Led/Lcd/Touch Screen - 10 Nos. Of Program Can Be Set And Stored Controller-System With Microprocessor Based Programmable Controller, On/Off Pulse-Controls On And Off Cycles Independently From 1 To 99 Second, Programmable Timer-Process Continuously 1 To 999 Minutes 16 Hrs. Operating Voltage-Ac 230V & 50/60 Hz; Single Phase., Overload Protection-Power Protection, High Temp. Protection, High Voltage Protection, Tuning-Auto Tune / Manual Tuning, Probe Material-Titanium Alloy Ti-6Al-4V, Variable Amplitude-Variable Amplitude & Power Control 0-25-50-75-100 %., Sealed Converter-Piezoelectric Lead Zirconate Titanate Crystals Pzt Energy Converter., Temp. Indicator-Indicates Sample Temperature 0 To 150° C, Temp. Controller-Indicates Temp.& Automatically M/C Off When It Crosses Desired Value, Standard Accessories-Ultrasonic Generator, Ultrasonic Cable, Pt 100 Sensor, Sealed Convertor, Probe 1 Standard Probe, Wrench Set., Warranty-One Year, Optional Accessories-Sound Enclosure, Support Stand, Laboratory Jack, Foot Switch Max. Filling Volume 6 Ml For 10 Ml Vial-20 Ml For 30 Ml Vial, 2 Ml For 4 Ml Vial, Max. Operation Pressure 30 Bar 435 Psi, Max. Ir Temperature 300 °C, Max. Fiber-Optic, Max. Power 850 W Temperature 300 °C, Vial Material Borosilicate Glass, Silicon Carbide, Cap Material Peek, Camera Integrated, Seal Material Teflon-Coated Silicone, Typical Applications Method Development Optimization Basic Academic And Industrial Research Measuring Range Of Melting Point : Ambient To 300°C* Resolution : 0.1°C, * Rate Of Heating°C/Min : 0.2, 0.5, 1, 1.5, 2 3, 4, 5, * Accuracy : +0.5°C Upto200°C, +0.8°C From 200°C To 300°C, * Heating Time 50 To 300°C : 3 Mins, * Cooling Time 300 To 50°C : 5 Mins, * Capillary Sample Tube Size : Od 1.4Mm, Id 1Mm* Power Supply : 220 V +/-10%, 50Hz, 100 Watt, * Dimensions : 400 X 280 X 210 Mm, * Weight : 12.5 Kg Dimension 1200 X 850 X 2350 Mm, Power Source Electric, Voltage 220 V, Material Polypropylene A. Orificemeter Suitable For 1” Size Pipe Line & D/D Ratio Is 0.6 With 2 G.M. Valves., B. M.S. Reservoir Of Size 0.4 M W X 0.35 M H X 0.7 M L With, Drain Valve Of ½ ” Size & A Bend. C. M.S. Collecting As Well As Measuring Tank Of Size 0.5 M Length X 0.35 M Width X 0.35 M Height & Drain Valve Of 1” Size. A Gauge Glass & Scale Fitting Are Fitted On Measuring Tank For Discharge Measurement., D. 0.4 M Height Double Column Differential Manometer. Without Mercury, E. ½ Hp High Head Monoblock Pump For Water Circulation. F. Strong Iron Stand To Support The Unit., G. Entire Unit Is Powder Coated With Good Colour Combination., H. Instruction Manual 1 Copy. A. Venturimeter Suitable For 1” Size Pipe Line, B. M.S. Reservoir Of Size 0.4 M W X 0.35 M H X 0.7 M L With, Drain Valve Of ½ ” Size & A Bend. C. M.S. Collecting As Well As Measuring Tank Of Size 0.5 M Length X 0.35 M Width X 0.35 M Height & Drain Valve Of 1” Size. A Gauge Glass & Scale Fitting Are Fitted On Measuring Tank For Discharge Measurement., D. 0.4 M Height Double Column Differential Manometer. Without Mercury, E. ½ Hp High Head Monoblock Pump For Water Circulation. F. Strong Iron Stand To Support The Unit., G. Entire Unit Is Powder Coated With Good Colour Combination., H. Instruction Manual 1 Copy. in Latur - Maharashtra has been published.
The last date of this tender is 08/02/2021, work value is  4100000 INR, EMD is  160000 INR and tender document fees is  8000 INR
For more details call us on +91 92760 83333 for bidding support this tender, GeM, vendor registration (if any) and tender BOQ documents.

Tender Document

Related Information

Location

Latur - Maharashtra ( IN )

Ownership

State Government Of Maharashtra

Sector

Education And Research Institutes

Important Dates

Published on

27 Jan, 2021

Submission Date

06 Feb, 2021

Opening Date

08 Feb, 2021

Key Values

Work Value

41.00 Lacs

EMD

1.60 Lacs

Document Fee

8.0 Thousand
Tender Document Liaison Service Connect with us