Notice Inviting Tender (NIT) by the State Government Of Jharkhand for
Purchase Of Machine Equipment 5 Part Differential Haematology Analyzer
The Analyser Should Have Enumeration & 5 Part Differentiation Of Wbc By Flowcytometry With Chemical Dye &Laser Scatter; Rbc & Plt Counting By Impedance Method With Histograms &Scattergrams; Haemoglobin Measurement By Colorimetry Using Led
The Analyzer Should Have A Through Put Of At Least 60 Samples/Hour The Analyzer Should Have Independent Channel And Optical Measurement For Basophil & Should Have Relevant Scattergram The Analyzer Should Have Flagging Options For Abnormal Samples
The Analyzer Should Have The Facility For Optional Barcode Scanner The Analyzer Should Have The Capacity To Store 40000 Sample Results With Histograms &Scattergrams The Analyzer Should Measure At Least 25 Parameters- Wbc, Lym%, Mon%, Neu%,
Eos%, Bas%, Lym#, Mon#, Neu#, Eos#, Bas#, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Rdw-Cv, Rdw-Sd, Plt, Mpv, Pdw, Pct, P-Lcr, P-Lcc The Analyzer Should Have A Closed Structure Designed To Shield Appropriate Parts
From Dust, Electromagnetic Induction The Analyzer Should Have The Following Sample Volume For Different Modes;
Predilute Mode: 20Ul, Whole Blood Mode: 15Ul, Capillary Whole Blood Mode: 15Ul
The Analyzer Should Have High Linearity &Deliver Results With High Precision;
Linearity ;Wbc: 0-500X109, Rbc: 0-8X1012, Hgb: 0-25G/Dl, Plt: 0-5000X109
Precision:Wbc:= 2 % 4-15 X 10^9/L.Rbc:= 1.5 % 3.5-6.0 X 10^12/L, Hgb:= 1.5 % 11.0- 18.0Mg/Dl, Plt: = 4 % 100-500X10^9/L The Analyzer Should Have The Following Power Requirement; 100V-240V Ac,
50Hz/60Hz The Analyzer Should Have The Ability To Adapt External Laser Printer/Inkjet Printer
& Have Built In Various Print Formats & User Defined Formats The Analyzer Should Have The Ability To Monitor Each Cell’S Status And Volume The Analyzer Should Have The Following Operation Environment
Operating Environment: Temperature – 10Oc To 30Oc, Humidity – 20% To 85%
Air Pressure – 70Kpa To 106Kpa The Analyzer Should Have At Least Uni-Directional Lis Interfacing Capabilities
The Analyzer Should Have The Capacity To Run Qc In Separate Qc Files With Qc Data
Import Capability The Analyzer Should Possess Touch Screen High Resolution Operation
The Analyzer Should Support Hl7 Protocols Lan
Coagulometer
It Should Have Key Features - 2 Channel Coagulometer With Independent Optics. 3-Level Qc L L Simultaneous Testing Of Two Different Parameters. Levy Jennings Plot. Ll 50 Programmable Assay Locations. Data Transfer-Rs232.Ll Programmable Sample Id 10 Numeric Characters.
It Should Have Principle Opto-Mechanical Measuring System Assay Modes Pt / Aptt / Fib / Tt / Factors / Ps / Pc / Other Clot Based Assays Display Large Lcd Backlight Graphical Calibration 2 To 7 P
For Pathology Deptt