Notice Inviting Tender (NIT) by the State Government Of Maharashtra for Supplying Spares H.T. Panel 3.3 Kv Vcb - 11 Nos. Material For Safety Alignment Of All Shutters Supply Of 3.3 Kv Ct Supply Of3.3 Kv Pt Spring Charging Motor Closing And Tripping Coil All Indicator Lamps Of Panel Over Current Relay Earth Fault Relay Trip Relay And Trip Circuit Under Voltage Relay Ammeter Voltmeter Ammeter Selector Switch Voltmeter Selector Switch Push Button Mcb Dp 10 A Ac/Dc On /Off Mcb 63 A Tpn Mcb 32 A Tpn Mcb 16 A Tpn Space Heater Thermostat Toggle Switch Socket 4 Pin Control Fuse Links Digital Multifunction Meter Annunciator 04 Window 110 V Dc Annunciator 16 Window 110 V Dc Hooter 110 V Dc Hrc Fuse Links Of Various Capacity Up To 16 A Temperature Scanner Misc. Spares Of All Vcb Panels C & R Panel Safety Alignment Of Shutter Over Current Relay Earth Fault Relay Ammeter Selector Switch Voltmeter Selector Switch Breaker Control Switch T &C Switch Local Remote Control Switch Push Button Mcb Dp 10 A Ac/Dc Mcb 63 A Tpn Mcb 32 A Tpn Mcb 16 A Tpn Toggle Switch Digital Multifunction Meter Annunciator 04 Window 110 V Dc Annunciator 16 Window 110 V Dc Hooter 110 V Dc Triple Pole S/W, 32 Amp With Neutral Link Hrc Fuse Links Of Various Capacity Up To 16 A Lt Panel Safety Alignment Of Shutter Mccb Moulded Case Circuit Breaker 250 A Mccb Moulded Case Circuit Breaker 100 A Triple Pole S/W, 32 Amp With Neutral Link Mcb 63 A Tpn Mcb 32 A Tpn Mcb 16 A Tpn Hrc Fuse Links Of Various Capacity Up To 16 A Ammeter Voltmeter Ammeter Selector Switch Voltmeter Selector Switch Local Remote Control Switch Battery Charger All Door Meters I.E. Ammeter& Voltmeter, Indication Lamps Etc. All Door Meters I.E. Ammeter& Voltmeter, Indication Lamps Etc. Panel Internal Wiring Batteries 2V-300Ah All Batteries, Acid Level. All Batteries Connections . Transformer 33 Kv/3.3Kv - 2 Nos Oil Filtration By Filtration M/C Only Including Bdv, Ppm Tests Hv & Lv Connections & Earthing, All Hv & Lv Side Bushings Horn Gap Fuse, Lightening Arrestor Fuse Barrel, Fuse Link For 33 Kv Line. 33 Kv Isolator All Resting Bolts & Insulators All Resting Bolts, Insulators & Operating Mechanism 33 Kv Vcb Space Heater, Panel Door Indicators As Well As Push Button Etc. Earthing In Switchyard Replacing Existing Earth Pit Material By New Conductive Chemical To Improve Earth Value To Satisfy Electrical Inspector Spreading Clear Metal. Illumination System In Yard Spares Required Gaskets, Hardware, Nut Bolts Etc Eot Crane Required Spares Of All Motors Motor 3.3 Kv, 375Kw - 6 Nos De & Nde Bearings Ht Grease & Ht Warnish Motor Cover Found Jamming Rotor Balancing Workshop Charges Earth Terminal & Cable Connections Lugs Spares As Bearings Per No 12Uph4 Split Casing Pump, Kirloskar Make Gland, Sleeves & Bearings Workshop Work Of Pump Balancing Of Impeller Workshop Charges Consumables For O/H Of Motor & Pump Cotton Waste. Kerosens / Dw 40 /Rustolene, Ht Grease Etc Hardware Miscellaneous As Required Capacitor Banks H.T. 120 Kvar Unit Capacitor Meter High Voltage Hrc Fuse 3.3 Kv/50 Amp For Capacitor Unit H.T. Cable Aluminium Tupe 3 Core – 95 Sq Mm 11 Kv Grade. Indoor & Outdoor Termination Kit For Ht Cables Of Size 95-150 Sq Mm Indoor & Outdoor Termination Kit For Ht Cables Of Size 185-600 Sq Mm H.T. Panel 3.3 Kv Vcb - 11 Nos. Safety Alignment Of All Shutters Checking Tiggtness Of All Cable Connections Lugs Tightness Checking Per 1 No Lug Bus Bar Tightness And Joint Caps Epoxy Insulators Tightness & Insulation Test Ct Connection Tightness Checking And Test If Found Faulty Needs To Replace Pt Connection Tightness Checking And Test If Found Faulty Needs To Replace Spring Charging Motor Testing Closing And Tripping Coil Testing Checking Of Breaker Internal Wiring Tighting All Indicator Lamps And Lamps Of Panel Checking Over Current Relay Testing Earth Fault Relay Testing Optional Trip Relay And Trip Circuit Testing Under Voltage Relay Testing Ammeter Test Voltmeter Test Ammeter Selector Switch Checking Voltmeter Selector Switch Checking Breaker Control Switch T &C Switch Local Remote Control Switch Test & Check Push Button Checking Mcb Dp 10 A Ac/Dc On /Off Checking Mcb 63 A Tpn Connections Tightness Mcb 32 A Tpn Connections Tightness Mcb 16 A Tpn Connections Tightness Space Heater Checking Thermostat Checking Toggle Switch Checking Socket 4 Pin Control Fuse Links Connections Tightness Hooter 110 V Dc Connections Tightness Hrc Fuse Links Of Various Capacity Up To 16 A Wiring Repair & Dressing Connections Tightness Complete Pm Of 1 No Vcb Panel Inspection Charges For Spares Of All Vcb Panels C & R Panel Safety Alignment Of Shutter Checking The Tightness Of All Cable Connections And Gland Tightness Over Current Relay Testing Earth Fault Relay Testing Trip Relay And Trip Circuit Testing Under Voltage Relay Testing Ammeter Test Voltmeter Test Optional Ammeter Selector Switch Checking Voltmeter Selector Switch Checking Breaker Control Switch T &C Switch Checking Local Remote Control Switch Test & Check Push Button Checking Mcb Dp 10 A Ac/Dc Connections Tightness Checking Mcb 63 A Tpn Connections Tightness Mcb 32 A Tpn Connections Tightness Mcb 16 A Tpn Connections Tightness Space Heater Checking Thermostat Checking Toggle Switch Checking Hooter 110 V Dc Connections Tightness Triple Pole S/W, 32 Amp With Neutral Link Connections Tightness Hrc Fuse Links Of Various Capacity Up To 16 A Wiring Repair & Dressing Connections Tightness Inspection Charges For Spares Of All C & R Panel Lt Panel Safety Alignment Of Shutter Checking The Tightness Of All Cable Connections And Gland Tightness Mccb Moulded Case Circuit Breaker 250 A Connections Tightness Mccb Moulded Case Circuit Breaker 100 A Connections Tightness Triple Pole S/W, 32 Amp With Neutral Link Connections Tightness Mcb 63 A Tpn Connections Tightness Mcb 32 A Tpn Connections Tightness Mcb 16 A Tpn Connections Tightness Hrc Fuse Links Of Various Capacity Up To 16 A Ammeter Test Voltmeter Test Ammeter Selector Switch Checking Voltmeter Selector Switch Checking Local Remote Control Switch Test & Check Mcb 63 A Tpn Connections Tightness Mcb 32 A Tpn Connections Tightness Mcb 16 A Tpn Connections Tightness Wiring Repair & Dressing Connections Tightness Battery Charger Physically Checking All Door Meters I.E. Ammeter& Voltmeter, Indication Lamps Etc. Physically Checking Of Panel Internal Connections Tightness Etc. Batteries 2V-300Ah Physically Checking All Batteries Conditions, Acid Level. Checking Physically All Batteries Connections Tightness. All Batteries Corrosion Removal. Transformer 33 Kv/3.3Kv - 2 Nos Checking Humming Sound Before Shutdown Physical Inspection Of Oil Level Physical Inspection And Attended Of Bucolz Relay Condition Physical Inspection Of Leakages If Any From Gasket Or Any Other Spot Physical Inspection Of Hv And Lv Connections And Attended Physical Inspection Of Hv And Lv Bushing Condition And Attended Physical Inspection Of Wti And Oti Meters Condition And Attended Physical Inspection Of Pts And Their Sincere Condition And Connections And Attended Taking Oil From Top And Bottom Drain Plug For Bdv Testing Checking Bdv Test For Physical, Chemical & Electrical Parameters Of Oil From Authorized Lab Oil Filtration By Filtration M/C Only Including Bdv, Ppm, Test Thoroughly Cleaning Of Complete Transformer Checking Hv & Lv Connections & Earthing Tightness Checking Tightness Of All Hv & Lv Side Bushings, Cleaning Thoroughly Complete O/H Of One Transformer Included All Above Items Auxillairy Transformer 33 Kv/415 V Physically Checking With All Respect I.E. Leakages & Tightness Of All Connections Etc Post Insulators In Switchyard Checking All Post Insulators, If Doubt Full Then Ir Value Should Be Taken. Checking Of Tightness Of Conductors On Post Insulators Horn Gap Fuse, Lightening Arrestor Thoroughly Cleaning Of Insulators Physical Checking Of Tightness Of Resting Bolts & Insulators Checking Of Earthing Connection For Both. Air Brake Switch Suitable For 33 Kv Line. Fuse Barrel, Fuse Link For 33 Kv Line. 33 Kv Isolator Physical Checking Of Tightness Of Resting Bolts & Insulators Physical Checking Of Tightness Of Resting Bolts, Insulators & Operating Mechanism Physically Checking For Operational Alignments. 33 Kv Vcb Checking Of All Hardware’S & Foundation Bolts Tightness Etc. Checking Of All Inter Panel Connection Tightness Etc. Checking Of Space Heater, Panel Door Indicators As Well As Push Button Etc. Earthing In Switchyard Checking Earth Value By Dismantling Of All Earthing Connections Replacing Existing Earth Pit Material By New Conductive Chemical To Improve Earth Value To Satisfy Electrical Inspector Cleaning Of Complete Yard Taking Out Grasses & Spreading Clear Metal. Checking Of Illumination System In Yard Spares Required Gaskets, Hardware, Nut Bolts Etc Eot Crane Checking All Operations Of Crane Checking All Forward Reverse Operations Of All Motors With Contactors &Braking Conditions Overhauling Of All Motors Cleaning Of Panel Bd & Rail Etc Complete Motor 3.3 Kv, 375Kw - 6 Nos Complete O/H Of Motor Dismantling Of Coupling Dismantling Of Both Covers Of Motor Dismantling Of De & Nde Bearings Ht Warnish To Stator & Rotor Workshop Work If Motor Found Jamming Rotor Balancing If Required Labour Charges Assembly Of Complete Motor Checking Earth Terminal & Cable Connections No Load Trial Of Motor 12Uph4 Split Casing Pump, Kirloskar Make Dismantling Of Pump & Inspection For Run Out Parts Removal Of Impeller, Gland, Sleeves & Bearings Replace If Bearing, Sleeve, Gland Etc If Found Damaged Workshop Work If Pump Found Jamming Through Cleaning All Parts, Upper, Lower Casings Etc Balancing Of Impeller Labour Charges Assembly Of Complete Pump Coupling Of Pump & Motortrial After Complete Assembly Of Overhauled Pump. Hardware Miscellaneous As Required Capacitor Banks H.T. 120 Kvar Unit Capacitor Meter Physical Checking Of Tightness Of Connections, Resting Bolts, Insulators &Operating. High Voltage Hrc Fuse 3.3 Kv/50 Amp For Capacitor Unit L.T. Capacitor Bank H.T. Cable Aluminium Tupe 3 Core – 95 Sq Mm 11 Kv Grade. Indoor & Outdoor Termination Kit For Ht Cables Of Size 95-150 Sq Mm Indoor & Outdoor Termination Kit For Ht Cables Of Size 185-600 Sq Mm And Rectification Of Electrical And Mechanical Equipment In Pump House And Switch Yard Of Raw Water Pump House Near Waghur Dam Annual Maintenance in Jalgaon - Maharashtra has been published.
The last date of this tender is 23/10/2020, work value is  2500000 INR, EMD is  25000 INR and tender document fees is  1000 INR
For more details call us on +91 92760 83333 for bidding support this tender, GeM, vendor registration (if any) and tender BOQ documents.

Tender Document

Related Information

Location

Jalgaon - Maharashtra ( IN )

Ownership

State Government Of Maharashtra

Sector

Construction

Important Dates

Published on

09 Oct, 2020

Submission Date

22 Oct, 2020

Opening Date

23 Oct, 2020

Key Values

Work Value

25.00 Lacs

EMD

25.0 Thousand

Document Fee

1.0 Thousand
Tender Document Liaison Service Connect with us