Notice Inviting Tender (NIT) by the State Government Of Rajasthan for Supply Of Angiography Items - Femoral Introducer Sheath With Puncture Needle For Adults Size 4 Fr. To 9Fr. Standard Length • Sizes 4 French/ 5 French/ 6 French/ 7 French/ 8 French/ 9 French. • 10-11 Cm Long • Pack Must Include 18G, 6-7.5 Cm Long Puncture Needle And 0.035 Inch Guide Wire • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • Integral Side Port With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back- Out During Insertion • With Smooth And Resistance Free Insertion Radial Glide Sheath Introducer Sheath With Outer Diameter One Fr Size Under. 6 Fr Sheath With Outer Diameter Of 5 Fr • Size 5 French/ 6 French/ 7 French • Sheath Should Be Between 10-20 Cm Long • 0.021 And 0.025 Inch Guide Wire Compatible • Hydrophilic Coating • 20-22 G Needle Length 2’ Inch • Guide Wire Should Be Available In 3 Forms A. Plastic Short Angle B Flex Straight C Nitinol Floppy • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • Integral Side Port With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion Long Introducer Sheath 20-50 Cm Long Size 4Fr. -11Fr. • Size 4 French/ 5 French/ 6 French/ 7 French/ 8 French/ 9 French/ 10 French/ 11 French • Sheath Should Be Between 20-50 Cm Long • 0.035 Or 0.038 Inch Guide Wire And Compatibility • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • Integral Side Port With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion Trans Radial Introducer Sheaths 4F-6F- • Size 4 French/ 5 French/ 6 French • 07-10 Cm Long • Guide Wire Should Be Available In 3 Forms A. Plastic Short Angle B Flex Straight C Nitinol Floppy • Pack Must Include Surflash Like Puncture Needle With Plastic Iv Catheter, 20G – 22G, Length 2 Inches • 0.025 Inch Hydrophilic Miniplastic Guide Wire Length 45 Cm And Compatibility • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • Integral Side Port With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator Hub-Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion Long Braided Introducer Sheath- • Size 6 French/ 7 French/ 8 French/ 9 French And Above • Should Be 30-90 Cm And Above • 0.021 Or 0.025 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • Integral Side Port With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion Ptfe Coated Diagnostic Guide Wire –Regular Length, Regular Stiffness- • Should Be Available In 0.021, 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Be Between 145-180 Cm Long Should Be Available As Straight & J-Shaped Tip • Should Be Available In Variable Lengths Of Flexible/Floppy End • Should Be Available In Variable J Tip Sizes • Should Be Available Fixed As Well As Movable Core. Ptfe Coated Diagnostic Guide Wire –Exchange Length, Regular Stiffness- • Should Be Available In 0.021, 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Be Between 240-300 Cm Long Should Be Available As Straight & J-Shaped Tip • Should Be Available In Variable Lengths Of Flexible/Floppy End • Should Be Available In Variable J Tip Sizes • Should Be Available Fixed As Well As Movable Core. Ptfe Coated Guide Wire-Regular Length, Extra Stiff Shaft Strength- Amplatz Type- • Should Be Available In 0.032/0.035/0.038 Inches Size • Should Be 145-180 Cm Long • Should Be Available As Straight & J-Shaped Tip Ptfe Coated Guide Wire-Exchange Length, Extra Stiff Shaft Strength- Amplatz Type- • Should Be Available In 0.032/0.035/0.038 Inches Size • Should Be 240-300 Cm Long • Should Be Available As Straight & J-Shaped Tip Hydrophilic Diagnostic Guide Wire- Radifocus Type Regular Length, Regular Stiffness- • Must Be Available In 0.021, 0.025, 0.032, 0.035 Inches Size • Should Have Super Elastic Alloy Core • Should Have Super Flexible Wire Tip • Should Be Available In Straight And Angled Tip • Should Be Between 150-180 Cm Long Regular And Exchange Length Both Should Be Available Hydrophilic Diagnostic Guide Wire- Radifocus Type Exchange Length, Regular Stiffness- • Must Be Available In 0.021, 0.025, 0.032, 0.035 Inches Size • Should Have Super Elastic Alloy Core • Should Have Super Flexible Wire Tip • Should Be Available In Straight And Angled Tip • Should Be Between 240-300 Cm Long Regular And Exchange Length Both Should Be Available Diagnostic Judkins Shape Catheter Jr/Jl & Pigtail, Multi Purpose, Amplatz, Ima, Nih Cournand Catheter Etc. • 4 French/5 French/6 French/7 French/8 French/ Catheters In Various Standard Curves And Lengths Should Be Available Like Jl 3.0 To 5.0 And So On For Each Type For Catheter Transradial Diagnostic Coronary Catheter Opti Torque Type • 4 French/5 French/6French/ Diagnostic Coronary Catheters Must Be With Various Curves And Shapes Like Ultra Curve, Ikari Curve, Transformer Curve, Tractive Curve, And Various Shapes Like Tiger Jockey Shapes Etc. And Length Dedicated For Trans Radial Coronary Angiography And Brachial Approach Also • Soft Tip Compression Gf For Atraumatic Tip Should Be Equal To Or Less Then 100 • Soft Atraumatic, Radiopaque Tip With Increased Visibility • Double-Braid Wire Enhancing Strength, Torque And Kink Resistance Special Swan Ganz Catheter With Safety Wedge:- • 4 F Catheter Should Allow The Passage Of At Least 0.021 Inch, 5F-0.025 Inch, 6 F-0.035 Inch And 7 F, 8F-0.038 Inch, Ptfe/ Hydrophilic Guide Wire • Must Be Available In 4F, 5F, 6F, And 7F And 8 Fr. Sizes • Catheter Should Be Tapered At Tip To Ensure Uniform Diameter Of The Whole Catheter • 10 Cm Marking Along Catheter Body To Confirm Insertion Depth. • Balloon At Distal Tip With Standard Shape & Volume. Kit Must Be With All Accessories. Berman Catheter- • Must Be Available In 4F, 5F, 6F And 7F Sizes • Should Have 6-8 Holes Proximal To The Balloon For Dye Injection • Catheter Should Be Tapered At Tip To Ensure Uniform Diameter Of The Whole Catheter • 10 Cm Marking Along Catheter Body To Confirm Insertion Depth. • Balloon At Distal Tip With Standard Shape & Volume. Kit Must Be With All Accessories. Arterial Pressure Monitor Lines 150 To 200 Cm Long- • Should Be Soft And Kink Resistant • Should Give Reliable Pressure Measurements • Should Be Available In Size Of 150 To 200 Cm • Should Have Male Luer Lock Connection At One End And A Female Luer Lock Connection At The Other End • Should Meet Highest Medical Indus Standards For Arterial Pressure Lines Syringe For Pressure Injector Installed In Rnt Medical College, Udaipur- • Should Be Compatible With Existing Machines At Rntmc • Should Be Of Standard Volume & Material Disposable Transducers For Invasive Pressure Monitoring Compatible With Available System In Rnt Medical College, Udaipur- • Disposable Transducers For Invasive Pressure Monitoring • Should Be Compatible With Available System In. Bard, Philips, Data Scope At Rntmc • Should Meet Highest Medical Industrial Standards • Quality Certification Should Be Provided From Authorized Agencies Domes For Transducer For Invasive Pressure Monitoring- 1. Should Be Compatible With Existing Available System Like Bard, Philips, Should Meet Or Exceed Data Scope At Rntmc 2. Should Meet Or Exceed Highest Standards 3. Quality Certification Form Authorized Agencies To Be Provided Intravascular Retriever-Snare ‘Amplatz Goosenesk’ Type- Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Should Have 90 Degree Preformed Snare Loop • Variable Size Of Loop 5-35 Mm Intravascular Retriever- Microsnare ‘Amplatz Gooseneck’ Type- With All Accessories Like Sheath Etc. Microsnare Kit Should Include • A Microsnare, Compatible Micro-Catheter Micro-Catheter, Introducer And A Torque Device • Should Have Nitinol Shaft • Should Have 90 Degree Preformed Snare Loop • Variable Sizes 2-7 Mm Renal Double Curve Catheter, Head Hunter, Simmons-Sons, Verteberal Shephered Cook • In Various Standard Lengths And Curves. 4F To 7F For Femoral & Radial Approach Separate Length Must Be Available Radial Compression Band Tr Band Type- • Special Two Balloon Designed For Spot Compression Of Radial Puncture Site. Manifold With Attached Tubings Angio Kit • Manifold 2 Port With Smooth Movements Of Knob • One Luer Lock Control Syringe 10 Or 12 Ml For Contrast Injection • Two Large Bore Tubing With Flow Regulating Knob Of Length 150-200 Cm One For Pressure Monitoring And Another For Contrast, With Flow Regulating Knob. in Udaipur - Rajasthan has been published.
The last date of this tender is 26/09/2020, work value is  0 (Refer Doc) INR, EMD is  100000 INR and tender document fees is  1400 INR
For more details call us on +91 92760 83333 for bidding support this tender, GeM, vendor registration (if any) and tender BOQ documents.

Tender Document

Related Information

Location

Udaipur - Rajasthan ( IN )

Ownership

State Government Of Rajasthan

Sector

Health Services And Equipments

Important Dates

Published on

17 Sep, 2020

Submission Date

25 Sep, 2020

Opening Date

26 Sep, 2020

Key Values

Work Value

Refer Doc

EMD

1.00 Lacs

Document Fee

1.4 Thousand
Tender Document Liaison Service Connect with us